Vous êtes sur la page 1sur 3

Installation Manual for EFT integration for AUH region. NBAD.

Folder Name - NOV_11_2015_AUH_EFT


Folder Location - \\192.6.14.205\setup$\Softwares\EFT\
Folder Index - _Net (.net versions)
dotnetfx 2.0.exe , dotnetfx35.exe,
dotNetFx40_Full_x86_x64.exe & vcredist_x86.exe
NBAD DLL (ECR Setup & ECRSimulator)
Setup
ECR Setup.msi
setup.exe
ECR.dll, ECR.tlb, ECRSimulator.exe & Settings.xml
NCR EFT
Class, ext, gd90, System32, win, Install.bat, Readme.txt,
set_env.bat & test.bat

Step 1: Backup P_REGPAR.DAT C:\Server\ to E:\Setup\


And Edit the P_REGPAR.DAT
CTND1:081C081C081C081C081C000A000A000A000A000A
Where 081C C need to replace with J as below.
CTND1:081J081J081J081J081J000A000A000A000A000A
Enter the below entry on last.
VERI0:0000000000000000000000000000000000000000
Copy the New P_REGMOD.DAT from \NCR EFT\gd90\ to NCR
Server c:\Server and do run Support menu.
And do EOD.
Step 2: Copy the folder NOV_11_2015_AUH_EFT on POS terminal
Desktop.
Install .net version dotnetfx 2.0.exe followed by
dotnetfx35.exe, dotNetFx40_Full_x86_x64.exe and
vcredist_x86.exe.
Each installation POS has to be restart.
Step 3: Install the ECR Setup from \NBAD DLL\Setup\ ECR
Setup.msi
Step 4: Copy the content in the folder \NCR EFT to c:\
tmp\
Copy the Current P_REGPAR.DAT from the Server
And run the Install.bat.
Step 5: Need to register the ECR.dll on c:\windows\system32\
with .net.
c:\Windows\Microsoft.net\Framework\
v2.0.50727.3053\RegAsm.exe
The ECR.DLL must be registered with RegAsm found into the
V2.0 directory of the .net framework. Look at the image
below: a snapshot of the successfully registration of ECR.DLL
on V2.0 framework on your system preceded by the failed
registration with the V4.0 framework.
Step 6: Add ecrobject.jar to the path in environment variable.
System PropertyAdvancedEnvironment Variables TAB.

Once you click the Environment Variables TAB, under System


variables.
Select Class path and Edit. And enter the location of
ecrobcet.jar on last entry
;C:\Program Files\JavaSoft\jre\lib\ext\EcrObject.jar
C:\Program Files\NCR\NCR JavaPOS\;C:\Program
Files\NCR\NCR JavaPOS\NCRJavaPOS38.jar;C:\Program
Files\NCR\NCR JavaPOS\jpos1102.jar;C:\Program
Files\NCR\Retail\NCRRetailCommon.jar;;C:\Program
Files\NCR\NCR
JavaPOS\NCRJavaPOSClasses.jar;C:\Program
Files\NCR\NCR JavaPOS\jpos191.jar;C:\Program
Files\NCR\RSM\RSMJavaPOSUtils.jar;;C:\Program
Files\NCR\NCR JavaPOS\xerces.jar;C:\Program
Files\NCR\NCR JavaPOS\jpos191.jar;C:\Program
Files\JavaSoft\jre\lib\ext\EcrObject.jar

Step 7: Run the


ECRSimulator.exe from \NBAD DLL.
Mention the port # and time delay as mention below.

Once the test is successful, copy the Settings.xml to


c:\windows\system32\

Step 8: Start the POS program and check the changes has been
applied by doing and Credit card transactions.

Vous aimerez peut-être aussi