state of U.P.
Fire Protection System
Summary of DSR and Non DSR Items
GRAND SUMMARY
Fire Protection System (DSR + Non DSR Items)
TOTAL
Execution of various items (fire fighting works) on labour rate basis for housng project in the
state of U.P.
Fire Protection System Estimate of DSR Items
SUMMARY
Fire Protection System (DSR Items)
1 TOTAL OF ELECTRICALS
TOTAL
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of DSR Items
1.0 ELECTRICALS
1.1 9.3 Making straight through joint with cast resin compound
including ferrules and other jointing materials for following
size of PVC insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade as required.
1.2 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia Job 0
including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering
pipe etc. with charcoal/ coke and salt as required
TOTAL OF ELECTRICALS
TOTAL
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items
SUMMARY
Fire Protection System (Non DSR Items)
2 TOTAL OF ELECTRICALS
4 TOTAL OF EXTINGUISHERS
TOTAL
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items
1.9 Fixing 100 mm dia Pressure Guage on Sprinkler Header / Drain Each 4
Lines including Ball Valve and pipe stem complete as required.
2.0 ELECTRICALS
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items
Terrace Pump
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items
TOTAL OF ELECTRICALS
3.4 Fixing 63 mm dia, 15 M long RRL hose pipe with 63 mm dia Each 52
male and female stainless steel couplings duly binded with GI
wire, rivets etc conforming to IS:636 ( Type A ) as required.
3.7 Fixing First Aid Hose Reel with MS construction spray painted in Set 22
Post Office Red, conforming to IS:884 with upto date
amendments, complete with the following as required :
a) 36 m long 25 mm ( nominal internal ) dia water hose rubber IS
444 marked.
3.10 Installation, testing and commissioning of gun metal ball valves Each 3
of following sizes as required :
40 mm dia
3.11 Fixing 4 way Fire Brigade connection of cast iron body with 3 Set 4
nos gun metal male instantaneous inlet couplings complete with
cap and chain as required for 150 mm dia MS pipe connection,
conforming top IS:904 complete as required.
3.12 Fixing gun metal suction coupling 100 mm dia female round Each 0
thread top for fire brigade drawl of water from tank
3.13 Fixing gun metal four way Fire Brigade Filling Connection with 4 Each 0
nos 63 mm dia gun metal female connection in cast iron main
unit.
3.14 Fixing 25 mm dia brass Air Release Valve with Ball Valveand Set 2
Air Vessel.
3.15 Laying 300 mm dia NP II Class Hume Pipes at 1.0 M depth at Mtr,. 0
crossing of Hydrant Pipe below roads including filling of balance
area of pipe with sand complete as required.
3.16 Installation, testing and commissioning of non return valve of
following sizes confirming to IS:5312 complete with rubber
gaskets, GI bolts, nuts, washers etc as required.
3.16.1 150 mm dia Each 0
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items
4.0 EXTINGUISHERS
4.1 Fixing wall mounted signages consisting of Zinc Sulphide Photo Each 22
Luminescent coatings on acrylic sheet. Signage shall be any of
the following:Exit / Staircase / Extinguisher location / Manual
Call Box / Hydrant etc. Signage shall be as per drawing
4.2 Fixing wall mounted Floor Plan Signages for emergency Each 0
eggress consisting of Building Floor Plan screen painted on Zinc
Sulphide Photo Luminescent coatings on acrylic sheet.
Signages shall be 40 cm x 40 cm and shall consist of Floor Plan
with location of staircases / exits and arrow markings indicating
escape paths.
4.3 Laying Cable Fire Penetration Seal Hilti make as per BS:476 to Cu. 0
provide fire resistance of minimum 120 minutes in concrete / Mtr.
brick / panel walls / sub floors consisting of mineral wool panel
insert ( of min 140 Kg/m3 density ), clamping and holding
structure complete as required by supplier and sealing joint with
intumiscent seal. Rate in Sq M of penetration seal.
4.5 CO2 Fire Extinguisher of 4.5 Kg capacity fitted with screw down Sq Mtr. 0
type high pressure control valve with 1.0 M long rubber braided
discahrge hose with horn. The Body shall be CCE approved with
IS:2878 marking and supplied with initial charge of CO2 gas.
The valve shall conform to IS:3224.
4.6 Stored pressure ISI marked fire extinguishers of ABC Dry Mtr. 21
Chemical powder type 6 Kg capacity made of high pressure
steel cylinder complete with wheel type valve, internal discharge
tube, 1 M long high pressure wire braided discharge hose,
pressure guage and fully charged with UL listed ABC powder.
4.8 Fixing of ISI marked Dry Chemical type portable Fire Each 0
Extinguisher of 50 Kg capacity made of high pressure steel
cylinder complete with discharge tube, 1 M long high pressure
wire braided discharge hose, discharge horn fully charged with
ABC powder and with 2 kg CO2 external cartridge, plunger, two
wheel trolley complete.
TOTAL OF EXTINGUISHERS
5.3 Duct Casting Unit with casing of fabricated aluminium and Each 0
hinged inspection cover, 1 no inlet of appropriate length & 1 no
outlet tube 7.5 cm long & with 1 no Intelligent Addressable
Photo electric type Smoke Detector with mounting base
complete as required.
5.8 Response Indicator with twin transparent LED that shall glow red Each 0
in case of fire
5.12 Installing, testing and commissioing of Power supply unit with 25 Each 0
Ah SMF battery of 2 x 12 Volts for 15 minute back up complete
in wall mounted MS cabinet unit.
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items
TOTAL
Execution of various items (fire fighting works) on labour rate basis for housng project in the state of U.P.
Fire Protection System Estimate of Non DSR Items