Vous êtes sur la page 1sur 211

Bedienungsanleitung

Operating Instructions
Notice technique

Elados EMP KKS E60


und / and / et

Elados EMP KKS E60PLUS

EMP KKS E60

EMP KKS E60PLUS (mit/with/avec Dongle-Box)

Deutsch English Francaise

417101442_KKS_E60.docx Rev. 10-06.11


Inhaltsverzeichnis

1 Allgemeines .......................................................................................................................................... 5
1.1 Gewhrleistungsumfang ............................................................................................................................................................5
1.2 Kontaktadresse / Hersteller........................................................................................................................................................5
2 Sicherheit .............................................................................................................................................. 6
2.1 Sicherheitshinweise ...................................................................................................................................................................6
2.2 Hervorhebungen ........................................................................................................................................................................6
2.3 Aufzhlungen.............................................................................................................................................................................6
2.4 Spezielle Sicherheitshinweise bei Wartungs- und Reparaturarbeiten .........................................................................................6
3 Lieferumfang ......................................................................................................................................... 7
3.1 Zubehr zur Aufrstung auf EMP KKS E60PLUS ..........................................................................................................................7
4 Funktionsbeschreibung ....................................................................................................................... 8
4.1 Mechanische Funktionen ...........................................................................................................................................................8
4.2 Elektronische Funktionen...........................................................................................................................................................8
4.2.1 Betriebsarten .............................................................................................................................................................................8
4.3 Elektronische Zusatzfunktionen bei EMP KKS E60PLUS ..............................................................................................................8
5 Aufbau ................................................................................................................................................... 9
5.1 EMP KKS E60 ...........................................................................................................................................................................9
5.2 EMP KKS E60PLUS .....................................................................................................................................................................9
5.3 Anzeigen / Bedienelemente / Anschlussbuchsen .......................................................................................................................9
5.3.1 Ausfhrung EMP KKS E60 und EMP KKS E60PLUS ....................................................................................................................9
5.3.2 Anschlussbuchsen Dongle-Box ...............................................................................................................................................9
6 Einbau .................................................................................................................................................. 10
6.1 Einbauschema .........................................................................................................................................................................10
7 Gerteinstallation ............................................................................................................................... 11
7.1 Hydraulische Installation ..........................................................................................................................................................11
7.1.1 Installationsbeispiele................................................................................................................................................................11
7.1.2 Anschluss der Saug- und Rcklaufleitung ................................................................................................................................12
7.1.3 Anschluss der Dosierleitung.....................................................................................................................................................13
7.2 Elektrische Installation .............................................................................................................................................................13
7.2.1 Ein- und Ausgnge ..................................................................................................................................................................13
7.2.2 Anschlussbelegung Steckplatz I (3-polig) Eingang fr Niveauvorwarnung und Leermeldung ...................................................14
7.2.2.1 Installation Sauglanze mit Niveauvorwarnung und Leermeldung.............................................................................................................................. 14
7.2.3 Anschlussbelegung Steckplatz II (5-polig) Eingang fr Impuls-, Normsignal, Dosiersperre, Charge und Dosierberwachung ..15
7.2.3.1 Installation fr Impulsansteuerung (Wasserzhler) ................................................................................................................................................... 15
7.2.3.2 Installation Normsignal Ansteuerung ......................................................................................................................................................................... 15
7.2.3.3 Installation Ansteuerung ber Dosiersperre............................................................................................................................................................... 16
7.2.3.4 Installation Chargenfunktion ....................................................................................................................................................................................... 16
7.2.3.5 Installation Dosierberwachung ................................................................................................................................................................................. 17
7.2.4 Anschlussbelegung Steckplatz III (4-polig), Ausgang fr Alarm und Hubsignal ........................................................................18
7.2.4.1 Installation Niveau- bzw. Strmeldeausgang................................................................................................................................................... 18
7.2.4.2 Installation Hubsignalausgang bei 24 V / DC .................................................................................................................................................. 18
7.2.4.3 Hardwareumstellung fr den Alarmkontakt ...................................................................................................................................................... 19
7.2.4.3.1 Bei Konfigurationseinstellung Alarmausgang EIN 19
7.2.4.3.2 Bei Konfigurationseinstellung Alarmausgang AUS 19
7.2.5 Anschlussbelegung Steckplatz IV, Netzanschluss ...................................................................................................................19
PLUS
8 Aufrstung der EMP KKS E60 auf EMP KKS E60 ..................................................................... 20
8.1 Montage der Dongle-Box .........................................................................................................................................................20
8.2 Anschlussbelegung der Steckpltze ........................................................................................................................................21
8.2.1 Anschlussbelegung Steckplatz V (5-polig), Eingang fr Ovalradzhler.....................................................................................21
8.2.1.1 Installation Ovalradzhler (OGM oder OGMPLUS) ...................................................................................................................................................... 21
8.2.2 Anschlussbelegung Steckplatz VII (5-polig) Eingang fr Chargenimpuls und Dosiersperre ......................................................22
8.2.2.1 Installation Chargenimpuls ......................................................................................................................................................................................... 22
8.2.2.2 Installation Dosiersperre............................................................................................................................................................................................. 23
8.2.3 Anschlussbelegung Steckplatz VIII (5-polig) Eingang fr Impuls, Normsignaleingang und Dosiersperre ..................................23
8.2.3.1 Installation fr Impulsansteuerung (Wasserzhler) ................................................................................................................................................... 23
8.2.3.2 Installation Normsignal (mA) ...................................................................................................................................................................................... 24
8.2.3.3 Installation Dosiersperre............................................................................................................................................................................................. 24
9 Inbetriebnahme ................................................................................................................................... 25
9.1 Einschalten der Pumpe ............................................................................................................................................................25
9.2 Ausschalten der Pumpe ...........................................................................................................................................................25
9.3 Tastenfunktionen .....................................................................................................................................................................25
9.4 Displayanzeigen ......................................................................................................................................................................25
9.5 Erstinbetriebnahme / Auslieferungszustand .............................................................................................................................26
9.5.1 Anzeige der Softwareversion ...................................................................................................................................................26
9.5.2 Anzeige in der Betriebsebene ..................................................................................................................................................26
9.5.3 Konfiguration ...........................................................................................................................................................................26

417101442_KKS_E60.docx -2- Rev. 10-06.11


10 Menbeschreibung ............................................................................................................................. 27
10.1 Hauptmen ..............................................................................................................................................................................27
10.1.1 bersicht .................................................................................................................................................................................27
10.2 Betriebsart ...............................................................................................................................................................................28
10.2.1 Auswhlen ...............................................................................................................................................................................28
10.2.2 Betriebsart / Intern ...................................................................................................................................................................28
10.2.2.1 Auswhlen .................................................................................................................................................................................................................. 28
10.2.2.2 Displayanzeige in der Betriebsebene / Einstellen...................................................................................................................................................... 29
10.2.3 Betriebsart: Impuls ...................................................................................................................................................................29
10.2.3.1 Auswhlen .................................................................................................................................................................................................................. 30
10.2.3.2 Displayanzeige in der Betriebsebene/ Einstellen....................................................................................................................................................... 30
10.2.4 Betriebsart / Strom (Extern-Normsignal) ..................................................................................................................................31
10.2.4.1 Auswhlen .................................................................................................................................................................................................................. 31
10.2.4.1.1 Einstellen Betriebsart / Strom / beliebig 32
10.2.4.2 Displayanzeige in der Betriebsebene ........................................................................................................................................................................ 32
10.3 Konfiguration ...........................................................................................................................................................................32
10.3.1 bersicht .................................................................................................................................................................................32
10.3.2 Display Rollen .......................................................................................................................................................................33
10.3.3 Konfiguration / Sprache ...........................................................................................................................................................33
10.3.3.1 Auswhlen .................................................................................................................................................................................................................. 33
10.3.4 Konfiguration / Einheit ..............................................................................................................................................................33
10.3.4.1 Auswhlen .................................................................................................................................................................................................................. 33
10.3.5 Konfiguration / Code ................................................................................................................................................................34
10.3.5.1 Auswhlen .................................................................................................................................................................................................................. 34
10.3.5.2 Einstellen .................................................................................................................................................................................................................... 34
10.3.6 Konfiguration / Autostart ..........................................................................................................................................................34
10.3.6.1 Auswhlen .................................................................................................................................................................................................................. 35
10.3.7 Konfiguration / Dosiersperre ....................................................................................................................................................35
10.3.7.1 Auswhlen .................................................................................................................................................................................................................. 35
10.3.8 Konfiguration / Niveaukontakt ..................................................................................................................................................35
10.3.8.1 Auswhlen .................................................................................................................................................................................................................. 36
10.3.9 Konfiguration / Alarmausgang ..................................................................................................................................................36
10.3.9.1 Auswhlen .................................................................................................................................................................................................................. 36
10.3.9.2 Umstellung Funktionsweise Alarmrelais-Kontakt ....................................................................................................................................................... 36
10.3.10 Konfiguration / Impulsspeicher .................................................................................................................................................37
10.3.10.1 Auswhlen .................................................................................................................................................................................................................. 37
10.3.10.2 Displayanzeige in der Betriebsebene bei aktiviertem Impulsspeicher ...................................................................................................................... 37
10.3.11 Konfiguration / Ovalradzhler (nur E60PLUS & OGM bzw. OGM PLUS).........................................................................................38
10.3.11.1 Auswhlen .................................................................................................................................................................................................................. 38
10.3.12 Konfiguration / Dosierregler (nur E60PLUS & OGMPLUS) ............................................................................................................38
10.3.12.1 Auswhlen .................................................................................................................................................................................................................. 39
10.3.12.2 Displayanzeige in der Betriebsebene bei aktiviertem Dosierregler ........................................................................................................................... 39
10.3.13 Konfiguration / Dosierberwachung .........................................................................................................................................39
10.3.13.1 Auswhlen .................................................................................................................................................................................................................. 40
10.3.13.2 Dosierberwachung / Pumpe stoppen ....................................................................................................................................................................... 40
10.3.13.3 Dosierberwachung / Hbe ........................................................................................................................................................................................ 40
10.3.13.4 Dosierberwachung / Abweichung (nur bei E60PLUS & OGM bzw. OGMPLUS) ........................................................................................................... 41
10.3.13.5 Dosierberwachung / Eingang (nur bei E60 OHNE Dongle-Box) ............................................................................................................................. 41
10.3.13.6 Anzeige der Ovalradzhler-Impulse (nur E60+) ........................................................................................................................................................ 42
10.3.14 Konfiguration / MicroFlowPLUS ...................................................................................................................................................42
10.3.14.1 Auswhlen .................................................................................................................................................................................................................. 42
10.3.14.2 MicroFlowPLUS / Pumpe stoppen................................................................................................................................................................................. 43
10.3.14.3 MicroFlowPLUS / Hbe ................................................................................................................................................................................................. 43
10.3.14.4 MicroFlowPLUS / Abweichung ...................................................................................................................................................................................... 43
10.3.14.5 MicroFlowPLUS / Dosierpause...................................................................................................................................................................................... 44
10.3.14.6 MicroFlowPLUS / Dosierverzgerung ........................................................................................................................................................................... 44
10.3.14.7 MicroFlowPLUS / Kalibrierung....................................................................................................................................................................................... 45
10.3.15 Konfiguration Charge.............................................................................................................................................................45
10.3.15.1 Auswhlen .................................................................................................................................................................................................................. 45
10.3.15.2 Charge / Menge .......................................................................................................................................................................................................... 46
10.3.15.3 Charge / Eingang (nur bei E60 OHNE Dongle-Box) .................................................................................................................................................. 47
10.3.15.4 Displayanzeige in der Betriebsebene ........................................................................................................................................................................ 47
10.3.16 Konfiguration DegasPLUS ..........................................................................................................................................................47
10.3.16.1 Auswhlen .................................................................................................................................................................................................................. 48
10.3.16.2 Degas / Degas Hbe .................................................................................................................................................................................................. 48
10.3.16.3 Degas / Degas Pause ................................................................................................................................................................................................ 49
10.4 Kalibrierung .............................................................................................................................................................................49
10.4.1 bersicht .................................................................................................................................................................................49
10.4.2 Kalibrierung Pumpe .................................................................................................................................................................50
10.4.2.1 Vorbereitung ............................................................................................................................................................................................................... 50
10.4.2.2 Kalibrierung / Starten.................................................................................................................................................................................................. 50
10.4.3 Kalibrierung Pumpe mit Ovalradzhler (OGMPLUS) ...................................................................................................................50
10.4.3.1 Vorbereitung ............................................................................................................................................................................................................... 51
10.4.3.2 Kalibrierung / Starten.................................................................................................................................................................................................. 51
10.4.4 Kalibrierung / Manuell ..............................................................................................................................................................52
10.4.4.1 Tabelle Kalibrierdaten ................................................................................................................................................................................................ 52
10.5 Betriebsdaten ..........................................................................................................................................................................52
10.5.1 bersicht .................................................................................................................................................................................53
10.5.2 Betriebsdaten / Betriebsstunden ..............................................................................................................................................53
10.5.2.1 Auswhlen / Anzeigen / Lschen ............................................................................................................................................................................... 53
10.5.3 Betriebsdaten / Liter.................................................................................................................................................................53
10.5.3.1 Auswhlen / Anzeigen / Lschen ............................................................................................................................................................................... 54
10.5.4 Betriebsdaten / Impulsanzahl ...................................................................................................................................................54
10.5.4.1 Auswhlen / Anzeigen / Lschen ............................................................................................................................................................................... 54

417101442_KKS_E60.docx -3- Rev. 10-06.11


11 Wartung ............................................................................................................................................... 55
11.1 Austausch von Saug- / Rcklauf- und Druckventil ....................................................................................................................55
11.1.1 Saug- und Rcklaufventile lagerichtig einbauen.......................................................................................................................56
11.2 Austausch der Membrane und des Pumpenkopfes ..................................................................................................................56
11.3 Austausch der Zylinderkolbeneinheit .......................................................................................................................................57
11.4 Justierung der mechanischen Hubverstellung ..........................................................................................................................57
12 Betriebsstrungen ............................................................................................................................. 58
12.1 Warnmeldungen Dosierung (Display) ......................................................................................................................................58
12.2 Strmeldungen (Display) .........................................................................................................................................................58
12.2.1 Strungstabelle........................................................................................................................................................................59
13 Verschlei- und Ersatzteile (Standard-Ausfhrung) ...................................................................... 60
13.1 Explosionszeichnung ...............................................................................................................................................................60
13.2 Verschleiteilset ......................................................................................................................................................................61
14 Technische Daten ............................................................................................................................... 62
14.1 Pumpenschlssel ....................................................................................................................................................................62
14.1.1 Pumpenschlsseldefinition E60 ...............................................................................................................................................64
14.2 Abmessungen..........................................................................................................................................................................65
14.3 Technische Daten bersichtstabellen....................................................................................................................................66
14.3.1 Elektrische Daten ....................................................................................................................................................................66
14.3.2 Allgemeine Daten ....................................................................................................................................................................66
14.3.3 Ein- / Ausgangsbeschaltung ....................................................................................................................................................67
14.3.3.1 Steckplatz I ................................................................................................................................................................................................................. 67
14.3.3.2 Steckplatz II ................................................................................................................................................................................................................ 67
14.3.3.3 Steckplatz III ............................................................................................................................................................................................................... 67
14.4 Werkstoffe ...............................................................................................................................................................................68
14.5 Anschlussstecker / Steuer Ein- und Ausgnge.........................................................................................................................68
14.5.1 Pinbelegung / Aderfarben Stecker I (3-polig)............................................................................................................................68
14.5.2 Pinbelegung / Aderfarben Stecker II (5-polig)...........................................................................................................................68
14.5.3 Pinbelegung / Aderfarben Stecker III (4-polig)..........................................................................................................................68
14.6 Dosierleistungen ......................................................................................................................................................................69
14.7 Frderleistung in Abhngigkeit von Gegendruck ......................................................................................................................69
14.8 Frderleistung in Abhngigkeit von der Hublnge ....................................................................................................................70
15 Konformittserklrung ....................................................................................................................... 71

417101442_KKS_E60.docx -4- Rev. 10-06.11


1 Allgemeines
Dieses Technische Handbuch enthlt alle Anweisungen zur Installation, Inbetriebnahme,
Wartung und Reparatur der Membran-Dosierpumpe der Baureihe ELADOS EMP KKS- E60
und ELADOS EMP KKS- E60PLUS.

WICHTIG
Achten Sie bei der Verwendung dieser Bedienungsanleitung unbedingt auf die
Softwareversion Ihrer Pumpe (siehe Kapitel 9.5.1).
Bei den deutschsprachigen Kapiteln dieser Anleitung handelt es sich um die
HINWEIS ORIGINALBETRIEBSANLEITUNG, die rechtlich relevant ist.
Alle anderen Sprachen sind bersetzungen der ORIGINALBETRIEBSANLEITUNG

Die Sicherheitshinweise und Hervorhebungen sind in jedem Fall zu beachten!

1.1 Gewhrleistungsumfang
Gewhrleistung in Bezug auf Betriebssicherheit, Zuverlssigkeit und Leistung dieser
Ausfhrung wird vom Hersteller nur unter folgenden Bedingungen bernommen:
Montage, Anschluss, Einstellung, Wartung und Reparatur werden von autorisiertem
und geschultem Fachpersonal durchgefhrt.
Die Membran-Dosierpumpe wird entsprechend den Ausfhrungen der im Lieferumfang
enthaltenen Bedienungsanleitung verwendet.
Bei Reparaturen werden nur Original-Ersatzteile verwendet.
Durch ffnen des Pumpengehuses geht der Gewhrleistungsanspruch verloren.
Im brigen gelten die allgemeinen Garantie- und Leistungsbedingungen der
ECOLAB Engineering GmbH.

1.2 Kontaktadresse / Hersteller

ECOLAB Engineering GmbH


Raiffeisenstrae 7
D-83313 Siegsdorf
Telefon (+49) 86 62 / 61 0
Telefax (+49) 86 62 / 61 2 35
eMail: engineering-mailbox@ecolab.com

417101442_KKS_E60.docx -5- Rev. 10-06.11


2 Sicherheit
2.1 Sicherheitshinweise
Die Anschluss- und Reparaturarbeiten an der Membran-Dosierpumpe drfen nur von
autorisiertem Fachpersonal ausgefhrt werden.
Vor allen Arbeiten an elektrischen Teilen unbedingt den Netzstecker ziehen.
Bei Wartungs- und Reparaturarbeiten ist geeignete Schutzkleidung zu tragen.
Die Sicherheitsbestimmungen im Umgang mit Chemikalien sind stets zu beachten.

2.2 Hervorhebungen
In dieser Wartungsanleitung haben die hier dargestellten Hervorhebungen folgende
Bedeutung:
wird benutzt, wenn ungenaues Befolgen oder Nichtbefolgen von Bedienungsanweisungen,
VORSICHT Arbeitsanweisungen, vorgeschriebenen Arbeitsablufen und dergleichen zu Verletzungen
oder Unfllen fhren kann.
wird benutzt, wenn ungenaues Befolgen oder Nichtbefolgen von Bedienungsanweisungen,
ACHTUNG Arbeitsanweisungen, vorgeschriebenen Arbeitsablufen und dergleichen zur
Beschdigung des Gertes fhren kann.

WICHTIG
wird benutzt, wenn auf eine besondere Aufmerksamkeit im Umgang mit dem Gert
geachtet werden muss.

HINWEIS wird benutzt, wenn auf eine Besonderheit aufmerksam gemacht werden soll.

2.3 Aufzhlungen
Aufzhlungen, die mit diesem Vorzeichen () markiert sind, beschreiben eine Ttigkeit,
die durch den Monteur /Anwender durchgefhrt werden muss.

2.4 Spezielle Sicherheitshinweise bei Wartungs- und Reparaturarbeiten


Vor Reparatur- und Wartungsarbeiten und Dosierung von gefhrlichen Medien immer den
Dosierkopf splen, die Druckleitung entlasten und Schutzkleidung (Schutzbrille,
Schutzhandschuhe und Schrze) tragen.
Elektroreparaturen drfen nur durch Elektrofachkrfte ausgefhrt werden.
VORSICHT Sicherheitsregeln der Berufsgenossenschaft VB G 4 & ZH 1/11)!
Beim ffnen von Abdeckungen oder Entfernen von Teilen knnen Spannungsfhrende
Teile freigelegt werden.
Auch knnen Anschlussstellen spannungsfhrend sein.

WICHTIG Bei Reparaturen drfen nur Original-Ersatzteile verwendet werden.

417101442_KKS_E60.docx -6- Rev. 10-06.11


3 Lieferumfang
Der Lieferumfang besteht aus:
Abb. 3.1 Dosierpumpe, Ausfhrung EMP KKS E60
inklusive Netzanschlussleitung (2 m) mit
Schutzkontaktstecker und Blindstecker
fr Ein- und Ausgnge

Abb. 3.2 Anschlussstecker 5-polig fr Impuls- bzw.


Normsignaleingang

Abb. 3.3 Anschlussteile


(fr Schlauch 4/6, 6/8, 6/12 (ID/AD) mm)

Montageskizze fr Schlauchanschlsse
(Beipack)
Steckerbelegungsplan
(Beipack)
Abb. 3.4 Kurzanleitung
(Art.-Nr. 417101795)
CD Bedienungsanleitung
(Art.-Nr. 417101793)

3.1 Zubehr zur Aufrstung auf EMP KKS E60PLUS


Abb. 3.5 Dongle-Box (Art. Nr. 248606)

417101442_KKS_E60.docx -7- Rev. 10-06.11


4 Funktionsbeschreibung
4.1 Mechanische Funktionen
Die Dosierpumpen der Reihe ELADOS EMP KKS sind elektromotorisch betriebene
Membrankolben-Pumpen.
Die Membrane dient zur Vorfrderung, mit dem Kolben wird dosiert. Aufgrund der stndigen
berschussrckfhrung arbeitet diese Dosierpumpe selbstentlftend.
Die Dosierpumpe ist fr den Einsatz von sauberen, nicht abrasiven Dosiermedien bis zu
einer Viskositt von 200 mPas (Messmethode: Brookfield) geeignet.
Der Antrieb der Dosierpumpe erfolgt durch einen blockierfesten Synchronmotor und ein
Pleuel-Exzentergetriebe.
Abb. 4.1
Bei der Bewegung der Membrane (Pos. 1) in
Richtung Getriebe, wird das Dosiermedium ber das
Ventil (Pos. 2) angesaugt. Gleichzeitig entsteht im
Kompressionsraum der Dosierkolben-
Zylindereinheit (Pos. 3) ein Vakuum und das
vorgefrderte Dosiermedium strmt nach Freigabe
der Steuerbohrung (Pos. 4) in diesen Raum.
Bei der Druckbewegung erfolgt die Dosierung ber
das Ventil (Pos. 5), das berschssige
Dosiermedium wird ber das Rcklaufventil (Pos. 6)
in den Behlter zurckgefrdert. Die Frdermenge
lsst sich whrend des Betriebes ber die
Hubverstellung (Pos. 7) von 0 - 100 % regulieren.
Hierbei wird die Eintauchtiefe des Zylinders verndert. Die Vorfrdermenge bleibt konstant.
Zum Schutz der Dosieranlage wird die Verwendung einer Sauglanze mit
Leermeldeeinrichtung und Schmutzfnger aus unserem Zubehrprogramm dringend
ACHTUNG empfohlen! Die Leermeldeeinrichtung schaltet bei Unterschreitung eines bestimmten
Niveaus (im Behlter) die Pumpe ab.

4.2 Elektronische Funktionen


Die Bedienung der Pumpe erfolgt ber vier Tasten (Abb. 5.5, Pos. 2, 3, 4 und 5)
(siehe Kapitel 9.3 Tastenfunktionen).
Die Betriebsanzeige wird ber ein Grafikdisplay (Abb. 5.5, Pos. 6) dargestellt.

4.2.1 Betriebsarten
Die Pumpe kann in drei verschiedenen Betriebsarten genutzt werden:
INTERN Manuelle Dosierfunktion (Werkseinstellung)
EXTERN Impulsansteuerung
EXTERN Normsignalansteuerung (mA)
Zustzlich kann ber den Menpunkt Konfiguration eine Chargendosierung (pro Startimpuls
wird eine festgelegte Menge dosiert) eingestellt werden.

4.3 Elektronische Zusatzfunktionen bei EMP KKS E60PLUS


Ovalradzhler Anschluss / Ovalradzhler Auswertung
Dosierregelung mit Hilfe eines Ovalradzhlers, Typ OGMPLUS
Mglichkeit einer automatischen Kalibrierung mit Ovalradzhler, Typ OGMPLUS
Trennung der Eingnge Dosiersperre / Impuls / Dosierberwachung / Ovalradzhler auf
mehrere Anschlsse zur Vereinfachung der externen Anschlsse.

417101442_KKS_E60.docx -8- Rev. 10-06.11


5 Aufbau
5.1 EMP KKS E60
Abb. 5.1 Abb. 5.2 3 4 6 5
6

4 5
3

1
A
2
1 A

5.2 EMP KKS E60PLUS


Abb. 5.3 Abb. 5.4 3 4 6 5

1 B

Pos. Bezeichnung
1 Saugventil (Anschluss saugseitig)
2 Membranbruchablauf
3 Druckventil (Anschluss druckseitig)
4 Hublngenverstellung
5 Pumpenkopf
6 Rcklaufanschluss (Rckfhrung in den Behlter!)
A Schiene zum Anschluss der Dongle-Box
B Dongle-Box
Flierichtung des Dosiermediums

5.3 Anzeigen / Bedienelemente / Anschlussbuchsen


5.3.1 Ausfhrung EMP KKS E60 und EMP KKS E60PLUS
Abb. 5.5 Pos. Bezeichnung
1 Drehknopf fr Hublngeneinstellung
6 2 Menu/Exit, Pfeil nach oben Taste
1 2
3 Menu/Exit, Pfeil nach unten Taste
3 4 Start/Stop - Taste (Enter Funktion)
4 5 Test - Taste
5 6 Grafik Display
Eingang fr Niveauvorwarnung, und
I
Leermeldung (siehe 7.2.2 & 14.5.1)
IV Eingang fr Impuls- / Normsignal und
II
Dosiersperre (siehe 7.2.3 & 14.5.2)
I Ausgang fr Leermeldung, Strmeldung und
III
II Hubsignal (siehe 7.2.4 & 14.5.3)
III IV Netzanschluss (siehe 7.2.5)

5.3.2 Anschlussbuchsen Dongle-Box


Abb. 5.6 Pos. Bezeichnung
V Eingang fr Ovalradzhler
VI Anschlussverbindung fr Impulseingang an EMP Pumpe (Eingang II)
VII Eingang fr Chargenimpuls und Dosiersperre
VIII Eingang fr Impuls, Normsignaleingang und Dosiersperre

417101442_KKS_E60.docx -9- Rev. 10-06.11


6 Einbau
Die Installation ist nur durch zugelassene Fachkrfte durchzufhren und die allgemeinen
ACHTUNG Richtlinien und rtlichen Installationsvorschriften zu beachten!

Die Dosierpumpe sollte an gut zugnglicher, frostgeschtzter Stelle montiert werden.


Die Umgebungstemperatur darf +40 C nicht bersteigen.
Die Einbaulage des Gertes muss waagerecht sein.
Die Pumpe ist an den dafr vorgesehenen Bohrungen fest mit der Konsole bzw. dem
Behlter zu verschrauben (Bohrungsabstand siehe Kapitel 14.2 Abmessungen).

6.1 Einbauschema
Abb. 6.1 Pos. Bezeichnung
1 berdruckventil
2 Dosierventil / Druckhalteventil
3 Sauglanze bzw. Bodensaugventil

Dosier-/Druckhalte- und berdruckventile knnen durch ein Mehrfunktionsventil (MFV)


HINWEIS aus unserem Lieferprogramm ersetzt werden, welches all diese Funktionen vereint.

417101442_KKS_E60.docx - 10 - Rev. 10-06.11


7 Gerteinstallation
7.1 Hydraulische Installation
7.1.1 Installationsbeispiele
Die hier aufgefhrten Installationsbeispiele und Anwendungen haben funktionalen
HINWEIS Charakter. Sie geben einen berblick ber korrekte oder zu vermeidende Installationsarten
fr die richtige Funktion der Pumpe.
Besondere Manahmen und Schutzeinrichtungen fr die Dosierung gefhrlicher bzw.
ACHTUNG aggressiver Chemikalien sind hier nicht aufgefhrt. Beachten Sie bei deren Verwendung
unbedingt die gesetzlichen Vorschriften und das entsprechende Produktdatenblatt.
A) Die Anordnung der Dosierpumpe sollte vorzugsweise auf Abb. 7.1
bzw. ber dem Dosierbehlter erfolgen.
Bei Medien, die zu Sedimentation neigen, muss
das Bodensaugventil bzw. Fuventil der
HINWEIS Saugleitung / Sauglanze ber der zu erwartenden
Schlammschicht montiert sein.
B) Zwischen dem Gegendruck an der Impfstelle und dem
anstehenden Druck an der Dosierpumpe muss eine positive
Druckdifferenz von mindestens 1 bar herrschen.
Ist dies nicht der Fall, muss ein Druckhalteventil (2) in die
Dosierleitung eingebaut werden.
Ausserdem empfiehlt es sich zur Vermeidung unzulssig
hoher Drcke in der Dosierleitung ein entsprechendes
Sicherheits-berstrmventil (3) zu installieren. Die
berstrmleitung dieses Ventils sollte drucklos in den
Behlter zurckgefhrt werden.
Die berstrmleitung darf nicht in die Saugleitung
ACHTUNG der Dosierpumpe zurckgefhrt werden!
C) An der Impfstelle sollte grundstzlich ein federbelastetes
Impf- oder Dosierventil (1) eingebaut sein (auch bei
Eindosierung in druckfreie Systeme).
Abb. 7.2

Bei Dosierung in Rohrleitungen mit Unterdruck ist ein


Druckhalteventil (4) in die Dosierleitung einzubauen.
Ein Druckhalteventil oder ein Dosierventil ist kein
HINWEIS absolut dicht schlieendes Absperrorgan.
Um ein Auslaufen des Dosiermediums bei Pumpen-Stillstand zu
verhindern, empfehlen wir zustzlich den Einbau eines
Magnetventils (3), das mit der Pumpe freigegeben wird.

Pos Bezeichnung
1 Impfventil / Dosierventil
2 Externe Freigabe
3 Magnetventil
4 Druckhalteventil
Abb. 7.3

Saugleitungen sind so kurz wie mglich zu halten.


Lange und verschlungene Saugleitungen knnen zu
Luftansammlungen im System fhren.
Die Saughhe darf max. 2 m und die maximale
Fliegeschwindigkeit 0,3 m/s betragen!
(siehe auch Kapitel 14.3 Technische Daten)

417101442_KKS_E60.docx - 11 - Rev. 10-06.11


Abb. 7.4

Saugleitung immer steigend zum Saugventil der


Dosierpumpe verlegen.

Abb. 7.5

Installation einer Dosierberwachungseinrichtung:


Eine Dosierberwachungseinrichtung Ovalradzhler
oder Strmungswchter- muss in die Dosierleitung nach
dem berstrmventil und vor einem Druckhalte- bzw.
Dosierventil eingebaut werden.

7.1.2 Anschluss der Saug- und Rcklaufleitung


Abb. 7.6 Pos. Bezeichnung
1 berwurfmutter
2 Spannteil
3 Kegelteil
4 O-Ring
5 Fixierbohrung
Achten Sie darauf, das beim Anschluss der
Saug- und Druckleitung die O-Ringe (Pos. 4)
VORSICHT auf den Anschlssen montiert sind, um die
notwendige Abdichtung zu erreichen.
Wir empfehlen die Verwendung einer
HINWEIS passenden Sauglanze aus unserem
Lieferprogramm.
Bei Verwendung anderer Schlauchleitungen
den Biegeradius entsprechend auslegen.
Rcklaufschlauch darf nicht geknickt
VORSICHT werden. Installation so durchfhren, dass
kein Zug auf die Rcklaufleitung auftreten
kann.

Duo-Schlauch trennen, gerade abschneiden und Verbindungsstege entfernen.


berwurfmutter (Pos. 1), Spannteil (Pos. 2) ber Saugschlauchstck schieben.
Kegelteil (Pos. 3) bis zum Anschlagbund aufstecken.
O-Ring (Pos. 4) in Ventilnut legen und berwurfmutter per Hand festziehen.
Rcklaufschlauchstck durch Fixierbohrung (Pos. 5) ziehen und wie
Saugschlauchstck befestigen.
Sauglanze ins Liefergebinde stellen.

417101442_KKS_E60.docx - 12 - Rev. 10-06.11


7.1.3 Anschluss der Dosierleitung
Abb. 7.7 Dosierschlauch bzw. Rohr gerade abschneiden.
berwurfmutter (Pos. 2) und Quetschring (Pos. 3)
aufschieben.
Schlauch bzw. Rohr auf Anschlussstck (Pos. 4)
bis zum Anschlag aufstecken und per Hand fest
verschrauben.
Winkelposition durch Lockern der berwurfmutter
(Pos. 1) einstellen und wieder festziehen.
Max. zulssigen Betriebsdruck des
VORSICHT Dosierschlauches / Rohr beachten!
Nach 24 Stunden Betrieb die
HINWEIS Dosierkopfschrauben mit 3-4 Nm
diagonal nachziehen.
Die Dosierpumpe kann von der Prfung
VORSICHT im Werk Wasserreste im Dosierkopf
enthalten.

7.2 Elektrische Installation


7.2.1 Ein- und Ausgnge
Abb. 7.8
V VI I II
Die Ein- und Ausgnge sind im Lieferzustand mit
Schutzkappen versehen, die bei Bedarf zu entfernen
sind. (Pos. I-VIII)
Da die Schutzkappen, bzw. Anschluss-
Stecker codiert sind, ist auf die jeweilige
HINWEIS Symbolik zu achten (I-III). Wenden Sie
beim Aufstecken keine groe Kraft an.

VII VIII III IV


Zum Schutz der Elektronik gegen Kontakt mit Chemie oder Feuchtigkeit, die Dosierpumpe
nie ohne Schutzkappen oder Anschlusskabel betreiben, da die Anschlsse oxidieren
ACHTUNG knnen. Ein Vertauschen der Schutzkappen kann zu Fehlfunktionen der Pumpe und/oder
Beschdigungen der Anschlsse fhren!

417101442_KKS_E60.docx - 13 - Rev. 10-06.11


7.2.2 Anschlussbelegung Steckplatz I (3-polig)
Eingang fr Niveauvorwarnung und Leermeldung
Abb. 7.9 Aderfarbe
Pin Belegung
(Anschlusskabel)
1 braun Eingang Niveauvorwarnung
3 1 3 blau Eingang Niveau-, Leermeldung
4 schwarz GND ()
4 (Steckerbelegung siehe Kapitel 14.5.1 Technische Daten)

7.2.2.1 Installation Sauglanze mit Niveauvorwarnung und Leermeldung


Steckplatz I muss immer belegt sein, entweder durch die montierten Brckenstecker
(Schutzkappe mit entsprechendem Symbol, siehe Kapitel 7.2.1, Abb. 7.9, Pos. I) oder durch
HINWEIS Anschluss der Leermeldeeinrichtung (Sauglanzenstecker). Die Schaltlogik des
Niveaukontaktes ist invertierbar. (siehe Kapitel 10.3.8 Konfiguration Niveaukontakt)
Abb. 7.10
1+4 = Eingang Niveauvorwarnung
Schaltkontakt Niveauvorwarnung offen:
Niveauvorwarnung aktiv
(Schaltlogik invertierbar, siehe
Kapitel 10.3.8), Leermeldesymbol
im Display blinkt, Pumpe luft
weiter.
PIN Belegung
1 Schalteingang
4 GND ()

3+4 = Eingang Niveau-


Leermeldung
Schaltkontakt Leermeldung offen:
Niveau Leermeldung aktiv
(Schaltlogik invertierbar siehe
Kapitel 10.3.8), Leermeldesymbol
wird im Display angezeigt,
Pumpe wird gesperrt.
PIN Belegung
3 Schalteingang
4 GND ()

417101442_KKS_E60.docx - 14 - Rev. 10-06.11


7.2.3 Anschlussbelegung Steckplatz II (5-polig)
Eingang fr Impuls-, Normsignal, Dosiersperre, Charge und Dosierberwachung
Abb. 7.11 Aderfarbe
Pin (Anschlusskabel)
Belegung
1 braun Ausgang 5 V, DC(belastbar mit max. 50 mA)
2 Impulseingang (auch als Charge / Dosierberwachung
5 2 wei
konfigurierbar, siehe Kapitel 10.3.13 und 10.3.15)
Eingang Dosiersperre (auch als Charge / Dosierberwachung
3 1 3 blau
konfigurierbar, siehe Kapitel 10.3.13 und 10.3.15)
4 schwarz GND ()
4 5 grau Eingang Normsignal 0/4...20 mA
(Steckerbelegung siehe Kapitel 14.5.2 Technische Daten)
Schutzkappe abziehen
Anschlussstecker entsprechend der Anschlussbelegung montieren.

ACHTUNG Nur Anschlussstecker aus unserem Lieferprogramm verwenden! (Lieferumfang)

7.2.3.1 Installation fr Impulsansteuerung (Wasserzhler)


Abb. 7.12 2+4 = Impulseingang mit
potentialfreiem Kontakt
PIN Belegung
2 Schalteingang
4 GND ()

1 + 2 + 4 = Impulseingang mit
elektronischem Schalter
(NPN)
PIN Belegung
1 5 V, DC
2 Schalteingang
4 GND ()

Die minimale Impuls-, bzw.


Pausendauer betrgt 15 ms.

7.2.3.2 Installation Normsignal Ansteuerung


Abb. 7.13
4+5 = Normsignaleingang
0/4 20 mA
PIN Belegung
4 0/4-20 mA (-)
5 0/4-20 mA (+)

ACHTUNG Beim Anschluss auf richtige Polaritt achten!

417101442_KKS_E60.docx - 15 - Rev. 10-06.11


7.2.3.3 Installation Ansteuerung ber Dosiersperre
Die Dosiersperre muss zuerst im Men aktiviert werden. (siehe Kapitel 10.3.7
HINWEIS Konfiguration Dosiersperre). Die Dosiersperre steht in allen Betriebsarten zur Verfgung.
Abb. 7.14 3+4 = Eingang Dosiersperre mit
potentialfreiem Kontakt
PIN Belegung
3 Schalteingang
4 GND ()
1 +3 + 4 = Eingang Dosiersperre mit
elektronischem Schalter
(NPN)
PIN Belegung
1 5 V, DC
3 Schalteingang
4 GND ()

7.2.3.4 Installation Chargenfunktion


Die Chargenfunktion muss zuerst im Men aktiviert werden. Auerdem muss ausgewhlt
HINWEIS werden ob die Pins 2+4 (Eingang Impuls) oder 3+4 (Eingang Dosiersperre) fr den
Startimpuls der Chargendosierung genutzt werden sollen (siehe Kapitel 10.3.15)
Abb. 7.15

2+4 = Eingang Chargendosierung mit potentialfreiem Kontakt bei Wahl Eingang Impuls in
Konfiguration Charge (siehe Kapitel 10.3.15).
PIN Belegung
2 Schalteingang
4 GND ()
1 +2 + 4 = Eingang Chargendosierung mit elektronischem Schalter (NPN) bei Wahl Eingang Impuls
in Konfiguration Charge (siehe Kapitel 10.3.15).
PIN Belegung
1 5 V, DC
2 Schalteingang
4 GND ()

oder
3+4 = Eingang Chargendosierung mit potentialfreiem Kontakt bei Wahl Eingang Dosiersperre in
Konfiguration Charge (siehe Kapitel 10.3.15)
PIN Belegung
3 Schalteingang
4 GND ()
1 +3 + 4 = Eingang Chargendosierung mit elektronischem Schalter (NPN) bei Wahl Eingang
Dosiersperre in Konfiguration Charge (siehe Kapitel 10.3.15)
PIN Belegung
1 5 V, DC
3 Schalteingang
4 GND ()

417101442_KKS_E60.docx - 16 - Rev. 10-06.11


7.2.3.5 Installation Dosierberwachung
Die Funktion Dosierberwachung muss zuerst im Men aktiviert werden. Auerdem muss
HINWEIS ausgewhlt werden ob die Pins 2+4 (Eingang Impuls) oder 3+4 (Eingang Dosiersperre)
fr den Dosierberwachungs- Eingang genutzt werden sollen (siehe Kapitel 10.3.13).
Abb. 7.16

2+4 = Eingang Dosierberwachung mit potentialfreiem Kontakt bei Wahl Eingang Impuls in
Konfiguration Dosierberwachung (siehe Kapitel 10.3.13).
PIN Belegung
2 Schalteingang
4 GND ()
1 +2 + 4 = Eingang Dosierberwachung mit elektronischem Schalter (NPN) bei Wahl Eingang Impuls
in Konfiguration Dosierberwachung (siehe Kapitel 10.3.13).
PIN Belegung
1 5 V, DC
2 Schalteingang
4 GND ()

oder
3+4 = Eingang Dosierberwachung mit potentialfreiem Kontakt bei Wahl Eingang Dosiersperre
in Konfiguration Dosierberwachung (siehe Kapitel 10.3.13).
PIN Belegung
3 Schalteingang
4 GND ()
1 +3 + 4 = Eingang Dosierberwachung mit elektronischem Schalter (NPN) bei Wahl Eingang
Dosiersperre in Konfiguration Dosierberwachung (siehe Kapitel 10.3.13).
PIN Belegung
1 5 V, DC
3 Schalteingang
4 GND ()

417101442_KKS_E60.docx - 17 - Rev. 10-06.11


7.2.4 Anschlussbelegung Steckplatz III (4-polig), Ausgang fr Alarm und Hubsignal
Abb. 7.17 Aderfarbe
2 Pin Belegung
(Anschlusskabel)
1 braun Ausgang Niveauvorwarnung, Leermeldung und Strung (+)
1
2 wei Ausgang Niveauvorwarnung, Leermeldung und Strung (-)
3
3 blau Ausgang Hubsignal (+)
4 schwarz Ausgang Hubsignal (-)
4 (Steckerbelegung siehe Kapitel 14.5.3 Technische Daten)

Schutzkappe abziehen
Anschlussstecker entsprechend der Anschlussbelegung montieren.

ACHTUNG Nur Anschlussstecker aus unserem Lieferprogramm verwenden! (Lieferumfang)

7.2.4.1 Installation Niveau- bzw. Strmeldeausgang


Abb. 7.18 1+2 = Ausgang fr
Niveauvorwarnung, Niveau-
Leermeldung und Strung
Eingang Niveauvorwarnung aktiv:
Schaltausgang taktet
Eingang Niveau- Leermeldung aktiv
bzw. Strung aktiv:
Schaltausgang geschlossen (Funktion
invertierbar siehe Kapitel 10.3.9 bzw.
7.2.4.3), Schaltausgang = potentialfreier
Relaiskontakt, Belastung 24 V AC/DC 3 A
bzw. 115/230V 3A
PIN Belegung
1 Schaltausgang
2 GND ()

Bei Anschluss von 115V/230 V an Kontakt 1+2 (Alarmausgang) ist ein gleichzeitiges
ACHTUNG Nutzen von Kontakt 3+4 (Hubsignalausgang) generell nicht erlaubt.

7.2.4.2 Installation Hubsignalausgang bei 24 V / DC


Abb. 7.19

3+4 = Hubsignalausgang
Mit jedem Hub der Pumpe wird der
Schaltausgang einmal geschlossen
Schaltausgang = potentialfreier
Transistorausgang, Belastung 24 V, DC,
300 mA

PIN Belegung
3 Schaltausgang
4 GND ()

417101442_KKS_E60.docx - 18 - Rev. 10-06.11


7.2.4.3 Hardwareumstellung fr den Alarmkontakt
Abb. 7.20
Nach ffnen und Abnehmen der
Pumpenfront (Abb. 7.20) ist auf der
Steuerplatine das Alarmrelais mit
Wechselkontakt (Abb. 7.20, Pos. 1)
zugnglich.
Je nach Stellung der Brcke, kann Schlieerkontakt
sowohl der ffner, als auch der (normal open)
Schlieerkontakt als Alarmkontakt
gewhlt werden.
Setzen Sie zur Umstellung den
Jumper 3 von Pin 1 & 2 auf Pin 2 & 3. 1
Im Lieferzustand ist der
ffnerkontakt
Schlieerkontakt eingestellt.
(normal closed)

ACHTUNG:
HINWEIS nderungen an der Platine drfen ausschlielich durch Service-Personal oder
eingewiesenes Fachpersonal durchgefhrt werden!

7.2.4.3.1 Bei Konfigurationseinstellung Alarmausgang EIN


(siehe Menbeschreibung, im Kapitel 10.3.9)
Wenn Kein Alarm Wenn Alarm Power Off
Jumperstellung (Alarmrelais hat nicht (Alarmrelais hat (Alarmrelais hat nicht
angezogen) angezogen) angezogen)
Schlieerfunktion:
Kontakt offen Kontakt geschlossen Kontakt offen
(Standardeinstellung)
ffnerfunktion Kontakt geschlossen Kontakt offen Kontakt geschlossen

7.2.4.3.2 Bei Konfigurationseinstellung Alarmausgang AUS


(siehe Menbeschreibung, im Kapitel 10.3.9)
Wenn Kein Alarm Wenn Alarm Power Off
Jumperstellung (Alarmrelais hat (Alarmrelais hat nicht (Alarmrelais hat
angezogen) angezogen) angezogen)
Schlieerfunktion:
Kontakt geschlossen Kontakt offen Kontakt offen*
(Standardeinstellung)
ffnerfunktion Kontakt offen Kontakt geschlossen Kontakt geschlossen
* fail-safe Funktion, (sicher bei Ausfall)

7.2.5 Anschlussbelegung Steckplatz IV, Netzanschluss


Abb. 7.21 Der Netzanschluss erfolgt ber einen vierpoligen frontseitigen Steckverbinder.
Werkseitig ist dieser bereits mit einem Stecker verschraubt.
Pin Aderfarbe Belegung
(Anschlusskabel)
L1 schwarz Phase / Auenleiter
N blau Neutralleiter
PE gelb / grn Schutzleiter
* - nicht belegt
Um die Dichtigkeit des Netzanschlusses, gegen Feuchtigkeit zu Gewhrleisten, muss die
HINWEIS Dichtung (im Lieferumfang enthalten und im Lieferzustand bereits eingebaut) eingelegt
sein und die Fixierschraube in der Mitte des Steckers angezogen werden.
Netzanschlussleitung mit dem Stromnetz verbinden.

417101442_KKS_E60.docx - 19 - Rev. 10-06.11


8 Aufrstung der EMP KKS E60 auf EMP KKS E60PLUS
Um die EMP KKS E60 auf EMP KKS E60PLUS zu erweitern und somit auf die Zusatzfunktionen
zugreifen zu knnen ist die Dongle-Box aus unserem Zubehrprogramm (Art. Nr. 248606)
erforderlich.

8.1 Montage der Dongle-Box


Abb. 8.1 Pos. Bezeichnung
V Eingang fr Ovalradzhler
Festes Verbindungskabel fr den Anschluss des Impulseinganges an der
VI
EMP Pumpe (Eingang II)
1 Verbindungsleitung zum Anschluss an Eingang II der Pumpe
2 Dongle-Box
VII Eingang fr Chargenimpuls und Dosiersperre
VIII Eingang fr Impuls, Normsignaleingang und Dosiersperre
Abb. 8.2 Abb. 8.3

1
2
Montieren Sie die Dongle-Box (Abb. 8.1) an der dafr vorgesehenen Schiene der EMP-
Pumpe (Abb. 8.2, Pos. A):
Schieben Sie die Dongle-Box (Abb. 8.1) in die Schiene auf der linken Seite der
EMP Pumpe (Abb. 8.2, Pos A), bis diese einrastet.
Schlieen Sie das Verbindungskabel (Abb. 8.1, Pos. 1 und 8.3, Pos. 2) am Eingang fr
Impuls- /Normsignal (Abb. 8.2, Pos 1) an.
Schalten Sie die Pumpe Aus und wieder ein.
Damit sind die Zusatzfunktionen in der Dosierpumpenelektronik aktiviert und ausfhrbar.
Ist vor der Erweiterung durch eine Dongle-Box am Eingang fr Impuls- /Normsignal (siehe
HINWEIS Abb. 8.2, Pos. 1) ein Stecker angeschlossen, so kann dieser nach der Erweiterung an
Stecker VIII (siehe Abb. 8.1, Pos. VIII) der Dongle-Box angeschlossen werden.

417101442_KKS_E60.docx - 20 - Rev. 10-06.11


8.2 Anschlussbelegung der Steckpltze
8.2.1 Anschlussbelegung Steckplatz V (5-polig), Eingang fr Ovalradzhler
Abb. 8.4 Aderfarbe
Pin Belegung
(Anschlusskabel)
1 braun Ausgang 5 V DC (belastbar mit max. 50 mA)
PLUS
2 wei Busleitung fr Ovalradzhler, Typ OGM
3 blau Schalteingang
4 schwarz GND ()
5 grau Frei fr zuknftige Verwendung
Schutzkappe abziehen
Anschlussstecker entsprechend der Anschlussbelegung montieren.

ACHTUNG Nur Anschlussstecker aus unserem Lieferprogramm verwenden!

8.2.1.1 Installation Ovalradzhler (OGM oder OGMPLUS)


Plus
Die Funktion Ovalradzhler muss zuerst im Men aktiviert werden. Ist ein OGM
HINWEIS angeschlossen so wird die Funktion Ovalradzhler automatisch aktiviert
(siehe Kapitel 10.3.15).
Abb. 8.5 1 +3 + 4 = OGM bzw. andere
Durchflussberwachung
mit elektronischem
Schaltausgang
PIN Belegung
1 5V
3 Schalteingang
4 GND ()
PLUS
1 + 2 + 3+ 4 = OGM
PIN Belegung
1 5V
2 Bussignal
3 Schalteingang
4 GND ()

417101442_KKS_E60.docx - 21 - Rev. 10-06.11


8.2.2 Anschlussbelegung Steckplatz VII (5-polig)
Eingang fr Chargenimpuls und Dosiersperre
Abb. 8.6 Aderfarbe
Pin (Anschlusskabel)
Belegung
1 braun Ausgang 5 V, DC (belastbar mit max. 50 mA)
2 wei Eingang Chargendosierung
3 blau Eingang Dosiersperre
4 schwarz GND ()
5 grau Frei fr zuknftige Verwendung
Schutzkappe abziehen
Anschlussstecker entsprechend der Anschlussbelegung montieren.

ACHTUNG Nur Anschlussstecker aus unserem Lieferprogramm verwenden!

8.2.2.1 Installation Chargenimpuls


Die Chargenfunktion muss zuerst im Men aktiviert werden. Auerdem muss ausgewhlt
HINWEIS werden ob die Pins 2+4 (Eingang Impuls) oder 3+4 (Eingang Dosiersperre) fr den
Startimpuls der Chargendosierung genutzt werden sollen (siehe Kapitel 10.3.15)
Abb. 8.7

2+4 = Eingang Chargendosierung mit potentialfreiem Kontakt bei Wahl Eingang Impuls in
Konfiguration Charge (siehe Kapitel 10.3.15).
PIN Belegung
2 Schalteingang
4 GND ()
1 +2 + 4 = Eingang Chargendosierung mit elektronischem Schalter (NPN) bei Wahl Eingang Impuls
in Konfiguration Charge (siehe Kapitel 10.3.15).
PIN Belegung
1 5 V, DC
2 Schalteingang
4 GND ()

oder
3+4 = Eingang Chargendosierung mit potentialfreiem Kontakt bei Wahl Eingang Dosiersperre in
Konfiguration Charge (siehe Kapitel 10.3.15).
PIN Belegung
3 Schalteingang
4 GND ()
1 +3 + 4 = Eingang Chargendosierung mit elektronischem Schalter (NPN) bei Wahl Eingang
Dosiersperre in Konfiguration Charge (siehe Kapitel 10.3.15).
PIN Belegung
1 5 V, DC
3 Schalteingang
4 GND ()

417101442_KKS_E60.docx - 22 - Rev. 10-06.11


8.2.2.2 Installation Dosiersperre
Die Funktion Dosierberwachung muss zuerst im Men aktiviert werden. Auerdem muss
HINWEIS ausgewhlt werden ob die Pins 2+4 (Eingang Impuls) oder 3+4 (Eingang Dosiersperre)
fr den Dosierberwachungs- Eingang genutzt werden sollen (siehe Kapitel 10.3.15).
Abb. 8.8 3+4 = Eingang Dosierberwachung
mit potentialfreiem Kontakt,
bei Wahl Eingang
Dosiersperre in
Konfiguration
Dosierberwachung
(siehe Kapitel 10.3.13).
PIN Belegung
3 Schalteingang
4 GND ()
1 +3 + 4 = Eingang Dosierberwachung mit elektronischem Schalter (NPN) bei Bei Wahl Eingang
Dosiersperre in Konfiguration Dosierberwachung (siehe Kapitel 10.3.13).
PIN Belegung
1 5 V, DC
3 Schalteingang
4 GND ()

8.2.3 Anschlussbelegung Steckplatz VIII (5-polig)


Eingang fr Impuls, Normsignaleingang und Dosiersperre
Abb. 8.9 Aderfarbe
Pin (Anschlusskabel)
Belegung
1 braun Ausgang 5 V, DC (belastbar mit max. 50 mA)
2 wei Eingang Impuls
3 blau Eingang Dosiersperre
4 schwarz GND ()
5 grau Eingang Normsignal 0/4-20 mA
Schutzkappe abziehen
Anschlussstecker entsprechend der Anschlussbelegung montieren.
ACHTUNG Nur Anschlussstecker aus unserem Lieferprogramm verwenden!

8.2.3.1 Installation fr Impulsansteuerung (Wasserzhler)


Abb. 8.10 2+4 = Impulseingang mit
potentialfreiem Kontakt
PIN Belegung
2 Schalteingang
4 GND ()

1 + 2 + 4 = Impulseingang mit
elektronischem Schalter
(NPN)
PIN Belegung
1 5 V, DC
2 Schalteingang
4 GND ()

HINWEIS Die minimale Impuls-, bzw. Pausendauer betrgt 15 ms.

417101442_KKS_E60.docx - 23 - Rev. 10-06.11


8.2.3.2 Installation Normsignal (mA)
Abb. 8.11
4+5 = Normsignaleingang
0/4 20 mA
PIN Belegung
4 0/4-20 mA (-)
5 0/4-20 mA (+)

ACHTUNG Beim Anschluss auf richtige Polaritt achten!

8.2.3.3 Installation Dosiersperre


Die Dosiersperre muss zuerst im Men aktiviert werden. (siehe Kapitel: 10.3.7
HINWEIS Konfiguration Dosiersperre). Die Dosiersperre steht in allen Betriebsarten zur Verfgung.
Abb. 8.12 3+4 = Eingang Dosiersperre mit
potentialfreiem Kontakt
PIN Belegung
3 Schalteingang
4 GND ()
1 +3 + 4 = Eingang Dosiersperre mit
elektronischem Schalter
(NPN)
PIN Belegung
1 5 V, DC
3 Schalteingang
4 GND ()

417101442_KKS_E60.docx - 24 - Rev. 10-06.11


9 Inbetriebnahme
9.1 Einschalten der Pumpe
Abb. 9.1
2 sec START/STOP (mindestens 2 sec.) drcken.

9.2 Ausschalten der Pumpe


Abb. 9.2
5 sec START/STOP (mindestens 5 sec.) drcken.

9.3 Tastenfunktionen
Taste Beschreibung
Abb. 9.3
MENU/EXIT-Funktion Einstieg und Verlassen der Menebenen
(Tasten gemeinsam gedrckt halten)

()Einstellwerte nach oben verndern

() Einstellwerte nach unten verndern


Abb.9.4 Starten der Pumpe
Stoppen der Pumpe
Besttigungstaste (ENTER) fr eingestellte Werte
Abb.9.5
Testfunktion (Dauerlauf)

9.4 Displayanzeigen
Display Beschreibung
Laufmeldung der Pumpe, mit jedem Hub der Pumpe rotiert die Anzeige oben rechts im Display um
1 Umdrehung.
Niveaumeldung liegt an (blinkende Anzeige = Niveauvorwarnung, Anzeige stndig sichtbar =
Leermeldung), siehe Kapitel 7.2.2.1 Installation Sauglanze bzw. Kapitel 10.3.8 Konfiguration
Niveaukontakt
Dosiersperre aktiv, siehe Kapitel 7.2.3.3 Installation Dosiersperre bzw. Kapitel 10.3.7 Konfiguration /
Dosiersprerre.
Strung liegt an, siehe Kapitel 12.2 Strmeldungen.
Intern Betriebsart Intern, siehe Kapitel 10.2.2 Betriebsart / Intern
MUL Betriebsart Impuls Multiplikation, siehe Kapitel 10.2.3 Betriebsart / Impuls
DIV Betriebsart Impuls Division, siehe Kapitel 10.2.3 Betriebsart / Impuls
x..xx mA Betriebsart Strom x xx mA, siehe Kapitel 10.2.4 Betriebsart / Strom
Charge Betriebsart Charge siehe Kapitel 10.3.15 Konfiguration / Charge
xxx /min Anzeige Hbe/ min bei Betriebsart Intern
xx % Anzeige % bei Betriebsart Intern
x.xx l/h Anzeige l/h bei Betriebsart Intern siehe Kapitel 10.2.2.2 Displayanzeige / Einstellen Betriebsart Intern
n= x Anzeige bei Betriebsart Impuls, siehe Kapitel 10.2.3.2 Displayanzeige / Einstellen Betriebsart Impuls
xx.x mA Anzeige bei Betriebsart Strom, siehe Kapitel 10.2.4.2 Displayanzeige Betriebsart Strom
f = xx.x % Anzeige der aktuellen Dosierfrequenz in %
Pumpe ist im Betriebszustand OFF (muss eingeschaltet werden), siehe Kapitel 9.5.2 Anzeigen in der
OFF
Betriebsebene
PLUS
E60+ Donglebox angeschlossen, siehe Kapitel 8 Aufrstung auf E60
PLUS
Donglebox und OGM angeschlossen, siehe Kapitel 8.2.1.1 Installation Ovalradzhler bzw. Kapitel
E60++
10.3.11 Konfiguration / Ovalradzhler
PLUS
MicroFlow MicroFlow angeschlossen, siehe Kapitel 10.3.14 Konfiguration / MicroFlow
Alarm Betriebszustand Alarm siehe Kapitel 12.2 Strmeldungen

417101442_KKS_E60.docx - 25 - Rev. 10-06.11


9.5 Erstinbetriebnahme / Auslieferungszustand
Im Auslieferungszustand, ist die Pumpe wie folgt konfiguriert :
Betriebsmodus: Intern
Hubfrequenz: 122 Hbe/min (max. bei 50 Hz) bzw. 146 Hbe/min (max. bei 60 Hz)
Zustand: Pumpe im Betriebszustand OFF (Stand by bei V 4.0)
Zum Verndern der werksseitig vorkonfigurierten Einstellungen beachten Sie die
HINWEIS entsprechenden Menpunkte in Kapitel 10.3 Konfiguration.

9.5.1 Anzeige der Softwareversion


Abb. 9.6
Die aktuelle Softwareversion (1) wird im Display des
Hauptmens rechts oben (Abb. 9.6 & 9.7) angezeigt.
Kleinbuchstaben hinter der Softwarenummer (2)
beschreiben interne Softwarenderungen, die keinen
Einfluss auf die Bedienung des Gertes haben.
Abb. 9.7

Wurde eine Dongle-Box oder ein MicroFlowPLUS


angeschlossen, so wird die Version der Einheit (3) rechts
neben der Pumpenversion dargestellt.

9.5.2 Anzeige in der Betriebsebene


Im Auslieferzustand werden nach Anlegen der Netzspannung im Display folgende
werksseitige Grundeinstellungen angezeigt.
Abb. 9.8
Betriebsart: Intern
Dosierfrequenz / - menge in: Hbe/min (122 Hbe/min bei 50 Hz,
146 Hbe/min bei 60 Hz)
Betriebszustand: OFF (bei V 4.1, Stand by bei V 4.0)
(zum Starten START / STOP - Taste drcken)

HINWEIS Mit jedem Hub der Pumpe rotiert die Anzeige oben rechts im Display um 1 Umdrehung.

9.5.3 Konfiguration
In der Konfiguration sind werksseitig folgende Einstellungen festgelegt.
Abb. 9.9 Konfiguration von Standard siehe Kapitel
Sprache: Deutsch 10.3.3
Einheit: Liter 10.3.4
Code: nicht aktiv (-) 10.3.5
Autostart: nicht aktiv (-) 10.3.6
Dosiersperre: nicht aktiv (-) 10.3.7
Niveaukontakt: offen () 10.3.8
Alarmausgang: aus () 10.3.9
Impulsspeicher: nicht aktiv (-) 10.3.10
Ovalradzhler: nicht aktiv (-) 10.3.11
Dosierregler: nicht aktiv (-) 10.3.12
Dosierberwachung: nicht aktiv (-) 10.3.13
Microflow : nicht aktiv (-) 10.3.14
Charge: nicht aktiv (-) 10.3.15
Degas: nicht aktiv (-) 10.3.16
microflow Erscheint nur im Display in Verbindung mit der im Zubehr
erhltlichen Dosierberwachung MicroFlowPLUS.

417101442_KKS_E60.docx - 26 - Rev. 10-06.11


10 Menbeschreibung
10.1 Hauptmen
Das Hauptmen kann whrend des laufenden Betriebes der Pumpe aufgerufen werden.
Der Einstieg erfolgt durch gleichzeitiges Drcken der und Tasten.
Durch nochmaliges gleichzeitiges Drcken der und Tasten erfolgt die Rckkehr in die
Betriebsebene.

10.1.1 bersicht
Abb. 10.1

Betriebsart siehe Kapitel 10.2

Konfiguration siehe Kapitel 10.3

Kalibrierung siehe Kapitel 10.4

Betriebsdaten siehe Kapitel 10.5

417101442_KKS_E60.docx - 27 - Rev. 10-06.11


10.2 Betriebsart
10.2.1 Auswhlen
Abb. 10.2

Einstellungen siehe Kapitel:


Intern 10.2.2
Impuls 10.2.3
Strom 10.2.4

10.2.2 Betriebsart / Intern


Mit der Betriebsart intern kann die Dosierpumpe ohne externe Signale betrieben werden.
Es stehen folgende Anzeigevarianten zur Auswahl:
Hbe/min Die eingestellte Dosiergeschwindigkeit (und somit Dosiermenge)
wird in Hbe/min angezeigt. (Standardeinstellung)
Prozent Die eingestellte Dosiergeschwindigkeit (und somit Dosiermenge)
wird in Prozent angezeigt.
Liter* Die eingestellte Dosiermenge wird in Liter / h
(wahlweise auch in Gallone / Tag bzw. Gallone / h) angezeigt.
* Umstellung von Liter auf Gallone, siehe Kapitel 10.3.4

10.2.2.1 Auswhlen
Abb. 10.3

417101442_KKS_E60.docx - 28 - Rev. 10-06.11


10.2.2.2 Displayanzeige in der Betriebsebene / Einstellen
Die Ein-/Verstellung der Dosiermenge kann in der Betriebsebene whrend des laufenden
Betriebes vorgenommen werden.
Wenn der neu eingestellte Wert nicht innerhalb von 10 Sekunden durch Drcken der
HINWEIS START/STOP-Taste besttigt wird, bleibt der ursprngliche Wert erhalten.
Hbe/min
Abb. 10.4

Prozent (%)
Abb. 10.5

Liter Gallon
Abb. 10.6 Abb. 10.7

10.2.3 Betriebsart: Impuls


Bei Betriebsart Impuls arbeitet die Dosierpumpe nur in Verbindung mit eingehenden
Impulsen (z. B. von einem Kontaktwasserzhler).
Folgende Impulsverarbeitungvarianten stehen zur Auswahl:
Multiplikation Eingehende Impulse werden mit einem einstellbarem Faktor (n) multipliziert:
1 Impuls = n Pumpenhbe (Standardeinstellung)
Division Eingehende Impulse werden durch einen einstellbarem Faktor (n) dividiert:
n Impulse = 1 Pumpenhub

417101442_KKS_E60.docx - 29 - Rev. 10-06.11


10.2.3.1 Auswhlen
Abb. 10.8

10.2.3.2 Displayanzeige in der Betriebsebene/ Einstellen


Die Ein- / Verstellung des Multiplikations- bzw. Divisionsfaktors erfolgt in der Betriebsebene
und kann whrend des laufenden Betriebes der Pumpe vorgenommen werden.
Multiplikation
Abb. 10.9

Wenn der neu eingestellte


Wert nicht innerhalb von
10 Sekunden durch
HINWEIS Drcken der START/STOP -
Division Taste besttigt wird, bleibt
Abb. 10.10 der zuvor eingestellte,
laufende Wert erhalten.

417101442_KKS_E60.docx - 30 - Rev. 10-06.11


10.2.4 Betriebsart / Strom (Extern-Normsignal)
Bei Betriebsart Strom arbeitet die Pumpe in Abhngigkeit von einem eingehenden
Normsignal. Das eingehende Signal (0/4-20 mA; 20-0/4 mA oder einstellbar) wird in eine
Dosierfrequenz 0-100 % (Hub/Pausenverhltnis) umgesetzt.
Folgende Betriebsvarianten stehen zur Auswahl:
0 20 mA 0 mA = 0% Dosierfrequenz, 20 mA = 100 % Dosierfrequenz
4 20mA 4 mA = 0% Dosierfrequenz, 20 mA = 100 % Dosierfrequenz
20 0 mA 20 mA = 0% Dosierfrequenz, 0 mA = 100 % Dosierfrequenz
20 4 mA 20 mA = 0% Dosierfrequenz, 4 mA = 100 % Dosierfrequenz
beliebig n (einstellbar) mA = 0 % Dosierfrequenz,
n (einstellbar) mA = 100 % Dosierfrequenz

10.2.4.1 Auswhlen
Abb. 10.11

siehe Kapitel 10.2.4.1.1

417101442_KKS_E60.docx - 31 - Rev. 10-06.11


10.2.4.1.1 Einstellen Betriebsart / Strom / beliebig
HINWEIS Die Differenz der eingestellten Werte muss grer oder gleich 5 sein (z.B. min. 10 max. 15).
Abb. 10.12

10.2.4.2 Displayanzeige in der Betriebsebene


Displayanzeige Pos Bezeichnung
Abb. 10.13
1 Im Men voreingestellter Arbeitsbereich

2 Aktuell anliegender Stromwert

3 Hubfrequenz in %

10.3 Konfiguration
10.3.1 bersicht
Abb. 10.14 Konfiguration von: siehe Kapitel:
Mensprache 10.3.3
Einheiten 10.3.4
Codeeingabe 10.3.5
Starteinstellungen 10.3.6
Dosiersperre 10.3.7
Niveaukontakt 10.3.8
Alarmausgang 10.3.9
Impulsspeicher 10.3.10
Ovalradzhler 10.3.11
Dosierregler 10.3.12
Dosierberwachung 10.3.13
MicroFlow 10.3.14
Dieser Menpunkt erscheint nur in Verbindung mit der
als Zubehr erhltlichen Dosierberwachung MicroFlow
und ersetzt den Menpunk Dosierberwachung.
Charge 10.3.15
Degas 10.3.16

417101442_KKS_E60.docx - 32 - Rev. 10-06.11


10.3.2 Display Rollen
Abb. 10.15 Das Display verfgt ber eine Roll-Funktion, d.h., das im Display
einige Menpunkte erst angezeigt werden, wenn das Menende im
Display erreicht ist. Anhand der Symbolik (1) oder (2) im
Display ist erkennbar, in welche Richtung gerollt werden kann.
1 = () Displayanzeige nach oben rollen
2 = () Displayanzeige nach unten rollen

10.3.3 Konfiguration / Sprache


Hier wird die Sprache fr die Menfhrung ausgewhlt.

10.3.3.1 Auswhlen
Abb. 10.16

Standardeinstellung = Deutsch

10.3.4 Konfiguration / Einheit


Ist bei Betriebsart / Intern die Anzeigevariante Liter gewhlt (siehe Kapitel 10.2.2) kann hier
die Anzeige von Liter / h auf Gallone / Tag (1 Gallone = 3,785 Liter) umgestellt werden.

10.3.4.1 Auswhlen
Abb. 10.17

Standardeinstellung = Liter

417101442_KKS_E60.docx - 33 - Rev. 10-06.11


10.3.5 Konfiguration / Code
In dieser Einstellung kann eine Zahlenkombination zur Sicherung der Einstellwerte
gegenber unerlaubtem Verstellen vergeben werden.
Ist Code aktiviert muss vor jeder Vernderung eines Einstellwertes bzw. vor Wechsel in
das Hauptmen der entsprechende vierstellige Code eingegeben werden.

10.3.5.1 Auswhlen
Abb. 10.18

- Codeabfrage inaktiv.
(Standardeinstellung)

Codeabfrage aktiv.

siehe Kapitel 10.3.5.2

10.3.5.2 Einstellen
Abb. 10.19

10.3.6 Konfiguration / Autostart


Diese Funktion bestimmt ob die Pumpe bei Wiederanlegen der Netzspannung nach
Spannungsausfall in den Betriebszustand OFF (Stand by bei V 4.0) geht, oder ob die
Pumpe sofort in der eingestellten Betriebsart weiterlaufen soll.

417101442_KKS_E60.docx - 34 - Rev. 10-06.11


10.3.6.1 Auswhlen
Abb. 10.20

- Autostart ist inaktiv.


Die Pumpe geht bei Anlegen der
Netzspannung in den Betriebszustand
OFF (Stand by bei V 4.0)
(Standardeinstellung)

Autostart ist aktiv.


Die Pumpe geht bei Anlegen der
Netzspannung in den aktuell
eingestellten Betriebszustand.

10.3.7 Konfiguration / Dosiersperre


Bei aktivierter Dosiersperre luft die Pumpe nur wenn an Stecker II (oder an Stecker VII bzw.
Stecker VIII bei Verwendung einer Dongle Box) zwischen PIN 3+4 ein externer
Freigabekontakt geschlossen ist (elektrischer Anschluss siehe Kapitel 7.2.3.3 bzw. 8.2.2.2
bzw. 8.2.3.3). Die Nutzung der Dosiersperre ist dabei unabhngig von der gewhlten
Betriebsart.

10.3.7.1 Auswhlen
Abb. 10.21

- Abfrage der Dosiersperre inaktiv.


(Standardeinstellung)

Abfrage der Dosiersperre aktiv.

10.3.8 Konfiguration / Niveaukontakt


Hiermit wird festgelegt ob am Niveaueingang (Stecker I siehe Kapitel 7.2.2.1) ein offener
oder ein geschlossener Kontakt als Niveau i. O. angesehen wird.

417101442_KKS_E60.docx - 35 - Rev. 10-06.11


10.3.8.1 Auswhlen
Abb. 10.22

= Kontakt offen:
Niveau n.i.O. (leer)
Kontakt geschlossen:
Niveau i.O. (voll)
(Standardeinstellung)

= Kontakt geschlossen:
Niveau n.i.O. (leer)
Kontakt offen:
Niveau i.O. (voll)

10.3.9 Konfiguration / Alarmausgang


Diese Option ermglicht die Invertierung des Alarmausganges (Alarmausgangs - Relais hat
bei Alarm angezogen oder nicht angezogen).

10.3.9.1 Auswhlen
Abb. 10.23

= Bei Alarm hat das Relais fr den


Alarmausgang angezogen.
(Standardeinstellung)
= Bei Alarm hat das Relais fr den
Alarmausgang nicht angezogen.
Zustzlich zur Funktionsweise des
Relais kann auch noch ausgewhlt
werden ob bei angezogenem Relais
der Kontakt des Alarmausgangs-
Relais geschlossen (Schlieerfunktion,
Standardeinstellung) oder offen
(ffnerfunktion) sein soll
(siehe Kapitel 7.2.4.3 Umstellung
Funktionsweise Alarmrelais- Kontakt).

10.3.9.2 Umstellung Funktionsweise Alarmrelais-Kontakt


Siehe Kapitel 7.2.4.3

417101442_KKS_E60.docx - 36 - Rev. 10-06.11


10.3.10 Konfiguration / Impulsspeicher
Sollte die eingehende Impulsrate hher sein als die max. von der Pumpe verarbeitbare
Impulsrate (max. Pumpenfrequenz, z.B. 122 Hbe/min bei 50 Hz) besteht die Mglichkeit die
nicht verarbeiteten Impulse zu speichern.
Die gespeicherten Impulse werden abgearbeitet nachdem keine externen Impulse mehr
eingehen. D.h. die Pumpe luft weiter obwohl keine externe Laufbedingung vorliegt.
ACHTUNG Im ungnstigsten Fall kann das dazu fhren, dass in ein geschlossenes System dosiert
wird und somit ein unzulssig hoher Druck im System entsteht.
Das muss durch entsprechende Sicherungsmanahmen verhindert werden.
Der Speicherinhalt kann durch Aktivieren der Dosiersperre oder Ausschalten der Pumpe
gelscht werden.

10.3.10.1 Auswhlen
Abb. 10.24

- Der Impulsspeicher ist inaktiv.


(Standardeinstellung)

Der Impulsspeicher ist aktiv.

10.3.10.2 Displayanzeige in der Betriebsebene bei aktiviertem Impulsspeicher


Displayanzeige im Betrieb Bedeutung Pos Bezeichnung
Abb. 10.25 1 Impulsspeicher aktiv
Impulsmultiplikation 2 Anzahl der eingegangenen Impulse
3 Eingestellter Faktor
(Beispiel: aus 10
externen Impulsen
werden 20 Hbe)

Abb. 10.26
Impulsdivision
(Beispiel: aus 10
externen Impulsen
werden 5 Hbe)

417101442_KKS_E60.docx - 37 - Rev. 10-06.11


10.3.11 Konfiguration / Ovalradzhler (nur E60PLUS & OGM bzw. OGM PLUS)
Die Funktion Ovalradzhler ermglicht eine echte Mengenerfassung bei Menpunkt
Betriebsdaten / Liter (siehe Kapitel 10.5.3).
Zudem ist die Aktivierung dieses Menpunktes Voraussetzung um die Funktion Dosierregler
(siehe Kapitel 10.3.12) nutzen zu knnen.
Die Funktion Ovalradzhler kann nur aktiviert werden, wenn die Pumpe durch eine Dongle-
PLUS
Box zur E60 erweitert und ein Ovalradzhler (siehe Zubehr) angeschlossen wurde.
Zur Aktivierung der Dongle-Box in Verbindung mit dem Ovalradzhler, muss die
HINWEIS Netzspannung getrennt und neu hergestellt werden. (Netzstecker ziehen oder die Pumpe
Aus- und wieder Einschalten!)
PLUS
Bei Anschluss eines OGM wird die Funktion Ovalradzhler automatisch aktiviert.

10.3.11.1 Auswhlen
Abb. 10.27

- Der Ovalradzhler ist inaktiv.


(Standardeinstellung)

Der Ovalradzhler ist aktiv

10.3.12 Konfiguration / Dosierregler (nur E60PLUS & OGMPLUS)


Abb. 10.28

Ist ein OGMPlus angeschlossen, so wird mit Aktivierung der Dosierregler-Funktion die durch
den OGM gemessene Dosiermenge mit einem eingestellten Dosiermengen-Sollwert
verglichen. Ergibt sich hierbei eine Abweichung wird die Dosierfrequenz der Pumpe
automatisch erhht bzw. vermindert.
Da die Nachregelung der Dosierfrequenz nur innerhalb der Leistungsgrenzen der Pumpe
mglich ist, empfiehlt es sich die Dosiermengenvorgabe auf hchstens 80 - 90 % der
maximal mglichen Dosierfrequenz einzustellen. Dadurch hat der Dosierregler nach oben
hin Reserven um auf negative Regelabweichungen zu reagieren.
Die Dosierregler-Funktion kann nur in den Betriebsarten Intern und Strom genutzt
werden. Ist die Betriebsart Impuls eingestellt, so ist die Dosierregler-Funktion auer
Betrieb.
Die Dosierreglerfunktion kann nur aktiviert werden, wenn die Pumpe durch eine Dongle-
PLUS PLUS
Box zur E60 erweitert und ein Ovalradzhler, Typ OGM (siehe Zubehr)
HINWEIS angeschlossen wurde. Zur Aktivierung der Dongle-Box in Verbindung mit dem
Ovalradzhler, muss die Pumpe aus- und wieder eingeschaltet werden!

417101442_KKS_E60.docx - 38 - Rev. 10-06.11


10.3.12.1 Auswhlen
Abb. 10.29

- Die Reglerfunktion ist inaktiv.


(Standardeinstellung)

Die Reglerfunktion ist aktiv.

10.3.12.2 Displayanzeige in der Betriebsebene bei aktiviertem Dosierregler


Abb. 10.30 = Dosierabweichung nach unten
Die Pumpe frdert aktuell weniger, als die voreingestellte
Hubfrequenz (hier beispielsweise 100/min) verlangt.
Die Dosierfrequenz wird automatisch erhht, bis der Wert
angeglichen ist.
Abb. 10.31
- = Keine Dosierabweichung
Die Pumpe frdert exakt die Menge, die voreingestellt (hier
beispielsweise 100/min) ist.
Eine Nachregelung zur Korrektur ist nicht erforderlich.
Abb. 10.32 = Dosierabweichung nach oben
Die Pumpe frdert aktuell mehr, als die voreingestellte
Hubfrequenz (hier beispielsweise 100/min) verlangt.
Die Dosierfrequenz wird automatisch abgesenkt, bis der Wert
angeglichen ist.
Abb. 10.33
Dongle-Box montiert.
HINWEIS
Ovalradzhler OGMPLUS montiert.

10.3.13 Konfiguration / Dosierberwachung


Bei aktivierter Dosierberwachung erfolgt ein Vergleich zwischen den gettigten
Pumpenhben und den eingehenden Impulsen einer externen Dosierberwachung (z. B.
Ovalradzhler). Wird dabei eine einstellbare Toleranzgrenze berschritten erfolgt eine
Alarmmeldung.
Die Durchflussberwachungseinheit kann bei Stecker II (oder Stecker V bei Verwendung
einer Dongle Box) an Pin 2+4 (Impulseingang) oder an Pin 3+4 (Eingang Dosiersperre)
angeschlossen werden (Auswahl Eingang siehe Kapitel 10.3.13.5, elektrischer Anschluss
siehe Kapitel 7.2.3.5 bzw. 8.2.1.1).
Wenn ein Ovalradzhler als Dosierberwachungseinheit angeschlossen ist und
entsprechend ausgewertet werden soll, dann muss neben Konfiguration /
HINWEIS Dosierberwachung auch die Funktion Konfiguration / Ovalradzhler aktiviert sein
(siehe Kapitel 10.3.11).

417101442_KKS_E60.docx - 39 - Rev. 10-06.11


10.3.13.1 Auswhlen
Abb. 10.34

- Dosierberwachung inaktiv.
(Standardeinstellung)

Dosierberwachung aktiv.

Mit Aktivierung der


Dosierberwachung erscheint ein
Untermen mit folgenden
Punkten:
Menpunkt siehe Kapitel
Pumpe stoppen 10.3.13.2
Hbe 10.3.13.3
Abweichung 10.3.13.4
Eingang 10.3.13.5

10.3.13.2 Dosierberwachung / Pumpe stoppen


Mit Pumpe stoppen wird eingestellt, ob die Pumpe bei Alarm Dosierberwachung
gestoppt werden soll oder weiterluft.
Abb. 10.35

- Die Pumpe wird bei:


Alarm: Dosierberwachung
nicht gestoppt. (Standardeinstellung)

Die Pumpe wird bei:


Alarm: Dosierberwachung
gestoppt.

10.3.13.3 Dosierberwachung / Hbe


Die Option Hbe gibt das zu berwachende Intervall an Hben an
Einstellbereich: 0 100
Abb. 10.36

Standardeinstellung = 10

417101442_KKS_E60.docx - 40 - Rev. 10-06.11


10.3.13.4 Dosierberwachung / Abweichung (nur bei E60PLUS & OGM bzw. OGMPLUS)
Bei Abweichung wird eine Toleranz in % eingestellt.
Die vom Ovalradzhler eingehende tatschliche Impulsrate innerhalb des zu
berwachenden Pumpenintervalls (siehe 10.3.13.3 Konfiguration / Hbe) wird mit einer bei
der Kalibrierung ermittelten Soll- Impulsrate verglichen.
Sollte bei diesem Vergleich eine Abweichung grer dem unter Abweichung eingestellten
%- Wert herauskommen, so wird Alarm Dosierberwachung ausgegeben.
Diese Funktion kann nur ausgewhlt werden wenn eine Dongle Box angeschlossen ist und
HINWEIS wenn Konfiguration / Ovalradzhler (siehe Kapitel 10.3.11) aktiviert wurde.
Abb. 10.37

Einstellbereich: 0-100%

Standardeinstellung = 20 %

10.3.13.5 Dosierberwachung / Eingang (nur bei E60 OHNE Dongle-Box)


Mit der Einstellung Eingang wird festgelegt ber welchen Eingang (Impulseingang oder
Dosiersperre) an Stecker II (oder an Stecker V bei Verwendung einer Dongle Box) der
Pumpe die eingehenden Impulse von der Dosierberwachungseinheit ausgewertet werden
sollen.
Je nach ausgewhltem Eingang muss dann die Durchflussberwachung unterschiedlich
angeschlossen werden:
Eingang Impuls: = Stecker II (oder Stecker V) Pin 2+4
Eingang Dosiersperre: = Stecker II (oder Stecker V) Pin 3+4
Siehe Kapitel 7.2.3.5.
Diese Funktion kann nur ausgewhlt werden wenn keine Dongle Box angeschlossen ist.
HINWEIS Die ursprngliche Funktion (z.B. Impulseingang) kann dann nicht mehr genutzt werden.
Abb. 10.38

417101442_KKS_E60.docx - 41 - Rev. 10-06.11


10.3.13.6 Anzeige der Ovalradzhler-Impulse (nur E60+)
Abb. 10.39 Hier wird die Anzahl an Impulsen angezeigt, die bei
der letzen Kalibrierung ermittelt wurde (Laufzeit bei
der Kalibrierung = 1min).
Steht hier ein Wert kleiner 60, so ist eine
Dosierberwachung mit Ovalradzhler nur
eingeschrnkt mglich.

10.3.14 Konfiguration / MicroFlowPLUS


PLUS
Bei Anschluss der Dosierberwachungseinheit MicroFlow (Art. Nr. 248611) an
Stecker II der Pumpe und Aktivierung der Plug & Play - Funktion durch kurzzeitige
Wegnahme der Versorgungsspannung oder Aus und wieder Ein-Schalten der Pumpe wird
HINWEIS automatisch der Menpunkt Konfiguration / Dosierberwachung durch Konfiguration /
MicroFlow ersetzt.
PLUS
Zur Installation / Inbetriebnahme des Dosierberwachungssystems MicroFlow beachten
Sie bitte die dazugehrige Bedienungsanleitung Art. Nr. 417101314.
Diese Funktion ermglicht eine Dosierberwachung bei der mit jedem Pumpenhub ein
Dosierimpuls abgegeben und entsprechend ausgewertet wird.
Die hinterlegten Standardeinstellungen fr Hbe, Abweichung, Dosierpause und
Dosierverzgerung knnen nur als Voreinstellung gesehen werden.
HINWEIS Die Empfindlichkeit des MicroFlow Systems muss je nach Ausfhrung der Anlage (z.B. Art
der Chemikalie, Dosiermenge, Querschnitte, Leitungslngen) durch Verndern der o.g.
Parameter individuell an die Vor-Ort-Verhltnisse angepasst werden.

10.3.14.1 Auswhlen
Abb. 10.40
PLUS
- MicroFlow ist inaktiv
(Standardeinstellung)
PLUS
MicroFlow ist aktiv

PLUS
Mit Aktivierung der MicroFlow
erscheint ein Untermen mit
folgenden Punkten:
Menpunkt siehe Kapitel
Pumpe stoppen 10.3.14.2
Hbe 10.3.14.3
Abweichung 10.3.14.4
Dosierpause 10.3.14.5
Dosierverzgerung 10.3.14.6
Kalibrierung 10.3.14.7

417101442_KKS_E60.docx - 42 - Rev. 10-06.11


10.3.14.2 MicroFlowPLUS / Pumpe stoppen
Abb. 10.41
Mit Pumpe stoppen wird
eingestellt ob die Pumpe bei
Alarm Dosierberwachung
gestoppt wird oder weiterluft.
- Die Pumpe wird nicht gestoppt,
bei Alarm
Dosierberwachung
(Standardeinstellung)

Die Pumpe wird gestoppt bei


Alarm Dosierberwachung

10.3.14.3 MicroFlowPLUS / Hbe


Abb. 10.42

Die Option Hbe gibt das zu


berwachende Intervall an Hben
an.
Einstellbereich: 0-100

Standardeinstellung = 40 Hbe

10.3.14.4 MicroFlowPLUS / Abweichung


Die Option Abweichung gibt an, welche Anzahl an nicht erkannten Hben in dem zu
berwachenden Hubintervall (siehe Kapitel 10.3.14.3 MicroFlowPLUS / Hbe) erlaubt ist,
bevor die Dosierberwachung einen Alarm ausgibt.
Abb. 10.43

Beispiel: Hbe 40; Abweichung 20


In diesem Beispiel werden in
einem Intervall von 40 Hben 20
nicht erkannte Hbe akzeptiert.
Werden 21 Hbe nicht erkannt, so
wird ein Alarm ausgegeben.
Einstellbereich: 0-100

Standardeinstellung = 20

417101442_KKS_E60.docx - 43 - Rev. 10-06.11


10.3.14.5 MicroFlowPLUS / Dosierpause
Bei Umgang mit Medien, die zur Ausgasung neigen bilden sich nach lngeren
Stillstandszeiten Gaseinschlsse im System, die zur Verflschung der zu dosierenden
Menge und im weiteren Verlauf zu einem Nichterkennen der Dosierhbe durch das
MicroFlowPLUS und somit zu einem Alarm fhren.
Abb. 10.44
Mit Dosierpause wird die Zeit
eingestellt, nach deren Ablauf
ohne Dosiervorgang die
berwachung fr eine bestimmte
Zeit (siehe 10.3.14.6
MicroFlowPLUS /
Dosierverzgerung) deaktiviert
wird um ein ungewolltes
Ansprechen der berwachung zu
verhindern.
Einstellbereich: 2 - 3600s

Standardeinstellung = 240 Sec.

10.3.14.6 MicroFlowPLUS / Dosierverzgerung


Unter Dosierverzgerung wird die Zeit eingegeben whrend der bei Umgang mit
ausgasenden Medien bei einer Dosierung die Dosierberwachung auer Betrieb gesetzt
wird um eine Entgasung des Systems zu gewhrleisten.
Die Dosierverzgerung wird aktiv sobald nach Ablauf der Dosierpause
(siehe Kapitel 10.3.14.5) eine Dosierung stattfindet.
Beispiel: Dosierpause 240 s; Dosierverzgerung 40 s;
In diesem Beispiel wird nach einer Zeit von 240 Sekunden, in der keinerlei Dosierung erfolgte
(Dosierpause) mit der nchsten Dosieranforderung eine Zeit von 40 Sekunden gestartet
(Dosierverzgerung), in der die Dosierberwachung des MicroFlowPLUS unterbrochen ist
Abb. 10.45

In dieser Zeit knnen eventuell


entstandene Gasblasen aus dem
System gefrdert werden ohne
einen Alarm auszulsen.

Einstellbereich: 2 - 3600s

Standardeinstellung = 40 Sec.

417101442_KKS_E60.docx - 44 - Rev. 10-06.11


10.3.14.7 MicroFlowPLUS / Kalibrierung
Mit der Option Kalibrierung wird der Messwertaufnehmer bei der Erstinstallation oder bei
einem Produktwechsel neu kalibriert.
Whrend der Kalibrierung muss die Pumpe mit der gewnschten Einstellung
WICHTIG laufen und das Dosiermedium muss blasenfrei durch den Messwertaufnehmer
strmen.
Mit Aktivierung von Kalibrierung werden die Werte fr min. Leitfhigkeit (leitende
Verbindung zwischen den Sensorstiften im Messwertaufnehmer unterbrochen) und max.
Leitfhigkeit (leitende Verbindung) ermittelt.
Abb. 10.46

Aus diesen beiden Werten wird dann


eine Differenz errechnet und angezeigt.
Fr eine gute berwachbarkeit sollte die
Differenz grer als 3..4 sein.

10.3.15 Konfiguration Charge


HINWEIS Die Pumpe muss vor Verwendung der Chargendosierung kalibriert werden. (siehe Kapitel: 10.4)

Bei aktiviertem Chargenmodus wird durch ein Startsignal an Stecker II (oder an Stecker VII
bei Verwendung einer Dongle Box) Pin 2+4 (Impulseingang) oder PIN 3+4 (Eingang
Dosiersperre) eine vorher definierte Menge mit 100 % Hubfrequenz dosiert (Auswahl
Eingang siehe Kapitel 10.3.15.3, elektrischer Anschluss siehe Kapitel 7.2.3.4 bzw.
Kapitel 8.2.2.1).
Die Chargendosierung kann durch Deaktivieren der Freigabe (Dosiersperre) oder durch
Ausschalten der Pumpe abgebrochen werden.

10.3.15.1 Auswhlen
Abb. 10.47

- Charge ist inaktiv


(Standardeinstellung)

Charge ist aktiv

Bei aktivierter Chargendosierung


erscheinen folgende Punkte im
Untermen:
Menpunkt Kapitel
Menge 10.3.15.2
Eingang 10.3.15.3

417101442_KKS_E60.docx - 45 - Rev. 10-06.11


10.3.15.2 Charge / Menge
Mit Menge wird die gewnschte Dosiermenge (in l, ml, l oder G) pro Chargendosiervorgang
festgelegt. Einstellbereich: 0 99999
Abb. 10.48

417101442_KKS_E60.docx - 46 - Rev. 10-06.11


10.3.15.3 Charge / Eingang (nur bei E60 OHNE Dongle-Box)
Mit der Einstellung Eingang wird festgelegt ber welchen Eingang (Impulseingang oder
Dosiersperre) an Stecker II (oder Stecker VII bei Verwendung einer Dongle Box) der Pumpe
der Startimpuls fr die Chargendosierung ausgewertet werden sollen.
Je nach ausgewhltem Eingang muss dann das Kabel fr den Startimpuls unterschiedlich
angeschlossen werden:
Eingang Impuls = Stecker II (oder Stecker VII) Pin 2+4
Eingang Dosiersperre = Stecker II (oder Stecker VII) Pin 3+4
Siehe Kapitel 7.2.3.4 und 8.2.2.1
Die ursprngliche Funktion (z.B. Impuls) kann dann nicht mehr genutzt werden!
HINWEIS Bei Verwendung einer Dongle-Box steht ein separater Eingang zur Verfgung.
Abb. 10.49

Standardeinstellung = Dosiersperre

10.3.15.4 Displayanzeige in der Betriebsebene


Abb. 10.50 Pos Bezeichnung
1 Betriebsart
2 Noch zu dosierende Menge
3 Verbleibende, noch zu ttigende Hbe

10.3.16 Konfiguration DegasPLUS


Bei Aktivierung der DegasPLUS Funktion und Anschluss eines entsprechenden
Entgasungsventils ermglicht diese Funktion eine zeitlich gesteuerte Entgasung des
Dosiersystems. Fr Installation / Inbetriebnahme des Entgasungsventils beachten Sie bitte
die zugehrige Bedienungsanleitung, Art. Nr. 417101377.

417101442_KKS_E60.docx - 47 - Rev. 10-06.11


10.3.16.1 Auswhlen
Abb. 10.51

PLUS
- Degas ist inaktiv
(Standardeinstellung)

PLUS
Degas ist aktiv

Bei aktivierter
Entgasungssteuerung erscheinen
folgende Punkte im Untermen:
Menpunkt siehe Kapitel
Degas Hbe 10.3.16.2
Degas Pause 10.3.16.3

10.3.16.2 Degas / Degas Hbe


Abb. 10.52

Unter Degas Hbe wird die Anzahl


an Hben eingestellt, die bei einem
Entgasungsintervall abgearbeitet
werden sollen.
Einstellbereich: 1-100

Standardeinstellung = 0

417101442_KKS_E60.docx - 48 - Rev. 10-06.11


10.3.16.3 Degas / Degas Pause
Unter Degas Pause wird die Zeit zwischen zwei Entgasungsintervallen eingestellt.
Sollte whrend dieser Zeit eine Dosieranforderung kommen wird diese abgearbeitet und die
DegasPLUS- Pausenzeit wird zurckgesetzt und neu gestartet.
Einstellbereich: Stunden: 00 - 23
Minuten 00 - 59
ges. 00.01 - 23.59h
Abb. 10.53

Standard-
einstellung =
00:00

10.4 Kalibrierung
10.4.1 bersicht
Abhngig davon ob ein Ovalradzhler angeschlossen ist oder nicht, unterscheiden sich
Vorgehensweise und Displayanzeige bei der Kalibrierung.
Abb. 10.54
Kalibrierung Pumpe:
siehe Kapitel 10.4.2
Kalibrierung Pumpe mit
Ovalradzhler:
siehe Kapitel 10.4.3

417101442_KKS_E60.docx - 49 - Rev. 10-06.11


10.4.2 Kalibrierung Pumpe
10.4.2.1 Vorbereitung
Abb. 10.55

Pumpe druckseitig betriebsfertig


anschlieen.
(siehe Kapitel 7 Gerteinstallation).
Geeigneten Messzylinder befllen und
Saug - bzw. Saug- und Rcklaufleitung
einfhren.

Das Volumen des Messzylinders sollte 1/50 der Dosierpumpenleistung in Liter/h betragen.
Whrend des Kalibriervorgangs, darf der Saugschlauch in seiner Lage nicht verndert
HINWEIS werden. Die Kalibrierung der Dosierpumpe ist nur fr die aktuell eingestellte
Hublngeneinstellung gltig. Nach Vernderung der Hublnge ist, die Kalibrierung erneut
durchzufhren.

10.4.2.2 Kalibrierung / Starten


Abb. 10.56

Zu : Die Pumpe luft 122 Hbe lang (ca. 1 min).


Die Hbe werden von 122 rckwrts bis 0 gezhlt.
HINWEIS Durch Bettigung der Menu/Exit-Funktion kann die Kalibrierung abgebrochen werden.

Zu : Nach Ablaufende muss die aus dem Messzylinder (siehe Kapitel 10.4.2.1
Vorbereitung) entnommene Menge abgelesen werden.
Diese Menge wird dann als Kalibrierwert (in ml bzw. l) eingegeben.

10.4.3 Kalibrierung Pumpe mit Ovalradzhler (OGMPLUS)


Falls eine Dongle Box und ein Ovalradzhler angeschlossen und in der Konfiguration die
Funktion Ovalradzhler (siehe Kapitel 10.3.11) aktiviert ist, wird nach dem Kalibrierlauf
automatisch die ermittelte Ovalradzhler - Impulsrate angezeigt.
Diese wird mit dem eingegebenen Kalibrierwert verrechnet. Dadurch erfolgt eine Zuordnung
zwischen Ovalradzhler- Impulsen und dosierter Menge.

417101442_KKS_E60.docx - 50 - Rev. 10-06.11


10.4.3.1 Vorbereitung
Abb. 10.57

Pumpe druckseitig betriebsfertig


anschlieen (siehe Kapitel 7
Gerteinstallation).
geeigneten Messzylinder befllen und
Saug- bzw. Saug- und Rcklaufleitung
einfhren.

Das Volumen des Messzylinders sollte 1/50 der Dosierpumpenleistung in Liter/h betragen.
Whrend des Kalibriervorgangs, darf der Saugschlauch in seiner Lage nicht verndert
HINWEIS werden. Die Kalibrierung der Dosierpumpe ist nur fr die aktuell eingestellte
Hublngeneinstellung gltig. Nach Vernderung der Hublnge ist, die Kalibrierung erneut
durchzufhren.

10.4.3.2 Kalibrierung / Starten


Abb. 10.58

Zu : Die Pumpe luft 122 Hbe lang (ca. 1 min).


Die Hbe werden von 122 rckwrts bis 0 gezhlt.
Die Ovalradzhlerimpulse (OGM Impulse) werden von 0 hoch gezhlt.
Durch Bettigung der 'Menu/Exit-Funktion kann die Kalibrierung abgebrochen werden.
HINWEIS Sollten hier die OGM Impulse nicht angezeigt werden, berprfen Sie alle
Steckerverbindungen an der Pumpe!

Zu : Nach Ablaufende muss die aus dem Messzylinder (siehe Kapitel 10.4.2.1
Vorbereitung) entnommene Menge abgelesen werden.
Diese Menge wird dann als Kalibrierwert (in ml bzw. l) eingegeben.
Abb. 10.59

Whrend des Kalibrierlaufes werden die ermittelten


Ovalradzhlerimpulse im Display angezeigt.

417101442_KKS_E60.docx - 51 - Rev. 10-06.11


10.4.4 Kalibrierung / Manuell
Wenn der einzugebende Kalibrierwert bekannt ist kann hier eine Trockenkalibrierung
(sofortige Eingabe des Wertes ohne vorherigen Kalibrierlauf) vorgenommen werden.
Diese Methode ist allerdings nicht sehr genau, da die Vor- Ort- Verhltnisse (Gegendruck,
Viskositt; Leitungsquerschnitte und - lngen usw.) nicht bercksichtigt werden.
Abb. 10.60

10.4.4.1 Tabelle Kalibrierdaten


Mit den in der Tabelle angegebenen Kalibrierwerten wird der Elektronik der Pumpe die
jeweilige Pumpenleistung in l/h zugeordnet.
Beispiel:
Ein eingegebener Wert von 23,3 ml ergibt eine Pumpenleistung von 1,4 l/h.
HINWEIS Diese Werte beziehen sich auf Dosiermedium Wasser bei 20C

Pumpenleistung [l/h] Kalibrierwert Pumpe [ml]


Pumpe bei 50 (60) Hz bei 50 (60) Hz
0,2 (0,24) 3,33 (4,00)
KKS

0,5 (0,6) 8,33 (10,0)


Abb. 10.61
0,9 (1,1) 15,0 (18,3)
1,4 (1,7) 23,3 (28,3)

10.5 Betriebsdaten
Unter diesem Menpunkt werden folgende Betriebsdaten erfasst und angezeigt:
Betriebsstunden
Liter
Impulsanzahl

417101442_KKS_E60.docx - 52 - Rev. 10-06.11


10.5.1 bersicht
Abb. 10.62

siehe Kapitel 10.5.2

siehe Kapitel 10.5.3

siehe Kapitel 10.5.4

10.5.2 Betriebsdaten / Betriebsstunden


Hier werden die Laufzeit der Pumpe (entspricht Anzahl der Hbe 480 ms) seit
Erstinbetriebnahme bzw. seit der letzten Rcksetzung angezeigt.

10.5.2.1 Auswhlen / Anzeigen / Lschen


Abb. 10.63

10.5.3 Betriebsdaten / Liter


Hier wird die dosierte Menge in Liter seit Erstinbetriebnahme bzw. seit der letzten
Rcksetzung angezeigt. Bei Betrieb der Pumpe ohne Ovalradzhler wird dieser Wert
errechnet (ml / Hub Anzahl der dosierten Hbe). Mit Anschluss eines Ovalradzhlers wird
die gemessene Menge angezeigt (ermittelt aus der Anzahl der Ovalradzhler-Impulse).

417101442_KKS_E60.docx - 53 - Rev. 10-06.11


10.5.3.1 Auswhlen / Anzeigen / Lschen
Abb. 10.64

10.5.4 Betriebsdaten / Impulsanzahl


Hier wird die ber den Impulseingang der Pumpe (Stecker II Pin 3+4, siehe Kapitel 7.2.3
Anschlussbelegung Stecker II) eingegangene Anzahl an Impulsen seit Erstinbetriebnahme
bzw. seit der letzten Rcksetzung angezeigt.

10.5.4.1 Auswhlen / Anzeigen / Lschen


Abb. 10.65

417101442_KKS_E60.docx - 54 - Rev. 10-06.11


11 Wartung
VORSICHT Dosierpumpen drfen nur von sachkundigen und autorisierten Personen gewartet werden.

Wartungsintervall 1/2 jhrlich, krzere Intervalle bei starker Beanspruchung


HINWEIS (z. B. Dauerlauf).

Empfohlen wird die Kontrolle:


von Saug- und Druckleitung auf Leckage-freien Anschluss
von Saug- und Druckventil (Kapitel 11.1, Abb. 11.1) auf Verschmutzung und Dichtigkeit.
des Ablaufanschluss (Kapitel 5, Abb. 5.1) am Pumpenkopf (Membranbruch)
der korrekten Dosierung
berwurfmuttern (Kapitel 7.1.2, Abb. 7.6 und Kapitel 7.1.3, Abb. 7.7)
der Dosierkopfschrauben (Kapitel 11.2, Abb. 11.3, Pos. 2) (fester Sitz, 3 - 4 Nm)
Die Lebensdauer der Membrane ist abhngig von:
Gegendruck, Betriebstemperatur und Dosiermedium.
HINWEIS Es wird empfohlen, die Membrane bei extremen Betriebsbedingungen und Dosierung von
abrasiven Stoffen fters zu kontrollieren.

11.1 Austausch von Saug- / Rcklauf- und Druckventil


Abb. 11.1
Pos. Bezeichnung
ANSCHLUSSSET
1 berwurfmutter
A 2 Spannteil
3 Kegelteil
SAUG-/RCKLAUFVENTIL
4 O-Ring, 10 x 2,5
B 5 Saug-/Druckventil
6 O-Ring, 14 x 2,5
C WINKELANSCHLUSS
DRUCKVENTIL
4 O-Ring, 10 x 2,5
6 O-Ring, 14 x 2,5
D Druckventil (Dosierleitung)
I Ventilfeder
7
II Ventilkugel
III O-Ring, 12 x 1,5

Saug-, Rcklauf- und Druckventil (Pos. 5 bzw. 7) mit Gabelschlssel (SW 22)
demontieren.
Am Druckventil (Pos. 7) ist darauf zu achten, dass Ventilfeder (Pos. I), Ventilkugel (Pos. II)
HINWEIS und O-Ring (Pos. III) nicht verloren gehen und beim Widereinbau lagerichtig montiert
werden.

Alle O-Ringe montieren.


Neues Saug-, Rcklauf- und Druckventil lagerichtig einschrauben
(Anzugsdrehmoment 2-3 Nm)

417101442_KKS_E60.docx - 55 - Rev. 10-06.11


11.1.1 Saug- und Rcklaufventile lagerichtig einbauen
Abb. 11.2

Auf den Saug-/Rcklaufventilen ist die Flierichtung mittels


eines eingeprgten Pfeils markiert.
Beim Einbau ist unbedingt darauf zu achten, dass die
Ventile der Flierichtung entsprechend eingebaut werden!

11.2 Austausch der Membrane und des Pumpenkopfes


Abb. 11.3 Pos. Beschreibung
1 Pumpenkopf
2 Dosierkopfschrauben
3 Keramikkolben
4 Membraneinheit
5 Faltenbalg
6 Zwischenplatte

Vor dem ffnen des Pumpenkopfes:


ACHTUNG Anschlussleitungen entleeren,
Pumpenkopf splen.
Dosierkopfschrauben (Pos. 2) lsen
Pumpenkopf (Pos. 1) absolut gerade abziehen.
Den Keramikzylinder gerade abziehen, da er ansonsten beim Verkanten zerstrt werden
ACHTUNG kann!
Den Keramikkolben (Pos. 3) seitlich aus der Kupplung der Membraneinheit (Pos. 4)
herausnehmen
Membraneinheit (Pos. 4) herausschrauben.
Zwischenplatte (Pos. 6) abnehmen
Faltenbalg (Pos. 5) austauschen.
Die Membraneinheit (Pos. 4) beim Anziehen nicht berziehen,
bis zum Anschlag leicht festschrauben.
Der Leckageanschluss der Zwischenplatte (Pos. 6) muss nach unten zeigen.
Den Keramikkolben (Pos. 3) wieder einsetzen
Den Zylinder im Pumpenkopf vorsichtig aufstecken.
Pumpenkopfschrauben handfest eindrehen
Pumpenkopfschrauben ber Kreuz anziehen
HINWEIS Anzugsmoment der Dosierkopfschrauben = 3 - 4 Nm.
Dosierkopfschrauben-Anzugsmoment nach 24 Stunden berprfen!
ACHTUNG Pumpenkopf absolut gerade ansetzen. Der Dosierkopf ist gleichmig diagonal
anzuziehen.

417101442_KKS_E60.docx - 56 - Rev. 10-06.11


11.3 Austausch der Zylinderkolbeneinheit
Verfahren wie unter Kapitel 11.2 beschrieben.
Abb. 11.4 Pos. Beschreibung
1 Zylinderkolbeneinheit
2 O-Ring, 22 x 2 (FPM)
3 O-Ring, 22 x 2 (EPDM)
4 Feder
5 O-Ring, 14 x 2,5
6 Ventilnippel
7 Scheibe
8 Ventilkugel
9 O-Ring, 12 x 1,5
Ventilnippel (Pos. 6)
herausschrauben.
Scheibe (Pos. 7), Ventilkugel
(Pos. 8) und Feder (Pos. 4)
entfernen.
Zylinderkolbeneinheit (Pos.
1) in Richtung Membransitz
herausdrehen.
Neue Einheit einsetzen. O-Ringe (Pos. 2, 3, 5, 9) tauschen.
Ventilnippel (Pos. 6), Ventilkugel (Pos. 8) usw. wieder einbauen.
ACHTUNG Der Zylinder kann nur in Verbindung mit dem Keramikkolben ausgetauscht werden.

11.4 Justierung der mechanischen Hubverstellung


Abb. 11.5 Abb. 11.6 Pos. Bezeichnung
1 Hubverstellknopf
2 Madenschrauben (2 x gegenberliegend)
3 Verstellknopfmarkierungen
4 Aufnahme fr den Verstellknopf (verzahnt)
5 Noniusskala
6 Dosieranschluss
Die Dosierpumpe wird im Werk bei Nenndruck
entsprechend den Dosierkurven eingestellt.
Sollte die Hubeinstellung durch Abziehen des
Verstellknopfes verstellt sein, kann die
Grundeinstellung wie folgt ermittelt werden:
Dosierpumpe einschalten.
Die 2 gegenberliegenden
Madenschrauben (Pos. 2) lockern.
Der Hubverstellknopf (Pos. 1) kann nun
von der darunter liegenden Verzahnung
(Pos. 4) abgezogen werden.
Die Aufnahme fr den Verstellknopf (Pos. 4) langsam nach links (gegen den Uhrzeigersinn)
drehen, bis kein Medium mehr aus dem Dosieranschluss (Pos. 6) fliet.
Den Hubverstellknopf (Pos. 1) mit der Markierung 0 (Pos. 3) nach oben, deckungsgleich auf den
Markierungsstrich der Noniusskala (Pos. 5) aufschieben. Der Verstellknopf wird soweit auf die
Verzahnung aufgeschoben, bis die Auenkante die Markierung -0 (Pos. 5) der Noniusskala
erreicht hat.
Abschlieend die Madenschrauben (Pos. 2) wieder anziehen.
Die Hubverstellung ist nun auf werkseitige Einstellung justiert.
HINWEIS Fr die genaue Ermittlung der Dosierleistung sollte die Pumpe ausgelitert werden.

417101442_KKS_E60.docx - 57 - Rev. 10-06.11


12 Betriebsstrungen
12.1 Warnmeldungen Dosierung (Display)
Wenn keine externen Signale mehr verarbeitet werden und die Ausgangssignale
(Leer, Strung) abgeschaltet sind, knnen folgende Fehlermeldungen auf dem Display der
Dosierpumpe angezeigt werden:
Display Bedeutung Auswirkung Ursache Behebung
Abb. 12.1

Reservemeldung
Pumpe luft weiter Niveauvorwarnung aktiv Dosiermedium bevorraten
(blinkend)

Abb. 12.2
Pumpe wird Dosiermedium ersetzen,
Leermeldung Leermeldung aktiv
gestoppt wechseln

Externe Freigabe
Dosiersperre
Abb. 12.3 aktivieren oder im
(nur mglich wenn Pumpe wird kein externe Freigabe der
Konfigurationsmen die
diese konfiguriert gestoppt Pumpe
Dosiersperre inaktiv setzen.
wurde.)
(siehe Kapitel 10.3.7)
Anzeige im
Betriebsmodus Normsignal liegt unter
Abb. 12.4
4..20 mA blinkt Pumpe wird 3 mA oder Kabel zum Normsignal bzw. Kabel
gestoppt Normsignalanschluss ist berprfen
Normsignalber- gebrochen
wachung spricht an
Abb. 12.5 Normsignal liegt Pumpe luft im Normsignal berschreitet
Normsignal verringern
--.- ber 23;0 mA Dauerlauf Anzeigeumfang

12.2 Strmeldungen (Display)


Display Bedeutung Auswirkung Ursache Behebung
Abb. 12.6
Motor luft
Leistungselektronik
unkontrolliert im berdosierung Platine austauschen
defekt
Dauerlauf.

Abb. 12.7 Gegendruck zu hoch Druck verringern


Motor steht trotz Ventil auf Druckseite
geschlossen Ventil ffnen
drehendem Keine Dosierung
Dosiersymbol Motor berhitzt/defekt Motor abkhlen lassen,
Leistungselektronik bzw. austauschen
defekt Platine austauschen
Abb. 12.8 Steckverbindung von
Getriebe zur Platine
Motor in Optischen Sensor
unterbrochen,
Dauerlauf ohne Dauerdosierung Anschluss berprfen
Platine defekt
Anforderung Pumpe einschicken
Optischer Sensor
verschmutzt
Abb. 12.9 Strung in der Schlauch defekt Schluche kontrollieren
Auswertung der Membrane defekt Membrane kontrollieren
Dosierber- Pumpe dosiert zu
wachung oder wenig oder zu viel. Gegendruck zu hoch
des Gegendruck kontrollieren.
oder zu niedrig
Ovalradzhlers

417101442_KKS_E60.docx - 58 - Rev. 10-06.11


12.2.1 Strungstabelle

Strung mgliche Ursache Behebung


Dosierpumpe arbeitet nicht, Netzkabel beschdigt Netzkabel wechseln
keine Displayanzeige Falsche Spannung Netzspannung berprfen
ber Saugleitung den Dosierkopf
Pumpe saugt trotz Entlftung Ablagerungen, Verkleben,
durchsplen, evtl. Ventile ausbauen und
und max. Hub nicht an Austrocknen der Ventile
reinigen bzw. austauschen
Dosierkopf ist undicht, Medium Dosierkopfbefestigungsschraube
Dosierkopf ist locker
tritt aus dem diagonal anziehen
Membranbruchablauf
Membrane gerissen Membrane austauschen
(Leckageanschluss)
Schwimmer der Sauglanze ist
Schwimmer gangbar machen
blockiert
Sauglanzenstecker oder Stecker festziehen, Kontakte reinigen,
Niveauanzeige erscheint im Brckenstecker ist locker bzw. berprfen ob Brckenstecker gesteckt
Display trotz vollem Behlter nicht angesteckt. ist
Sauglanzenkabel defekt Leermeldeeinrichtung austauschen

Vor Reparatur- und Wartungsarbeiten und Dosierung von gefhrlichen Medien immer den
VORSICHT Dosierkopf splen, die Druckleitung entlasten und Schutzkleidung (Schutzbrille,
Schutzhandschuhe und Schrze) tragen.

Elektroreparaturen drfen nur durch Elektrofachkrfte ausgefhrt werden (Sicherheitsregeln der


Berufsgenossenschaft VB G 4 und ZH 1/11)!
Beim ffnen von Abdeckungen oder Entfernen von Teilen, auer wenn dies ohne
VORSICHT Werkzeug mglich ist, knnen Spannungsfhrende Teile freigelegt werden. Auch knnen
Anschlussstellen spannungsfhrend sein.

Vor einem Abgleich, einer Wartung, einer Instandsetzung oder einem Austausch von Teilen
muss das Gert von allen Spannungsquellen getrennt sein, wenn ein ffnen des Gertes
erforderlich ist.

417101442_KKS_E60.docx - 59 - Rev. 10-06.11


13 Verschlei- und Ersatzteile (Standard-Ausfhrung)
13.1 Explosionszeichnung
Abb. 13.1

Pos Beschreibung Typ 00002 Typ 00005 Typ 00009 Typ 00014
Anschlussset gewinkelt PVDF G 3/8i - Schlauch 2/4 mm (ID/AD) 247613 --
1
Anschlussset gewinkelt PVDF G 3/8"i - Schlauch 4/6 mm (ID/AD) -- 247620
2 Vierkantmutter 413226005
3 Madenschraube 413401178
4 Hubverstellknopf 34070193
Druckventil PVDF/FPM (Viton B), DRV PVFPKE004
247623 --
G3/8-G3/8-99 00002
Druckventil PVDF/FPM (Viton B), DRV PVFPKE008
-- 247624 --
G3/8-G3/8-99 00005/00009
Druckventil PVDF/FPM (Viton B) DRV PVFPKE008
5 -- 247630
G3/8-G3/8-99 00014
Druckventil PVDF/EPDM DRV PVEPKE004 G3/8-G3/8-99 00002 247631 --
Druckventil PVDF/EPDM DRV PVEPKE008
-- 247632 --
G3/8-G3/8-99 00005/00009
Druckventil PVDF/EPDM DRV PVEPKE008 G3/8-G3/8-99 00014 -- 247633
6 Scheibe 34070186
7 Verstellmutter 34070185
8 Zylinderkolbeneinheit komplett 247607 247609 247605 247604
Saug-/Rcklaufventil, PVDF/FPM (Viton B)
248405
9 SDVPVFPKE000 G3/8-G3/8-99
Saug-/Rcklaufventil, PVDF/EPDM SDVPVEPKE000 G3/8-G3/8-99 248406
Anschlussset 3/8 PVDF fr Schlauch 6/8, 6/10, 6/12 mm (ID/AD) 247629
10
Anschlussset 3/8" PVDF fr Duo-Schlauch 6/10 mm (ID/AD) 247610
11 Pumpenkopf, PVDF 34070192
12 Kupplung Membraneinheit komplett 247601 247608 247602 247601
13 Zwischenplatte 34070173
14 Schutzmembran (Austausch nur in Verbindung mit Pos. 12) 34760112
15 Blindstecker fr Leer-, Vormeldung 248186
16 Blindstecker fr Impulseingang 248187
17 Abdeckkappe 34800117
18 Stecker 4-polig (3-polig) Leermelde-/Impulseingang 418463115
19 Stecker 5-polig Strom-/Impulseingang 418463118
20 Stecker 4-polig Leermelde-/Impulseingang 418463117
21 Klarsichtdeckel 34800120
22 Netzkabel EMP KKS/II E60 Schuko 2m 34860001

417101442_KKS_E60.docx - 60 - Rev. 10-06.11


13.2 Verschleiteilset
bestehend aus je 1 Stck:
- Saugventil, Vorfrderung (Pos. 9)
- Druckventil, Rcklauf (Pos. 9)
- Druckventil, Druckseite (Pos. 5)
- Anschlussset fr Schlauch 4/6, 6/8, 6/12 mm (ID/AD) (Pos. 10)
- Membraneinheit (Pos. 12)
- Zwischenplatte (Pos. 13)
- Schutzmembran (Pos. 14)
Beschreibung (Verschleiteilset EMP KKS) Artikel Nr.
00002 PVFPKE 247676
00005 PVFPKE 247677
00009 PVFPKE 247678
00014 PVFPKE 247679
00002 PVEPKE 247686
00005 PVEPKE 247687
00009 PVEPKE 247688
00014 PVEPKE 247689

1. Pumpentyp (Pumpenleistung)
00002 = 0,2 l/h
00005 = 0,5 l/h
00009 = 0,9 l/h
00014 = 1,4 l/h
2. Werkstoff Ventil
PV = PVDF
3. Werkstoff Dichtung
FP = Viton B
EP = EPDM
4. Werkstoff Kugel
KE = Keramik
Verschleiteilset EMP KKS 00014 PV FP KE

417101442_KKS_E60.docx - 61 - Rev. 10-06.11


14 Technische Daten
14.1 Pumpenschlssel
1. Elektrische Version
...
E 60 = (Erklrung siehe Kapitel 14.1.1)
...
2. Pumpenleistung 50 Hz (60 Hz)
00002 = 0,2 l/h (0,24 l/h)
00005 = 0,5 l/h (0,6 l/h)
00009 = 0,9 l/h (1,1 l/h)
00014 = 1,4 l/h (1,7 l/h)
3. Pumpenkopfwerkstoff
PV = PVDF (Standard)
4. Dosiergegendruck (nicht frei whlbar)
10 = 10 bar (8 bar)
5. Werkstoff Dichtung
FP = Viton B (Standard)
EP = EPDM
KA = Kalrez
6. Werkstoff Kugel
KE = Keramik (Standard)
GL = Glas
7. Werkstoff Ventil
PV = PVDF (Standard)
8. Ventilfeder
99 = ohne Feder
9. Netzanschluss
17 = Netzkabel 2m Gerte- und
Schukostecker (E60, 230 V) (Standard)
21 = Netzkabel 2 m Gertestecker und
Aderendhlsen (E60, 115 V)
10. Spannung/Frequenz
01 = 115V / 50 Hz
02 = 115V / 60 Hz
E60 00009 PV 10 FP KE PV 99 17 03 03 = 230V / 50 Hz (Standard)
04 = 230V / 60 Hz

Andere Spezifikationen auf Anfrage!

417101442_KKS_E60.docx - 62 - Rev. 10-06.11


Pumpenschlssel 2

11. Anschluss Vorfrderung


04 = Set fr PE-Schlauch 6/8
05 = Set fr PVC- Schlauch 6/10
06 = Set fr PVC-Gewebeschlauch 6/12
33 = Set fr Schlauch 6/8, 6/10, 6/12 (Standard)
12.Anschluss Druckseite
31 = Set gewinkelt fr PE/PTFE Schlauch 2/4
(Standard bei 0,2 l/h)
32 = Set gewinkelt fr PE/PTFE Schlauch 4/6
(Standard bei 0,5 - 1,4 l/h)
34 = Set gewinkelt fr Schlauch 2/4, 4/6
13. Werkstoff Anschluss
99 = PVDF
14.Elektrische Hubverstellung
99 = ohne elektrische Hubverstellung
15. Membranbrucherkennung
99 = ohne Membranbrucherkennung
16. Gehuseversion
01 = Standardgehuse

33 32 99 99 99 01 Andere Spezifikationen auf Anfrage!

Beispiel fr den kompletten Pumpenschlssel einer Standardpumpe:


E60 00009 PV 10 FP KE PV 99 17 03 - 33 32 99 99 99 01
(Pumpenschlssel 1) (Pumpenschlssel 2)

417101442_KKS_E60.docx - 63 - Rev. 10-06.11


14.1.1 Pumpenschlsseldefinition E60
Elektrische Version
E 60 Start/Stop Taster zum Ein- Ausschalten der Pumpe
mechanische Hubverstellung
hinterleuchtetes Graphikdisplay, 4 Bedientasten
Einzelhubsteuerung (jeder Hub wird vollstndig ausgefhrt)
Dosierkontrolle ber Hubsignalausgang (rechnerisch)
oder ber externes Dosierberwachungssystem
Erfassung von Betriebs- und Verbrauchsdaten (rechnerisch)
Kalibrierfunktion
einstellbare Betriebsarten:
Internbetrieb
Einstellung von Dosiermenge/Dosierfrequenz in:
Hbe/min
Prozent
Liter/h (bzw. Gallone/h)
Externbetrieb
Impulsbetrieb (Ansteuerung ber Impulse)
- Impulsmultiplikation (1 eingehender Impuls = n Dosierhbe)
- Impulsdivision (n eingehende Impulse = 1 Dosierhub)
Normsignalbetrieb (Ansteuerung ber externes Normsignal 0/4 - 20 mA bzw. 20 - 0/4 mA)
Chargenbetrieb (ausgelst durch einen externen Freigabeimpuls wird eine vorher
eingestellte Menge dosiert)
Eingnge:
Niveauberwachung Gebindebehlter (Niveauvorwarnung und Leermeldung)
Impuls
Normsignal
Freigabe (Dosiersperre)
Dosierberwachung
Ausgnge:
Niveauberwachung Gebindebehlter (Niveauvorwarnung und Leermeldung)
Strungsmeldung
Hubsignal
wie E 60, jedoch zustzlich mit Dongle-Box zum Anschluss eines Ovalradzhlers OGM
PLUS
E 60PLUS
(Erweiterungseinheit fr Betriebsdatenerfassung)
Anzeige der tatschlich gemessenen Dosiermenge und automatische Nachregelung der
Pumpenleistung (nur in Verbindung mit externem Durchflussberwachungssystem
Ovalradzhler OGMPLUS)
Automatische Kalibrierfunktion ber Ovalradzhler
Verbrauchsdatenkontrolle mittels Ovalradzhler

417101442_KKS_E60.docx - 64 - Rev. 10-06.11


14.2 Abmessungen
Abb. 14.1

417101442_KKS_E60.docx - 65 - Rev. 10-06.11


14.3 Technische Daten bersichtstabellen
14.3.1 Elektrische Daten
Pumpentyp
Bezeichnung
00002 00005 00009 00014
Versorgungsspannung 230 V / 50/60 Hz 10 %
(Sonderspannungen auf Anfrage)
max. Stromaufnahme IN 115 V 50/60 Hz 0,2 / 0,21 A
230 V 50/60 Hz 0,09 A
Motorleistung 115 V 50/60 Hz
18,7 / 19,8 W
230 V 50/60 Hz
Sicherungswert 315 mA
Schutzart IP 65
Schaltleistung bei Beschaltung mit 24 V
Leermeldeausgang 24 V 3 A AC/DC
Hubsignalausgang 24 V 0,3 A DC
Schaltleistung bei Beschaltung mit 230 V
Leermeldeausgang 230 V / 3 A AC/DC
Hubsignalausgang Anschluss nach VDE nicht zulssig

14.3.2 Allgemeine Daten


Pumpentyp
Bezeichnung
00002 00005 00009 00014
Pumpenleistung [l/h]*/** 0,2 0,5 0,9 1,4
max. Dosiergegendruck [bar] 10
Kolbendurchmesser [mm] 3 4,76 6,34 8
Hubzahl [1/min] bei 50 Hz 122
Dosiermenge/Hub [cm] 50 Hz/60 Hz 0,027 / 0,032 0,068 / 0,082 0,12 / 0,44 0,19 / 0,23
Reproduziergenauigkeit [s. Kapitel 14.6] < 3%
max. frderbare Viskositt [mPas] 200
Zulssige Umgebungstemperatur 5-40C
Saughhe [mWS] bei 100%
2
Hubeinstellung***
max. Vordruck saugseitig [bar] 0,3
Geruschpegel (DBA) in 1 m Abstand
54,0
(nach DIN EN 12639/ EN ISO 9614-2)
Schlauchanschlsse
6/8, 6/10, 6/12
Saug-/Rcklaufleitung [ID mm]
Schlauchanschlsse
2/4 4/6
Druck(Dosier)leitung [ID mm]
Gewicht [kg] 2,4
* Werte ermittelt mit Dosiermedium Wasser mit einer Temperatur von 20C.
** Bei Netzfrequenz 60 Hz erhht sich die Frderleistung um 20 %, der Dosiergegendruck vermindert sich um 20 %.
*** Ansaughhen ermittelt mit sauberen, angefeuchteten Ventilen bei 100% Dosierhub und max. Hubfrequenz

417101442_KKS_E60.docx - 66 - Rev. 10-06.11


14.3.3 Ein- / Ausgangsbeschaltung
14.3.3.1 Steckplatz I

Abb. 14.2 Eingnge Belegung Externe Werte


Beschaltung
1 (braun)
Niveauvorwarnung + potentialfreier Kontakt
4 (schwarz) Achtung: Keine
3 (blau) externe Spannung
Leermeldung + anschlieen!
4 (schwarz)

14.3.3.2 Steckplatz II

Abb. 14.3 Eingnge Belegung Externe Werte


Beschaltung
2 (wei)
Impuls + potentialfreier Kontakt min. Ein- / Ausschaltdauer = 15 ms
4 (schwarz) Achtung: Keine
5 (grau) externe Spannung
Dosiersperre, Charge,
+ anschlieen!
Dosierberwachung
4 (schwarz)
Externer Strom
3 (blau) Achtung:
Normsignal + Polaritt von 0/4-20 mA, Brde ca. 50 Ohm
4 (schwarz) angeschlossenem
Signal beachten!
Ausgnge Belegung Externe Werte
Beschaltung
potentialfreier Kontakt
1 (braun)
externe Achtung: Keine Versorgung fr externe Gerte:
+
Versorgung externe Spannung Ausgang 5V, DC, max. 50 mA
4 (schwarz)
anschlieen!

14.3.3.3 Steckplatz III

Abb. 14.4 Ausgnge Belegung Externe Werte


Beschaltung
max. externe Spannung 230 VAC/DC
Niveauvorwarnung, 1 (braun) max. 3 A
Niveau- + bei Niveauvorwarnung:
Leermeldung, Externe Spannung
2 (wei) Kontakt ca. 500 ms geschlossen
Strmeldung
Kontakt ca. 500 ms offen
Max. externe Spannung 24 V DC, max. 0,3 A
Bei Stillstand: Kontakt offen
bei 50 Hz Netz:
bei 100 % Lauf:
Kontakt ca. 310 ms geschlossen
Kontakt ca. 180 ms geffnet
Externe Spannung
bei 50 % Lauf:
3 (blau) Kontakt ca. 310 ms geschlossen
Achtung:
Hubsignal + Kontakt ca. 660 ms geffnet
Polaritt von
4 (schwarz)
angeschlossenem bei 60 Hz Netz:
Signal beachten!
bei 100 % Lauf:
Kontakt ca. 260 ms geschlossen
Kontakt ca. 150 ms geffnet
bei 50 % Lauf:
Kontakt ca. 260 ms geschlossen
Kontakt ca. 550 ms geffnet

417101442_KKS_E60.docx - 67 - Rev. 10-06.11


14.4 Werkstoffe
Pumpenkopf: PVDF
Dosierkolben/-Zylinder: Keramik
Membrane: PTFE-EPDM - Verbundmembrane
Dichtungen: FPM (Viton B), wahlweise EPDM
Ventile: PVDF
Ventilkugeln: Keramik
O-Ring: FPM, wahlweise EPDM
Ventilfedern: Hastelloy C4/C22 PTFE - beschichtet
Gehuse: Thermoplastischer Polyester
Farbe: Blau RAL 5007
Sonderausfhrungen auf Anfrage.

14.5 Anschlussstecker / Steuer Ein- und Ausgnge


14.5.1 Pinbelegung / Aderfarben Stecker I (3-polig)
Anschluss Niveauvorwarnung bzw. Leermeldung
Abb. 14.5 Aderfarbe
Pos (Anschlusskabel)
Bezeichnung
1 braun Niveauvorwarnung
3 blau Niveau- Leermeldung
4 schwarz GND
siehe auch Kapitel: 7.2.2
Falls die Leermeldung nicht benutzt wird, muss Kontakt 3/4 immer gebrckt werden! Die
ACHTUNG hierfr vorgesehene Schutzkappe (siehe Kapitel 7.2.1) stellt die Brcke zwischen den
Kontakten her und muss in diesem Fall aufgesteckt sein.

HINWEIS
Der Leer- und Reservemeldeeingang kann im Men Konfiguration / Niveaukontakt
invertiert werden. (siehe Kapitel 10.3.8)

14.5.2 Pinbelegung / Aderfarben Stecker II (5-polig)


Anschluss Impuls- / Normsignaleingang und Dosiersperre
Abb. 14.6 Aderfarbe
Pos (Anschlusskabel)
Bezeichnung
1 braun Ausgang 5 V, DC
2 wei Impulseingang
3 blau Eingang Dosiersperre
4 schwarz GND
5 grau Eingang Normsignal 0/4 20 mA
siehe auch Kapitel 7.2.3
Der Dosiersperreneingang ist nur aktiv, wenn er zuvor im Men Konfiguration /
HINWEIS Dosiersperre eingestellt wurde (siehe Kapitel 10.3.7). Die Funktion Charge (siehe Kapitel
10.3.15) und Dosierberwachung (siehe Kapitel 10.3.13) muss ebenfalls konfiguriert werden

14.5.3 Pinbelegung / Aderfarben Stecker III (4-polig)


Anschluss Leermelde-, Strmelde-, Hubsignalausgang:
Abb. 14.7 Aderfarbe
Pos (Anschlusskabel)
Bezeichnung
Ausgang Niveauvorwarnung, Niveau- Leermeldung,
1 braun
Strung (+)
Ausgang Niveauvorwarnung, Niveau- Leermeldung,
2 wei
Strung (-)
3 blau Ausgang Hubsignal (+)
4 schwarz Ausgang Hubsignal (-)
siehe auch Kapitel 7.2.4
Bei Anschluss von 115V/230 V an Kontakt 1+2 (Alarmausgang) ist ein gleichzeitiges Nutzen
ACHTUNG von Kontakt 3+4 (Hubsignalausgang) generell nicht erlaubt

417101442_KKS_E60.docx - 68 - Rev. 10-06.11


14.6 Dosierleistungen
Die reproduzierbare Dosiergenauigkeit betrgt ca. 3 % bei minimal 30 % Hublnge und
gleich bleibenden Verhltnissen. Die Einstellung der Hublnge muss hierbei wegen dem
Spielausgleich immer ausgehend vom niedrigeren Wert zur gewnschten Hublnge erfolgen
(= Drehrichtung rechts).
Durch die Charakteristik der Pumpe kann es bis zum Erreichen der Betriebstemperatur zu
hheren Leistungen kommen.
Unter Beachtung folgender Punkte kann eine genaue Dosierung erreicht werden:
a) Alle Dosierleistungsangaben sind bezogen auf Messungen mit Wasser bei 20 C,
konstanter Versorgungsspannung und betriebswarmen Zustand der Dosierpumpe. Die
Werkseinstellung der Dosiermenge (= Einstellgenauigkeit) bei max. Dosiergegendruck
betrgt + 5 - 15 % vom Nennwert.
b) Um eine hohe Dosiergenauigkeit bei Dosierung im freien Auslauf zu erhalten, soll ein
Druckhalteventil (oder Dosierventil) zur Erzeugung eines mglichst gleich bleibenden
Gegendruckes von mindestens 0,5 bar verwendet werden.
c) Liegt auf der Saugseite ein Vordruck an, muss der Differenzdruck zwischen Saug- und
Druckseite mindestens 1 bar betragen. Die anstehende Wassersule auf die
Dosierpumpe muss durch eine entsprechende Ventilanordnung abgesichert werden.
HINWEIS Ein Druckhalteventil oder ein Dosierventil ist kein absolut schlieendes Absperrorgan.
Dosierhubverstellung nur bei laufender Pumpe, wenn die Hubeinstellschraube entlastet
ACHTUNG ist.

14.7 Frderleistung in Abhngigkeit von Gegendruck


Einstellgenauigkeit + 15 % - 5 % vom Nennwert, smtliche Angaben bezogen auf Wasser bei
20 C und gem der Hinweise in der Bedienungsanleitungen.
HINWEIS Die Leistungskurven sind bei einer Pumpenfrequenz von 50 Hz dargestellt.
Abb. 14.8
1.6

1.5

1.4

1.3

1.2

1.1
Frderleistung (l/h)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0
1 2 3 4 5 6 7 8 9 10

Dosiergegendruck (bar)

417101442_KKS_E60.docx - 69 - Rev. 10-06.11


14.8 Frderleistung in Abhngigkeit von der Hublnge
Einstellgenauigkeit + 15 % - 5 % vom Nennwert, smtliche Angaben bezogen auf Wasser bei
20 C und gem der Hinweise in der Bedienungsanleitungen.
HINWEIS Die Leistungskurven sind bei einer Pumpenfrequenz von 50 Hz dargestellt.
Abb. 14.9
1.6

1.5

1.4

1.3

1.2
2 bar2 bar
Typ 014
Typ 014
1.1
Frderleistung (l/h)

0.9 10 bar
10 bar Typ 014
Typ 014

0.8

0.7 2 bar2 bar


Typ 009
Typ 009

0.6
1010 bar
bar TypTyp
009 009
0.5

0.4 2 bar2 bar


TypTyp 005
005

0.3 1010 bar


bar TypTyp
005 005
0.2 2 2 bar Typ
bar Typ 002002

0.1
10 bar
10 bar TypTyp
002 002
0
0 10 20 30 40 50 60 70 80 90 100

Hublnge (%)

417101442_KKS_E60.docx - 70 - Rev. 10-06.11


15 Konformittserklrung

417101442_KKS_E60.docx - 71 - Rev. 10-06.11


Contents

1 General ............................................................................................................................................... 75
1.1 Warranty coverage...............................................................................................................................................................75
1.2 Contact address / Manufacturer .........................................................................................................................................75
2 Safety .................................................................................................................................................. 76
2.1 Safety Notes .........................................................................................................................................................................76
2.2 Emphases .............................................................................................................................................................................76
2.3 Numberings ...........................................................................................................................................................................76
2.4 Special safety Notes for maintenance and repair work ..................................................................................................76
3 Delivery scope ................................................................................................................................. 77
PLUS
3.1 Upgrade accessories for the EMP KKS E60 .............................................................................................................77
4 Functional description ................................................................................................................... 78
4.1 Mechanical functions ...........................................................................................................................................................78
4.2 Electronic functions ..............................................................................................................................................................78
4.2.1 Operation modes .....................................................................................................................................................................78
PLUS
4.3 Additional electronic functions on the EMP KKS E60 ..............................................................................................78
5 Setup ................................................................................................................................................... 79
5.1 EMP KKS E60 ......................................................................................................................................................................79
PLUS
5.2 EMP KKS E60 ...............................................................................................................................................................79
5.3 Indicators / Controls / Jacks................................................................................................................................................79
5.3.1 EMP KKS E60 and EMP KKS E60PLUS versions .......................................................................................................................79
5.3.2 Dongle box ports ...................................................................................................................................................................79
6 Mounting ............................................................................................................................................ 80
6.1 Mounting diagram ................................................................................................................................................................80
7 Device installation .......................................................................................................................... 81
7.1 Hydraulic installation ............................................................................................................................................................81
7.1.1 Installation examples ...............................................................................................................................................................81
7.1.2 Connecting the suction line and return line ..............................................................................................................................82
7.1.3 Connection of pressure line .....................................................................................................................................................83
7.2 Electrical installation ............................................................................................................................................................83
7.2.1 Inputs and outputs ...................................................................................................................................................................83
7.2.2 Connector assignments of Slot I (3-terminal) input for low-level advance warning and empty report ........................................84
7.2.2.1 Installing suction pipe with low-level advance warning and empty report ................................................................................................................. 84
7.2.3 Connector assignment of slot II (5-terminal) input for pulse signal, standard signal, metering lock, batch and metering
monitoring................................................................................................................................................................................85
7.2.3.1 Installing the pulse control (water meter) ................................................................................................................................................................... 85
7.2.3.2 Installing the standard signal control .......................................................................................................................................................................... 85
7.2.3.3 Installing the control via the metering lock ................................................................................................................................................................. 86
7.2.3.4 Installing the batch function ........................................................................................................................................................................................ 86
7.2.3.5 Installing the metering monitoring .............................................................................................................................................................................. 87
7.2.4 Connector assignments of slot III (4-terminal) output for alarm and stroke signal .....................................................................88
7.2.4.1 Installing the alarm or fault report output at 24 V ....................................................................................................................................................... 88
7.2.4.2 Installing the stroke signal output at 24 V / DC .......................................................................................................................................................... 88
7.2.4.3 Hardware migration for alarm contact ........................................................................................................................................................................ 89
7.2.4.3.1 In the alarm output "ON" configuration setting 89
7.2.4.3.2 In the alarm output OFF configuration setting 89
7.2.5 Connector assignments of slot IV, mains power supply............................................................................................................89
PLUS
8 Upgrading the EMP KKS E60 to the EMP KKS E60 ......................................................... 90
8.1 Fitting the dongle box ..........................................................................................................................................................90
8.2 Connector assignments of the slots ..................................................................................................................................91
8.2.1 Connector assignments of slot V (5-terminal), input for oval gear meter...................................................................................91
8.2.1.1 Installing the oval gear meter (OGM or OGMPLUS) ..................................................................................................................................................... 91
8.2.2 Connector assignments of Slot VII (5-terminal) input for batch pulse and metering lock ...........................................................92
8.2.2.1 Installing the batch pulse ............................................................................................................................................................................................ 92
8.2.2.2 Installing the metering lock (optional connector VII or VIII) ....................................................................................................................................... 93
8.2.3 Connector assignments of Slot VIII (5-terminal) input for pulse, standard signal input and metering lock .................................93
8.2.3.1 Installing the pulse control (water meter) ................................................................................................................................................................... 93
8.2.3.2 Installing the standard signal (mA) ............................................................................................................................................................................. 94
8.2.3.3 Installing the metering lock ......................................................................................................................................................................................... 94
9 Startup ................................................................................................................................................ 95
9.1 Switching on the pump ........................................................................................................................................................95
9.2 Switching off the pump ........................................................................................................................................................95
9.3 Key functions ........................................................................................................................................................................95
9.4 Description of display symbols ...........................................................................................................................................95
9.5 Initial startup / Delivery status ............................................................................................................................................96
9.5.1 Software version display ..........................................................................................................................................................96
9.5.2 Display at operating display .....................................................................................................................................................96
9.5.3 Configuration ...........................................................................................................................................................................96

417101442_KKS_E60.docx - 72 - Rev. 10-06.11


10 Menu description ............................................................................................................................. 97
10.1 Main menu ............................................................................................................................................................................97
10.1.1 Overview .................................................................................................................................................................................97
10.2 Operation mode ....................................................................................................................................................................98
10.2.1 Selecting..................................................................................................................................................................................98
10.2.2 Operation mode / internal ........................................................................................................................................................98
10.2.2.1 Selecting ..................................................................................................................................................................................................................... 98
10.2.2.2 Display in the operating display/ Setting .................................................................................................................................................................... 99
10.2.3 Operation mode / pulse............................................................................................................................................................99
10.2.3.1 Selecting ................................................................................................................................................................................................................... 100
10.2.3.2 Display in the operating display/ Setting .................................................................................................................................................................. 100
10.2.4 Operation mode / current (external standard signal) ..............................................................................................................101
10.2.4.1 Selecting ................................................................................................................................................................................................................... 101
10.2.4.1.1 Setting operation mode / current / user defined 102
10.2.4.2 Display in the operating display ............................................................................................................................................................................... 102
10.3 Configuration.......................................................................................................................................................................102
10.3.1 Overview .................................................................................................................................................................................102
10.3.2 Scrolling the display .................................................................................................................................................................103
10.3.3 Configuration / Language............................................................................................................................................................103
10.3.3.1 Selecting ................................................................................................................................................................................................................... 103
10.3.4 Configuration / Unit ....................................................................................................................................................................103
10.3.4.1 Selecting ................................................................................................................................................................................................................... 103
10.3.5 Configuration / Code ..................................................................................................................................................................104
10.3.5.1 Selecting ................................................................................................................................................................................................................... 104
10.3.5.2 Setting ...................................................................................................................................................................................................................... 104
10.3.6 Configuration / Autostart .............................................................................................................................................................104
10.3.6.1 Selecting ................................................................................................................................................................................................................... 105
10.3.7 Configuration / Metering lock .......................................................................................................................................................105
10.3.7.1 Selecting ................................................................................................................................................................................................................... 105
10.3.8 Configuration / Low-level contact .................................................................................................................................................105
10.3.8.1 Selecting ................................................................................................................................................................................................................... 106
10.3.9 Configuration / Alarm output ........................................................................................................................................................106
10.3.9.1 Selecting ................................................................................................................................................................................................................... 106
10.3.9.2 Conversion from alarm relay mode to contact mode ............................................................................................................................................... 106
10.3.10 Configuration / pulse memory ......................................................................................................................................................107
10.3.10.1 Selecting ................................................................................................................................................................................................................... 107
10.3.10.2 Display in the operating display with an active pulse memory ................................................................................................................................ 107
10.3.11 Configuration / Oval gear meter (only E60PLUS & OGM or OGM PLUS)...................................................................................................108
10.3.11.1 Selecting ................................................................................................................................................................................................................... 108
10.3.12 Configuration / Metering controller (only E60PLUS & OGMPLUS) ..........................................................................................................108
10.3.12.1 Selecting ................................................................................................................................................................................................................... 109
10.3.12.2 Display in the operating display with an active metering controller ......................................................................................................................... 109
10.3.13 Configuration / Metering monitoring ..............................................................................................................................................109
10.3.13.1 Selecting ................................................................................................................................................................................................................... 110
10.3.13.2 Metering monitoring / Stop pump ............................................................................................................................................................................. 110
10.3.13.3 Metering monitoring / Strokes .................................................................................................................................................................................. 110
10.3.13.4 Metering monitoring / Deviation (only at E60PLUS & OGM or OGMPLUS) .................................................................................................................. 111
10.3.13.5 Metering monitoring / Input (only at E60 WITHOUT Dongle box) ........................................................................................................................... 111
10.3.13.6 Oval gear meter pulse display (only E60 PLUS) ......................................................................................................................................................... 112
10.3.14 Configuration / MicroFlowPLUS ......................................................................................................................................................112
10.3.14.1 Selecting ................................................................................................................................................................................................................... 112
10.3.14.2 MicroFlowPLUS / Stop pump ...................................................................................................................................................................................... 113
10.3.14.3 MicroFlowPLUS / Strokes ............................................................................................................................................................................................ 113
10.3.14.4 MicroFlowPLUS / Deviation ......................................................................................................................................................................................... 113
10.3.14.5 MicroFlowPLUS / Metering break ................................................................................................................................................................................ 114
10.3.14.6 MicroFlowPLUS / Metering delay ................................................................................................................................................................................ 114
10.3.14.7 MicroFlowPLUS / Calibration ....................................................................................................................................................................................... 115
10.3.15 Configuration / Batch .................................................................................................................................................................115
10.3.15.1 Selecting ................................................................................................................................................................................................................... 115
10.3.15.2 Batch / Quantity ........................................................................................................................................................................................................ 116
10.3.15.3 Batch / Input (only at E60 WITHOUT Dongle box) .................................................................................................................................................. 117
10.3.15.4 Display in the operating display ............................................................................................................................................................................... 117
10.3.16 Configuration DegasPLUS .............................................................................................................................................................117
10.3.16.1 Selecting ................................................................................................................................................................................................................... 118
10.3.16.2 Degas / Degas strokes ............................................................................................................................................................................................. 118
10.3.16.3 Degas / Degas break ................................................................................................................................................................................................ 119
10.4 Calibration ...........................................................................................................................................................................119
10.4.1 Overview ...............................................................................................................................................................................119
10.4.2 Calibration pump .......................................................................................................................................................................120
10.4.2.1 Preparation ............................................................................................................................................................................................................... 120
10.4.2.2 Calibration / Start ...................................................................................................................................................................................................... 120
10.4.3 Calibration pump with oval gear meter (OGMPLUS) ...........................................................................................................................120
10.4.3.1 Preparation ............................................................................................................................................................................................................... 121
10.4.3.2 Calibration / Start ...................................................................................................................................................................................................... 121
10.4.4 Calibration / Manual ...................................................................................................................................................................122
10.4.4.1 Calibration data table ............................................................................................................................................................................................... 122
10.5 Operating data ....................................................................................................................................................................122
10.5.1 Overview .................................................................................................................................................................................123
10.5.2 Operating data / Operating hours .................................................................................................................................................123
10.5.2.1 Selecting / Displaying / Deleting............................................................................................................................................................................... 123
10.5.3 Operating data / Litre .................................................................................................................................................................123
10.5.3.1 Selecting / Displaying / Deleting............................................................................................................................................................................... 123
10.5.4 Operating data / Amount of pulses ...............................................................................................................................................124
10.5.4.1 Selecting / Displaying / Deleting............................................................................................................................................................................... 124

417101442_KKS_E60.docx - 73 - Rev. 10-06.11


11 Maintenance .................................................................................................................................... 125
11.1 Replacing the suction / return valve ................................................................................................................................125
11.1.1 Inserting the metering valves in the correct positions .......................................................................................................................126
11.2 Replacing the diaphragm and pump head......................................................................................................................126
11.3 Replacement of ceramics cylinder unit with piston........................................................................................................127
11.4 Description of the stroke scale .........................................................................................................................................127
12 Operating faults ............................................................................................................................. 128
12.1 Metering warning messages (display).............................................................................................................................128
12.2 Alarm messages (display).................................................................................................................................................128
12.2.1 Trouble shooting ....................................................................................................................................................................129
13 Wearing parts and spare parts (standard version) .............................................................. 130
13.1 Exploded view.....................................................................................................................................................................130
13.2 Wearing part set .................................................................................................................................................................131
14 Technical Specifications ............................................................................................................. 132
14.1 Pump key ............................................................................................................................................................................132
14.1.1 Pump key definition E60 .............................................................................................................................................................134
14.2 Dimensions .........................................................................................................................................................................135
14.3 Technical specifications "Overview tables" ....................................................................................................................136
14.3.1 General data ............................................................................................................................................................................136
14.3.2 General data ............................................................................................................................................................................136
14.3.3 In-/ and output circuit .................................................................................................................................................................137
14.3.3.1 Connector I ............................................................................................................................................................................................................... 137
14.3.3.2 Connector II .............................................................................................................................................................................................................. 137
14.3.3.3 Connector III ............................................................................................................................................................................................................. 137
14.4 Materials ..............................................................................................................................................................................138
14.5 Connector assignments / Control input and output .......................................................................................................138
14.5.1 Pin assignment / conductor coloring Connector I (3-terminal) ............................................................................................................138
14.5.2 Pin assignment / conductor coloring Connector II (5-terminal) ...........................................................................................................138
14.5.3 Pin assignment / conductor coloring Connector III (4-terminal) ..........................................................................................................138
14.6 Metering rates .....................................................................................................................................................................139
14.7 Delivery capacity in relation to the back pressure .........................................................................................................139
14.7.1 Delivery capacity in relation to the stroke length ..............................................................................................................................140
15 Declaration of Conformity ........................................................................................................... 141

417101442_KKS_E60.docx - 74 - Rev. 10-06.11


1 General
This Technical Manual contains all of the instructions for installing, starting up, maintaining
and repairing membrane metering pumps of the ELADOS EMP KKS E60 and ELADOS
EMP KKS E60PLUS.

IMPORTANT
Please note your pumps software version when using these operating instructions
(see chapter 9.5.1).
The German sections of this manual constitute the ORIGINAL OPERATING MANUAL
NOTE and take legal precedence.
All other languages are translations of the ORIGINAL OPERATING MANUAL.

The safety Notes and emphases must be observed at all times!

1.1 Warranty coverage


Operational safety, reliability and performance of this model are only guaranteed by the
manufacturer if the following conditions are met:
Mounting, connections, adjustment, service and repair are performed by authorized and
trained personnel.
The membrane metering pump must be used according to the specifications in the
operating instructions contained in the delivery scope.
Only original spare parts must be used for repairs.
The warranty claim is invalidated if the pump housing is opened.
In addition, the general warranty and service conditions of the company
ECOLAB Engineering GmbH are applicable.

1.2 Contact address / Manufacturer

ECOLAB Engineering GmbH


Raiffeisenstrae 7
D-83313 Siegsdorf, Germany
Telephone (+49) 86 62 / 61 0
Fax (+49) 86 62 / 61 2 35
eMail: engineering-mailbox@ecolab.com

417101442_KKS_E60.docx - 75 - Rev. 10-06.11


2 Safety
2.1 Safety Notes
Connection and repair work on the membrane metering pump must only be performed by
authorized technical personnel.
The power supply plug must always be disconnected before starting any work on electrical
components.
Appropriate protective clothing must be worn for any maintenance and repair work.
The safety regulations for handling chemicals must always be observed.

2.2 Emphases
The emphases indicated in this maintenance guide have the following meanings:
is used when improper compliance or non-compliance with the operating instructions,
CAUTION work instructions, prescribed working routines, et cetera, may result in injury or accidents.
is used when improper compliance or non-compliance with the operating instructions,
WARNING work instructions, prescribed working routines, et cetera, may result in damage to the
equipment.

IMPORTANT is used when particular attention is required in operating the equipment.

NOTE is used to draw attention to a noteworthy detail.

2.3 Numberings
Numberings marked with this sign () describe an activity which must only be performed
by the installer / user.

2.4 Special safety Notes for maintenance and repair work


Prior to repair and maintenance work and metering of dangerous media, always rinse the
metering head, relieve the pressure pipe and wear protective clothing (protective goggles,
gloves and apron).
Electronics repairs must only be performed by trained electricians, following the safety
CAUTION regulations of the professional association VB G 4 & ZH 1/11)!
When opening covers or removing parts, components carrying live voltages may be
exposed.
Connection points may also be under live voltages.

IMPORTANT Only original spare parts must be used for repairs.

417101442_KKS_E60.docx - 76 - Rev. 10-06.11


3 Delivery scope
The delivery scope consists of:
Fig. 3.1 metering pump, version EMP KKS E60
including mains power supply cable (2 m)
with shock-proof plug and dummy plug for
inputs and outputs

Fig. 3.2 5-terminal connector plug for pulsed or


standard signal input

Fig. 3.3 Adapters


(for tube 4/6, 6/8, 6/12 (ID/AD) mm)

Assembly sketch for tube connections


(accessory)
Connector assignment plan
(accessory)
Fig. 3.4 Short description
(article no. 417101795)
CD Operating Instructions
(article no. 417101793)

3.1 Upgrade accessories for the EMP KKS E60PLUS


Fig. 3.5 Dongle box (article no. 248606)

417101442_KKS_E60.docx - 77 - Rev. 10-06.11


4 Functional description
4.1 Mechanical functions
The ELADOS EMP KKS series of metering pumps take the form of electrically (motor)
driven diaphragm displacement pumps.
The membranes are for the pre-delivery, the piston is for the metering. Because of the
permanent overpuls refeeding this metering pump works self venting.
The metering pumps are suitable for use with clean, non-abrasive metering media with a
viscosity of up to 200 mPas (measuring manner: Brookfield).
The metering pump is operated by a non-blocking synchronous motor and a connecting rod-
eccenter gear.
Fig. 4.1 When the diaphragms (pos. 1) moves towards the
gear, the valve (pos. 2) suck up the metering
product. Simultaneously, vacuum grow out of the
compression chamber of the metering piston
cylinder unit (pos. 3). When the inspection hole
(pos. 4) has been released, the pre-delivered
metering product flows into this chamber.
During the pressure motion metering happens over
the valve (pos. 5); the surplus product get returned
into the container by the return valve (pos. 6). The
stroke adjustment (pos. 7) regulates the volume
delivered during the operation from 0 - 100 %. This
changes the immersion depth of the cylinder. The
pre-delivered amount keeps constant.
To protect the metering device, the use of a suction pipe with an empty reporting device
and dirt arrestor (available from our range of accessories) is highly recommended!
WARNING The empty reporting device switches off the pump if it falls below a certain level (in the
container).

4.2 Electronic functions


The pump is operated using four keys (Fig. 5.5, Pos 2, 3, 4 and 5)
(see chapter 9.3 Key functions").
The operating indicator is shown on a graphical display (Fig. 5.5, Pos 6).

4.2.1 Operation modes


The pump may be used in three different operation modes:
INTERNAL Manual metering function (factory setting)
EXTERNAL pulse control
EXTERNAL standard signal control (mA)
The Configuration menu item can also be used to set batch metering (a specific quantity is
metered on each start pulse).

4.3 Additional electronic functions on the EMP KKS E60PLUS


Oval gear meter connection / Oval gear meter evaluation
Metering regulation with a oval gear meter, type OGMPLUS
Automatic calibration is possible thanks to the oval gear meter, type OGMPLUS
Splitting of the metering lock/pulse/metering monitoring/oval gear meter inputs into
multiple connections to simplify the external connections.

417101442_KKS_E60.docx - 78 - Rev. 10-06.11


5 Setup
5.1 EMP KKS E60
Fig. 5.1 Fig. 5.2 3 4 6 5
6

4 5
3

1
A
2
1 A

5.2 EMP KKS E60PLUS


Fig. 5.3 Fig. 5.4 3 4 6 5

1 B

Pos. Description
1 Suction valve (connection on the suction side)
2 Diaphragm breakage sequence
3 Venting connection (refeeding into the container)
4 Stroke length adjustment
5 Pump head
6 Pressure valve (connection on the pressure side)
A Rail for connecting the dongle box
B Dongle box
Flow direction of the metering medium

5.3 Indicators / Controls / Jacks


5.3.1 EMP KKS E60 and EMP KKS E60PLUS versions
Fig. 5.5 Pos. Description
1 Control knob for setting the stroke length
6
1
2 Menu/Exit, up arrow key
2
3 Menu/Exit, down arrow key
3
4 Start/Stop key (Enter function)
4
5 Test key
5 6 Graphical display
input for low-level advance warning and
I
IV
empty report (see 7.2.2 & 14.5.1)
input for pulse- / standard signal and
II
metering lock (see 7.2.3 & 14.5.2)
I
and empty report, fault report and stroke
II III
III signal (see 7.2.4 & 14.5.3)
IV mains power supply (see 7.2.5)

5.3.2 Dongle box ports


Fig. 5.6 Pos. Description
V input for oval gear meter
VI connection for pulse input to EMP pump (input II)
VII input for batch pulse and metering lock
VIII input for pulse, standard signal input and metering lock

417101442_KKS_E60.docx - 79 - Rev. 10-06.11


6 Mounting
The installation must only be performed by authorized personnel and the general guidelines
WARNING and local installation regulations must be observed!

The metering pump should be fitted in an easy-to-access, frost-free location.


The ambient temperature must not exceed +40 C.
The mounting position of the device must be horizontal.
The pump must be securely screwed to the bracket or the container using the drill holes
provided (for information on the drill hole gap, see chapter 14.2 Dimensions).

6.1 Mounting diagram


Fig. 6.1 Pos Description
1 pressure relief valve
2 metering valve / pressure control valve
3 suction pipe / bottom admission valve

The metering valve, pressure control valve and pressure relief valve can be replaced by a
NOTE multifunction valve (MFV) from our product range, which combines all of these
functionalities.

417101442_KKS_E60.docx - 80 - Rev. 10-06.11


7 Device installation
7.1 Hydraulic installation
7.1.1 Installation examples
The installation examples and applications provided here are of a functional nature. They
NOTE give an overview of installation types which are correct or to be avoided for the correct
functioning of the pump.
Specific measures and protection devices for the metering of dangerous or aggressive
WARNING chemicals are not provided here. When using such chemicals, always observe the legal
regulations and the relevant product datasheet.
A) The arrangement of the metering pump should preferably Fig. 7.1
be made on and/or over the metering container.
For media with a tendency towards
sedimentation, the bottom admisson valve or
NOTE foot valve of the suction line / suction lance
must be fitted above the anticipated layer of
sludge.
B) Between the back-pressure in the injection point and the
pressure at the metering pump a positive difference of
pressure must prevail of at least 1 bar. If this is not the
case, a pressure control valve (2) must be built into the
metering line.
In addition it recommends to install itself for the avoidance
of inadmissibly high pressures in the metering line an
appropriate safety overflow valve (3). The by-pass pipe of
this valve should be led back pressure-free into the
container.
The overflow line never be fed back into
WARNING the suction line of the metering pump.
C) In the injection point in principle a spring-tensioned injector
or metering valve (1) should be inserted (also during a
metering into pressure-free systems).
Fig. 7.2
For metering in pipelines with under pressure, a pressure control
valve (4) must be built into the metering pipe.
A pressure control valve or a metering valve is not
NOTE an absolutely hermetically sealing shutoff device.
To prevent the running out of the metering medium when the pump
is stopped, we also recommend the fitting of a solenoid valve (3)
which is approved for use with the pump.

Pos Designation
1 Injector valve / Metering valve
2 External release
3 Solenoid valve
4 Pressure control valve
Fig. 7.3

The suction pipes must be kept as short as possible.


Long and twisted suction pipes may lead to air build up in the
system.
The max. suction height is 2 m and the max. flow velocity
is 0.3 m/s! (see also chapter 14.3 Technical Specifications)

417101442_KKS_E60.docx - 81 - Rev. 10-06.11


Fig. 7.4

Always lay the suction pipe so that it ascends to the


suction valve of the metering pump.

Fig. 7.5

Installation of a metering monitoring system:


A metering monitoring system oval gear meter or flow
indicator - has to be installed in the metering pipeline
between the pressure relieve valve and the pressure
control resp. metering valve.

7.1.2 Connecting the suction line and return line


Fig 7.6 Pos Description
1 Union nut
2 Clamping piece
3 Connection piece
4 O-ring
5 Fixing hole
When connecting the suction and pressure
pipes, ensure that the O-rings (Pos. 4) are
CAUTION fixed to the connectors so as to achieve the
required seal.
The use of an appropriate suction pipe from
NOTE our product range is recommended.
When using other hose lines adjust the
curved radius correspondingly. The return
CAUTION hose must not be bent. During the
installation make sure that no the return line
is not on tension.

Separate double-hose according to the diagram, cut it straight and remove the connecting
bridge.
Push the union nut (pos. 1) and clamping piece (pos. 2) over the suction hose piece
Attach the connection piece (pos. 3) until stop motion.
Put the O-ring (pos. 4) in valve groove and screw down the union nut by hand.
Pull the return hose piece through the fixing hole (pos. 5) and attach it as suction hose
piece.
Set suction lance into the container.

417101442_KKS_E60.docx - 82 - Rev. 10-06.11


7.1.3 Connection of pressure line
Fig. 7.7 Cut off the metering hose or pipe straight.
Push over the union nut (pos. 2) and crimping ring
(pos. 3).
Attach the hose or the pipe onto the connection
piece (pos. 4) until the stop motion and screw it up
by hand.
Adjust angled position by loosening and screwing
down the nut again (pos. 1).
Observe max. permissible operation
CAUTION pressure of metering hose/pipe!
After 24 hours of operation, the
NOTE metering head screws should be
screwed down diagonally to 3 - 4 Nm.
The metering pump head may contain
CAUTION residual water from the production
tests.

7.2 Electrical installation


7.2.1 Inputs and outputs
Fig. 7.8

V VI I II The inputs and outputs are equipped with protective


caps in the as-delivered condition. These caps must
be removed when necessary. (Pos. I-VIII)
Since the protective caps or connector
plugs are coded, the respective images
NOTE must be observed (I-III). Do not use
force when inserting them.

VII VIII III IV


To protect the electronics against contact with chemicals or humidity, never operate the
metering pump without protective caps or connector cables, since the connectors can
WARNING become oxidized. Mixing up the protective caps may result in malfunctions of the pump
and/or damage to the connectors!

417101442_KKS_E60.docx - 83 - Rev. 10-06.11


7.2.2 Connector assignments of Slot I (3-terminal)
input for low-level advance warning and empty report
Fig. 7.9 Conductor coloring
Pin Assignment
(cable connection)
1 brown Input low-level warning
3 1 3 blue Input empty report
4 black GND ()
4 (plug assignments: see also chapter 14.5.1 Technical Specifications)

7.2.2.1 Installing suction pipe with low-level advance warning and empty report
Slot I must always be assigned, either through the mounted strapping plug (protective cap
with corresponding symbol; see chapter 7.2.1, Fig. 7.9, Pos. I) or through connection to the
NOTE empty report device (suction lance plug). The setup of low level contact is invertible.
(see chapter 10.3.8 Configuration Low level contact)
Fig. 7.10
1+4 = Input low-level warning
low-level advanced warning open:
low-level advanced warning
active (invertible circuit logic, see
chapter 10.3.8), empty report
symbol on display flashes, pump
is not locked.
PIN Assignment
1 Relay input
4 GND ()

3+4 = Input empty report


Switch contact empty report open:
empty report active (invertible
circuit logic, see chapter 10.3.8),
empty report symbol on display
appears, pump is locked.
PIN Assignment
3 Relay input
4 GND ()

417101442_KKS_E60.docx - 84 - Rev. 10-06.11


7.2.3 Connector assignment of slot II (5-terminal)
input for pulse signal, standard signal, metering lock, batch and metering monitoring
Fig. 7.11 Conductor coloring
Pin Assignment
(cable connection)
1 brown output 5 V, DC (loadable with max. 50 mA)
2 pulse input (also as configurable batch / metering
5 2 white
monitoring; see 10.3.13 & 10.3.15)
metering lock (also as configurable batch / metering
3 1 3 blue
monitoring, see 10.3.13 & 10.3.15)
4 black GND ()
4 5 grey Input standard signal 0/4...20 mA
(plug assignments: see also chapter 14.5.2 Technical Specifications)
Remove the protective cap
Mount the connector plug according to the connector assignment.

WARNING Only use a connector plug from our product range! (included in the delivery scope)

7.2.3.1 Installing the pulse control (water meter)


Fig. 7.12 2+4 = Pulse input
with potential-free contact
PIN Assignment
2 Relay input
4 GND ()

Open= empty report active (invertable circuitry logic)


1 + 2 + 4 = Pulse input with electronic
switch (NPN)
PIN Assignment
1 5 V, DC
2 Relay input
4 GND ()

NOTE The minimum pulse- or pause time is 15 ms.

7.2.3.2 Installing the standard signal control


Fig. 7.13
4+5 = Standard signal input
0/4 20 mA
PIN Assignment
4 0/4-20 mA (-)
5 0/4-20 mA (+)

WARNING Observe correct polarity during connection!

417101442_KKS_E60.docx - 85 - Rev. 10-06.11


7.2.3.3 Installing the control via the metering lock
The metering lock function must be activated in menu first. (see chapter: 10.3.7
NOTE Configuring the metering lock). The metering lock is available in all operation modes.
Fig. 7.14 3+4 = Input metering lock with
potential-free contact
PIN Assignment
3 Relay input
4 GND ()
1 +3 + 4 = Input metering lock with
electronic switch (NPN)
PIN Assignment
1 5 V, DC
3 Relay input
4 GND ()

7.2.3.4 Installing the batch function


The batch function must be activated in menu first. The selection must also be made of
NOTE whether the pins 2+4 (input pulse) or 3+4 (input metering lock) should be used for the
batch metering start pulse (see chapter 10.3.15.)
Fig. 7.15

2+4 = Input batch function with potential-free contact with selection input pulse at
configuration / batch (see chapter 10.3.15).
PIN Assignment
2 Relay input
4 GND ()
1 +2 + 4 = Input batch function with electronic switch (NPN) with selection input pulse at
configuration / batch (see chapter 10.3.15).
PIN Assignment
1 5 V, DC
2 Relay input
4 GND ()

or

3+4 = Input batch function with potential-free contact with selection input metering lock at
configuration / batch (see chapter 10.3.15).
PIN Assignment
3 Relay input
4 GND ()
1 +3 + 4 = Input batch function with electronic switch (NPN) with selection input metering lock at
configuration / batch (see chapter 10.3.15).
PIN Assignment
1 5 V, DC
3 Relay input
4 GND ()

417101442_KKS_E60.docx - 86 - Rev. 10-06.11


7.2.3.5 Installing the metering monitoring
The metering monitoring function must be activated in menu first. The selection must also
NOTE be made of whether the pins 2+4 (input pulse) or 3+4 (input metering lock) should be
used for the metering monitoring input (see chapter 10.3.13).
Fig. 7.16

2+4 = Input metering monitoring function with potential-free contact with selection input pulse
at configuration / metering monitoring (see chapter 10.3.13).
PIN Assignment
2 Relay input
4 GND ()
1 +2 + 4 = Input metering monitoring function with electronic switch (NPN) with selection input
pulse at configuration / metering monitoring (see chapter 10.3.13).
PIN Assignment
1 5 V, DC
2 Relay input
4 GND ()

or
3+4 = Input metering monitoring function with potential-free contact with selection input
metering lock at configuration / metering monitoring (see chapter 10.3.13).
PIN Assignment
3 Relay input
4 GND ()
1 +3 + 4 = Input metering monitoring function with electronic switch (NPN) with selection input
metering lock at configuration / metering monitoring (see chapter 10.3.13).
PIN Assignment
1 5 V, DC
3 Relay input
4 GND ()

417101442_KKS_E60.docx - 87 - Rev. 10-06.11


7.2.4 Connector assignments of slot III (4-terminal) output for alarm and stroke signal
Fig. 7.17 Conductor coloring
2 Pin Assignment
(cable connection)
1 brown Output low-level warning, empty report and fault (+)
1
2 white Output low-level warning, empty report and fault (-)
3
3 blue Output stroke signal (+)
4 black Output stroke signal (-)
4 (plug assignments: see also chapter 14.5.3 Technical Specifications)

Remove the protective cap


Mount the connector plug according to the connector assignment.

WARNING Only use a connector plug from our product range! (included in the delivery scope)

7.2.4.1 Installing the alarm or fault report output at 24 V


Fig. 7.18 1+2 = Output low-level warning,
empty report and fault
Input low-level warning active:
relay output connected
Input low-level warning active acc. fault
container active:
relay output closed (function invertible see
chapter 10.3.9 ecc. 7.2.4.3), relay output =
potential-free relay contact, load 24 V
AC/DC 3 A ecc. 115/230V 3A
PIN Assignment
1 Relay output
2 GND ()

At 115V/230 V, a simultaneous connection of contact 1+2 (alarm output) and 3+4 (stroke
ACHTUNG signal output) is generally not permitted.

7.2.4.2 Installing the stroke signal output at 24 V / DC


Fig. 7.19

3+4 = Stroke signal output


The contact is closed once with each
stroke of the pump
Relay output = potential-free transistor
output, load 24 V, DC, 300 mA

PIN Assignment
3 Relay output
4 GND ()

417101442_KKS_E60.docx - 88 - Rev. 10-06.11


7.2.4.3 Hardware migration for alarm contact
Fig. 7.20
After opening and removing the front
of the pump (Fig. 7.20) you can see
the alarm relay with switch contact
(Fig. 7.20, Pos. 1) at the board.
Depending on the position of the
(normally open)
jumper, both the NC and the NO
contact can be selected as the alarm
contact.
To switch, please set jumper 3 from
Pin 1 & 2 up to Pin 2 & 3. 1
In the as-delivered condition, the
normally close is preset. (normally closed)

WARNING:
NOTE Changes to the circuit board may only be performed by service personnel or trained
technical personnel!

7.2.4.3.1 In the alarm output "ON" configuration setting


(see Menu Description in chapter 10.3.9)
If No Alarm If Alarm Power Off
Jumper (Alarm relay has not (Alarm relay has (Alarm relay has not
pulled in) pulled in) pulled in)
Closing function:
contact open contact closed contact open
(Default setting)
Opening function: contact closed contact open contact closed

7.2.4.3.2 In the alarm output OFF configuration setting


(see Menu Description in chapter 10.3.9)
If No Alarm If Alarm Power Off
Jumper (Alarm relay has (Alarm relay has not (Alarm relay has
pulled in) pulled in) pulled in)
Closing function:
contact closed contact open contact open *
(Default setting)
Opening function: contact open contact closed contact closed
* fail-safe function, (safe in the event of failure)

7.2.5 Connector assignments of slot IV, mains power supply


Fig. 7.21 The mains power supply enters through a four-terminal frontal plug connector.
This already has a plug screwed into it in the factory.
Pin Conductor coloring Assignment
(cable connection)
L1 black Mains / external conductor
N blue Neutral wire
PE yellow / green Protective earth wire
* - Not assigned
To ensure the imperviousness of the mains power connection to humidity, the gasket
NOTE (contained in the delivery scope and already built-in in the as-delivered condition) must be
inserted and the fixing screw tightened into the middle of the plug.
Connect the mains power supply cable to the power grid.

417101442_KKS_E60.docx - 89 - Rev. 10-06.11


8 Upgrading the EMP KKS E60 to the EMP KKS E60PLUS
To upgrade the EMP KKS E60 to the EMP KKS E60PLUS and thus access the additional
functions, obtain the dongle box from our range of accessories. (Part No. 248606).

8.1 Fitting the dongle box


Fig. 8.1 Pos. Description
V input for oval gear meter
Fixed connector cable for connecting the pulse input to the
VI
EMP pump (input II)
1 Connection wire for connection to input II of the pump
2 Dongle box
VII input for batch pulse and metering lock
VIII input for pulse, standard signal input and metering lock

Fig. 8.2 Fig. 8.3

1
2
Fit the dongle box (Fig. 8.1) to the rail of the EMP pump provided for this purpose
(Fig. 8.2, pos. A):
Slide the dongle box (Fig. 8.1) onto the rail on the left side of the EMP pump
(Fig. 8.2, pos A), until it snaps into place.
Connect the connection cable (Fig. 8.1, pos. 3 and 8.3, pos. 2) to the input for pulse /
standard signal (Fig. 8.2, pos 1).
Switch the pump off and afresh on.
The additional functions in the metering pump electronics can thus be activated and executed.
If, before upgrading with a dongle box, a plug is connected to the input for pulse / standard
NOTE signal (see Fig. 8.2, pos. 1), then this plug can be connected after the upgrade to plug VIII
(see Fig. 8.1, pos. VIII) of the dongle box.

417101442_KKS_E60.docx - 90 - Rev. 10-06.11


8.2 Connector assignments of the slots
8.2.1 Connector assignments of slot V (5-terminal), input for oval gear meter
Fig. 8.4 Conductor coloring Assignment
Pin
(cable connection)
1 brown Supply for oval gear meter 5 V DC (load with max. 50 mA)
PLUS
2 white Bus line for oval gear meter, type OGM
3 blue Switch input
4 black GND ()
5 grey Free for future use
Remove the protective cap
Mount the connector plug according to the connector assignment.

WARNING Only use a connector plug from our product range!

8.2.1.1 Installing the oval gear meter (OGM or OGMPLUS)


Plus
The oval gear meter function must be activated in menu first. If a OGM is attached, the
NOTE function oval gear meter is activated automatically. (see chapter 10.3.15).
Fig. 8.5 1 +3 + 4 = OGM ecc. other flow control
with electrical switch
output
PIN Assignment
1 5V
3 Relay input
4 GND ()
PLUS
1 + 2 + 3+ 4 = OGM
PIN Assignment
1 5V
2 Bus signal
3 Relay input
4 GND ()

417101442_KKS_E60.docx - 91 - Rev. 10-06.11


8.2.2 Connector assignments of Slot VII (5-terminal)
input for batch pulse and metering lock
Fig. 8.6 Conductor coloring
Pin (cable connection)
Assignment
1 brown Output 5 V, DC (load with max. 50 mA)
2 white Input batch metering
3 blue Input metering lock
4 black GND ()
5 grey Free for future use
Remove the protective cap
Mount the connector plug according to the connector assignment.

WARNING Only use a connector plug from our product range!

8.2.2.1 Installing the batch pulse


The batch function must be activated in menu first. The selection must also be made of
HINWEIS whether the pins 2+4 (input pulse) or 3+4 (input metering lock) should be used for the
batch metering start pulse (see chapter 10.3.15.)
Fig. 8.7

2+4 = Input batch metering with potential-free contact with selection input pulse at
configuration / batch (see chapter 10.3.15).
PIN Assignment
2 Relay input
4 GND ()
1 +2 + 4 = Input batch metering with electronic switch (NPN) with selection input pulse at
configuration / batch (see chapter 10.3.15)
PIN Assignment
1 5 V, DC
2 Relay input
4 GND ()

or
3+4 = Input batch metering with potential-free contact with selection input metering lock at
configuration / batch (see chapter 10.3.15).
PIN Assignment
3 Relay input
4 GND ()
1 +3 + 4 = Input batch metering with electronic switch (NPN) with selection input metering lock at
configuration / batch (see chapter 10.3.15).
PIN Assignment
1 5 V, DC
3 Relay input
4 GND ()

417101442_KKS_E60.docx - 92 - Rev. 10-06.11


8.2.2.2 Installing the metering lock (optional connector VII or VIII)
The metering lock function must be activated in menu first. The selection must also be
HINWEIS made of whether the pins 2+4 (input pulse) or 3+4 (input metering lock) should be used
for the metering monitoring input (see chapter 10.3.15).
Fig. 8.8 3+4 = Input metering monitoring
with potential-free contact,
with selection metering
lock at configuration
metering monitoring
(see chapter 10.3.13).
PIN Assignment
3 Relay input
4 GND ()

1 +3 + 4 = Input metering monitoring with electronic switch (NPN) with selection input metering
lock at configuration metering monitoring (see chapter 10.3.13).
PIN Assignment
1 5 V, DC
3 Relay input
4 GND ()

8.2.3 Connector assignments of Slot VIII (5-terminal)


input for pulse, standard signal input and metering lock
Fig. 8.9 Conductor coloring
Pin Assignment
(cable connection)
1 brown Output 5 V, DC (load with max. 50 mA)
2 white Input external pulse
3 blue Input metering lock
4 black GND ()
5 grey Input standard signal 0/4-20 mA
Remove the protective cap
Mount the connector plug according to the connector assignment.

WARNING Only use a connector plug from our product range!

8.2.3.1 Installing the pulse control (water meter)


Fig. 8.10 2+4 = Pulse input with potential-
free contact
PIN Assignment
2 Relay input
4 GND ()

1 + 2 + 4 = Pulse input with electronic


switch (NPN)
PIN Assignment
1 5 V, DC
2 Relay input
4 GND ()

NOTE The minimum pulse- or pause time is 15 ms.

417101442_KKS_E60.docx - 93 - Rev. 10-06.11


8.2.3.2 Installing the standard signal (mA)
Fig. 8.11
4+5 = Standard signal input
0/4 20 mA
PIN Assignment
4 0/4-20 mA (-)
5 0/4-20 mA (+)

WARNING Observe correct polarity during connection!

8.2.3.3 Installing the metering lock


The metering lock function must be activated in menu first. (see chapter: 10.3.7
HINWEIS configuration metering lock) The metering lock is available in all operation modes.
Fig. 8.12 3+4 = Metering lock input with
potential-free contact
PIN Assignment
3 Relay input
4 GND ()
1 +3 + 4 = Metering lock input with
electronic switch (NPN)
PIN Assignment
1 5 V, DC
3 Relay input
4 GND ()

417101442_KKS_E60.docx - 94 - Rev. 10-06.11


9 Startup
9.1 Switching on the pump
Fig. 9.1
2 sec Press START/STOP key (min. 2 sec.).

9.2 Switching off the pump


Fig. 9.2
5 sec Press START/STOP key (min. 5 sec.).

9.3 Key functions


Key Description
Fig. 9.3
MENU/EXIT function entry and exiting of the menu levels
(keep keys pressed down together)

() Modify set values upwards

() Modify set values downwards


Fig. 9.4
Start the pump
Stop the pump
Confirmation key (ENTER) for set values
Fig. 9.5
Test function (endurance test)

9.4 Description of display symbols


Display Description
Pumps operation mode: the top right indicator in the display makes a full rotation with each stroke.
Level report is active (flashing display = low level advance warning, display is permanently visible =
empty report), see chapter 7.2.2.1 Installing the suction pipe with low-level advance warning and
empty report or see chapter 10.3.8 Configuration / Low-level contact
Metering lock active, see chapter 7.2.3.3 Installing the control via the metering lock or see chapter
10.3.7 Configuration / Metering lock
Fault report, see chapter 12.2 Alarm messages
Intern Operation mode internal, see chapter 10.2.2 Operation mode / internal
MUL Operation mode pulse multiplication, see chapter 10.2.3 Operation mode / pulse
DIV Operation mode pulse division, see chapter 10.2.3 Operation mode / pulse
x..xx mA Operation mode current x xx mA, see chapter 10.2.4 Operation mode / current
Charge Operation mode batch see chapter 10.3.15 Configuration / Batch
xxx /min Display strokes / min at Operation mode internal
xx % Display % at Operation mode internal
x.xx l/h Display l/h at Operation mode internal , see chapter 10.2.2.2 Display / setting operation mode internal
n= x Display at operation mode pulse, see chapter 10.2.3.2 Display / setting operation mode pulse
xx.x mA Display at operation mode current, see chapter 10.2.4.2 Display / operation mode current
f = xx.x % Display of the current metering frequency in %
OFF Pump is in operating state OFF (must be switched on), see chapter 9.5.2 Display at operating display
Plus
E60+ Dongle box is connected, see chapter 8 Upgrading to Version Chem-Ad Serie A E60
PLUS
Dongle box and OGM are connected, see chapter 8.2.1.1 Installing the oval gear meter or see
E60++
chapter 10.3.11 Configuration / Oval gear meter
PLUS
MicroFlow MicroFlow conected, see chapter 10.3.14 Configuration / MicroFlow
Alarm Alarm operation mode, see chapter 12.2 Alarm messages

417101442_KKS_E60.docx - 95 - Rev. 10-06.11


9.5 Initial startup / Delivery status
In the as-delivered condition, the pump is configured as follows:
Operation mode: Internal
Stroke frequency: 122 strokes/min (max. at 50 Hz) or 146 strokes/min (max. at 60 Hz)
Status: pump in the "OFF" ("Standby" in V 4.0) operating state
To change the preconfigured factory settings, observe the corresponding menu items in
NOTE chapter 10.3 "Configuration".

9.5.1 Software version display


Fig. 9.6
The current software version (1) is displayed in the top right
of the main menu screen (Fig. 9.6 & 9.7).
Lowercase letters after the software number (2) describe
internal software modifications that do not affect the
operation of the device.
Fig. 9.7

If a dongle box or a MicroFlowPLUS has been connected, the


unit version (3) is displayed to the right of the pump version.

9.5.2 Display at operating display


On delivery, the following basic factory settings appear on the display when the main
voltage is switch on.
Fig. 9.8
Operating mode: internal
Metering frequency / - quantity: strokes/min (122 strokes/min at 50 Hz,
146 strokes/min at 60 Hz)
Operating state: OFF (in V 4.1, Standby in V4.0
(to start the pump press START / STOP key)

NOTE With each stroke of the pump, the indicator in the upper right of the display rotates 1 turn.

9.5.3 Configuration
The following factory settings are defined in the configuration.
Fig. 9.9 Configuration of Standard see chapter
language: German 10.3.3
unit: litre 10.3.4
code: not active (-) 10.3.5
auto start: not active (-) 10.3.6
metering lock: not active (-) 10.3.7
low level contact: open () 10.3.8
alarm output: off () 10.3.9
pulse memory: not active (-) 10.3.10
oval gear meter: not active (-) 10.3.11
metering controler: not active (-) 10.3.12
meter monitor: not active (-) 10.3.13
microflow : not active (-) 10.3.14
batch: not active (-) 10.3.15
degas: not active (-) 10.3.16
microflow Only appears on the display in conjunction with the
MicroFlowPLUS metering monitor, which is available as an
accessory.

417101442_KKS_E60.docx - 96 - Rev. 10-06.11


10 Menu description
10.1 Main menu
The main menu can be accessed while the pump is operating.
It is started by simultaneously pressing the and keys.
Simultaneously press the and keys again to return to the operating display.

10.1.1 Overview
Fig. 10.1

Operation mode see chapter 10.2

Configuration see chapter 10.3

Calibration see chapter 10.4

Operating data see chapter 10.5

417101442_KKS_E60.docx - 97 - Rev. 10-06.11


10.2 Operation mode
10.2.1 Selecting
Fig. 10.2

Adjustments see chapter:


internal 10.2.2
pulse 10.2.3
current 10.2.4

10.2.2 Operation mode / internal


The internal operation mode can be used to operate the metering pump without external
signals.
The following display options can be selected:
Strokes/min The configured metering speed (and thus the metering rate)
is displayed in strokes/min. (Default setting)
Percent The configured metering speed (and thus the metering rate)
is displayed as a percentage.
Liter* The configured metering rate is displayed in litres/h
(optionally also in gallons/day or gallons/h).
For information on converting litres to gallons, see chapter 10.3.4

10.2.2.1 Selecting
Fig. 10.3

417101442_KKS_E60.docx - 98 - Rev. 10-06.11


10.2.2.2 Display in the operating display/ Setting
The metering rate can be configured/adjusted in the operating display during operations.
If the newly set value is not confirmed within 10 seconds by pressing the START/STOP
NOTE key, the system reverts to the primarily value.
Strokes/min
Fig. 10.4

Percent (%)
Fig. 10.5

Liter/min Gallons/day
Fig. 10.6 Fig. 10.7

10.2.3 Operation mode / pulse


For the pulse operation mode, the metering pump only works in conjunction with incoming
pulses (e.g. from a contact water meter).
The following pulse processing options can be selected:
Multiplication Incoming pulses are multiplied by a configurable factor (n):
1 pulse = n pump strokes (default setting)
Division Incoming pulses are divided by a configurable factor (n):
n pulse = 1 pump strokes

417101442_KKS_E60.docx - 99 - Rev. 10-06.11


10.2.3.1 Selecting
Fig. 10.8

10.2.3.2 Display in the operating display/ Setting


The multiplication and division factors are configured/adjusted in the operating display.
This can take place while the pump is operating.
Multiplication
Fig. 10.9

If the newly set value is not


confirmed within 10
seconds by pressing the
NOTE START/STOP key, the
Division system reverts to the
Fig. 10.10 previously set running
value.

417101442_KKS_E60.docx - 100 - Rev. 10-06.11


10.2.4 Operation mode / current (external standard signal)
In the current operation mode, the pump functions on the basis of an incoming standard
signal. The incoming signal (0/4-20 mA; 20-0/4 mA or adjustable) is converted into a
metering frequency 0-100 % (stroke/pause ratio), e.g.:
The following operating options can be selected:
0 20 mA 0 mA = 0% metering frequency, 20 mA = 100 % metering frequency
4 20mA 4 mA = 0% metering frequency, 20 mA = 100 % metering frequency
20 0 mA 20 mA = 0% metering frequency, 0 mA = 100 % metering frequency
20 4 mA 20 mA = 0% metering frequency, 4 mA = 100 % metering frequency
User defined n (adjustable) mA = 0 % metering frequency,
n (adjustable) mA = 100 % metering frequency

10.2.4.1 Selecting
Fig. 10.11

see chapter 10.2.4.1.1

417101442_KKS_E60.docx - 101 - Rev. 10-06.11


10.2.4.1.1 Setting operation mode / current / user defined
NOTE The difference in the set values must be greater than or equal to 5. (e.g. min 10 max 15).
Fig. 10.12

10.2.4.2 Display in the operating display


Display Pos Description
Fig. 10.13
1 Range of input signal, preset in the menu

2 Actual connected current value

3 Stroke frequency in %

10.3 Configuration
10.3.1 Overview
Fig. 10.14 Configuration of: see chapter:
Menu language 10.3.3
Units 10.3.4
Code entry 10.3.5
Startup settings 10.3.6
Metering lock 10.3.7
Low-level contact 10.3.8
Alarm output 10.3.9
Pulse memory 10.3.10
Oval gear meter 10.3.11
Metering controller 10.3.12
Metering monitoring 10.3.13
MicroFlow 10.3.14
This menu item only appears in conjunction with the
MicroFlow metering monitor, which is available as an
accessory, and replaces the menu item metering
monitoring.
Batch 10.3.15
Degas 10.3.16

417101442_KKS_E60.docx - 102 - Rev. 10-06.11


10.3.2 Scrolling the display
Fig. 10.15 The display possesses a "scroll function", i.e. some menu items are
only shown on the display when the end of the menu is reached on
the display.
Using the symbols (1) or (2) on the display, you can see which
direction you can scroll in.
1 = ()scroll the display upwards
2 = ()scroll the display downwards

10.3.3 Configuration / Language


This is used to select the menu language.

10.3.3.1 Selecting
Fig. 10.16

Default setting = German

10.3.4 Configuration / Unit


If litre is selected for the internal operation mode (see chapter 10.2.2), this can be used to
change the display from litres/h to gallons/day (1 gallon = 3.785 litres).

10.3.4.1 Selecting
Fig. 10.17

Default setting = liter

417101442_KKS_E60.docx - 103 - Rev. 10-06.11


10.3.5 Configuration / Code
With this setting, a four-digit number combination can be assigned to secure the setting
against unauthorized adjustment.
If code has been activated, the four-digit code must be entered before configured values
can be amended or the main menu can be accessed.

10.3.5.1 Selecting
Fig. 10.18

- Code query inactive.


(Default setting)

Code query active.

see chapter 10.3.5.2

10.3.5.2 Setting
Fig. 10.19

10.3.6 Configuration / Autostart


This function determines whether the pump is set to OFF (Standby in V 4.0) when the
mains connection is re-established following a power cut or if the pump should immediately
recommence functioning in the configured operation mode.

417101442_KKS_E60.docx - 104 - Rev. 10-06.11


10.3.6.1 Selecting
Fig. 10.20

- autostart is inactive.
When the mains voltage is connected,
the pump always enters the "OFF"
(Standby in V 4.0) operating state.
(Default setting)

autostart is active.
When the mains voltage is connected,
the pump starts functioning in the
configured operation state.

10.3.7 Configuration / Metering lock


If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II (or at plug VII or plug VIII, if a dongle box is used) between PINS 3+ 4
and an external enable contact is connected (electrical connection see chapter 7.2.3.3,
8.2.2.2 and 8.2.3.3). The selected operating mode does not affect the use of the metering
lock.

10.3.7.1 Selecting
Fig. 10.21

- interrogation of the metering lock


is inactive. (Default setting)

interrogation of the metering lock


is active.

10.3.8 Configuration / Low-level contact


This function specifies whether an open or a closed contact at the level input
(plug I, see chapter 7.2.2.1) is regarded as level OK.

417101442_KKS_E60.docx - 105 - Rev. 10-06.11


10.3.8.1 Selecting
Fig. 10.22

= contact open:
level not OK (empty)
contact closed:
level OK (full)
(Default setting)

= contact closed:
level not OK (empty)
contact open:
level OK (full)

10.3.9 Configuration / Alarm output


This option permits the inversion of the alarm output (alarm output relay has pulled in or not
pulled in when the alarm was triggered).

10.3.9.1 Selecting
Fig. 10.23

= When an alarm is triggered, the


relay is pulled in for the alarm
output.
(Default setting)
= When an alarm is triggered, the
relay is not pulled in for the alarm
output.
In addition to the function mode of the
relay, it is also possible to select
whether the alarm output relay contact
is closed (closing function on, default
setting) when the relay is pulled in or
open (opening function) (see chapter
7.2.4.3 conversion from alarm relay
mode to contact mode).

10.3.9.2 Conversion from alarm relay mode to contact mode


See chapter 7.2.4.3

417101442_KKS_E60.docx - 106 - Rev. 10-06.11


10.3.10 Configuration / pulse memory
If the incoming pulse rate is higher than the maximum pulse rate that the pump can process
(max. pump frequency e.g. 122 strokes/min at 50 Hz), the pulses that cannot be processed
can be stored.
The stored pulses are processed once no further external pulses are received. This means
that the pump continues to function even though there is no external running condition.
WARNING In the worst case, this can lead to metering taking place into a closed system and resulting
in impermissibly high pressure in the system. This must be prevented through appropriate
safety measures.
The memory content is erased by activating the metering lock or switching off the pump.

10.3.10.1 Selecting
Fig. 10.24

- pulse memory is inactive.


(Default setting)

pulse memory is active.

10.3.10.2 Display in the operating display with an active pulse memory


Display in operation Meaning Pos Description
Fig. 10.25 1 Pulse memory active
Pulse multiplication 2 Number of pulses received
3 Set factor
(Example:
10 external pulses
become 20 strokes)

Fig. 10.26
Pulse division
(Example:
10 external pulses
become 20 strokes)

417101442_KKS_E60.docx - 107 - Rev. 10-06.11


10.3.11 Configuration / Oval gear meter (only E60PLUS & OGM or OGM PLUS)
The oval gear meter function makes it possible to record a real value in the operating
data/litre menu item (see chapter 10.5.3).
Furthermore, this menu item must be enabled to use the metering controller function
(see chapter 10.3.12).
The function for oval gear meter can only be activated if the pump is upgraded with a
PLUS
dongle box to the E60 and a standard oval gear meter (see accessories) is
connected.
NOTE To activate the Dongle-Box in connection with the oval gear meter, the power supply has
to be switched off and on again! (Unplug power plug or switch the pump off and back on
again!)
PLUS
The oval gear meter function is automatically activated when an OGM is connected.

10.3.11.1 Selecting
Fig. 10.27

- oval gear meter is inactive.


(Default setting)

oval gear meter is active.

10.3.12 Configuration / Metering controller (only E60PLUS & OGMPLUS)


Fig. 10.28

If an OGM Plus is connected, when the metering controller function is activated, the dosage
quantity measured by the OGM is compared with a pre-defined dosage quantity target
value. If there is a discrepancy between the values, the metering frequency of the pump is
automatically increased or decreased.
Since metering frequency can only be adjusted within the performance limitations of the
pump, setting the dosage quantities higher than 80 or 90% of the maximum possible
metering frequency is not recommended. This will ensure that the metering controller retains
sufficient reserves to react to negative control deviations.
The metering controller function can only be used in the 'internal' and 'current' operating
modes. If the operating mode 'pulse' is selected, the metering controller function will not
work.
The metering controller function can only be activated if the pump is upgraded with a
PLUS PLUS
dongle box to the E60 and oval gear meter , type OGM (see Accessories) is
NOTE connected.
To activate the Dongle-Box in connection with the oval gear meter, the power supply has
to be switched off and on again!

417101442_KKS_E60.docx - 108 - Rev. 10-06.11


10.3.12.1 Selecting
Fig. 10.29

- controller function is inactive.


(Default setting)

controller function is active.

10.3.12.2 Display in the operating display with an active metering controller


Fig. 10.30 = Downward metering divergence
The pump is currently delivering less than the preset stroke
frequency (here 100/min for example) requires.
Metering frequency is increased automatically until the actual
value matches the target value.
Fig. 10.31
- = No metering divergence
The pump delivers exactly the preset flow (here 100/min for
example).
No correction is necessary.
Fig. 10.32 = Upward metering divergence
The pump is currently delivering more than the preset stroke
frequency (here 100/min for example) requires.
Metering frequency is reduced automatically until the actual
value matches the target value.
Fig. 10.33
Dongle-box mounted.
NOTE
Oval gear meter OGMPLUS mounted.

10.3.13 Configuration / Metering monitoring


If the metering monitoring function is enabled, the pump strokes are compared to the
incoming pulses using a connected external metering monitor (e.g. oval gear meter). If a
configurable tolerance threshold is breached, an alarm is triggered.
The metering monitoring system can be connected at plug II (or plug V if a dongle box is
used) at Pin 2+4 (input pulse) or at Pin 3+4 (input metering lock) (assortment of inputs see
chapter 10.3.13.5, electrical connection see chapter 7.2.3.5 and 8.2.1.1).
If an oval gear meter is connected as a metering monitoring unit and should be
NOTE correspondingly evaluated, then the configuration/oval gear meter function must be
enabled in addition to the configuration/metering monitoring function (see chapter 10.3.11).

417101442_KKS_E60.docx - 109 - Rev. 10-06.11


10.3.13.1 Selecting
Fig. 10.34

- metering monitoring is inactive.


(Default setting)

metering monitoring is active.

On activating metering monitoring, a


submenu appears with the following
menu items:
Menu item see chapter
Stop pump 10.3.13.2
Strokes 10.3.13.3
Deviation 10.3.13.4
Input 10.3.13.5

10.3.13.2 Metering monitoring / Stop pump


The stop pump function is used to set whether or not the pump should be stopped if a
metering monitoring alarm is triggered.
Fig. 10.35

- Pump is not stopped


when a metering monitoring alarm
is triggered. (Default setting)

Pump is stopped
when a metering monitoring alarm
is triggered.

10.3.13.3 Metering monitoring / Strokes


The strokes option indicates the stroke interval to be monitored.
Fig. 10.36

Setting range: 0 100

Default setting = 10

417101442_KKS_E60.docx - 110 - Rev. 10-06.11


10.3.13.4 Metering monitoring / Deviation (only at E60PLUS & OGM or OGMPLUS)
A tolerance in % is set under deviation.
The actual incoming pulse rate recorded by the oval gear meter within the pump interval to
be monitored (see chapter 10.3.13.3 configuration/strokes) is compared with the target
pulse rate defined during calibration.
If this comparison results in a deviation that is greater than the % value configured under
deviation, a metering monitoring alarm is triggered.
This function can only be selected if a dongle box is connected and configuration/oval
NOTE gear meter (see chapter 10.3.11) has been activated.
Fig. 10.37

Setting range: 0-100%

Default setting = 20 %

10.3.13.5 Metering monitoring / Input (only at E60 WITHOUT Dongle box)


The Input setting is used to determine which input (pulse input or metering lock) at plug II
(or at plug V, if a dongle box is used)of the pump should be used to evaluate the incoming
pulses from the metering monitoring unit.
The flow monitor connection depends on the selected input:
Input pulse: = plug II (or plug V) Pin 2+4
Input metering lock: = plug II (or plug V) Pin 3+4
see chapter 7.2.3.5.
This function can only be selected if no dongle box is connected.
NOTE In this case, the original function (e.g. pulse input) can no longer be used.
Fig. 10.38

417101442_KKS_E60.docx - 111 - Rev. 10-06.11


10.3.13.6 Oval gear meter pulse display (only E60 PLUS)
Fig. 10.39 This display shows the number of pulses recorded
during the last calibration process (running time
during calibration = 1 min).
If the value shown is less than 60, metering
monitoring using an oval gear meter is only
possible to a limited extent.

10.3.14 Configuration / MicroFlowPLUS


PLUS
If the MicroFlow metering monitoring unit (article no. 248611) is connected to plug II
of the pump and the Plug & Play function is activated through the temporary removal of
the supply voltage or the pump being switched off and back on again, the
NOTE configuration/meter monitoring menu item is automatically replaced by the
configuration/MicroFlow menu item.
PLUS
When installing/commissioning the MicroFlow metering monitoring system, please
consult the operating manual, product no. 417101314.
This function makes it possible to use a metering monitoring system with which a metering
pulse is emitted and evaluated on every pump stroke.
The stored default settings for strokes, deviation, metering break and metering
delay can only be seen as presets.
NOTE Depending on the characteristics of the facility (e. g. kind of chemical, metering volume,
cross sections, pipe lengths, etc.), the sensitivity of the MicroFlow system must be
individually adjusted to the on-site conditions by changing the parameters listed above.

10.3.14.1 Selecting
Fig. 10.40
PLUS
- MicroFlow is inactive.
(Default setting)
PLUS
MicroFlow is active.

PLUS
On activating MicroFlow ,a
submenu appears with the
following menu items:
Menu item see chapter
Stop pump 10.3.14.2
Strokes 10.3.14.3
Deviation 10.3.14.4
Metering break 10.3.14.5
Metering delay 10.3.14.6
Calibration 10.3.14.7

417101442_KKS_E60.docx - 112 - Rev. 10-06.11


10.3.14.2 MicroFlowPLUS / Stop pump
Fig. 10.41
The stop pump function is used
to set whether or not the pump
stops if a metering monitoring
alarm is triggered.
- Pump is not stopped in the
event of an Alarm metering
monitor function
(Default setting)

Pump is stopped in the event of


an Alarm metering monitor
function

10.3.14.3 MicroFlowPLUS / Strokes


Fig. 10.42

The "Strokes" option is used to


specify the interval of strokes to
be monitored.
Setting range: 0-100

Default setting = 40 strokes

10.3.14.4 MicroFlowPLUS / Deviation


The "Deviation" option is used to specify the number of undetected strokes permitted during
the stroke interval to be monitored (see chapter 10.3.14.3 "Strokes") before the metering
monitoring function issues an alarm.
Fig. 10.43

Example: Strokes = 40,


deviation = 20
In this example, 20 unrecognized
strokes are accepted within a 40
strokes interval. If 21 strokes
remain unrecognized, the system
releases an alarm signal.
Setting range: 0-100
Default setting = 20

417101442_KKS_E60.docx - 113 - Rev. 10-06.11


10.3.14.5 MicroFlowPLUS / Metering break
When handling media with a tendency to emit gas, gas bubbles form in the system after
extended downtimes, resulting in corrupted volume values of the quantity to be metered and
subsequently to the non-detection of the metering strokes by the MicroFlowPLUS and the
issuance of an alarm.
Fig. 10.44
Metering break is used to set
the period without metering after
which the monitoring system is
deactivated for a specific time
(see 10.3.14.6 MicroFlowPLUS /
Metering delay) to prevent the
undesired activation of the
monitoring system.
Setting range: 2 - 3600s

Default setting = 240 sec.

10.3.14.6 MicroFlowPLUS / Metering delay


Use the "Metering delay" option to specify the time during which the metering monitoring
function is disabled when handling out gassing media to allow time for degassing the
system.
Once the metering pause time has expired, the "Metering delay" is activated as soon as the
next metering is initiated (see chapter 10.3.14.5).
Example: Metering pause = 240 s, metering delay = 40 s
This example has a metering pause of 240 seconds during which metering is stopped. The
metering delay of 40 seconds is initiated with the next metering request during which the
metering monitoring of the MicroFlowPLUS is interrupted.
Fig. 10.45

Any gas bubbles can be removed


from the system without triggering
an alarm during this time.

Setting range: 2 - 3600s

Default setting = 40 sec.

417101442_KKS_E60.docx - 114 - Rev. 10-06.11


10.3.14.7 MicroFlowPLUS / Calibration
Use the "Calibration" option to newly calibrate the transducer during initial installation or
when changing the product.
During the calibration, the pump must be operating with the required setting, and the
IMPORTANT metering medium must be free from bubbles when flowing through the measuring
sensor.
On activating the calibration function, the values for min. conductivity (electrical connection
between the sensor pegs in the measuring sensor disrupted) und max. conductivity
(electrical connection) are determined.
Fig. 10.46

These values are then used to calculate


and display a difference.
To monitor the system well, the
difference should be greater than 3..4.

10.3.15 Configuration / Batch


NOTE The pump must be calibrated before using batch metering (see chapter 10.4).

When activating batch mode with a signal to the metering lock/pulse input (plug II) (or at
plug VII if a dongle box is used) pin 2+4 (input pulse) or pin 3+4 (input metering lock), a
previously defined quantity is metered with 100 % stroke frequency (assortment of inputs
see chapter 10.3.13.5, electrical connection see chapter 7.2.3.4 and 8.2.1.1).
The batch metering can be interrupted by deactivating the release (metering lock) or
switching off the pump.

10.3.15.1 Selecting
Fig. 10.47

- Batch is inactive
(Default setting)

Batch is active

If batch metering is active, the


following items appear in the
submenu:
Menu item see chapter
Quantity 10.3.15.2
Input 10.3.15.3

417101442_KKS_E60.docx - 115 - Rev. 10-06.11


10.3.15.2 Batch / Quantity
Quantity is used to establish the desired metering quantity (in l, ml, l or G) per batch
metering process. Setting range: 0 99999
Fig. 10.48

417101442_KKS_E60.docx - 116 - Rev. 10-06.11


10.3.15.3 Batch / Input (only at E60 WITHOUT Dongle box)
The Input setting is used to determine which input (pulse input or metering lock) at plug II
(or at plug VII if a dongle box is used) of the pump should be used to evaluate the start
pulse for the batch metering.
The start pulse cable connection depends on the selected input:
Input pulse = plug II (or plug VII) Pin 2+4
Input metering lock = plug II (or plug VII) Pin 3+4
see chapter 7.2.3.4 and 8.2.2.1.
In this case, the original function (e.g. pulse) can no longer be used.
NOTE When using a dongle box, a separate input is available.
Fig. 10.49

Default setting = Metering lock

10.3.15.4 Display in the operating display


Fig. 10.50 Pos Description
1 Operation mode
2 Quantity remaining to be metered
3 Strokes remaining to be executed

10.3.16 Configuration DegasPLUS


On activating the DegasPLUS function and connecting an appropriate degassing valve, this
function enables the metering system to be degassed for a controlled time period. When
installing/commissioning the degassing valve, please consult the appropriate operating
manual, product no. 417101377.

417101442_KKS_E60.docx - 117 - Rev. 10-06.11


10.3.16.1 Selecting

Fig. 10.51

PLUS
- Degas is inactive
(Default setting)

PLUS
Degas is active

If degassing control is active, the


following items appear in the
submenu:
Menu item see chapter
Degas strokes 10.3.16.2
Degas break 10.3.16.3

10.3.16.2 Degas / Degas strokes


Fig. 10.52

The number of strokes that should


be processed during a degassing
interval is recoded under degas
strokes.
Setting range: 1-100

Default setting = 0

417101442_KKS_E60.docx - 118 - Rev. 10-06.11


10.3.16.3 Degas / Degas break
The time between two degassing intervals is set under degas break.
If a metering request is submitted during this period, this is processed and the DegasPLUS
break time is reset and restarted.
Setting range: hours 00 - 23
minutes 00 - 59
total 00.01 - 23.59h
Fig. 10.53

Default setting
= 00:00

10.4 Calibration
10.4.1 Overview
The procedure and display during the calibration process differ depending on whether or not
an oval gear meter is connected.
Fig. 10.54
Calibration pump:
see chapter 10.4.2
Calibration pump with
oval gear meter:
see chapter 10.4.3

417101442_KKS_E60.docx - 119 - Rev. 10-06.11


10.4.2 Calibration pump
10.4.2.1 Preparation
Fig. 10.55
Connect the pump ready for operation
on the pressure side
(see chapter 7 Installing the device).
Fill a suitable measuring cylinder and
insert the suction line or suction and
return line.

The volume of the measuring cylinder should be 1/50 of the metering pump rate in litres/h.
During this process, the suction line must not change its position.
NOTE The calibration of the metering pump is only valid for the currently set stroke length setting.
After changing the stroke length, the calibration must be performed again.

10.4.2.2 Calibration / Start


Fig. 10.56

to : The pump runs 122 strokes (ca. 1 min).


The strokes are counted down from 122 to 0.
NOTE By activating the 'Menu/Exit function, the running calibration can be interrupted.

to : After the running process, the amount removed from the measuring cylinder (see
chapter 10.4.2.1 Preparation) must be read off.
This quantity is then entered as the calibration value (in ml or l).

10.4.3 Calibration pump with oval gear meter (OGMPLUS)


If a dongle box and an oval gear meter are connected and the oval gear meter function
(see chapter 10.3.11) is activated, the oval gear meter pulse rate recorded is automatically
displayed at the end of the calibration process.
This is offset against the specified calibration value. A correlation thus occurs between the
oval gear meter pulses and the metered quantity.

417101442_KKS_E60.docx - 120 - Rev. 10-06.11


10.4.3.1 Preparation
Fig. 10.57

Connect the pump ready for operation


on the pressure side
(see chapter 7 Installing the device).
Fill a suitable measuring cylinder and
insert the suction line or suction and
return line.

The volume of the measuring cylinder should be 1/50 of the metering pump rate in litres/h.
During this process, the suction line must not change its position.
NOTE The calibration of the metering pump is only valid for the currently set stroke length setting.
After changing the stroke length, the calibration must be performed again.

10.4.3.2 Calibration / Start


Fig. 10.58

to : The pump runs 122 strokes (ca. 1 min).


The strokes are counted down from 122 to 0.
The oval gear meter pulses (OGM pulses) are counted upwards from 0.
By activating the 'Menu/Exit function, the running calibration can be interrupted.
NOTE If the OGM pulses are not displayed, check all the connections to the pump!

to : After the running process, the amount removed from the measuring cylinder
(see chapter 10.4.3.1 Preparation) must be read off.
This quantity is then entered as the calibration value (in ml or l).
Fig. 10.58

During the calibration process, the oval gear pulses


determined appear on the display.

417101442_KKS_E60.docx - 121 - Rev. 10-06.11


10.4.4 Calibration / Manual
If the calibration value to be entered is known, a dry calibration (immediate entry of the
value without a previous calibration process) can be conducted.
However, this method is not very accurate as no consideration is given to the on-site
conditions (back-pressure, viscosity, cable cross-chapters and lengths etc).
Fig. 10.60

10.4.4.1 Calibration data table


The pump capacity in l/h is allocated to the pumps electronics on the basis of the calibration
values entered in the table.
Example:
A specified value of 23.3 ml results in a pump capacity of 1.4 l/h.
NOTE These values relate to the metering medium of water at 20C

Pump capacity [l/h] Pump calibration value [ml]


Pump
at 50 (60) Hz at 50 (60) Hz
0,2 (0,24) 3,33 (4,00)
KKS

0,5 (0,6) 8,33 (10,0)


Fig. 10.61
0,9 (1,1) 15,0 (18,3)
1,4 (1,7) 23,3 (28,3)

10.5 Operating data


The following operating data is recorded and displayed under this menu item:
Operating hours
Litre
Amount of pulses

417101442_KKS_E60.docx - 122 - Rev. 10-06.11


10.5.1 Overview
Fig. 10.62

see chapter 10.5.2

see chapter 10.5.3

see chapter 10.5.4

10.5.2 Operating data / Operating hours


The pump running time (number of strokes 480 ms) since it was first commissioned or last
reset is displayed.

10.5.2.1 Selecting / Displaying / Deleting


Fig. 10.63

10.5.3 Operating data / Litre


The metered quantity in litres since the pump was first commissioned or last reset is
displayed. On operating the pump without an oval gear meter, this value is calculated
(ml/stroke number of metered strokes). If an oval gear meter is connected, the measured
quantity is displayed (determined from the number of oval gear meter pulses).

10.5.3.1 Selecting / Displaying / Deleting


Abb. 10.64

417101442_KKS_E60.docx - 123 - Rev. 10-06.11


10.5.4 Operating data / Amount of pulses
The number of pulses received via the pumps pulse input (plus II pins 3+4, see chapter
7.2.3 Plug II connection details) since it was first commissioned or last reset is displayed.

10.5.4.1 Selecting / Displaying / Deleting


Fig. 10.65

417101442_KKS_E60.docx - 124 - Rev. 10-06.11


11 Maintenance
Metering pumps must only be maintained by technically competent and authorized
CAUTION persons.
The maintenance interval is half-yearly. Shorter intervals are recommended in the event of
NOTE heavy loads (e.g. continuous use).

The following inspections are recommended:


suction pipes and pressure pipes for leak-free connections
suction valve and pressure valve (chapter 11.1, Fig. 11.1) for dirt and impermeability.
discharge connection (chapter 5, Fig. 5.1) on the pump head (for diaphragm breakage).
correct metering
union nut (chapter 7.1.2, Fig 7.6 and 7.1.3, Fig. 7.7)
metering head screws (chapter 11.2, Fig. 11.3, Pos. 2) (stable seat, 3 - 4 Nm)
The life of the diaphragm depends on the:
backpressure, operating temperature and metering medium.
NOTE It is recommended to inspect the diaphragm more frequently in extreme operating
conditions or if abrasive substances are metered.

11.1 Replacing the suction / return valve


Fig. 11.1
Pos. Description
CONNECTION SET
1 Union nut
A 2 Clamping piece
3 Tapered part
SUCTION-/RETURN VALVE
4 O-Ring, 10 x 2,5
B 5 Suction-/Return valve
6 O-Ring, 14 x 2,5
C ANGLE CONNECTION
PRESSURE VALVE
4 O-Ring, 10 x 2,5
6 O-Ring, 14 x 2,5
D Pressure valve (pressure line)
I Valve spring
7
II Valve-ball
III O-Ring, 12 x 1,5

Disassemble the suction valve and pressure valve (pos. 5/7) with a crescent wrench (SW 22).
Please observe, that the valve spring (pos. I), valve-ball (pos. II) and the o-ring (pos. III) are
NOTE not lost and installed in the right direction at the pressure valve.

Assemble all the O-rings.


Screw in the suction valve and pressure valve in the correct position (torque of 2-3 Nm)

417101442_KKS_E60.docx - 125 - Rev. 10-06.11


11.1.1 Inserting the metering valves in the correct positions
Fig. 11.2

On the suction valves and flow valves, the flow direction is


marked with an engraved arrow.
When inserting it, always ensure that the valves are inserted
according to the flow direction!

11.2 Replacing the diaphragm and pump head


Fig. 11.3

Pos. Description
1 Pump head
2 Metering head screw
3 Ceramics piston
4 Diaphragm unit
5 Bellows
6 Intermediate plate

Before opening pump head:


ATTENTION empty connecting lines,
rinse the pump head.
Loosen the metering head screws (pos. 2).
Take off the pump head (pos. 1) absolute straightly.
ATTENTION The ceramics cylinder can be destroyed when being set on edges!
Take ceramics piston (pos. 3) sideways out of the coupling of the diaphragm unit (pos. 4).
Un screw diaphragma unit (pos. 4).
Remove intermediate plate (pos. 6).
Exchange bellows (pos. 5).
Do not overdraw the diaphragm unit (pos. 4) when tightening, screw gently until stop.
The leakage connection of the intermediate plate (pos. 6) must be directed downwards.
Re-insert the piston (pos. 3).
Attach cylinder carefully on the pump head.
Hand-screw pump head screws
Screw-down cross-over pump head screws
NOTE Correct tightening torque: 3 to 4 Nm
Check metering head bolt tightening torque after 24 hours.
ATTENTION
Screw down the pump head absolute straight. Tighten the metering head evenly diagonally.

417101442_KKS_E60.docx - 126 - Rev. 10-06.11


11.3 Replacement of ceramics cylinder unit with piston
Procedure as described at chapter 11.2.
Fig. 11.4

Pos. Description
1 Ceramics cylinder unit
2 O-Ring, 22 x 2 (FPM)
3 O-Ring, 22 x 2 (EPDM)
4 Spring
5 O-Ring, 14 x 2,5
6 Valve nipple
7 Washer
8 Valve ball
9 O-Ring, 12 x 1,5

Unscrew the valve nipple (pos. 6).


Remove the washer (pos. 7), valve ball (pos. 8) and spring (pos. 4).
Unscrew the ceramics cylinder unit (pos. 1) in direction of diaphragm seat.
Insert a new unit. Replace the O-rings (pos. 2, 3, 5, 9)
Re-install valve nipple (pos. 6), balls (pos. 8) etc.

ATTENTION The ceramic cylinder may only be exchanged in connection with the ceramic piston.

11.4 Description of the stroke scale


Fig. 11.5 Fig. 11.6 Pos. Description
1 Stroke adjustment knob
2 Grub screws (2 x opposed)
3 Adjustment knob markings
4 Receiver for the adjustment knob (teethed)
5 Nonius scale
6 Metering connector
From factory-side the metering pump is set to
nominal pressure, in accordance with the
metering curves. If the stroke adjustment was
changed by the removal of the position button,
the basic position can be determined as
follows:
Switch-on metering pump.
Loosen 2 opposed grub screws (pos. 2).
Now the stroke adjustment knob (pos. 1)
can be removed from the subjacent tooth
system (pos. 4).
Turn the receiving part of the adjustment knob slowly to the left (pos 4) (counter clockwise), until
no medium flows out of the metering connector (pos. 6).
Slide up the adjustment knob (pos. 1) with the marking 0 (pos. 3), congruently on the marking
line of the nonius scale (pos. 5). The adjustment knob has to be slid on the tooth system until the
outer edge has reached the marking -0 (pos. 5) of the nonius scale.
Tighten again the grub screws (pos. 2).
The stroke setting has now been adjusted according to the special provisions.
NOTE To determine the metering capacity the pump ought to be engaged.

417101442_KKS_E60.docx - 127 - Rev. 10-06.11


12 Operating faults
12.1 Metering warning messages (display)
If external signals are no longer being processed and the output signals (empty, fault) are
switched off, the following error messages can be shown on the display of the metering
pump:
Display Meaning Effect Cause Remedy
Fig. 12.1
reserve report pump continues low-level advance
Refill the metering medium
(flashing) running warning active

Fig. 12.2
empty report pump is stopped empty report active Refill the metering medium

Fig. 12.3
Activate external enable or
metering lock
no external enable of the deactivate the metering
(only possible if this pump is stopped
pump lock in the configuration
is configured)
menu. (see chapter 10.3.7)
Indicator in
standard signal is under
Fig. 12.4 operation mode
3mA or cable to standard check the standard signal
4..20 mA flashes pump is stopped
signal connection is or cable
standard signal
broken
monitoring responds
Fig. 12.5 pump runs in
standard signal is standard signal exceeds
continuous reduce the standard signal
--.- above 23.0 mA
operation
the display range

12.2 Alarm messages (display)


Display Meaning Effect Cause Remedy
Fig. 12.6
alarm ! Motor is running
uncontrolled in
over dosage power electronic failure replace PC-Board
failure 1 continuous
permanent stroke
operation

Fig 12.7 backpressure too high reduce pressure


alarm ! Motor is not valve closed at pressure
open valve
running despite side
no metering
failure 2 of rotating Motor cool of the motor,
no stroke
dosing symbol. overheated/damaged or change
power electronic failure replace PC-board
Fig. 12.8 optical sensor polluted
motor in
alarm ! PC-board fault Send in pump
continuous
continuous metering Plug connection from control optical sensor
failure 3 operation
gear to PC-Board connection
motor control without request
interrupted
Fig. 12.9 error in tube fault check the tubes
alarm ! evaluating the diaphragm fault check the diaphragm
pump meters too
metering
failure 4 little or too much backpressure too high
monitoring or check the backpressure
oval gear meter
oval gear meter or too low

417101442_KKS_E60.docx - 128 - Rev. 10-06.11


12.2.1 Trouble shooting

Fault Possible cause Remedy

metering pump does not work, mains power cable damaged change mains power cable
no display indicator incorrect voltage check mains voltage
rinse the metering head through the
pump has no suction despite deposits, adhesions or drying-out
suction line, if necessary remove and
venting and max. strokes of the valves
clean or replace the valves
metering head is leaky, screw in the metering head fastening
metering head is loose
medium escapes from the screw diagonally
diaphragm breakage outlet diaphragm is torn replace the diaphragm

float of the suction pipe is jammed unjam the float

low-level indicator appears tighten the plug, clean the contacts,


suction pipe plug or strapping plug
on the display despite a full check whether the strapping plug is
is loose or not plugged in
container plugged in

suction pipe cable is faulty replace the empty report device

Prior to repair and maintenance work and metering of dangerous media, always rinse the
CAUTION metering head, relieve the pressure pipe and wear protective clothing (protective goggles,
gloves and apron).

Electronics repairs must only be performed by trained electricians, following the safety
regulations of the professional association VB G 4 and ZH 1/11)!
When opening the covers or removing parts, except when this is possible without tools,
CAUTION voltage-carrying parts may be exposed. Connection points may also be under live
voltages.

Before calibration, maintenance, repairs or replacement of parts, the device must be


disconnected from all voltage sources if it is necessary to open up the device.

417101442_KKS_E60.docx - 129 - Rev. 10-06.11


13 Wearing parts and spare parts (standard version)
13.1 Exploded view
Fig. 13.1

Pos Description type 00002 type 00005 type 00009 type 00014
Connection, angled PVDF G 3/8i hose 2/4 mm (ID/AD) 247613 --
1
Connection, angled PVDF G 3/8"i - hose 4/6 mm (ID/AD) -- 247620
2 Square nut 413226005
3 Headless screw 413401178
4 Stroke adjustment button 34070193
Pressure valve PVDF/FPM (Viton B), DRV PVFPKE004
247623 --
G3/8-G3/8-99 00002
Pressure valve PVDF/FPM (Viton B), DRV PVFPKE008
-- 247624 --
G3/8-G3/8-99 00005/00009
Pressure valve PVDF/FPM (Viton B), DRV PVFPKE008
-- 247630
G3/8-G3/8-99 00014
5
Pressure valve PVDF/EPDM, DRV PVEPKE004
247631 --
G3/8-G3/8-99 00002
Pressure valve PVDF/EPDM, DRV PVEPKE008
-- 247632 --
G3/8-G3/8-99 00005/00009
Pressure valve PVDF/EPDM, DRV PVEPKE008
-- 247633
G3/8-G3/8-99 00014
6 Washer 34070186
7 Adjustment nut 34070185
8 Cylinder piston unit complete 247607 247609 247605 247604
Suction-/Return valve, PVDF/FPM (Viton B),
248405
9 SDVPVFPKE000 G3/8-G3/8-99
Suction-/Return valve, PVDF/EPDM, SDVPVEPKE000 G3/8-G3/8-99 248406
Connection set 3/8 PVDF for hose 6/8, 6/10, 6/12 mm (ID/AD) 247629
10
Connection set 3/8" PVDF for double hose 6/10 mm (ID/AD) 247610
11 Pump head, PVDF 34070192
12 Coupling/Diaphragm unit complete 247601 247608 247602 247601
13 Intermediate plate 34070173
14 Protective Diaphragm (changing with pos. 12) 34760112
15 Bridge connector for empty signal-, pre-report 248186
16 Bridge connector pulse input 248187
17 Cover cap 34800117
18 Plug 4-pole (3-pole) empty signal-/pulse input 418463115
19 Plug 5-pole E 30/32 current-/pulse input 418463118
20 Plug 4-pole empty signal-/pulse output 418463117
21 Cover 34800120
22 Power cable 34860001

417101442_KKS_E60.docx - 130 - Rev. 10-06.11


13.2 Wearing part set
Consisting of 1 piece each:
- Suction valve, pre-delivery (Pos. 9)
- Pressure valve, return (Pos. 9)
- Pressure valve, pressure side (Pos. 5)
- Connecting kit for hose 4/6, 6/8, 6/12 mm (ID/AD), (Pos. 10)
- Diaphragms (Pos. 12)
- Supporting ring (Pos. 13)
- Protective Diaphragm (Pos. 14)
Description (Wearing part set EMP KKS) article-no.
00002 PVFPKE 247676
00005 PVFPKE 247677
00009 PVFPKE 247678
00014 PVFPKE 247679
00002 PVEPKE 247686
00005 PVEPKE 247687
00009 PVEPKE 247688
00014 PVEPKE 247689

1. Pump type (pump capacity)


00002 = 0,2 l/h
00005 = 0,5 l/h
00009 = 0,9 l/h
00014 = 1,4 l/h
2. Valve material
PV = PVDF
3. Sealing material
FP = Viton B
EP = EPDM
4. Valve ball material
KE = ceramics
Wearing part set EMP KKS 00014 PV FP KE

417101442_KKS_E60.docx - 131 - Rev. 10-06.11


14 Technical Specifications
14.1 Pump key
1. Electrical version

E 60 = (for explanation, see chapter 14.1.1)

2. Pump output 50 Hz (60 Hz)


00002 = 0,2 l/h (0,24 l/h)
00005 = 0,5 l/h (0,6 l/h)
00009 = 0,9 l/h (1,1 l/h)
00014 = 1,4 l/h (1,7 l/h)
3. Pump head material
PV = PVDF (standard)
4. Metering backpressure (not freely selectable)
10 = 10 bar s (8 bar)
5. Gasket material
FP = Viton B (standard)
EP = EPDM
KA = Kalrez
6. Ball material
KE = Ceramic (standard)
GL = Glas
7. Valve material
PV = PVDF (standard)
8. Valve spring
99 = without spring (standard)
9. Mains power supply
17 = mains power cable 2 m
appliance and grounding type
plug (E60, 230 V) (standard)
21 = mains power cable 2 m
appliance plug and cable end sleeves
(E60, 115 V)
10. Voltage/frequency
01 = 115V / 50 Hz
02 = 115V / 60 Hz
E60 00009 PV 10 FP KE PV 99 17 03 03 = 230V / 50 Hz (standard)
04 = 230V / 60 Hz

Other specifications provided on request!

417101442_KKS_E60.docx - 132 - Rev. 10-06.11


Pump key 2
11.Connection pre-delivery
04 = set for PE hose 6/8
05 = set for PVC hose 6/10
06 = set for PVC-fabric 6/12
33 = set for hose 6/8, 6/10, 6/12 (standard)
12. Connection pressure side
31 = set bent for PE/PTFE hose 2/4
(standard for 0,2 l/h)
32 = set bent for PE/PTFE hose 4/6
(standard for 0,5 - 1,4 l/h)
34 = set bent for hose 2/4, 4/6
13. Connection material
99 = PVDF
14. Electrical stroke adjustment
99 = without electrical stroke adjustment
15. Diaphragm failure detection
99 = without diaphragm failure detection
16. Housing version
01 = standard housing

33 32 99 99 99 01

Example of a complete pump code of a standard pump:

E 10 00 0 09 PV 10 FP KE PV 99 17 03 - 33 32 99 99 99 01
( Pump code 1 ) ( Pump code 2 )

417101442_KKS_E60.docx - 133 - Rev. 10-06.11


14.1.1 Pump key definition E60
Electrical version
E60 On/Off switch for switching the pump
mechanical stroke adjustment
backlit graphical display, 4 control keys
individual stroke control (each stroke is executed completely)
metering control via stroke signal output (computed)
or via external metering monitoring system
collection of operating and consumption data (computed)
calibration function
configurable operation modes:
Internal operation
Setting of metering quantity/metering frequency in:
Strokes/min.
Percentage
Litres/hr (or gallons/hr)
External operation
Pulse operation (control via pulses)
- Pulse multiplication (1 incoming pulse = n metering strokes)
- Pulse division (n incoming pulses = 1 metering stroke)
Standard signal operation (control via external standard signal 0/4 - 20 mA or 20 - 0/4 mA)
Batch operation (a preset quantity is metered after being triggered by external enable pulse)
Inputs:
low-level monitoring of bundle holder (reserve and empty report)
pulse
standard signal
enabling signal (metering lock)
metering monitoring
Outputs:
low-level monitoring of bundle holder / fault (reserve and empty report)
Fault report
stroke signal
E60PLUS similar
PLUS
to E 60, but with the addition of a dongle box for connecting of oval gear meter OGM
(expansion unit for the capture of operating data)
display of the currently measured metering quantity and automatic readjustment of pump output
(only in conjunction with an external through flow monitoring system,
e.g. oval gear meter OGMPLUS)
automatic calibration function via oval gear meter
consumption data monitoring via oval gear meter

417101442_KKS_E60.docx - 134 - Rev. 10-06.11


14.2 Dimensions
Fig. 14.1

417101442_KKS_E60.docx - 135 - Rev. 10-06.11


14.3 Technical specifications "Overview tables"
14.3.1 General data
Pump type
Description
00002 00005 00009 00014
Supply voltage 230 V / 50/60 Hz 10 %
(special voltages on request)
max. power consumption IN 115V 50/60 Hz 0,2 A / 0,21 A
230V 50/60 Hz 0,09 A
Motor power 115V 50/60 Hz
18,7 / 19,8 W
230V 50/60 Hz
Fuse rating 315 mA
Type of protection IP 65
Breaking capacity at circuit with 24 V
Empty report output 24 V 3 A AC/DC
stroke signal output 24 V 0,3 A DC
Breaking capacity at circuit with 230 V
Empty report output 230 V / 3 A AC/DC
stroke signal output connection according to VDE is not permitted

14.3.2 General data


Pump type
Description
00002 00005 00009 00014
Pump output [l/h]*/** 0,2 0,5 0,9 1,4
max. metering backpressure [bar] 10
Piston diameter [mm] 3 4,766,34 8
Number of strokes [1/min] at 50 Hz 122
Metering quantity/stroke [cm] 50 Hz/60 Hz 0,027/0,032 0,068/0,082 0,12/0,44 0,19/0,23
exactness of reproduction [see chapter 14.6] < 3%
max. conveyable viscosity [mPas] 200
Permitted ambient temperature 5-40C
Suction height [mWs] at 100 % stroke*** 2
max. pre-pressure (suction side) [bar] 0,3
Noise level (DBA) in 1 m distance
54,0
(according to DIN EN 12639/ EN ISO 9614-2)
Hose connectors
6/8, 6/10, 6/12
Suction-/Return line [ID mm]
Hose connectors
2/4 4/6
Pressure(metering)line [ID mm]
Weight [kg] 2,4
* all data relate to water at 20 C
** At a mains power frequency of 60 Hz, the delivery capacity increases by 20%, while the metering backpressure decreases
by 20%.
*** Suction heights with clean, moistened valves at 100% metering stroke and max. stroke frequency

417101442_KKS_E60.docx - 136 - Rev. 10-06.11


14.3.3 In-/ and output circuit
14.3.3.1 Connector I
Fig. 14.2
input allocation external circuit declaration of value
empty report 1 (brown)
+
voltage-free contact
4 (black)
3 (blue) Note: do not connect
reserve
+ any external voltages!
4 (black)

14.3.3.2 Connector II
Fig. 14.3
input allocation external circuit declaration of value
pulse 2 (white) minimum power-on and power-off time
+ 15ms
voltage-free contact
4 (black)
5 (grey) Note: do not connect
metering lock/ batch/
+ any external voltages!
metering monitoring
4 (black)
standard signal external current 0/4-20 mA, load approx. 50 ohms
3 (blue)
+ Note: Observe the
4 (black) polarity of the
connected signal!
output allocation external circuit declaration of value
external 1 (brown) voltage-free contact Power supply for ext. devices
power supply + Outputs: 5VDC; max. 50mA
Note: do not connect
4 (black) any external voltages!

14.3.3.3 Connector III


Fig. 14.4
output allocation external circuit declaration of value
max. external voltage 230 VAC/DC
1 (brown) max. 3 A
empty/reserve/fault + with reserve report:
external current
report contact approx. 500 ms closed
2 (white)
contact approx. 500 ms opened
max. external voltage 24 V DC,
max 0,3 A
when stationary: Contact open
at 50 Hz mains power:
at 100 % run:
contact approx. 310 ms closed
contact approx. 180 ms opened
external current at 50 % run:
3 (blue)
stroke signal + Note: Observe the contact approx. 310 ms closed
4 (black) polarity of the contact approx. 660 ms opened
connected signal!
at 60 Hz mains power:
at 100 % run:
contact approx. 260 ms closed
contact approx. 150 ms opened
at 50 % run:
contact approx. 260 ms closed
contact approx. 550 ms opened

417101442_KKS_E60.docx - 137 - Rev. 10-06.11


14.4 Materials
Pump-head: PVDF
Metering-piston/-cylinder: Ceramic
Diaphragms: PTFE-EPDM composite
Seals: FPM (Viton B), optionally EPDM
Valves: PVDF
Valve-balls: Ceramics
O-ring: FPM, optionally EPDM
Valve-springs: Hastelloy C4/C22 PTFE coated
Housing: thermoplastic polyester
Colour: blue, RAL 5007
Special versions available on request.

14.5 Connector assignments / Control input and output


14.5.1 Pin assignment / conductor coloring Connector I (3-terminal)
Connector for low-level advance warning or empty report
Fig. 14.5 Conductor coloring Assignment
Pos (cable connection)
1 brown low-level advance warning
3 blue empty report
4 black GND
see also chapter: 7.2.2
In the event that the empty report is not used, contact 3/4 must always be bridged! The
WARNING protective cap provided for this (see chapter 7.2.1) creates the bridge between he contacts
and must be attached in this case.
The empty and reserve report input can be inverted in the "Configuration / Low-level
NOTE contact" menu. (see chapter 10.3.8)

14.5.2 Pin assignment / conductor coloring Connector II (5-terminal)


Connector for pulse / standard signal input and metering lock
Fig. 14.6 Conductor coloring Assignment
Pos (cable connection)
1 brown Output 5 V, DC
2 white Pulse input
3 blue Input metering lock
4 black GND
5 grey Input standard signal 0/4 20 mA
see also chapter 7.2.3
The metering lock input is only active if it has been previously set in "Configuration /
NOTE metering lock" menu. (see chapter 10.3.7). The batch function (see chapter 10.3.15) and
metering monitoring (see chapter 10.3.13) must also be configured.

14.5.3 Pin assignment / conductor coloring Connector III (4-terminal)


Connector for empty report, fault and stroke signal output:
Fig. 14.7 Conductor coloring Assignment
Pos (cable connection)
1 brown Output low level warning, empty report, fault (+)
2 white Output low level warning, empty report, fault (-)
3 blue Output stroke signal (+)
4 black Output stroke signal (-)
see also chapter 7.2.4
At 115V/230 V, a simultaneous connection of contact 1+2 (alarm output) and 3+4
WARNING (stroke signal output) is generally not permitted.

417101442_KKS_E60.docx - 138 - Rev. 10-06.11


14.6 Metering rates
Repeatable metering accuracy is approx. 3 % at minimum 30 % stroke length and
otherwise constant conditions. In order to balance the clearance, the stroke length adjustment
has to be based on the lower value towards the desired stroke length (= sense of rotation to the
right).
Due to the characteristics of the pump, higher output can be produced until the operating
temperature is reached.
Precise metering can be achieved provided the following items are adhered to:
a) All metering-rate data is referred to measurements using water at 20 C, constant
supply voltage and the metering pump at operating temperature.
b) A pressure-maintenance valve (or metering valve) for generation of the most constant
possible counter pressure of not less than 0.5 bar should be used in order to obtain
high metering accuracy in case of metering with unobstructed discharge.
c) If there is pre-pressure on the suction side, the pressure difference between the suction
and the pressure sides must be at least 1 bar. The water column on the metering pump
must be protected by an appropriate valve arrangement.
A pressure control valve or a metering value is not an absolutely hermetically sealing
NOTE shutoff device.

Metering stroke adjustment may only be performed with the pump running if the stroke
WARNING adjusting screw is released.

14.7 Delivery capacity in relation to the back pressure


Setting accuracy + 15 % - 5 % of the nominal value; all data relate to water at 20 C and
comply with the notes in the operating instructions.
NOTE The tender specifications are shown at a pump frequency of 50 Hz.
Fig. 14.8
1.6
]

1.5
g [

1.4

1.3

1.2

1.1
Delivery capacity (l/h)
]

1
[

0.9

0.8
g

0.7

0.6

0.5
]

0.4
[

0.3

0.2

0.1

0
1 2 3 4 5 6 7 8 9 10

Back pressure (bar)

417101442_KKS_E60.docx - 139 - Rev. 10-06.11


14.7.1 Delivery capacity in relation to the stroke length
Setting accuracy + 15 % - 5 % of the nominal value; all data relate to water at 20 C and
comply with the notes in the operating instructions.
NOTE The tender specifications are shown at a pump frequency of 50 Hz.
Fig. 14.9
1.6

1.5

1.4

1.3

1.2
2 bar2 bar
Typ 014
Typ 014
1.1
Delivery capacity (l/h)

0.9 10 bar
10 bar Typ 014
Typ 014

0.8

0.7 2 bar2 bar


Typ 009
Typ 009

0.6
1010 bar
bar TypTyp
009 009
0.5

0.4 2 bar2 bar


TypTyp 005
005

0.3 1010 bar


bar TypTyp
005 005
0.2 2 barTyp
2 bar Typ 002
002
0.1
10 bar
10 bar TypTyp
002 002
0
0 10 20 30 40 50 60 70 80 90 100

Stroke-length adjustment (%)

417101442_KKS_E60.docx - 140 - Rev. 10-06.11


15 Declaration of Conformity

417101442_KKS_E60.docx - 141 - Rev. 10-06.11


Sommaire

1 Gnralits ...................................................................................................................................... 145


1.1 Etendue de la garantie...........................................................................................................................................................145
1.2 Adresse de contact / Fabricant ..............................................................................................................................................145
2 Scurit ............................................................................................................................................ 146
2.1 Instructions de scurit .....................................................................................................................................................146
2.2 Passages mis en vidence ...............................................................................................................................................146
2.3 Enumrations......................................................................................................................................................................146
2.4 Instructions de scurit spciales lors des travaux de maintenance et de rparation .............................................146
3 Contenu de la livraison ................................................................................................................ 147
PLUS
3.1 Accessoires pour la conversion sur le modle EMP KKS E60 .............................................................................147
4 Description du fonctionnement ................................................................................................. 148
4.1 Fonctions mcaniques.......................................................................................................................................................148
4.2 Fonctions lectroniques ....................................................................................................................................................148
4.2.1 Modes de service ..................................................................................................................................................................148
PLUS
4.3 Fonctions lectroniques supplmentaires dans l EMP KKS E60 ........................................................................148
5 Structure .......................................................................................................................................... 149
5.1 EMP KKS E60 ....................................................................................................................................................................149
PLUS
5.2 EMP KKS E60 .............................................................................................................................................................149
5.3 Afficheurs / Elments de commande / Prises de connexion ........................................................................................149
5.3.1 Modles EMP KKS E60 et EMP KKS E60PLUS........................................................................................................................149
5.3.2 Prises de connexion du module de protection sous botier ( Dongle-Box ) .........................................................................149
6 Montage ........................................................................................................................................... 150
6.1 Schma de montage..........................................................................................................................................................150
7 Installation de lappareil .............................................................................................................. 151
7.1 Installation hydraulique......................................................................................................................................................151
7.1.1 Exemples dinstallation ..........................................................................................................................................................151
7.1.2 Raccordemnt de la conduite daspiration et de la conduite de pression..................................................................................152
7.1.3 Raccord de la conduite de dosage .........................................................................................................................................153
7.2 Installation dlectrique ......................................................................................................................................................153
7.2.1 Entres et sorties ...................................................................................................................................................................153
7.2.2 Affectation des connexions - emplacement enfichable I ( 3 broches) entre du pr-avertissement de niveau et de la
signalisation de ltat vide ......................................................................................................................................................154
7.2.2.1 Installation de la lance daspiration avec pr-avertissement de niveau et signalisation dtat vide........................................................................ 154
7.2.3 Affectation des connexions - emplacement enfichable II ( 5 broches) entre du signal dimpulsion, du signal normalis, du
blocage du dosage, de la charge et de la surveillance du dosage ..........................................................................................155
7.2.3.1 Installation de la commande dimpulsion (compteur deau)..................................................................................................................................... 155
7.2.3.2 Installation de la commande du signal normalis .................................................................................................................................................... 155
7.2.3.3 Installation de la commande via le blocage du dosage ........................................................................................................................................... 156
7.2.3.4 Installation de la fonction de charge ........................................................................................................................................................................ 156
7.2.3.5 Installation de la surveillance du dosage ................................................................................................................................................................. 157
7.2.4 Affectation des connexions - emplacement enfichable III ( 4 broches) - sortie de lalarme et du signal de course ................ 158
7.2.4.1 Installation de la sortie niveau et dfaut respectivement ............................................................................................................... 158
7.2.4.2 Installation de la sortie du signal de course pour 24 V / DC ......................................................................................................... 158
7.2.4.3 Conversion du matriel pour le contact dalarme .............................................................................................................................. 159
7.2.4.3.1 Avec le rglage de configuration - sortie dalarme ON 159
7.2.4.3.2 Avec le rglage de configuration sortie dalarme OFF 159
7.2.5 Affectation des connexions - emplacement enfichable IV, connexion au rseau ....................................................................159
PLUS
8 Conversion de l EMP KKS E60 sur l EMP KKS E60 .................................................... 160
8.1 Montage du module de protection sous botier (Dongle-Box) .....................................................................................160
8.2 Affectation des connexions des emplacements enfichables........................................................................................161
8.2.1 Affectation des connexions - emplacement enfichable V ( 5 broches), entre du compteur roues ovales ..........................161
8.2.1.1 Installation du compteur roues ovales (OGM ou OGMPLUS) ................................................................................................................................. 161
8.2.2 Affectation des connexions - emplacement enfichable VII ( 5 broches) entre de limpulsion de charge et du blocage du
dosage ..................................................................................................................................................................................162
8.2.2.1 Installation pour limpulsion de charge ..................................................................................................................................................................... 162
8.2.2.2 Installation du blocage du dosage............................................................................................................................................................................ 163
8.2.3 Affectation des connexions - emplacement enfichable VIII ( 5 broches) entre dimpulsion, du signal normalis et du blocage
du dosage..............................................................................................................................................................................163
8.2.3.1 Installation de la commande dimpulsion (compteur deau)..................................................................................................................................... 163
8.2.3.2 Installation du signal normalis (mA) ....................................................................................................................................................................... 164
8.2.3.3 Installation du blocage du dosage............................................................................................................................................................................ 164
9 Mise en service .............................................................................................................................. 165
9.1 Mise en marche de la pompe ...........................................................................................................................................165
9.2 Arrt de la pompe...............................................................................................................................................................165
9.3 Fonctions des touches.......................................................................................................................................................165
9.4 Symboles Affichs..............................................................................................................................................................165
9.5 Premire mise en service / Etat la livraison ................................................................................................................166
9.5.1 Affichage de la version du logiciel ..........................................................................................................................................166
9.5.2 Affichage dans le niveau de fonctionnement ..........................................................................................................................166
9.5.3 Configuration .........................................................................................................................................................................166

417101442_KKS_E60.docx - 142 - Rev. 10-06.11


10 Description des menus ................................................................................................................ 167
10.1 Menu principal ....................................................................................................................................................................167
10.1.1 Vue densemble .....................................................................................................................................................................167
10.2 Mode opration...................................................................................................................................................................168
10.2.1 Slectionner ..........................................................................................................................................................................168
10.2.2 Mode opration / Interne ........................................................................................................................................................168
10.2.2.1 Slectionner.............................................................................................................................................................................................................. 168
10.2.2.2 Affichage lcran dans lindicateur de progression de lappel / rglage................................................................................................................ 169
10.2.3 Mode opration / Impulsions ..................................................................................................................................................169
10.2.3.1 Slectionner.............................................................................................................................................................................................................. 170
10.2.3.2 Affichage lcran dans lindicateur de progression de lappel / rglage................................................................................................................ 170
10.2.4 Mode opration / Courant (signal normalis externe) .............................................................................................................171
10.2.4.1 Slectionner.............................................................................................................................................................................................................. 171
10.2.4.1.1 Rglage mode opration / courant / choix par oprateur 172
10.2.4.2 Affichage dans lindicateur de progression de lappel.............................................................................................................................................. 172
10.3 Configuration.......................................................................................................................................................................172
10.3.1 Vue densemble .....................................................................................................................................................................172
10.3.2 Dfilement de lafficheur ...................................................................................................................................................173
10.3.3 Configuration / Langue ..........................................................................................................................................................173
10.3.3.1 Slectionner.............................................................................................................................................................................................................. 173
10.3.4 Configuration / Unit ..............................................................................................................................................................173
10.3.4.1 Slectionner.............................................................................................................................................................................................................. 173
10.3.5 Configuration / Code ..............................................................................................................................................................174
10.3.5.1 Slectionner.............................................................................................................................................................................................................. 174
10.3.5.2 Rglage .................................................................................................................................................................................................................... 174
10.3.6 Configuration / Dmarrage auto .............................................................................................................................................174
10.3.6.1 Slectionner.............................................................................................................................................................................................................. 175
10.3.7 Configuration / Blocage du dosage ........................................................................................................................................175
10.3.7.1 Slectionner.............................................................................................................................................................................................................. 175
10.3.8 Configuration / Commutateur dniveau ...................................................................................................................................175
10.3.8.1 Slectionner.............................................................................................................................................................................................................. 176
10.3.9 Configuration / Alarme ...........................................................................................................................................................176
10.3.9.1 Slectionner.............................................................................................................................................................................................................. 176
10.3.9.2 Rglage du fonctionnement du contact du relais dalarme ...................................................................................................................................... 176
10.3.10 Configuration / Mmoire dimpulsions ....................................................................................................................................177
10.3.10.1 Slectionner.............................................................................................................................................................................................................. 177
10.3.10.2 Affichage dans lindicateur de progression de lappel lorsque la mmoire dimpulsions est active ...................................................................... 177
10.3.11 Configuration / Compteur roues ovales (justement E60PLUS & OGM or OGM PLUS) ...............................................................178
10.3.11.1 Slectionner.............................................................................................................................................................................................................. 178
10.3.12 Configuration / Rglage du dosage (justement E60PLUS & OGMPLUS) ......................................................................................178
10.3.12.1 Slectionner.............................................................................................................................................................................................................. 179
10.3.12.2 Affichage dans lindicateur de progression de lappel lorsque le rgulateur de dosage est activ ......................................................................... 179
10.3.13 Configuration / Contrle du dosage........................................................................................................................................179
10.3.13.1 Slectionner.............................................................................................................................................................................................................. 180
10.3.13.2 Contrle du dosage / Arrt pompe ........................................................................................................................................................................... 180
10.3.13.3 Contrle du dosage / Courses ................................................................................................................................................................................. 180
10.3.13.4 Contrle du dosage / cart (justement E60PLUS & OGM ou OGMPLUS).................................................................................................................... 181
10.3.13.5 Contrle du dosage / Entre blocage dosage (seulement pour E60 SANS Dongle-Box) ...................................................................................... 181
10.3.13.6 Affichage des impulsions du compteur roue ovale (seulement pour E60PLUS) ..................................................................................................... 182
10.3.14 Configuration / MicroFlowPLUS ................................................................................................................................................182
10.3.14.1 Slectionner.............................................................................................................................................................................................................. 182
10.3.14.2 MicroFlowPLUS / Arrt pompe .................................................................................................................................................................................... 183
10.3.14.3 MicroFlowPLUS / Courses .......................................................................................................................................................................................... 183
10.3.14.4 MicroFlowPLUS / cart................................................................................................................................................................................................ 183
10.3.14.5 MicroFlowPLUS / Pause de dosage ............................................................................................................................................................................ 184
10.3.14.6 MicroFlowPLUS / Retard de dosage ........................................................................................................................................................................... 184
10.3.14.7 MicroFlowPLUS / talonnage...................................................................................................................................................................................... 185
10.3.15 Configuration / Charge ...........................................................................................................................................................185
10.3.15.1 Slectionner.............................................................................................................................................................................................................. 186
10.3.15.2 Charge / Quantit ..................................................................................................................................................................................................... 186
10.3.15.3 Charge / Entre (seulement pour E60 SANS Dongle-Box) ..................................................................................................................................... 187
10.3.15.4 Affichage dans lindicateur de progression de lappel.............................................................................................................................................. 187
10.3.16 Configuration DegasPLUS ........................................................................................................................................................187
10.3.16.1 Slectionner.............................................................................................................................................................................................................. 188
10.3.16.2 Degas / Degas courses ............................................................................................................................................................................................ 188
10.3.16.3 Degas / Degas pause ............................................................................................................................................................................................... 189
10.4 talonnage ..........................................................................................................................................................................189
10.4.1 Vue densemble .....................................................................................................................................................................189
10.4.2 talonnage / pompe...............................................................................................................................................................190
10.4.2.1 Prparation ............................................................................................................................................................................................................... 190
10.4.2.2 talonnage / Dmarrage .......................................................................................................................................................................................... 190
10.4.3 talonnage / pompe avec compteur roues ovales (OGMPLUS) .............................................................................................190
10.4.3.1 Prparation ............................................................................................................................................................................................................... 191
10.4.3.2 talonnage / Dmarrage .......................................................................................................................................................................................... 191
10.4.4 talonnage / Manuell .............................................................................................................................................................192
10.4.4.1 Tableau des donnes de calibrage .......................................................................................................................................................................... 192
10.5 Dones dopration ............................................................................................................................................................192
10.5.1 Vue densemble .....................................................................................................................................................................193
10.5.2 Dones dopration / Heures dopration ...............................................................................................................................193
10.5.2.1 Slectionner / afficher / annuler ............................................................................................................................................................................... 193
10.5.3 Dones dopration / Litres ....................................................................................................................................................193
10.5.3.1 Slectionner / afficher / annuler ............................................................................................................................................................................... 193
10.5.4 Dones dopration / Nombre dimpulsions ............................................................................................................................194
10.5.4.1 Slectionner / afficher / annuler ............................................................................................................................................................................... 194

417101442_KKS_E60.docx - 143 - Rev. 10-06.11


11 Maintenance .................................................................................................................................... 195
11.1 Remplacement de la soupape daspiration/ soupape de retour ..................................................................................195
11.1.1 Montage des soupapes de dosage dans la position correcte .................................................................................................196
11.2 Remplacement de la membrane et de la tte de pompe .............................................................................................196
11.3 Remplacement du cylindre cramique avec piston.......................................................................................................197
11.4 Ajustement du dispositif de rglage de course mcanique..........................................................................................197
12 Dfauts de service ........................................................................................................................ 198
12.1 Message davertissement - Dosage (afficheur) .............................................................................................................198
12.2 Messages derreur (afficheur) ..........................................................................................................................................198
12.2.1 Tableau derreurs ..................................................................................................................................................................199
13 Pices dusure et pices dtaches (modle standard) ..................................................... 200
13.1 Vue clate .........................................................................................................................................................................200
13.2 Kit de pices d'usure .........................................................................................................................................................201
14 Donnes techniques ..................................................................................................................... 202
14.1 Codes de pompe ................................................................................................................................................................202
14.1.1 Dfinition du code de pompe E60 ..........................................................................................................................................204
14.2 Dimensions .........................................................................................................................................................................205
14.3 Donnes techniques Tableau de vue densemble ..................................................................................................206
14.3.1 Donnes gnrales................................................................................................................................................................206
14.3.2 Dones gnerals..................................................................................................................................................................206
14.3.3 Montage dentre / Montage dsorties ....................................................................................................................................207
14.3.3.1 Douille fiche I ......................................................................................................................................................................................................... 207
14.3.3.2 Douille fiche II ........................................................................................................................................................................................................ 207
14.3.3.3 Douille fiche III ....................................................................................................................................................................................................... 207
14.4 Matriau ...............................................................................................................................................................................208
14.5 Affectation des broches des connecteurs.......................................................................................................................208
14.5.1 Brochage et couleurs des fils du connecteur I (3 broches) .....................................................................................................208
14.5.2 Brochage et couleurs des fils du connecteur II (5 broches) ....................................................................................................208
14.5.3 Brochage et couleurs des fils du connecteur III (4 broches) ...................................................................................................208
14.6 Performances de dosage ..................................................................................................................................................209
14.7 Dbit estim en fonction de la contre-pression..............................................................................................................209
14.8 Dbit estim en fonction du rglage de dosage ............................................................................................................210
15 Dclaration de conformit .......................................................................................................... 211

417101442_KKS_E60.docx - 144 - Rev. 10-06.11


1 Gnralits
Ce manuel technique contient toutes les instructions concernant linstallation et la mise en
service ainsi que les travaux de maintenance et de rparation sur la pompe doseuse
membrane des sries ELADOS EMP KKS E60 et ELADOS EMP KKS E60PLUS.

IMPORTANT
Lors de lutilisation de ce mode demploi, veuillez tenir compte de la version du
logiciel de votre pompe (voir chapitre 9.5.1).
Les chapitres en allemand de ce guide constituent la VERSION ORIGINALE DE LA
NOTICE DUTILISATION, juridiquement pertinente.
INDICATION Toutes les autres langues sont des traductions de la VERSION ORIGINALE DE LA
NOTICE DUTILISATION.

Il est impratif dobserver dans tous les cas les avis de scurit et les remarques mises
en vidence !

1.1 Etendue de la garantie


Le fabricant reconnatra un cas de garantie comme tel, en ce qui concerne la scurit de
service, la fiabilit et la performance de lappareil de dosage, uniquement dans les conditions
suivantes :
le montage, le raccordement, le rglage, la maintenance et les rparations sont excuts
par un personnel spcialis, form et agr,
la pompe doseuse membrane est utilise conformment aux instructions figurant dans le
mode demploi appartenant la livraison,
seules des pices dtaches originales sont utilises lors des rparations,
louverture du carter de pompe entrane lannulation de toute revendication de garantie.
Par ailleurs, seront valables les conditions gnrales de garantie et de prestations de la
socit ECOLAB Engineering GmbH.

1.2 Adresse de contact / Fabricant

ECOLAB Engineering GmbH


Raiffeisenstrae 7
D-83313 Siegsdorf
Tlphone : (+49) 86 62 / 61 0
Tlcopie : (+49) 86 62 / 61 2 35
eMail: engineering-mailbox@ecolab.com

417101442_KKS_E60.docx - 145 - Rev. 10-06.11


2 Scurit
2.1 Instructions de scurit
Les travaux de raccordement et de rparation sur la pompe doseuse membrane doivent
tre excuts uniquement par un personnel spcialis et agr.
Dbrancher absolument la fiche secteur avant deffectuer des travaux sur les pices
lectriques, quelle que soit leur nature.
Il faut porter des vtements de protection appropris lors des travaux de maintenance
et de rparation.
Il est impratif de toujours observer les consignes de scurit concernant la manipulation
des produits chimiques.

2.2 Passages mis en vidence


Dans cette notice technique, les passages mis en vidence par les expressions
PRECAUTION, ATTENTION, IMPORTANT et REMARQUE ont la signification suivante :
est utilis si le fait de ne pas respecter la lettre les instructions dutilisation, les
PRECAUTION instructions de travail et les droulements de travail prescrits, ou autres, (ou de ne
pas les respecter du tout) peut provoquer des blessures ou des accidents.
est utilis si le fait de ne pas respecter la lettre les instructions dutilisation, les
ATTENTION instructions de travail et les droulements de travail prescrits, ou autres, (ou de ne pas
les respecter du tout) peut provoquer un endommagement de lappareil.

IMPORTANT
est utilis sil faut prter une attention particulire lors de la manipulation de
lappareil.

REMARQUE est utilis sil faut prter une attention une particularit.

2.3 Enumrations
Les numrations mise en vidence par ce symbole () dcrivent une activit qui doit
tre ralise par le monteur ou par lutilisateur.

2.4 Instructions de scurit spciales lors des travaux de maintenance


et de rparation
Avant de procder aux travaux de maintenance et de rparation, ainsi quau dosage de
matires dangereuses, il faut toujours rincer la tte de dosage,
dcharger la conduite de pression et porter des vtements de protection (lunettes de
protection, gants de protection et tablier).
Seuls des lectriciens spcialiss sont autoriss excuter des rparations de nature
PRECAUTION lectrique (observer les rgles de scurit de la caisse de prvoyance daccidents
VB G 4 et ZH 1/11) !
Des composants qui conduisent la tension, peuvent tre dgags lorsque des
couvercles sont ouverts ou lorsque des pices sont retires, sauf si cela est possible
sans outil.
Des lments de raccordement peuvent aussi conduire la tension.

IMPORTANT Utiliser uniquement des pices dtaches originales lors des rparations.

417101442_KKS_E60.docx - 146 - Rev. 10-06.11


3 Contenu de la livraison
La livraison comprend les lments suivants :
Fig. 3.1 Pompe doseuse, modle EMP KKS E60
y compris le cble de branchement
au rseau (2 m) avec connecteur
contacts de protection et connecteur
borgne pour les entres et les sorties.

Fig. 3.2 Fiche de connexion 5 broches pour


lentre des impulsions ou des signaux
normaliss.

Fig. 3.3 Elments de connexion


(pour tuyaux flexibles 4/6, 6/8, 6/12
(ID/AD) mm).

Schma de montage pour les raccords de


tuyaux (notice annexe).
Plan daffectation des broches des
connecteurs (notice annexe).
Fig. 3.4 Manuel dinstructions succinct
(art. n 417101795)
CD Notice technique
(art. n 417101793)

3.1 Accessoires pour la conversion sur le modle EMP KKS E60PLUS


Fig. 3.5 Module de protection sous botier
(Dongle-Box) (art. n 248606)

417101442_KKS_E60.docx - 147 - Rev. 10-06.11


4 Description du fonctionnement
4.1 Fonctions mcaniques
Les pompes doseuses de la srie ELADOS EMP KKS sont des pompes lectromotrices
membrane et piston avec refoulement anticip.
La membrane sert au pr-dbitage et le piston sert au dosage. En raison du retour
permanent de lexcdent, cette pompe doseuse fonctionne de manire se purger
automatiquement.
La pompe doseuse convient lutilisation de substances doses propres et non abrasives
dont la viscosit ne dpasse pas 200 mPas (mthode de mesure: Brookfield).
La pompe doseuse est entrane par un moteur synchrone et un excentrique bielle.
Fig. 4.1 Au moment o la membrane (pos. 1) se dplace en
direction engrenage, le fluide de dosage est aspir a
travers la soupape (pos. 2). Simultanment, dans la
chambre de compression du cylindre du piston dosage
(pos. 3) se forme un vacuum; le fluide de dosage, refoul
davance, scoule dans cet espace ds que lalsage
(pos. 4) est desserr.
Le dosage est effectu durant le mouvement de pression,
travers la soupape (pos. 5). Le fluide de dosage
excdentaire reflue a travers la soupape de retour (pos. 6)
dans le rservoir. Avec le bouton de rglage de course
(pos. 7), le dbit peut tre ajust pendant le
fonctionnement (de 0 100 %). Ceci change la profondeur
dimmersion du cylindre; le volume de refoulement anticip
reste constant.
Il est vivement recommand dutiliser une lance daspiration munie dun dispositif de
signalisation de ltat vide et dun collecteur de salets appartenant notre programme
ATTENTION daccessoires afin de protger linstallation de dosage ! Le dispositif de signalisation de
ltat vide met la pompe hors service ds que le niveau natteint plus une certaine valeur
(dans le rservoir).

4.2 Fonctions lectroniques


La pompe est manie au moyen de 4 touches (fig. 5.5, pos. 2, 3, 4 et 5)
(voir au chapitre 9.3 Fonctions des touches ).
Laffichage de service est reprsent via un afficheur graphique (fig. 5.5, pos. 6).

4.2.1 Modes de service


La pompe peut tre utilise dans trois modes de service :
INTERNE fonction de dosage manuelle (rglage dusine)
EXTERNE commande dimpulsion
EXTERNE commande de signal normalis (mA)
Il est en outre possible, dans la rubrique Configuration, de programmer un dosage par
charges (pour chaque impulsion de dmarrage, une quantit dtermine est dose).

4.3 Fonctions lectroniques supplmentaires dans l EMP KKS E60PLUS


Compteur roues ovales branchement / Compteur roues ovales - valuation
Rgulation du dosage laide dun compteur roues ovales OGMPLUS
Possibilit dun calibrage automatique avec un compteur roues ovales OGMPLUS
Sparation des entres Blocage du dosage / Surveillance du dosage / Compteur
roues ovales sur plusieurs raccords pour simplifier les connexions externes.

417101442_KKS_E60.docx - 148 - Rev. 10-06.11


5 Structure
5.1 EMP KKS E60
Fig. 5.1 Fig. 5.2 3 4 6 5
6

4 5
3

1
A
2
1 A

5.2 EMP KKS E60PLUS


Fig. 5.3 Fig. 5.4 3 4 6 5

1 B

Pos. Dsignation
1 Soupape daspiration (raccord du ct aspiration)
2 Ecoulement en cas de rupture de membrane
3 Soupape de pression (raccord du ct pression)
4 Rglage de la longueur de course.
4 Tte de pompe
6 Raccord de retour (retour vers le rservoir !)
A Glissire pour la connexion du module de protection sous botier (Dongle-Box)
B Module de protection sous botier (Dongle-Box)
Sens dcoulement de la matire de dosage

5.3 Afficheurs / Elments de commande / Prises de connexion


5.3.1 Modles EMP KKS E60 et EMP KKS E60PLUS
Fig. 5.5 Pos. Dsignation
1 Bouton tournant pour le rglage de la longueur de course
6
2 Menu/Exit, touche flche vers le haut
1 2
3 Menu/Exit, touche flche vers le bas
3
4 Touche Start/Stop (marche/arrt) (fonction Enter)
4 5 Touche de test
5 6 Afficheur graphique
Entre du pr-avertissement de niveau, et de la
I
signalisation de ltat vide (voir 7.2.2 & 14.5.1)
IV
Entre du signal dimpulsion et du signal normalis, ainsi
II
que du blocage du dosage (voir 7.2.3 & 14.5.2)
I Sortie de la signalisation de ltat vide, du message de
II III
III dfaut et du signal de course (voir 7.2.4 & 14.5.3)
IV Prise de rseau (voir 7.2.5)

5.3.2 Prises de connexion du module de protection sous botier ( Dongle-Box )


Fig. 5.6 Pos. Dsignation
V Entre du compteur roues ovales
Liaison de branchement pour lentre dimpulsion sur la pompe EMP
VI
(entre II)
VII Entre de limpulsion de charge et du blocage du dosage
Entre de limpulsion, entre du signal normalis et du blocage du
VIII
dosage

417101442_KKS_E60.docx - 149 - Rev. 10-06.11


6 Montage
Linstallation doit tre excute uniquement par des ouvriers spcialiss et agrs ; de
ATTENTION plus, il est impratif dobserver les directives gnrales et les prescriptions dinstallation !

La pompe doseuse doit tre monte un endroit bien accessible et tre protge du gel.
La temprature ambiante ne doit pas dpasser +40 C.
Lappareil doit tre mont lhorizontale.
La pompe doit tre fixe au niveau des perages prvus cet effet sur la console ou sur
le rservoir respectivement (pour lentraxe des perages, voir chapitre 14.2 Dimensions).

6.1 Schma de montage


Fig. 6.1 Pos. Dsignation
1 Soupape de surpression
2 Soupape de maintien
3 Lance d'aspiration ou soupape d'aspiration au sol

Les clapets anti retour, les soupapes de maintien de la pression et les soupapes de
REMARQUE surpression peuvent tre remplacs par une soupape multifonctions (MFV) qui figure
dans notre programme de livraison et qui regroupe toutes ces fonctions.

417101442_KKS_E60.docx - 150 - Rev. 10-06.11


7 Installation de lappareil
7.1 Installation hydraulique
7.1.1 Exemples dinstallation
Les applications et les exemples dinstallation mentionns ici ont un caractre
REMARQUE fonctionnel. Ils fournissent une vue densemble sur les modes dinstallation corrects ou
sur ceux qui doivent tre vits, pour le bon fonctionnement de la pompe.
Des mesures spciales et des dispositifs de protection particuliers pour le dosage de
produits chimiques dangereux ou agressifs ne sont pas mentionns ici. Il est absolument
ATTENTION impratif dobserver les prescriptions lgales et la fiche de donnes de produits
correspondantes lors de leur utilisation.
A) La pompe doseuse doit tre implante en priorit sur ou au- Fig. 7.1
dessus du rservoir de dosage.
Avec les matires qui ont tendance se
sdimenter, la soupape daspiration du fond
ou la soupape commande par pdale de la
REMARQUE conduite daspiration ou de la lance
daspiration doit tre monte au-dessus de la
couche de boue laquelle il faut sattendre.
B) Entre la contre-pression au point dinjection et la pression latente
au niveau de la pompe doseuse, il doit rgner une diffrence de
pression positive dau moins 1 bar. Si tel nest pas le cas, il est
impratif d'installer une soupape de maintien (2) dans la conduite
de dosage.
En outre, il est recommand pour viter toute surpression
inadmissible dans la conduite de dosage dinstaller une soupape
de dcharge de scurit (3) approprie. La conduite de dcharge
de cette soupape devra tre ramene sans pression dans le
rservoir.
La conduite de dcharge ne doit pas tre
ATTENTION ramene dans la conduite d'aspiration de la
pompe doseuse !
C) Au point dinjection, il convient en principe de monter une
soupape dinjection (1) ou de dosage ressort (galement en
cas de dosage progressif dans un systme sans pression).
Fig. 7.2
Il faut installer une soupape de maintien de la pression (4) dans la
conduite de dosage lors du dosage dans des tuyauteries o rgne une
dpression.
Une soupape de maintien de la pression ou une
REMARQUE soupape de dosage nest pas un organe darrt
qui se ferme avec une tanchit absolue.
Afin dviter un coulement de la matire de dosage lorsque la pompe
est larrt, nous recommandons de monter en supplment une
soupape magntique (3) qui est libre avec la pompe.
Pos Dsignation
1 Soupape dinoculation / Soupape de dosage
2 Libration externe
3 Soupape magntique
4 Soupape de maintien de la pression
Figb. 7.3

Les conduites daspiration doivent tre maintenues aussi courtes que


possible.
Des conduites daspiration longues et boucles peuvent mener des
accumulations dair dans le systme.
La hauteur daspiration ne doit pas dpasser 2 m au maximum et la
vitesse dcoulement maximale ne doit pas tre suprieure 0,3 m/s !
(voir aussi au chapitre 14.3 Donnes techniques )

417101442_KKS_E60.docx - 151 - Rev. 10-06.11


Fig. 7.4

Toujours poser la conduite daspiration en sens ascendant


vers la soupape daspiration de la pompe doseuse.

Fig. 7.5

Installation dun dispositif de surveillance du dosage :


Un dispositif de surveillance du dosage compteur
roues ovales ou contrleur dcoulement doit tre mont
dans la conduite de dosage aprs la soupape de
surpression et avant une soupape du maintien de la
pression ou une soupape de dosage.

7.1.2 Raccordemnt de la conduite daspiration et de la conduite de pression


Fig. 7.6 Pos. Dsignation
1 Ecrou-raccord
2 Pices pression
3 Pice de raccord
4 Joint torique
5 Perage de fixation
Lors du raccordement de la conduite
daspiration et de la conduite de pression,
PRECAUTIONveiller ce que les joints toriques (pos. 4)
soient monts sur les raccords pour obtenir
ltanchit ncessaire.
Nous recommandons dutiliser une lance
REMARQUE daspiration contenue dans notre programme
de livraison.
Si dautres conduites sont utilises, le rayon
de courbure doit tre adapt.
Le tuyau de retour ne doit pas tre pli.
PRECAUTION Linstallation doit tre effectue de telle
manire quaucune traction ne puisse se
produire sur la conduite de retour.
Sparer le tuyau duo, le couper en suivant le schma et enlever les segments de
raccordement.
Pousser lcrou-raccord (pos. 1) et les pices pression (pos. 2) sur le tuyau
daspiration et enficher le raccord (pos. 3) jusquau collet de bute.
Mettre lanneau noethrien (pos. 4) dans lencoche soupape et serrer lcrou-raccord
la main.
Faire passer le tuyau de retour travers la forure de serrage (pos. 5) et fixer comme le
tuyau daspiration.
Placer la lance daspiration dans le contenant livr.

417101442_KKS_E60.docx - 152 - Rev. 10-06.11


7.1.3 Raccord de la conduite de dosage
Fig. 7.7 Couper la conduite / le tuyau de dosage proprement.
Y mettre lcrou raccord (pos. 2) et lanneau manchon
dformable (pos. 3).
Enficher le tuyau / la conduite dans le raccord (pos. 4) et
fixer la main.
Pour ajuster la positon angulaire, desserrer et resserrer
lcrou (pos. 1).
Tenir compte de la pression maximal
PRECAUTION dutilisation du tuyau / de la conduite de
dosage !
Aprs 24 heures de fonctionnement, les vis
REMARQUE de la tte de dosage doivent tre resserres
diagonalement 3-4 Nm.
Suite un contrle technique, la pompe
PRECAUTION doseuse peut contenir des rsidus deau
dans la tte de dosage

7.2 Installation dlectrique


7.2.1 Entres et sorties
Fig. 7.8 A la livraison, les entres et les sorties sont
V VI I II munies de capuchons de protection qui doivent
tre retirs si ncessaire (pos. I-VIII).
Comme les capuchons de
protection ou les fiches de
connexion sont cods, il
convient de prter attention
REMARQUE aux symboles respectifs
(I-III). Ne pas appliquer une
force excessive lors de la
VII VIII III IV mise en place.
Afin de protger les composants lectroniques contre tout contact avec des produits
chimiques ou de lhumidit, la pompe doseuse ne doit jamais fonctionner sans
ATTENTION capuchons de protection ni cble de connexion car sinon les connexions peuvent
soxyder. Une inversion des capuchons de protection peut occasionner des dfauts de
fonctionnement de la pompe et/ou des dommages sur les connexions !

417101442_KKS_E60.docx - 153 - Rev. 10-06.11


7.2.2 Affectation des connexions - emplacement enfichable I ( 3 broches)
entre du pr-avertissement de niveau et de la signalisation de ltat vide
Fig. 7.9 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
1 brun Entre de pr-avertissement de niveau
3 1 3 bleu Entre de signalisation dtat vide
4 noir Terre GND ()
4 (Voir au chapitre 14.5.1 Donnes techniques pour laffectation des broches des connecteurs.)

7.2.2.1 Installation de la lance daspiration avec pr-avertissement de niveau et signalisation


dtat vide
Si une lance daspiration est utilise, retirer le connecteur borgne et monter le connecteur
de la lance daspiration.
Lemplacement enfichable I doit toujours tre occup soit par les connecteurs de
pontage monts (capuchon de protection avec symbole correspondant, voir au chapitre
REMARQUE 7.2.1, Fig. 7.9, pos. I), soit par la connexion du dispositif de signalisation de ltat vide
(connecteur de la lance daspiration). La logique denclenchement du contact de niveau
peut tre invertie. (confer chapitre: 10.3.8 Configuration du Contact de niveau )
Fig. 7.10
1+4 = Entre de pr-avertissement
de niveau Contact de pr-
avertissement de niveau
ouvert :
Pr-avertissement de niveau actif
(logique denclenchement
inversable, voir chapitre 10.3.8),
le symbole de signal vide
clignote lcran et la pompe
continue fonctionner.
Points Mise en tat d'occupation
1 l' entre du signal
4 Terre GND ()

3+4 = Entre de signalisation


dtat vide
Contact de signal vide ouvert :
Signalisation dtat vide active
(logique denclenchement
inversable, voir chapitre 10.3.8),
le symbole de signal vide
saffiche lcran et la pompe est
bloque.
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 154 - Rev. 10-06.11


7.2.3 Affectation des connexions - emplacement enfichable II ( 5 broches) entre du signal
dimpulsion, du signal normalis, du blocage du dosage, de la charge et de la
surveillance du dosage
Fig. 7.11 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
Sortie 5 V, DC
1 brun
(peut recevoir une intensit maximale de 50 mA)
2 Ente dimpulsion (galement configurable comme
5 2 blanc entre de charge ou de surveillance de dosage, voir
10.3.13 & 10.3.15)
3 1 Ente de blocage de dosage (galement configurable
3 bleu comme entre de charge ou de surveillance de dosage,
voir 10.3.13 & 10.3.15)
4 4 noir Terre GND ()
5 gris Entre de signal normalis 0/4...20 mA
(Voir au chapitre 14.5.2 Donnes techniques pour laffectation des broches des connecteurs.)
Retirer le capuchon de protection.
Monter les fiches de connexion en fonction de laffectation des connexions.
Utiliser uniquement des fiches de connexion qui appartiennent notre programme de
ATTENTION livraison (contenu de la livraison) !

7.2.3.1 Installation de la commande dimpulsion (compteur deau)


Fig. 7.12 2+4 = Entre dimpulsion avec
contact sans potentiel
Points Mise en tat d'occupation
2 l' entre du signal
4 Terre GND ()

1 + 2 + 4 = Entre dimpulsion avec


interrupteur lectronique
(NPN)
Points Mise en tat d'occupation
1 5 V, DC
2 l' entre du signal
4 Terre GND ()

La dure minimale dimpulsion ou de


pause est de 15 ms.

7.2.3.2 Installation de la commande du signal normalis


Fig. 7.13
4+5 = Entre du signal normalis
0/4 20 mA
Points Mise en tat d'occupation
4 0/4-20 mA (-)
5 0/4-20 mA (+)

ATTENTION Lors du raccordement, bien respecter la polarit !

417101442_KKS_E60.docx - 155 - Rev. 10-06.11


7.2.3.3 Installation de la commande via le blocage du dosage
Lentre du blocage de dosage doit tre active dans le menu (confer chapitre: 10.3.7
REMARQUE Configuration du Blocage du dosage ) et est disponible dans tous les modes de
service.
Fig. 7.14 3+4 = Entre de blocage de dosage
avec contact sans potentiel
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()
1 +3 + 4 = Entre de blocage de dosage
avec interrupteur
lectronique (NPN)
Points Mise en tat d'occupation
1 5 V, DC
3 l' entre du signal
4 Terre GND ()

7.2.3.4 Installation de la fonction de charge


Lentre du fonction de charge doit tre active dans le menu. En outre, il est ncessaire
de slectionner les broches qui devront tre utilises pour limpulsion de dmarrage du
REMARQUE dosage par charges, savoir les broches 2+4 (entre impulsion ) ou 3+4 (entre
blocage de dosage ) (voir chapitre 10.3.15).
Fig. 7.15

2+4 = Entre de dosage par charges avec contact sans potentiel en cas de slection de lentre
impulsion dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
2 l' entre du signal
4 Terre GND ()
1 +2 + 4 = Entre de dosage par charges avec interrupteur lectronique (NPN) en cas de slection de
lentre impulsion dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
1 5 V, DC
2 l' entre du signal
4 Terre GND ()

ou
3+4 = Entre de dosage par charges avec contact sans potentiel en cas de slection de lentre
blocage de dosage dans Configuration de la charge (voir chapitre 10.3.15)
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()
1 +3 + 4 = Entre de dosage par charges avec interrupteur lectronique (NPN) en cas de slection de
lentre blocage de dosage dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
1 5 V, DC
3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 156 - Rev. 10-06.11


7.2.3.5 Installation de la surveillance du dosage
La fonction de surveillance du dosage doit d'abord tre active dans le menu. En outre, il
est ncessaire de slectionner les broches qui devront tre utilises pour lentre de
REMARQUE surveillance du dosage, savoir les broches 2+4 (entre impulsion ) ou 3+4 (entre
blocage de dosage ) (voir chapitre 10.3.13).
Fig. 7.16

2+4 = Entre de surveillance du dosage avec contact sans potentiel en cas de slection de
lentre impulsion dans Configuration de la surveillance du dosage
(voir chapitre 10.3.13).
Points Mise en tat d'occupation
2 l' entre du signal
4 Terre GND ()
1 +2 + 4 = Entre de surveillance du dosage avec interrupteur lectronique (NPN) en cas de slection
de lentre impulsion dans Configuration de la surveillance du dosage
(voir chapitre 10.3.13).
Points Mise en tat d'occupation
1 5 V, DC
2 l' entre du signal
4 Terre GND ()

ou
3+4 = Entre de surveillance du dosage avec contact sans potentiel en cas de slection de
lentre blocage de dosage dans Configuration de la surveillance du dosage
(voir chapitre 10.3.13).
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()
1 +3 + 4 = Entre de surveillance du dosage avec interrupteur lectronique (NPN) en cas de slection
de lentre blocage de dosage dans Configuration de la surveillance du dosage
(voir chapitre 10.3.13).
Points Mise en tat d'occupation
1 5 V, DC
3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 157 - Rev. 10-06.11


7.2.4 Affectation des connexions - emplacement enfichable III ( 4 broches)
- sortie de lalarme et du signal de course
Fig. 7.17 Couleur de brin
2 Points (Cble de raccordement)
Mise en tat d'occupation
Sortie de pr-avertissement de niveau, signal vide et
1 brun
dfaut (+)
3 1
Sortie de pr-avertissement de niveau, signal vide et
2 blanc
dfaut (-)
4 3 bleu La sortie du signal de course (+)
4 noir La sortie du signal de course (-)
(Voir au chapitre 14.5.3 Donnes techniques pour laffectation des broches des connecteurs.)

Retirer le capuchon de protection.


Monter les fiches de connexion en fonction de laffectation des connexions.
Utiliser uniquement des fiches de connexion qui appartiennent notre programme de
ATTENTION livraison (contenu de la livraison) !

7.2.4.1 Installation de la sortie niveau et dfaut respectivement


Fig. 7.18 1+2 = Sortie de pr-avertissement
de niveau, signalisation
dtat vide et dfaut
Entre de pr-avertissement de niveau
active :
cycle de la sortie denclenchement
Entre de signalisation dtat vide
active ou entre de dfaut active
respectivement :
Sortie denclenchement ferme (fonction
inversable, voir chapitre 10.3.9 ou 7.2.4.3
respectivement), sortie denclenchement =
contact de relais sans potentiel, charge
24 Vca/cc 3 A ou 115/230 V 3 A
respectivement
Points Mise en tat d'occupation
1 l' entre du signal
2 Terre GND ()
En cas de raccordement dune alimentation 115 V/230 V sur le contact 1+2 (sortie dalarme),
ATTENTION lutilisation simultane du contact 3+4 (sortie de signal de course) nest en gnral pas
autorise.

7.2.4.2 Installation de la sortie du signal de course pour 24 V / DC


Fig. 7.19

3+4 = Sortie de signal de course


chaque course de la pompe, la sortie
denclenchement se ferme une fois.
Sortie denclenchement = sortie
transistorise sans potentiel, charge
24 Vcc, 300 mA

Points Mise en tat d'occupation


3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 158 - Rev. 10-06.11


7.2.4.3 Conversion du matriel pour le contact dalarme
Une fois l'avant de pompe (fig. 7.20) Abb. 7.20
ouvert et dpos, le relais d'alarme
contact inverseur (fig. 7.20, position 1)
est accessible sur la platine de
commande.
Selon la position du pontage de contact de travail
fermeture, il est possible dutiliser tant le (normally open)
contact de repos, que le contact de
travail comme contact dalarme.
Positionnez pour la conversion le
cavalier 3 des broches 1 et 2 sur les
1
broches 2 et 3.
Contact de repos
A la livraison, cest le contact de travail disponible
qui est ajust. (normally closed)

ATTENTION :
REMARQUE Les modifications sur la platine sont rserves un personnel dentretien ou un
personnel qualifi et form!

7.2.4.3.1 Avec le rglage de configuration - sortie dalarme ON


(Voir la description des menus au chapitre 10.3.9)
Si Aucune alarme Si Alarme Power Off
Rglage des cavaliers (le relais dalarme nest (le relais dalarme le relais dalarme
pas activ) est activ) nest pas activ)
Fonction de fermeture :
Contact ouvert Contact ferm Contact ouvert
(Par dfaut)
Fonction douverture : Contact ferm Contact ouvert Contact ferm

7.2.4.3.2 Avec le rglage de configuration sortie dalarme OFF


(Voir la description des menus au chapitre 10.3.9)
Si Aucune alarme Si Alarme Power Off
Rglage des cavaliers (le relais dalarme nest (le relais dalarme le relais dalarme
pas activ) est activ) nest pas activ)
Fonction de fermeture :
Contact ferm Contact ouvert Contact ouvert *
(Par dfaut)
Fonction douverture : Contact ouvert Contact ferm Contact ferm
Fonction fail-safe (scurit en cas de panne)

7.2.5 Affectation des connexions - emplacement enfichable IV, connexion au rseau


Fig. 7.21 La connexion au rseau est assure via un connecteur enfichable quatre broches,
plac sur la face frontale. Celui-ci est dj viss un connecteur en usine.
Couleur de brin
Points (Cble de Mise en tat d'occupation
raccordement)
L1 noir conducteur extrieur / phase
N bleu conducteur neutre
PE jaune / verte conducteur de protection
* - non affect
Afin de garantir ltanchit de la connexion au rseau contre lhumidit, le joint
REMARQUE dtanchit (contenu dans la livraison et dj mont lors de la livraison) doit tre mis en
place et la vis de fixation au centre du connecteur doit tre bien visse.
Relier le cble de connexion au rseau au rseau lectrique.

417101442_KKS_E60.docx - 159 - Rev. 10-06.11


8 Conversion de l EMP KKS E60 sur l EMP KKS E60PLUS
Afin de convertir l EMP KKS E60 sur l EMP KKS E60PLUS plus volue et de pouvoir ainsi
accder aux fonctions supplmentaires, il est ncessaire dacqurir le module de protection
sous botier (Dongle-Box) qui appartient notre programme daccessoires (art. n 248606).

8.1 Montage du module de protection sous botier (Dongle-Box)


Fig. 8.1 Pos. Dsignation
V Entre du compteur roues ovales
Cble de liaison fixe pour connecter lentre dimpulsion la pompe EMP
VI
(entre II)
1 Conducteur de liaison pour la connexion lentre de la pompe
2 Module de protection sous botier
VII Entre de limpulsion de charge et du blocage de dosage
VIII Entre de limpulsion, entre du signal normalis et blocage du dosage
Fig. 8.2 Fig. 8.3

1
2
Monter le module de protection sous botier (fig. 8.1) sur la glissire de la pompe EMP
prvue cet effet (fig. 8.2, pos. A):
Pousser le module de protection sous botier (fig. 8.1) dans la glissire sur le ct
gauche de la pompe EMP (fig. 8.2, pos. A) jusqu ce quil senclenche.
Raccorder le cble de liaison (fig. 8.1, pos. 3 et 8.3, pos. 2) sur lentre dimpulsion/du
signal normalis (fig. 8.2, pos. 1).
mise hors marche et de nouveau mise en marche.
Ainsi, les fonctions supplmentaires dans lunit lectronique de la pompe doseuse sont
actives et peuvent tre excutes.
Si, avant lextension par un module de protection sous botier, un connecteur est enfich
sur lentre dimpulsion / du signal normalis (voir la fig. 8.2, pos. 1), celui-ci peut tre
REMARQUE connect aprs lextension au connecteur VIII (voir la fig. 8.1, pos. VIII) du botier du
module de protection.

417101442_KKS_E60.docx - 160 - Rev. 10-06.11


8.2 Affectation des connexions des emplacements enfichables
8.2.1 Affectation des connexions - emplacement enfichable V ( 5 broches),
entre du compteur roues ovales
Fig. 8.4 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
Alimentation du compteur roues ovales 5 V
1 brun
(peut recevoir une intensit maximale de 50 mA)
PLUS
2 blanc Ligne omnibus pour compteur roues ovales, OGM
3 bleu l' entre du signal
4 noir Terre (GND)
5 gris Libre pour des applications ultrieures
Retirer le capuchon de protection.
Monter les fiches de connexion en fonction de laffectation des connexions.
Utiliser uniquement des fiches de connexion qui appartiennent notre programme de
ATTENTION livraison !

8.2.1.1 Installation du compteur roues ovales (OGM ou OGMPLUS)


La fonction Compteur roues ovales doit d'abord tre active dans le menu. Si un
Plus
REMARQUE OGM est raccord, alors la fonction Compteur roues ovales est automatiquement
active (voir chapitre 10.3.15).
Fig. 8.5 1 +3 + 4 = OGM ou autre surveillance
du dbit avec sortie
denclenchement
lectronique
Points Mise en tat d'occupation
1 5V
3 l' entre du signal
4 Terre GND ()
PLUS
1 + 2 + 3+ 4 = OGM
Points Mise en tat d'occupation
1 5V
2 Signal omnibus
3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 161 - Rev. 10-06.11


8.2.2 Affectation des connexions - emplacement enfichable VII ( 5 broches)
entre de limpulsion de charge et du blocage du dosage
Fig. 8.6 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
Sortie 5 V, DC
1 brun
(peut recevoir une intensit maximale de 50 mA)
2 blanc Entre pour impulsion de charge
3 bleu Entre pour blocage du dosage
4 noir Terre GND ()
5 gris Libre pour la future utilisation
Retirer le capuchon de protection.
Monter les fiches de connexion en fonction de laffectation des connexions.
Utiliser uniquement des fiches de connexion qui appartiennent notre programme de
ATTENTION livraison !

8.2.2.1 Installation pour limpulsion de charge


La fonction de charge doit tre tout dabord active dans le menu. En outre, il est
ncessaire de slectionner les contacts qui devront tre utiliss pour limpulsion de
REMARQUE dmarrage du dosage par charges, savoir les contacts 2+4 (entre impulsion ) ou
3+4 (entre blocage de dosage ) (voir chapitre 10.3.15).
Fig. 8.7

2+4 = Entre de dosage par charges avec contact sans potentiel en cas de slection de lentre
impulsion dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
2 l' entre du signal
4 Terre GND ()
1 +2 + 4 = Entre de dosage par charges avec interrupteur lectronique (NPN) en cas de slection de
lentre impulsion dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
1 5 V, DC
2 l' entre du signal
4 Terre GND ()

ou
3+4 = Entre de dosage par charges avec contact sans potentiel en cas de slection de lentre
blocage de dosage dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()
1 +3 + 4 = Entre de dosage par charges avec interrupteur lectronique (NPN) en cas de slection de
lentre blocage de dosage dans Configuration de la charge (voir chapitre 10.3.15).
Points Mise en tat d'occupation
1 5 V, DC
3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 162 - Rev. 10-06.11


8.2.2.2 Installation du blocage du dosage
Lentre du blocage de dosage doit tre active dans le menu. En outre, il est ncessaire
de slectionner les broches qui devront tre utilises pour lentre de surveillance du
REMARQUE dosage, savoir les broches 2+4 (entre impulsion ) ou 3+4 (entre blocage de
dosage ) (voir chapitre 10.3.15).
Fig. 8.8 3+4 = Entre de surveillance du
dosage avec contact sans
potentiel en cas de slection
de lentre blocage de
dosage dans Configuration
de la surveillance du dosage
(voir chapitre 10.3.13).
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()
1 +3 + 4 = Entre de surveillance du dosage avec interrupteur lectronique (NPN) en cas de slection
de lentre blocage de dosage dans Configuration de la surveillance du dosage
(voir chapitre 10.3.13).
Points Mise en tat d'occupation
1 5 V, DC
3 l' entre du signal
4 Terre GND ()

8.2.3 Affectation des connexions - emplacement enfichable VIII ( 5 broches)


entre dimpulsion, du signal normalis et du blocage du dosage
Fig. 8.9 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
Sortie 5 V, DC
1 brun
(peut recevoir une intensit maximale de 50 mA)
2 blanc Entre pour les impulsions
3 bleu Entre du blocage de dosage
4 noir Terre GND ()
5 gris Entre du signal normalis 0/4-20 mA
Retirer le capuchon de protection.
Monter les fiches de connexion en fonction de laffectation des connexions.
Utiliser uniquement des fiches de connexion qui appartiennent notre programme de
ATTENTION livraison !

8.2.3.1 Installation de la commande dimpulsion (compteur deau)


Fig. 8.10 2+4 = Entre dimpulsion avec
contact sans potentiel
Points Mise en tat d'occupation
2 l' entre du signal
4 Terre GND ()

1 + 2 + 4 = Entre dimpulsion avec


interrupteur lectronique
(NPN)
Points Mise en tat d'occupation
1 5 V, DC
2 l' entre du signal
4 Terre GND ()

REMARQUE La dure minimale dimpulsion ou de pause est de 15 ms.

417101442_KKS_E60.docx - 163 - Rev. 10-06.11


8.2.3.2 Installation du signal normalis (mA)
Fig. 8.11
4+5 = Entre du signal normalis
0/4 20 mA
Points Mise en tat d'occupation
4 0/4-20 mA (-)
5 0/4-20 mA (+)

ATTENTION Lors du raccordement, bien respecter la polarit !

8.2.3.3 Installation du blocage du dosage


Lentre du blocage de dosage doit tre active dans le menu (voir au chapitre 10.3.7)
REMARQUE et est disponible dans tous les modes de service.
Fig. 8.12 3+4 = Entre de blocage de dosage
avec contact sans potentiel
Points Mise en tat d'occupation
3 l' entre du signal
4 Terre GND ()
1 +3 + 4 = Entre de blocage de dosage
avec interrupteur
lectronique (NPN)
Points Mise en tat d'occupation
1 5 V, DC
3 l' entre du signal
4 Terre GND ()

417101442_KKS_E60.docx - 164 - Rev. 10-06.11


9 Mise en service
9.1 Mise en marche de la pompe
Fig. 9.1
2 sec Appuyer sur START/STOP (au moins 2 secondes).

9.2 Arrt de la pompe


Fig. 9.2
5 sec Appuyer sur START/STOP (au moins 5 secondes).

9.3 Fonctions des touches


Touche Dsignation
Fig. 9.3
Fonction MENU/EXIT : accder aux et quitter les niveaux de menu
(maintenir les touches enfonces simultanment)

() Modifier les valeurs ajustes vers le haut

() Modifier les valeurs ajustes vers le bas


Fig. 9.4 Dmarrage de la pompe
Arrt de la pompe
Touche de confirmation (ENTER) pour les valeurs ajustes
Fig. 9.5
Fonction de test (course permanente)

9.4 Symboles Affichs


Display Dsignation
Signal de fonctionnement de la pompe: chaque course de la pompe, le pictogramme en haut
droite de l'cran effectue 1 rotation.
Signal de niveau (pictogramme clignotant = pr alarme de niveau, pictogramme constamment visible
= signal vide), voir 7.2.2.1 Installation de la lance daspiration avec pr-avertissement de niveau et
signalisation de ltat vide ou bien 10.3.8 Configuration / Commutateur dniveau
Blocage du dosage actif, voir 7.2.3.3 Installation de la commande via le blocage du dosage ou bien
10.3.7 Configuration / Blocage du dosage.
Perturbation prsente, voir 12.2 Messages derreur
Interne Mode opration interne, voir 10.2.2 Mode opration / Interne
MUL Mode opration impulsions multiplication, voir 10.2.3 Mode opration / Impulsions
DIV Mode opration impulsions division, voir 10.2.3 Mode opration / Impulsions
x..xx mA Mode opration courant x xx mA, voir 10.2.4 Mode opration / Courant
Charge Mode opration charge voir 10.3.15 Configuration / Charge
xxx /min Affichage en courses/min en mode interne
xx % Affichage en % en mode interne
x.xx l/h Affichage en l/h en mode interne, voir 10.2.2.2 Affichage lcran / rglage mode opration intern
n= x Affichage en mode impulsion, voir 10.2.3.2 Affichage lcran / rglage mode opration impulsion
xx.x mA Affichage en mode courant, voir 10.2.4.2 Affichage lcran / mode opration courant
f = xx.x % Affichage de la frquence de dosage actuelle en %
La pompe est arrte (elle doit tre mise en route), voir 9.5.2 Affichage dans le niveau de
OFF
fonctionnement
Plus
E60+ Donglebox raccord, voir 8 Armement dans Version EMP E60
PLUS
Donglebox et OGM raccords, voir 8.2.1.1 Installation du compteur roues ovales ou bien
E60++
10.3.11 Configuration / Compteur roues ovales
PLUS
MicroFlow MicroFlow branch, voir 10.3.14 Configuration / MicroFlow
Alarme tat de fonctionnement alarme, voir 12.2 Messages derreur

417101442_KKS_E60.docx - 165 - Rev. 10-06.11


9.5 Premire mise en service / Etat la livraison
Lorsque la pompe est livre, elle est configure comme suit
Mode de service: interne
Frquence de course : 122 courses/min. (max. pour 50 Hz) ou 146 courses/min. (max. pour 60 Hz)
Etat : pompe dans ltat de service OFF (Standby pour V 4.0)
Il convient dobserver les options de menu correspondantes dans le chapitre 10.3
REMARQUE Configuration lorsquil sagit de modifier des rglages prconfigurs.

9.5.1 Affichage de la version du logiciel


Fig. 9.6
La version courante du logiciel (1) est affiche en haut
droite de l'cran du menu principal (fig. 9.6 & 9.7).
Les caractres en minuscules qui suivent le numro du
logiciel (2) dcrivent des modifications logicielles internes
qui naffectent pas le fonctionnement de lappareil.
Fig. 9.7

Si une Dongle-Box ou un MicroFlowPLUS a t raccord, la


version de lunit (3) est affiche droit ct de la
version de la pompe.

9.5.2 Affichage dans le niveau de fonctionnement


Dans ltat livr, aprs lapplication de la tension du rseau, les rglages de base suivants
sont affichs lcran.
Fig. 9.8 Mode opration: Interne
frquence de dosage /
quantit de dosage: courses/min (122 courses/min chez 50 Hz,
146 courses/min chez 60 Hz)
tat de service: OFF (pour V 4.1, Standby pour V 4.0)
(Pour le dmarrage Appuyer sur la touche START/STOP)

A chaque course de la pompe, le symbole reprsent en haut droite sur lafficheur


REMARQUE tourne de 1 tour.

9.5.3 Configuration
Dans la configuration, les rglages suivants sont effectus lusine.
Fig. 9.9 Configuration Standard voir chapitre
langue: Franais 10.3.3
units: litre 10.3.4
code: pas activement (-) 10.3.5
dmarrage auto: pas activement (-) 10.3.6
blocage de dosage: pas activement (-) 10.3.7
commutateur d niveau: ouvert () 10.3.8
alarme: arrt () 10.3.9
mmoire impulsions: pas activement (-) 10.3.10
compteur roues ovales: pas activement (-) 10.3.11
rglage du dosage: pas activement (-) 10.3.12
contrle du dosage: pas activement (-) 10.3.13
microflow : pas activement (-) 10.3.14
charge: pas activement (-) 10.3.15
degas: pas activement (-) 10.3.16
microflow Apparat lcran seulement en liaison avec la
surveillance de dosage MicroFlowPLUS disponible dans les
accessoires

417101442_KKS_E60.docx - 166 - Rev. 10-06.11


10 Description des menus
10.1 Menu principal
Le menu principal peut tre appel pendant le fonctionnement de la pompe.
L'entre s'effectue par un appui simultan sur les touches et .
Un appui simultan supplmentaire sur les touches et permet de retourner lindicateur
de progression de lappel

10.1.1 Vue densemble


Fig. 10.1

Mode opration voir au : chapitre 10.2

Configuration voir au : chapitre 10.3

talonnage voir au : chapitre 10.4

Donnes dopration voir au : chapitre 10.5

417101442_KKS_E60.docx - 167 - Rev. 10-06.11


10.2 Mode opration
10.2.1 Slectionner
Fig. 10.2

Des rglages voir chapitre:


Interne 10.2.2
Impulsions 10.2.3
Courant 10.2.4

10.2.2 Mode opration / Interne


Le mode opration intern permet dutiliser la pompe de dosage sans signal externe.
Les variantes daffichage suivantes peuvent tre slectionnes :
Courses/min La vitesse de dosage rgle (et donc la quantit de dosage)
affiche en courses/min. (par dfaut)
Pourcentage La vitesse de dosage rgle (et donc la quantit de dosage)
affiche en pourcentage
Litre* La quantit de dosage rgle est affiche en litres/heure
(ou en gallons / jour ou en gallons / heure).
Conversion des litres en gallon, voir chapitre 10.3.4

10.2.2.1 Slectionner
Fig. 10.3

417101442_KKS_E60.docx - 168 - Rev. 10-06.11


10.2.2.2 Affichage lcran dans lindicateur de progression de lappel / rglage
Le rglage de la quantit de dosage peut tre effectu dans lindicateur de progression de
lappel pendant le fonctionnement.
Si la valeur nouvellement ajuste nest pas confirme dans les 10 prochaines
REMARQUE secondes par une pression de la touche START/STOP , cest la valeur en cours,
ajuste au pralable, qui reste conserve.
Courses/min
Fig. 10.4

Pourcentage (%)
Fig. 10.5

Litres/heure Gallons/jour
Fig. 10.6 Fig. 10.7

10.2.3 Mode opration / Impulsions


En mode opration "Impuls" la pompe de dosage fonctionne seulement en liaison avec des
impulsions (provenant par exemple d'un compteur d'eau contact).
Les variantes de traitement des impulsions suivantes peuvent tre slectionnes :
Multiplication Les impulsions entrantes sont multiplies par un facteur (n) rglable :
1 impulsions = n courses de la pompe (Par dfaut)
Division Les impulsions entrantes sont divises par un facteur (n) rglable :
n impulsions = 1 course de la pompe

417101442_KKS_E60.docx - 169 - Rev. 10-06.11


10.2.3.1 Slectionner
Fig. 10.8

10.2.3.2 Affichage lcran dans lindicateur de progression de lappel / rglage


Le rglage du facteur de multiplication ou de division est effectu dans lindicateur de
progression de lappel et peut tre effectu pendant le fonctionnement de la pompe.
Multiplication
Fig. 10.9

REMARQUE
Si la valeur nouvellement ajuste nest pas
confirme dans les 10 prochaines secondes par
Division une pression de la touche START/STOP ,
Fig. 10.10 cest la valeur en cours, ajuste au pralable, qui
reste conserve.

417101442_KKS_E60.docx - 170 - Rev. 10-06.11


10.2.4 Mode opration / Courant (signal normalis externe)
En mode opration strom , la pompe fonctionne selon un signal entrant normalis. Le
signal qui arrive (0/4-20 mA; 20-0/4 mA ou rglable) est converti en une frquence de
dosage 0-100 % (rapport course/pause), par exemple :
Les variantes fonctionnement suivantes peuvent tre slectionnes :
0 20 mA 0 mA = 0% frquence de dosage, 20 mA = 100 % frquence de dosage
4 20mA 4 mA = 0% frquence de dosage, 20 mA = 100 % frquence de dosage
20 0 mA 20 mA = 0% frquence de dosage, 0 mA = 100 % frquence de dosage
20 4 mA 20 mA = 0% frquence de dosage, 4 mA = 100 % frquence de dosage
Choix par oprateur n (rglable) mA = 0 % frquence de dosage,
n (rglable) mA = 100 % frquence de dosage

10.2.4.1 Slectionner
Fig. 10.11

voir au : chapitre 10.2.4.1.1

417101442_KKS_E60.docx - 171 - Rev. 10-06.11


10.2.4.1.1 Rglage mode opration / courant / choix par oprateur
La diffrence des valeurs ajustes doit tre suprieure ou gale 5.
REMARQUE (par exemple, min. 10, max. 15).
Fig. 10.12

10.2.4.2 Affichage dans lindicateur de progression de lappel


Affichage lcran Pos Dsignation
Fig. 10.13
1 Zone de travail pr-ajuste dans le menu

2 Intensit du courant qui passe actuellement

3 Frquence de course en %

10.3 Configuration
10.3.1 Vue densemble
Fig. 10.14 Configuration: voir chapitre:
Langue de menu 10.3.3
Units 10.3.4
Entre du code 10.3.5
Rglages de dmarrage 10.3.6
Blocage du dosage 10.3.7
Commutateur dniveau 10.3.8
Sortie dalarme 10.3.9
Mmoire dimpulsions 10.3.10
Compteur roues ovales 10.3.11
Rgulateur de dosage 10.3.12
Contrle du dosage 10.3.13
MicroFlow 10.3.14
Cette rubrique du menu n'apparat qu'en liaison avec le
contrle de dosage MicroFlow disponible en tant
qu'accessoire et remplace la rubrique de menu Contrle
de dosage.
Charge 10.3.15
Degas 10.3.16

417101442_KKS_E60.docx - 172 - Rev. 10-06.11


10.3.2 Dfilement de lafficheur
Fig. 10.15 Lafficheur dispose dune fonction de dfilement, cest--dire
certaines options de menu sont affiches seulement si la fin du menu
est atteinte dans lafficheur. Les symboles (1) ou (2) dans
lafficheur permettent de reconnatre dans quelle direction il est
possible de dfiler.
1 = () dfiler laffichage de lafficheur vers le haut
2 = () dfiler laffichage de lafficheur vers le bas

10.3.3 Configuration / Langue


La langue du menu peut tre slectionne ici.

10.3.3.1 Slectionner
Fig. 10.16

Par dfaut = Allemand

10.3.4 Configuration / Unit


Si, en mode opration Intern, la variante daffichage Litres est slectionne (voir 10.2.2),
laffichage peut ici tre converti de litres/heure en gallons/jour (1 gallon = 3.785 litres).

10.3.4.1 Slectionner
Fig. 10.17

Par dfaut = litre

417101442_KKS_E60.docx - 173 - Rev. 10-06.11


10.3.5 Configuration / Code
Lors de ce rglage, une combinaison de chiffres peut tre indique pour scuriser les
valeurs rgles contre une modification non autorise.
Si code" est activ, ce code quatre chiffres doit tre entr avant toute modification ou
tout changement dans le menu principal.

10.3.5.1 Slectionner
Fig. 10.18

- la fonction de code est inactive.


(Par dfaut)

la fonction de code est active.

Voir au chapitre 10.3.5.2

10.3.5.2 Rglage
Fig. 10.19

10.3.6 Configuration / Dmarrage auto


Cette fonction permet de dterminer si la pompe passe dans l'tat "OFF" ("standby" pour V
4.0) lors dun retour de la tension du rseau aprs une panne de courant ou si la pompe doit
immdiatement redmarrer dans le mode opration rgl.

417101442_KKS_E60.docx - 174 - Rev. 10-06.11


10.3.6.1 Slectionner
Fig. 10.20

- Dmarrage auto est inactive.


La pompe se place toujours dans la
fonction de service OFF (Standby
pour V 4.0) lorsque la tension de
rseau est enclenche.
(Par dfaut)

Dmarrage auto est active.


Lors de lapplication de la tension du
rseau, la pompe passe dans ltat de
fonctionnement couramment
slectionn.

10.3.7 Configuration / Blocage du dosage


En cas d'activation du blocage de dosage, la pompe ne fonctionne que lorsqu'un contact
dautorisation externe est ferm sur le connecteur II (ou sur le connecteur VII ou VIII
respectivement en cas dutilisation dune Dongle Box) entre les broches 3+4 (pour le
raccordement lectrique, vois chapitre 7.2.3.3, 8.2.2.2 ou 8.2.3.3 respectivement).
Lutilisation du blocage de dosage est ainsi indpendante du mode slectionn.

10.3.7.1 Slectionner
Fig. 10.21

- la demande du blocage du dosage


est inactive (Par dfaut)

la demande du blocage du dosage


est active.

10.3.8 Configuration / Commutateur dniveau


Cela permet de dterminer si, lentre du niveau (connecteur I voir chapitre 7.2.2.1) un
contact ouvert ou ferm est considr comme niveau correct.

417101442_KKS_E60.docx - 175 - Rev. 10-06.11


10.3.8.1 Slectionner
Fig. 10.22

= Contact ouvert :
Niveau incorrect (vide)
Contact ferm :
Niveau correct (plein)
(Par dfaut)

= Contact ferm :
Niveau incorrect (vide)
Contact ouvert :
Niveau correct (plein)

10.3.9 Configuration / Alarme


Cette option permet l'inversion de la sortie d'alarme (le relais de sortie d'alarme est activ ou
non en cas d'alarme).

10.3.9.1 Slectionner
Fig. 10.23

= En cas dalarme le relais


de la sortie dalarme est activ
(Par dfaut)
= En cas dalarme le relais
de la sortie dalarme nest pas
activ
En plus du fonctionnement du relais, il
est galement possible de choisir si,
lorsque le relais est activ, le contact
du relais de sortie dalarme doit tre
ferme (fonctionnement en contact
fermeture, par dfaut) ou ouvert
(fonctionnement en contact
ouverture) (voir chapitre 7.2.4.3
Rglage du fonctionnement du contact
du relais dalarme).

10.3.9.2 Rglage du fonctionnement du contact du relais dalarme


Voir au chapitre 7.2.4.3

417101442_KKS_E60.docx - 176 - Rev. 10-06.11


10.3.10 Configuration / Mmoire dimpulsions
Si la frquence des impulsions est suprieure la frquence max. pouvant tre traite par
la pompe (frquence max. de la pompe, par exemple 122 courses/min 50 Hz), il est
possible d'enregistrer les impulsions non traites.
Les impulsions enregistres sont traites aprs la fin des impulsions. Cela signifie que la
pompe continue de fonctionner bien quil nexiste aucune condition externe.
ATTENTION Dans un cas dfavorable, cela peut provoquer le dosage dans un systme ferm et donc
une pression excessive dans le systme.
Cela doit tre empch par des mesures de scurit appropries.
Le contenu de la mmoire est effac ds que le blocage du dosage est activ ou ds que la
pompe est mise hors tension.

10.3.10.1 Slectionner
Fig. 10.24

- La mmoire dimpulsions est


inactive. (Par dfaut)

La mmoire dimpulsions est


active.

10.3.10.2 Affichage dans lindicateur de progression de lappel lorsque la mmoire


dimpulsions est active
Affichage en fonctionnement Signification Pos Dsignation
Fig. 10.25 1 Mmoire dimpulsions active
Multiplication 2 Nombre des impulsions appliques
dimpulsion
3 Facteur ajust
(Exemple : 10
impulsions externes
gnrent 20 courses)
Fig. 10.26
Division dimpulsion
(Exemple : 10
impulsions externes
gnrent 5 courses)

417101442_KKS_E60.docx - 177 - Rev. 10-06.11


10.3.11 Configuration / Compteur roues ovales (justement E60PLUS & OGM or OGM PLUS)
Le fonctionnement du compteur roue ovale permet une mesure "relle" des quantits
dans la rubrique du menu Donnes de fonctionnement / Litres (voir chapitre 10.5.3).
De plus, lactivation de ce choix du menu est la condition pour pouvoir utiliser la fonction de
rgulateur de dosage (voir chapitre 10.3.12).
Le compteur roue ovale ne peut tre activ que si la pompe est munie dune Dongle-
PLUS
Box pour E60 et si un compteur roue ovale (voir Accessoires) a t branch.
Pour lactivation de la Dongle Box en combinaison avec le compteur roue ovale, la
REMARQUE tension du rseau doit tre dbranche et rebranche. (Retirer la prise ou bien arrter et
redmarre la pompe)
PLUS
En cas de branchement dun OGM , le compteur roue ovale est automatiquement
activ.

10.3.11.1 Slectionner
Fig. 10.27

- Compteur du dosage est inaktiv.


(Par dfaut)

Compteur du dosage est aktiv

10.3.12 Configuration / Rglage du dosage (justement E60PLUS & OGMPLUS)


Fig. 10.28

Lorsquun OGM Plus est raccord, la quantit de dosage mesure par lOGM est compare
avec une valeur de consigne rgle de quantit de dosage lors de lactivation du rgulateur
de dosage. En cas dcart, la frquence de dosage de la pompe est automatiquement
augmente ou, le cas chant, rduite.
Dans la mesure o le rglage ultrieur de la frquence de dosage est uniquement possible
dans les limites de puissance de la pompe, il est recommand de rgler le point de
consigne de la quantit de dosage sur 80-90 % de la frquence de dosage max. possible.
Ainsi, le rgulateur de dosage a des rserves vers le haut pour ragir aux carts de rglage
ngatifs.
La fonction du rgulateur de dosage peut uniquement tre utilise dans les modes de
fonctionnement Intern et Strom . En mode Impuls , le rgulateur de dosage est
hors service.
La fonction de rgulateur de dosage peut tre active uniquement si la pompe a t
quipe dun module de protection sous botier (Dongle-Box) pour devenir une pompe
PLUS PLUS
REMARQUE E60 et si un compteur roues ovales, type OGM , (voir les accessoires) est
raccord. Pour lactivation de la Dongle Box en combinaison avec le compteur roue
ovale, la pompe doit tre arrte et redmarre.

417101442_KKS_E60.docx - 178 - Rev. 10-06.11


10.3.12.1 Slectionner
Fig. 10.29

- La fonction de rgulation est


inactive. (Par dfaut)

La fonction de rgulation est


active.

10.3.12.2 Affichage dans lindicateur de progression de lappel lorsque le rgulateur de


dosage est activ
Fig. 10.30 = cart de dosage vers le bas
La pompe dbite actuellement moins que ce qui est exig par
la frquence de course pr-ajuste (ici par exemple 100/min.).
La frquence de dosage est augmente automatiquement
jusqu ce que la valeur de lcart soit compense.
Fig. 10.31
- = cart de dosage
La pompe dbite exactement la quantit qui est pr-ajuste
(ici par exemple 100/min.).
Il nest pas ncessaire deffectuer une rgulation pour corriger.

Fig. 10.32 = cart de dosage vers le haut


La pompe dbite actuellement plus que ce qui est exig par la
frquence de course pr-ajuste (ici par exemple 100/min.).
La frquence de dosage est diminue automatiquement
jusqu ce que la valeur de lcart soit compense.
Fig. 10.33
la carte mre du module de protection est installe.
REMARQUE
le compteur roues ovales OGMPLUS est raccord.

10.3.13 Configuration / Contrle du dosage


Lorsque le contrle du dosage est activ, les courses de la pompe sont compares avec les
impulsions entrantes par une contrle du dosage externe (par exemple un compteur roue
ovale). Si une limite de tolrance rglable est dpasse, il en rsulte un message dalarme.
Lunit de surveillance du dbit peut tre raccorde dans le cas du connecteur II (ou du
connecteur V en cas dutilisation dune Dongle Box) sur les broches 2+4 (entre
dimpulsion) ou sur les broches 3+4 (entre de blocage de dosage) (pour la slection de
lentre, voir chapitre 10.3.13.5, pour le raccordement lectrique, voir chapitre 7.2.3.5 ou
8.2.1.1 respectivement).
Lorsquun compteur roue ovale est branch pour le contrle du dosage et doit tre
REMARQUE ananlys de manire correspondante, la fonction Configuration / Compteur Roue Ovale
doit galement tre active en plus de Configuration / contrle du dosage (voir 10.3.11).

417101442_KKS_E60.docx - 179 - Rev. 10-06.11


10.3.13.1 Slectionner
Fig. 10.34

- Contrle du dosage est inactiv.


(Par dfaut)

Contrle du dosage est activ.

L'activation du contrle du
dosage fait apparatre un sous-
menu avec les rubriques
suivantes :
Rubrique du menu chapitre
Arrt pompe 10.3.13.2
Courses 10.3.13.3
cart 10.3.13.4
Entre bloc. dosage 10.3.13.5

10.3.13.2 Contrle du dosage / Arrt pompe


Avec arrt pompe , on dtermine si la pompe doit tre arrte ou continuer de
fonctionner si une Alarme Contrle de dosage est dclenche.
Fig. 10.35

- La pompe nest pas arrte :


En cas de Alarme Contrle de
dosage (Par dfaut)

La pompe est arrte :


En cas de Alarme Contrle de
dosage

10.3.13.3 Contrle du dosage / Courses


Loption courses donne lintervalle de courses surveiller
Fig. 10.36

Plage de rglage: 0 100

Par dfaut = 10

417101442_KKS_E60.docx - 180 - Rev. 10-06.11


10.3.13.4 Contrle du dosage / cart (justement E60PLUS & OGM ou OGMPLUS)
Dans cart , une tolrance en % est rgle.
La frquence proprement dite des impulsions provenant du compteur roue ovale
lintrieur de lintervalle de pompage surveiller (voir 10.3.13.3 Configuration / Courses) est
compare une frquence dimpulsions de consigne dtermine lors de ltalonnage.
Si, lors de cette comparaison, un cart suprieur la valeur en pourcentage rgle dans la
rubrique cart , une Alarme Contrle de dosage est dclenche.
Cette fonction ne peut tre slectionne que si Dongle Box est branche et si
REMARQUE Configuration / Compteur Roue Ovale a t activ (voir chapitre 10.3.11).
Fig. 10.37

Plage de rglage: 0-100%

Par dfaut = 20 %

10.3.13.5 Contrle du dosage / Entre blocage dosage (seulement pour E60 SANS
Dongle-Box)
Le rglage entre permet de dterminer par quelle entre (entre des impulsions ou
blocage du dosage) du connecteur II (ou du connecteur V en cas dutilisation dune Dongle
Box) de la pompe, les impulsions provenant de lunit de contrle du dosage doivent tre
analyses.
La surveillance du dbit doit alors tre branche diffremment selon lentre slectionne :
Entre impulsassions: = connecteur II (ou connecteur V), broches 2+4
Entre blocage de dosage: = connecteur II (ou connecteur V), broches 3+4
Voir au chapitre 7.2.3.5
Cette fonction ne peut tre slectionne que si aucune Dongle Box nest branche.
REMARQUE La fonction initiale (par exemple entre des impulsions) ne peut alors plus tre utilise.
Fig. 10.33

417101442_KKS_E60.docx - 181 - Rev. 10-06.11


10.3.13.6 Affichage des impulsions du compteur roue ovale (seulement pour E60PLUS)
Fig. 10.39 Le nombre dimpulsions qui a t dtermin lors du
dernier talonnage est affich ici (dure du
calibrage = 1 min).
Si la valeur est infrieure 60, un contrle de
dosage avec compteur roue ovale nest possible
que de manire limite.

10.3.14 Configuration / MicroFlowPLUS


PLUS
Lors du branchement de lunit de contrle de dosage MicroFlow (Art. N 248611)
au connecteur II de la pompe et de lactivation de la fonction Plug&Play grce un bref
arrt de la tension dalimentation ou un arrt et un redmarrage de la pompe, la
REMARQUE rubrique de menu Configuration / Surveillance de dosage est automatiquement
remplace par Configuration / MicroFlow.
PLUS
Pour linstallation / mise en service du systme de contrle du dosage MicroFlow , lire
attentivement la notice correspondante Art. N 417101314.
Cette fonction permet un contrle de dosage dans lequel, chaque course de la pompe,
une impulsion de dosage est gnre et analyse de manire approprie.
Les rglages standards enregistrs pour courses , cart , pause de dosage et
retard de dosage ne peuvent tre considrs que comme des prrglages.
La sensibilit du systme MicroFlow doit tre adapte individuellement en fonction du
IMPORTANT type de linstallation (par ex., type de produit chimique, quantit de dosage, coupe
transversale, longueur de conduite, etc.) et en fonction des conditions sur le site, en
modifiant les paramtres mentionns ci-dessus.

10.3.14.1 Slectionner
Fig. 10.40
PLUS
- MicroFlow est inactive
(Par dfaut)
PLUS
MicroFlow est active

PLUS
L'activation du MicroFlow fait
apparatre un sous-menu avec les
rubriques suivantes :
Rubrique du menu chapitre
Arrt pompe 10.3.14.2
Courses 10.3.14.3
tart 10.3.14.4
Pause de dosage 10.3.14.5
Retard de dosage 10.3.14.6
talonnage 10.3.14.7

417101442_KKS_E60.docx - 182 - Rev. 10-06.11


10.3.14.2 MicroFlowPLUS / Arrt pompe
Fig. 10.41
Avec arrt pompe , on
dtermine si la pompe doit tre
arrte ou continuer de fonctionner
si une Alarme Contrle de
dosage est dclenche.

- La pompe nest pas arrte lors


dune Alarme Contrle de
dosage (Par dfaut)

La pompe est arrte lors dune


Alarme Contrle de dosage

10.3.14.3 MicroFlowPLUS / Courses


Fig. 10.42

Loption courses donne


lintervalle de courses surveiller
Plage de rglage: 0-100

Par dfaut = 40 courses

10.3.14.4 MicroFlowPLUS / cart


L'option cart dfinit le nombre de courses non dtects qui sont autoriss dans l'intervalle
de courses surveill (voir chapitre 10.3.14.3 Courses ) avant que le contrle de dosage
n'mette une alarme.
Fig. 10.43

Exemple : courses = 40, cart = 20


Dans cet exemple, 20 courses
non reconnues sont acceptes
dans un intervalle de 40 courses.
Si 21 courses ne sont pas
reconnues, une alarme se met en
marche.
Plage de rglage: 0-100

Par dfaut = 20

417101442_KKS_E60.docx - 183 - Rev. 10-06.11


10.3.14.5 MicroFlowPLUS / Pause de dosage
Pour la manipulation d'agents prsentant un risque de dgagement gazeux, les arrts
prolongs provoquent la formation d'inclusions de gaz dans le systme. Ces inclusions de
gaz faussent le dosage du volume, conduisant par la suite la non-dtection des courses
par le MicroFlowPLUS et au dclenchement d'une alarme.
Fig. 10.44
Pause de dosage permet de
rgler le temps aprs lequel, sans
processus de dosage, la
surveillance est dsactive pour
un temps dtermin (voir
10.3.14.6 MicroFlowPLUS / retard
de dosage) afin dempcher une
activation involontaire de la
surveillance.
Plage de rglage: 2 - 3600s

Par dfaut = 240 sec.

10.3.14.6 MicroFlowPLUS / Retard de dosage


Pour la manipulation d'agents prsentant un risque de dgagement gazeux, l'option Retard
de dosage permet de dfinir le temps pendant lequel le contrle de dosage sera dsactiv
lors du dosage pour assurer le dgazage du systme.
Le retard de dosage est activ ds qu'un dosage est effectu aprs coulement de la
pause de dosage (voir chapitre 10.3.14.5).
Exemple : pause de dosage = 240 s, retard de dosage = 40 s
Dans cet exemple, le contrle de dosage du MicroFlowPLUS est interrompu pendant un temps
de 240 secondes (retard de dosage) compter du dbut du dosage qui suit la pause de
dosage de 40 secondes, pendant laquelle aucun dosage n'a eu lieu.
Fig. 10.45

Pendant ce temps, les bulles de


gaz qui se sont formes le cas
chant dans le systme peuvent
tre vacues sans dclencher
d'alarme.
Plage de rglage: 2 - 3600s

Par dfaut = 40 sec.

417101442_KKS_E60.docx - 184 - Rev. 10-06.11


10.3.14.7 MicroFlowPLUS / talonnage
L'option talonnage permet de r talonner l'enregistreur de valeurs de mesure la
premire mise en service ou l'occasion d'un changement de produit.

IMPORTANT
Lors du calibrage, la pompe correctement paramtre doit tre en marche et le fluide de
dosage doit traverser sans bulle le capteur.
Avec lactivation de talonnage , les valeurs pour la conductivit min. (liaison conductrice
entre les tiges du capteur interrompue) et la conductivit max. (liaison conductrice) sont
dtermines.
Le dosage par charges peut tre interrompu par la dsactivation de lautorisation (blocage de
dosage) ou par larrt de la pompe.
Fig. 10.46

A partir de ces deux valeurs, une


diffrence est calcule et affiche.
Pour une bonne surveillance, la
diffrence doit tre suprieure 34.

10.3.15 Configuration / Charge


REMARQUE La pompe doit tre calibre avant dutiliser le dosage de charge (voir au chapitre: 10.4).
En cas dactivation du mode par charges, une quantit pralablement dfinie est dose avec
une frquence de course de 100 % via un signal de dmarrage au connecteur II (ou au
connecteur VII en cas dutilisation dune Dongle Box) sur les broches 2+4 (entre
dimpulsion) ou les broches 3+4 (entre de blocage de dosage) (pour la slection de lentre,
voir chapitre 10.3.15.3, pour le raccordement lectrique, voir chapitre 7.2.3.4 ou chapitre
8.2.2.1 respectivement).
Le dosage par charges peut tre interrompu par la dsactivation de lautorisation (blocage de
dosage) ou par larrt de la pompe.

417101442_KKS_E60.docx - 185 - Rev. 10-06.11


10.3.15.1 Slectionner
Fig. 10.47

- Charge est inactive


(Par dfaut)

Charge est active

Lorsque le dosage par charges


est activ, les rubriques suivantes
apparaissent dans le sous-menu :
Rubrique du menu chapitre
Quantit 10.3.15.2
Entre 10.3.15.3

10.3.15.2 Charge / Quantit


Quantit permet de dterminer la quantit de dosage souhaite (en l, ml, l ou g) par
processus de dosage par charges. Plage de rglage: 0 99999
Fig. 10.48

417101442_KKS_E60.docx - 186 - Rev. 10-06.11


10.3.15.3 Charge / Entre (seulement pour E60 SANS Dongle-Box)
Le rglage entre permet de dterminer par quelle entre (entre des impulsions ou
blocage du dosage) du connecteur II (ou du connecteur VII en cas dutilisation dune Dongle
Box) de la pompe, limpulsion de dmarrage pour le dosage par charges doit tre analyse.
Le cble pour limpulsion de dmarrage doit alors tre branch diffremment selon lentre
slectionne :
Entre impulsion = Connecteur II (ou connecteur VII), broches 2+4
Entre blocage du dosage = Connecteur II (ou connecteur VII), broches 3+4
voir au chapitre 7.2.3.4 et 8.2.2.1.
Cette fonction ne peut tre slectionne que si aucune Dongle Box nest branche.
REMARQUE La fonction initiale (par exemple entre des impulsions) ne peut alors plus tre utilise.
Fig. 10.49

Par dfaut = blocage du dosage

10.3.15.4 Affichage dans lindicateur de progression de lappel


Fig. 10.50 Pos Dsignation
1 Mode opration
2 Quantit encore doser
3 Courses restantes encore excuter

10.3.16 Configuration DegasPLUS


Lors de l'activation de la fonction DegasPLUS et du raccordement dune soupape de
dgazage correspondante, cette fonction permet un dgazage contrl du systme de
dosage. Pour linstallation / mise en service de la soupape de dgazage, lire attentivement
la notice correspondante Art. N 417101377.

417101442_KKS_E60.docx - 187 - Rev. 10-06.11


10.3.16.1 Slectionner
Fig. 10.51

PLUS
- Degas est inactive
(Par dfaut)

PLUS
Degas est active

Lorsque le contrle de dgazage


est activ, les rubriques suivantes
apparaissent dans le sous-menu :
Rubrique du menu chapitre
Degas courses 10.3.16.2
Degas pause 10.3.16.3

10.3.16.2 Degas / Degas courses


Fig. 10.52

Degas Courses permet de


rgler le nombre de courses qui
doivent tre effectues lors dun
intervalle de dgazage.
Plage de rglage: 1-100

Par dfaut = 0

417101442_KKS_E60.docx - 188 - Rev. 10-06.11


10.3.16.3 Degas / Degas pause
Degas Pause permet de rgler le temps entre deux intervalles de dgazage.
Si, pendant ce temps, un dosage est requis, celui-ci sera effectu et le temps de pause
DegasPLUS est rinitialis et redmarr.
Plage de rglage: heure 00 - 23
minutes 00 - 59
total 00.01 - 23.59h
Fig. 10.53

Par dfaut
= 00:00

10.4 talonnage
10.4.1 Vue densemble
Le procd et laffichage de ltalonnage dpendent du fait quun compteur roue ovale est
branch ou non.
Fig. 10.54
talonnage pompe:
Voir au chapitre 10.4.2
talonnage pompe avec
compteur du dosage:
Voir au chapitre 10.4.3

417101442_KKS_E60.docx - 189 - Rev. 10-06.11


10.4.2 talonnage / pompe
10.4.2.1 Prparation
Fig. 10.55

Brancher la pompe du ct de la
pression (voir chapitre 7 Installation
des appareils ).
Remplir les cylindres de mesure
appropris et insrer la conduite
daspiration ou conduite de dosage et
conduite de retur.

Le volume maximal du cylindre de mesure ne doit pas dpasser 1/50 de la puissance de


la pompe doseuse.
La position du tuyau daspiration ne doit pas tre modifie pendant cette procdure.
REMARQUE Pendant le processus de calibrage, le tuyau daspiration ne doit pas changer de
position. Ltalonnage de la pompe de dosage est valable seulement pour le rglage de
course actuel. Aprs la modification de la course, ltalonnage doit tre effectu
nouveau.

10.4.2.2 talonnage / Dmarrage


Fig. 10.56

concernant : La pompe effectue 122 courses (environ 1 min.)


Les courses sont comptes rebours de 122 0.
Il est possible dabandonner le calibrage en cours en appuyant sur la fonction
REMARQUE Menu/Exit .

concernant : A la fin du processus, la quantit prleve dans le cylindre de mesure


(voir chapitre 10.4.2.1 Prparation) doit tre lue.
Cette quantit est alors entre en tant que valeur dtalonnage
(en ml ou en l).

10.4.3 talonnage / pompe avec compteur roues ovales (OGMPLUS)


Si une Dongle Box et un compteur roues ovales sont branchs et si, dans la
Configuration, la fonction Compteur roues ovales est activ (voir chapitre 10.3.11), la
frquence dimpulsions du compteur roues ovales est automatiquement affiche aprs le
calibrage.
Cette frquence est compense avec la valeur dtalonnage saisie. Il est ainsi possible de
faire correspondre les impulsions du compteur roues ovales et la quantit dose.

417101442_KKS_E60.docx - 190 - Rev. 10-06.11


10.4.3.1 Prparation
Fig. 10.57
Brancher la pompe du ct de la
pression (voir chapitre 7 Installation
des appareils ).
Remplir les cylindres de mesure
appropris et insrer la conduite
daspiration ou conduite de dosage et
conduite de retour.

Le volume maximal du cylindre de mesure ne doit pas dpasser 1/50 de la puissance de


la pompe doseuse.
La position du tuyau daspiration ne doit pas tre modifie pendant cette procdure.
REMARQUE Pendant le processus de calibrage, le tuyau daspiration ne doit pas changer de
position. Ltalonnage de la pompe de dosage est valable seulement pour le rglage de
course actuel. Aprs la modification de la course, ltalonnage doit tre effectu
nouveau.

10.4.3.2 talonnage / Dmarrage


Fig. 10.58

concernant : La pompe effectue 122 courses (environ 1 min.)


Les courses sont comptes rebours de 122 0.
Les impulsions du compteur roues ovales (impulsions OGM) sont
comptes partir de 0.
Il est possible dabandonner le calibrage en cours en appuyant sur la fonction
Menu/Exit .
REMARQUE Si les impulsions OGM ne sont pas affiches, vrifier tous les branchements aux
connecteurs de la pompe.

concernant : A la fin du processus, la quantit prleve dans le cylindre de mesure


(voir chapitre 10.4.2.1 Prparation) doit tre lue.
Cette quantit est alors entre en tant que valeur dtalonnage
(en ml ou en l).
Fig. 10.59

Pendant le calibrage, les impulsions du compteur


roues ovales sont affiches lcran.

417101442_KKS_E60.docx - 191 - Rev. 10-06.11


10.4.4 talonnage / Manuelle
Si la valeur dtalonnage saisir est connue, il est possible d'effectuer un talonnage
sec (saisie immdiate de la valeur sans calibrage pralable).
Cette mthode n'est cependant pas trs prcise car les conditions sur le site (contre-
pression, viscosit, section et longueur des conduites etc.) ne sont pas prises en compte.
Fig. 10.60

10.4.4.1 Tableau des donnes de calibrage


Les valeurs dtalonnage indiques dans le tableau permettent dtablir une
correspondance entre llectronique de la pompe et la puissance de pompage
correspondante en l/h.
Exemple :
Une valeur saisie de 23,3 ml donne une puissance de pompage de 1,4 l/h.
REMARQUE Ces valeurs sont valables pour de l'eau 20C comme milieu de dosage.
Capacit de la pompe [l/h] Valeur dtalonnage pompe [ml]
Pompe 50 (60) Hz 50 (60) Hz
0,2 (0,24) 3,33 (4,00)
KKS

0,5 (0,6) 8,33 (10,0)


Fig. 10.61
0,9 (1,1) 15,0 (18,3)
1,4 (1,7) 23,3 (28,3)

10.5 Donnes dopration


Cette option permet la sortie et la remise zro des donnes de service :
heures dopration
litres
nombre dimpulsions

417101442_KKS_E60.docx - 192 - Rev. 10-06.11


10.5.1 Vue densemble
Fig. 10.62

Voir au chapitre 10.5.2

Voir au chapitre 10.5.3

Voir au chapitre 10.5.4

10.5.2 Donnes dopration / Heures dopration


Le temps de fonctionnement de la pompe (correspondant au nombre de courses x 480 ms)
depuis la premire mise en service ou depuis la dernire rinitialisation est affich ici.

10.5.2.1 Slectionner / afficher / annuler


Fig. 10.63

10.5.3 Dones dopration / Litres


La quantit dose en litres depuis la premire mise en service ou depuis la dernire
rinitialisation est affiche ici. En cas dutilisation de la pompe sans compteur roues
ovales, cette valeur est calcule (ml / course x nombre des courses de dosage). En cas de
branchement dun compteur roues ovales, la quantit mesure est affiche (dtermine
partir du nombre dimpulsions du compteur roues ovales).

10.5.3.1 Slectionner / afficher / annuler


Fig. 10.64

417101442_KKS_E60.docx - 193 - Rev. 10-06.11


10.5.4 Donnes dopration / Nombre dimpulsions
Le nombre dimpulsions entres par lintermdiaire de lentre des impulsions de la pompe
(connecteur II, broches 3+4, voir chapitre 7.2.3 Fonction des broches Connecteur II )
depuis la premire mise en service ou depuis la dernire rinitialisation est affich ici.

10.5.4.1 Slectionner / afficher / annuler


Fig. 10.65

417101442_KKS_E60.docx - 194 - Rev. 10-06.11


11 Maintenance
Seules les personnes expertes et agres sont autorises excuter des travaux de
PRECAUTION maintenance sur les pompes doseuses.
Intervalle de maintenance : tous les six mois; choisir des intervalles plus rduits lors
REMARQUE de conditions dutilisation plus extrmes (par exemple, course permanente).
Les contrles suivants sont recommands :
le raccord sans fuite de la conduite daspiration et de la conduite de pression.
la prsence de salets et ltanchit de la soupape daspiration et de la soupape de pression
(chapitre 11.1, Fig. 11.1),
le raccord dcoulement (chapitre 5, Fig. 5.1) sur la tte de pompe (rupture de membrane),
le dosage correct, les crous-raccord (chapitre 7.1.2, Fig. 7.6 et chapitre 7.1.3, Fig. 7.7
)
la bonne mise en place des vis de dosage (chapitre 11.2, Fig. 11.3, pos. 2)
(contrler si elles sont bien serres, couple de serrage 3 - 4 Nm).
La dure de vie de la membrane dpend des facteurs suivants :
contre-pression, temprature de service et matire de dosage.
REMARQUE Il est recommand de contrler plus souvent la membrane lors de conditions de
service extrmes et lors du dosage de substances abrasives.

11.1 Remplacement de la soupape daspiration/ soupape de retour


Fig. 11.1 Pos. Dsignation
SET DE LA RACCORDEMENT
1 Ecrou-raccord
A
2 Pice de serrage
3 Pice conique
SOUPAPE DASPIRATION/
SOUPAPE DE RETOUR
4 Joint torique, 10 x 2,5
B
Soupape daspiration/
5
Soupape de retour
6 Joint torique, 14 x 2,5
C RACCORD ANGULAIRE
SOUPAPE DE PRESSION
4 Joint torique, 10 x 2,5
6 Joint torique, 14 x 2,5
D Soupape de pression
I Le ressort d' soupape
7
II Le billes d' soupape
III Joint torique, 12 x 1,5

Dmonter la soupape daspiration/ soupape de retour (pos. 5/7) avec une cl fourche
(ouverture de cl 22).
Il faut veiller sur la soupape de pression (pos. 7) ne pas perdre le ressort de soupape
REMARQUE (pos. I), la bille de soupape (pos. II) et le joint torique (pos. III), ainsi qu monter ces
composants dans la position correcte pendant le rassemblage.
Monter tous les joints toriques.
Visser une nouvelle soupape daspiration/ soupape de retour dans la position correcte
(couple de serrage 2-3 Nm).

417101442_KKS_E60.docx - 195 - Rev. 10-06.11


11.1.1 Montage des soupapes de dosage dans la position correcte
Fig. 11.2
Sur les soupapes daspiration/ soupape de retour, le sens
dcoulement est indiqu par une flche grave.
Lors de lassemblage, il faut absolument veiller ce que les
soupapes soient mises en place en fonction du sens
dcoulement !

11.2 Remplacement de la membrane et de la tte de pompe


Fig. 11.3

Pos. Dsignation
1 Tte de pompe
2 Vis de la tte de dosage
3 Piston cramique
4 Membrane complet
5 Soufflet
6 Plaque intermdiaire

Avant douvrir la tte de pompe :


ATTENTION vider les conduites de raccordement,
rincer la tte de pompe.
Desserrer les vis de la tte de dosage (pos. 2)
Extraire la tte de pompe (pos. 1) absolument en ligne droite.
Linclinaison peut dtruire le cylindre cramique! Suivre les flches du dessin de
ATTENTION montage!
Retirer le piston cramique (pos. 3) latralement de lembrayage de la membrane (pos.
4).
Puis dvisser la membrane (pos. 4).
Enlever la plaque intermdiaire (pos. 6).
Remplacer le soufflet (pos. 5).
Pour monter la membrane (pos. 4), ne pas serrer trop fort.
Le collecteur de fuite de la plaque intermdiaire (pos. 6) doit regarder vers le bas.
Remettre le piston (pos. 3).
fixer le cylindre prcautionneusement dans la tte de pompe.
Visser fermement les vis de la tte de pompe la main
Visser les vis de la tte de pompe en diagonale
REMARQUE Couple de serrage des vis de la tte de dosage = 3 - 4 Nm.
Contrler le couple de serrage des vis de la tte de dosage aprs 24 heures !
ATTENTION Fixer la tte de pompe sans lincliner. La tte de dosage doit tre serre diagonalement
et de manire rgulire.

417101442_KKS_E60.docx - 196 - Rev. 10-06.11


11.3 Remplacement du cylindre cramique avec piston
Suivre les instructions du chapitre 11.2.
Fig. 11.4 Pos. Dsignation
1 Cylindre cramique
2 Joint torique, 22 x 2 (FPM)
3 Joint torique, 22 x 2 (EPDM)
4 Ressort
5 Joint torique, 14 x 2,5
6 Raccords filets
7 Plaque
8 Bille de soupapes
9 Joint torique, 12 x 1,5
Dvisser les raccords filets
des soupapes (pos. 6).
Enlever plaque (pos. 7), bille
de soupapes (pos. 8) et
ressort (pos. 4).
Retirer le cylindre cramique
(pos. 1) en tournant en
direction membrane.
Fixer la nouvelle pice. Changer les joint torique (pos. 2, 3, 5, 9).
Remonter le raccord filet (pos. 6), la bille de soupape (pos. 8), etc.
Pour pouvoir remplacer le cylindre cramique il faut galement changer le piston
ATTENTION cramique.

11.4 Ajustement du dispositif de rglage de course mcanique


Fig. 11.5 Fig. 11.6 Pos. Dsignation
1 Bouton de rglage de course
2 Vis sans tte (2 x loppos)
Marquages des boutons de rglage
3
(fig. 32 = 0 point)
4 Logement de la tte de rglage (avec denture)
5 Echelle de vernier
6 Raccord de dosage
Au moment de sa production, la pompe doseuse
est ajuste la pression nominale,
conformment aux courbes de dosage. Si en
enlevant le bouton de rglage, le rglage de
course a t modifi, il est toujours possible de
dterminer la position initiale comme suit:
Enclencher la pompe doseuse.
Desserrer les 2 vis sans tte opposes
(pos. 2).
Le bouton du rglage de course (pos. 1) peut
maintenant tre extrait de la denture qui se
trouve en dessous (pos. 4).
Tourner le logement du bouton de rglage (pos. 4) lentement vers la gauche
(dans le sens inverse des aiguilles dune montre) jusqu ce que plus aucune
matire ne scoule du raccord de dosage (pos. 6).
Pousser le bouton du rglage de course (pos. 1) avec la marque 0 (pos. 3) vers le haut de
manire recouvrir le trait de marquage de lchelle de vernier (pos. 5).
Le bouton du rglage de course est pouss sur la denture jusqu ce que le rebord
extrieur ait atteint la marque 0 (pos. 5) de lchelle de vernier.
Pour finir, visser nouveau les vis sans tte (pos. 2).
Maintenant, le rglage de course est ajust sur le rglage dusine.
Il convient de vrifier la capacit en litres de la pompe pour dterminer exactement la
REMARQUE performance de dosage.

417101442_KKS_E60.docx - 197 - Rev. 10-06.11


12 Dfauts de service
12.1 Message davertissement - Dosage (afficheur)
Si plus aucun signal externe nest trait et si les signaux de sortie (tat vide, dfaut) sont
dsactivs, les messages derreur suivants peuvent apparatre sur lafficheur de la pompe
doseuse :
Afficheur Signification Rpercussion Origine Elimination
Fig. 12.1

Message de rserve La pompe continue Le pr-avertissement de Constituer une rserve


(clignotant). de tourner. niveau est actif. en matire de dosage.

Fig. 12.2
Signalisation de La pompe est La signalisation de ltat Constituer une rserve
ltat vide. arrte. vide est active. en matire de dosage.
Activer la libration
externe ou positionner le
Blocage du dosage
Fig. 12.3 blocage du dosage dans
(possible seulement La pompe est Aucune libration externe
le menu de
si celui-ci a t arrte. de la pompe.
configurations sur
configur).
inactif (voir au
chapitre 10.3.7).
Laffichage dans le
Le signal normalis est
mode de service 4..20
Fig. 12.4 en dessous de 3 mA ou
mA clignote. La pompe est Contrler le signal
le cble vers le raccord
La surveillance du arrte. normalis ou le cble.
du signal normalis est
signal normalis
rompu.
ragit.
Fig. 12.5 Le signal normalis Le signal normalis
La pompe tourne en Diminuer le signal
est au-dessus de dpasse ltendue
--.- 23;0 mA.
mode permanent.
daffichage.
normalis.

12.2 Messages derreur (afficheur)


afficheur Signification Rpercussion Origine Elimination
Fig. 12.6 Le moteur
tourne en Lunit lectronique de
permanence de Dosage excessif puissance est Remplacer la carte mre.
manire dfectueuse.
incontrle.
Fig. 12.7
Le moteur est
larrt bien que La contre-pression est
Aucun dosage. Diminuer la pression.
le symbole de trop leve.
dosage tourne.

Le moteur est
Alimenter la pompe.
Fig. 12.8 dfectueux.
Le moteur
alarm ! La carte mre est
tourne en dfectueuse.
Dosage permanent. Alimenter la pompe.
failure 3 permanence Il nexiste aucune
motor control sans demande. liaison entre la Emboter fermement un
transmission et la carte tenon rflexe sur la
mre (opt.). transmission.
Il y a une erreur Le tuyau flexible est Contrler les tuyaux
Fig. 12.9 dans lvaluation dfectueux. flexibles.
alarm ! de la La membrane est
La pompe dose trop Contrler la membrane.
surveillance du dfectueuse.
failure 4 ou trop peu.
dosage ou du La contre-pression est
oval gear meter
compteur Contrler la contre-
trop leve ou trop
roues ovales. pression.
basse.

417101442_KKS_E60.docx - 198 - Rev. 10-06.11


12.2.1 Tableau derreurs
Dfaut Origine possible Elimination
La pompe doseuse ne fonctionne Le cble de rseau est Remplacer le cble de rseau.
pas, aucun affichage sur lafficheur. endommag.
La tension est errone. Contrler la tension de rseau.
La pompe naspire pas malgr la Formation de dpts ou Rincer la tte de dosage via la conduite
purge et la course maximale. damalgames ; les soupapes se daspiration, dmonter ventuellement les
sont dessches. soupapes et les nettoyer ou les remplacer.
La tte de dosage nest pas tanche, La tte de dosage sest Visser les vis de fixation de la tte de dosage
de la matire schappe de desserre. en diagonale.
lcoulement en cas de
La membrane sest dchire. Remplacer la membrane.
rupture de membrane.
Le flotteur de la lance daspiration Dbloquer le flotteur.
Lindicateur de niveau apparat
est bloqu.
sur lafficheur bien que le
rcipient soit plein. Le connecteur de la lance Bien serrer le connecteur, nettoyer les contacts,
daspiration ou le connecteur de Vrifier si le connecteur de pontage est
pontage se sest desserr ou nest enfich.
pas enfich.
Le cble de la lance daspiration Remplacer le dispositif de signalisation de
est dfectueux. ltat vide.

Avant de procder aux travaux de maintenance et de rparation, ainsi quau dosage de


matires dangereuses, il faut toujours rincer la tte de dosage, dcharger la conduite
PRECAUTION de pression et porter des vtements de protection (lunettes de protection, gants de
protection et tablier).

Seuls des lectriciens spcialiss sont autoriss excuter des rparations de nature lectrique
(observer les rgles de scurit de la caisse de prvoyance daccidents VB G 4 et ZH 1/11) !
Des composants qui conduisent la tension, peuvent tre dgags lorsque des
PRECAUTION couvercles sont ouverts ou lorsque des pices sont retires, sauf si cela est possible
sans outil. Des lments de raccordement peuvent aussi conduire la tension.

Avant dexcuter un quilibrage, une maintenance, un entretien ou un remplacement des


pices, il faut absolument dbrancher lappareil de toutes les sources de tension sil est
ncessaire de louvrir.

417101442_KKS_E60.docx - 199 - Rev. 10-06.11


13 Pices dusure et pices dtaches (modle standard)
13.1 Vue clate
Fig. 13.1

Pos Dsignation Typ 00002 Typ 00005 Typ 00009 Typ 00014
Set de la raccordement angulaire PVDF, G 3/8i tuyau 2/4 mm (ID/AD) 247613 --
1
Set de la raccordement angulaire PVDF, G 3/8"i - tuyau 4/6 mm (ID/AD) -- 247620
2 crou tte carre 413226005
3 Vis 413401178
4 Bouton de rglage de course 34070193
Soupape de pression PVDF/FPM (Viton B),
247623 --
DRV PVFPKE004 G3/8-G3/8-99 00002
Soupape de pression PVDF/FPM (Viton B)
-- 247624 --
DRV PVFPKE008 G3/8-G3/8-99 0005/00009
Soupape de pression PVDF/FPM (Viton B)
-- 247630
DRV PVFPKE008 G3/8-G3/8-99 00014
5
Soupape de pression PVDF/EPDM,
247631 --
DRV PVEPKE004 G3/8-G3/8-99 00002
Soupape de pression PVDF/EPDM,
-- 247632 --
DRV PVEPKE008 G3/8-G3/8-99 00005/00009
Soupape de pression PVDF/EPDM
-- 247633
DRV PVEPKE008 G3/8-G3/8-99 00014
6 Plaque 34070186
7 crou de rglage 34070185
8 Cylindre complet 247607 247609 247605 247604
SDVPVFPKE000 G3/8-G3/8-99 Soupape de refoulement, PVDF/FPM
248405
9 (Viton B)
SDVPVEPKE000 G3/8-G3/8-99 Soupape de refoulement, PVDF/EPDM 248406
Set de la raccordement 3/8 PVDF pour tuyau 6/8, 6/10, 6/12 mm 247629
10
Set de la raccordement 3/8 PVDF pour tuyau duo 6/10 mm (ID/AD) 247610
11 Tte de pompe, PVDF 34070192
12 Piston - cylindre complet 247601 247608 247602 247601
13 Plaque intermdiaire 34070173
14 Membrane de protection 34760112
15 Connecteur shunt entre signal de niveau bas 248186
16 Connecteur shunt entre signal dimpulsion 248187
17 capuchon 34800117
18 Connecteur 4 ples, entre du signal de niveau bas/dimpulsion 418463115
19 Connecteur 5 ples E 30/32 entre courant / impulsion 418463118
20 Connecteur 4 ples sortie du signal de niveau bas/dimpulsion 418463117
21 Couvercle 34800120
22 Cordon lectrique EMP KKS/II E600 2m 34860001

417101442_KKS_E60.docx - 200 - Rev. 10-06.11


13.2 Kit de pices d'usure
Comportant chaque fois 1 pice des composants suivants :
- soupape d'aspiration, ct aspiration (Pos. 9)
- soupape de refoulement, retour (Pos. 9)
- soupape de refoulement, ct pression (Pos. 5)
- Set de la raccordement pour tuyau 4/6, 6/8, 6/12 mm (ID/AD), (Pos. 10)
- Membrane (Pos. 12)
- disque d'appui (Pos. 13)
- membrane de protection (Pos. 14)
Dsignation (Kit de pices d'usure EMP KKS) Article n
00002 PVFPKE 247676
00005 PVFPKE 247677
00009 PVFPKE 247678
00014 PVFPKE 247679
00002 PVEPKE 247686
00005 PVEPKE 247687
00009 PVEPKE 247688
00014 PVEPKE 247689

1. Type de pompe (Dbit de la pompe)


00002 = 0,2 l/h
00005 = 0,5 l/h
00009 = 0,9 l/h
00014 = 1,4 l/h
2. Matriau des soupapes
PV = PVDF
3. Matriau des joints
FP = Viton B
EP = EPDM
4. Matriau des billes
KE = cramique
Kit de pices d'usure EMP KKS 0 0 0 1 4 PV FP KE

417101442_KKS_E60.docx - 201 - Rev. 10-06.11


14 Donnes techniques
14.1 Codes de pompe
1. Version lectrique
...
E 60 = (Explications : voir au chapitre 14.1.1)
...
2. Dbit de la pompe 50 Hz (60 Hz)
00002 = 0,2 l/h (0,24 l/h)
00005 = 0,5 l/h (0,6 l/h)
00009 = 0,9 l/h (1,1 l/h)
00014 = 1,4 l/h (1,7 l/h)
3. Matriel tte de pompe
PV = PVDF (standard)
4. Contre-pression du dosage
10 = 10 bar (8 bar)
5. Matriel joints
FP = Viton B (standard)
EP = EPDM
KA = Kalrez
6. Matriel billes
KE = cramique (standard)
GL = verre
7. Matriel soupape
PV = PVDF (standard)
8. Ressorts de soupape
99 = sans ressort (standard)
9. Type de cble
17 = cble dalimentation 2 m
fiche femelle et fiche contact de protection
(E60, 230 V) (standard)
21 = cble dalimentation 2 m
fiche femelle et manchons de bout pour torons
(E60, 115 V)

10. Tension/frquence
01 = 115V / 50 Hz
02 = 115V / 60 Hz
03 = 230V / 50 Hz (standard)
04 = 230V / 60 Hz

E 60 00 0 09 PV 10 FP KE PV 99 17 03

Autres spcifications sur demande !

417101442_KKS_E60.docx - 202 - Rev. 10-06.11


Codes de pompe 2

11.Connexion ct aspiration
04 = set pour tuyau PE 6/8
05 = set pour tuyau PVC 6/10
06 = set pour flexible PVC 6/12
33 = set pour tuyau 6/8, 6/10, 6/12 (standard)
12. Connexion ct pression
31 = set angulaire pour tuyau PE/PTFE 2/4
(standard pour 0,2 l/h)
32 = set angulaire pour tuyau PE/PTFE 4/6
(standard pour 0,5 - 1,4 l/h)
34 = set angulaire pour tuyau 2/4, 4/6
13. Connexion matriel
99 = PVDF
14. Rglage mcanique de la course
99 = sans rglage mcanique de la course
15. Dtecteur de rupture de membrane
99 = sans dtecteur
16. Version du botier
01 = botier standard

33 32 P V 99 99 01 Autres spcifications sur demande !

Exemple Code:

E 60 00 0 09 PV 10 FP KE PV 99 17 03 - 33 32 P V 99 99 01
( Pompe code 1 ) ( Pompe code 2 )

417101442_KKS_E60.docx - 203 - Rev. 10-06.11


14.1.1 Dfinition du code de pompe E60
Version lectrique
E 60 Interrupteur principal pour la mise sous/hors tension de la pompe
Ecran graphique clair en arrire-plan, 4 touches de commande
Commande de course individuelle (chaque course est excute entirement)
Contrle du dosage possible via la sortie du signal de course (par calculs)
ou via le systme externe de la surveillance du dosage
Saisie des donnes de service et de consommation (par calculs)
Fonction de calibrage
Modes de service ajustables :
Mode interne
Rglage de la quantit de dosage / frquence de dosage en :
Courses / min.
Pourcentage
Litres/h (ou gallons/h)
Mode externe
Mode dimpulsion (commande par impulsions)
- Multiplication dimpulsion (1 impulsion arrivante = n courses de dosage)
- Division dimpulsion (n impulsions arrivantes = 1 course de dosage)
Mode de signal normalis (commande via le signal normalis externe 0/4 - 20 mA ou 20 - 0/4 mA)
Mode de charge (dclench par une impulsion dautorisation externe ; une quantit ajuste est
dose auparavant).
Entres :
Surveillance du niveau dans les contenants (pr-avertissement de niveau et signalisation de ltat
vide)
Impulsion
Signal normalis
Autorisation
Sorties :
Surveillance du niveau dans les contenants
(pr-avertissement de niveau et signalisation de ltat vide)
Message de dfaut
Signal de course

E 60PLUS comme E 60, mais avec en plus le module de protection sous botier (Dongle Box)
(unit dextension pour la saisie des donnes de service)
Affichage de la quantit de dosage rellement mesure / temps et rgulation complmentaire
automatique du dbit de la pompe (seulement en liaison avec un systme externe de
surveillance du dbit, comme par exemple un compteur roues ovales)
Fonction de calibrage automatique via le compteur roues ovales
Contrle des donnes de consommation au moyen du compteur roues ovales

417101442_KKS_E60.docx - 204 - Rev. 10-06.11


14.2 Dimensions
Fig. 14.1

417101442_KKS_E60.docx - 205 - Rev. 10-06.11


14.3 Donnes techniques Tableau de vue densemble
14.3.1 Donnes gnrales
Type de pompe
Dsignation
00002 00005 00009 00014
Tension dalimentation 230 V / 50/60 Hz 10 %
(tensions spciales sur demande)
max. courant absorb IN 115V 50/60 Hz 0,2 A / 0,21 A
230V 50/60 Hz 0,09 A
Puissance du moteur 115V 50/60 Hz
18,7 / 19,8 W
230V 50/60 Hz
Valeur de fusible 315 mA
Type de protection IP 65
Puissance de distribution pour une mise en circuit sous 24 V
Sortie de signalisation de ltat vide 24 V 3 A AC/DC
Sortie du signal de course 24 V 0,3 A DC
Puissance de distribution pour une mise en circuit sous 230 V
Sortie de signalisation de ltat vide 230 V / 3 A AC/DC
Sortie du signal de course Raccord selon VDE non autoris

14.3.2 Dones gnerals


Type de pompe
Dsignation
00002 00005 00009 00014
Dbit de la pompe [l/h]*/** 0,2 0,5 0,9 1,4
Contre-pression maximale de dosage [bar] 10
diamtre du piston [mm] 3 4,76 6,34 8
Nombre de courses [1/min] pour 50 Hz 122
Quantit de dosage / course [cm] 50Hz/60Hz 0,027/0,032 0,068/0,082 0,12/0,44 0,19/0,23
Prcision de reproduction [voir au chapitre 14.6] < 3%
Viscosit maximale pouvant tre convoye [mPas] 200
Temprature ambiante maximale 5-40C
Hauteur daspiration [mWs] pour un rglage de course de 100%*** 2
Max. admissible pr-pression [bar] 0,3
Niveau sonore (dBA) une distance de 1 m
54,0
(daprs DIN EN 12639/ EN ISO 9614-2)
Raccords de tuyau
6/8, 6/10, 6/12
conduite daspiration / conduite de retur [ID mm]
Raccords de tuyau
2/4 4/6
conduite de pression [ID mm]
Poids [kg] 2,4
* Les valeurs sont dtermines avec de leau comme matire de dosage sous une temprature de 20C.
** Avec une frquence de rseau de 60 Hz, la performance de dbit augmente de 20 % et la contre-pression de dosage
diminue de 20 %.
*** Les hauteurs daspiration ont t dtermines avec des soupapes propres et humidifies pour une course de dosage de
100% et une frquence de course maximale.

417101442_KKS_E60.docx - 206 - Rev. 10-06.11


14.3.3 Montage dentre / Montage dsorties
14.3.3.1 Douille fiche I
Fig. 14.2 Entre Affectation Mise en circuit externe Valeurs
1 (brun)
Signalisation de ltat + contact sans potentiel
vide 4 (noir) Attention ;
3 (bleu) ne brancher aucune
Reserve + tension externe !
4 (noir)

14.3.3.2 Douille fiche II


Fig. 14.3 Entre Affectation Mise en circuit externe Valeurs
2 (blanc)
+ Dure denclenchement et de
Impulsion contact sans potentiel
4 (noir) dconnexion minimale : 15 ms
Attention ;
Blocage du 5 (gris) ne brancher aucune
dosage/charge/surve + tension externe !
illance du dosage 4 (noir)
Circuit externe
3 (bleu)
+ Attention ; observer la 0/4-20 mA, rsistance ohmique : environ
Signal normalis
4 (noir) polarit du signal 50 ohm
raccord !
Sorties Affectation Mise en circuit externe Valeurs
1 (brun) contact sans potentiel
Attention ; alimentation pour appareils externes
Alimentation externe +
ne brancher aucune sortie: 5VDC; max. 50mA
4 (noir)
tension externe !

14.3.3.3 Douille fiche III


Fig. 14.4 Sorties Affectation Mise en circuit externe Valeurs
Contact sans potentiel (relais) ;
1 (brun) tension maximale externe 230 VAC/DC,
Signalisation de ltat max. 3A
vide / de rserve / + Alimentation externe pour la signalisation de rserve:
des dfauts 2 (blanc) contact environ ca. 500 ms ferm
contact environ ca. 500 ms ouvert
Contact sans potentiel (lectronique) ;
tension maximale externe 24VDC, max.
0,3A
lors de limmobilisation : contact ouvert
pour un rseau de 50 Hz:
course de 100%:
contact environ 310 ms ferm
Alimentation externe contact environ 180 ms ouvert
3 (bleu) course de 50%:
Signal de course + Attention ; observer contact environ 310 ms ferm
4 (noir) la polarit du signal contact environ 660 ms ouvert
raccord !
pour un rseau de 60 Hz:
course de 100%:
contact environ 260 ms ferm
contact environ 150 ms ouvert
course de 50%
contact environ 260 ms ferm
contact environ 550 ms ouvert

417101442_KKS_E60.docx - 207 - Rev. 10-06.11


14.4 Matriau
Tte-de-pompe: PVDF
Piston/cylindre-de-dosage: cramique
Membrane: PTFE-EPDM-membrane composite
Joints: FPM (Viton B), optionnellement EPDM, Kalrez
Soupapes: PVDF
Billes-de-soupapes: Cramique
Anneau-noethrien: FPM, choix EPDM
Ressorts-de-soupapes: Hastelloy C4/C22 enduit de PTFE
Botier: polyester thermoplastique
Couleur: bleu RAL 5007
Modles spciaux sur demande.

14.5 Affectation des broches des connecteurs


14.5.1 Brochage et couleurs des fils du connecteur I (3 broches)
Raccord du pr-avertissement de niveau ou signalisation de ltat vide
Fig. 14.5 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
1 brun Pr-avertissement de niveau
3 bleu Signalisation de letat vide
4 noir Terre GND
voir aussi au chapitre : 7.2.2

Si la signalisation de ltat vide nest pas utilise, le contact 3/4 doit toujours tre
ATTENTION pont ! Le capuchon de protection prvu cet effet (voir au chapitre 7.2.1) tablit le
pontage entre les contacts et doit tre enfich dans ce cas.
Les entres de signalisation de ltat vide et de rserve peuvent tre inverses dans le
REMARQUE menu Configuration / Contact de niveau (voir au chapitre 10.3.8).

14.5.2 Brochage et couleurs des fils du connecteur II (5 broches)


Raccord de lentre dimpulsion / du signal normalis et blocage du dosage
Fig. 14.6 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
1 brun Sortie 5 V, DC
2 blanc Entre dimpulsassions
3 bleu Entre dblocage de dosage
4 noir Terre GND
5 gris Entre du signal normalis 0/4 20 mA
voir aussi au chapitre 7.2.3
Lentre du blocage du dosage est active seulement si elle a t ajuste au pralable dans le
menu Configuration / blocage du dosage (voir au chapitre 10.3.7). La fonction Charge
HINWEIS (voir au chapitre 10.3.15) et la surveillance du dosage (voir au chapitre 10.3.13) doivent tre
galement configures.

14.5.3 Brochage et couleurs des fils du connecteur III (4 broches)


Raccord de la sortie de signalisation de ltat vide, des dfauts et du signal de course
Fig. 14.7 Couleur de brin
Points Mise en tat d'occupation
(Cble de raccordement)
Sortie de pr-avertissement de niveau,
1 brun
signalisation dtat vide et dfaut (+)
Sortie de pr-avertissement de niveau,
2 blanc
signalisation dtat vide et dfaut (-)
3 bleu Sortie de signal de course (+)
4 noir Sortie de signal de course (-)
voir aussi au chapitre 7.2.4
Avec 230 V, un raccordement simultan des contacts 1+2 (signalisation de ltat vide) et
ATTENTION 3+4 (sortie du signal de course) est interdit selon le VDE.

417101442_KKS_E60.docx - 208 - Rev. 10-06.11


14.6 Performances de dosage
Lexactitude de dosage reproductible se monte environ 3 % pour une longueur minimale
de course de 30 % et des conditions constantes.
En raison de la caractristique de la pompe, des performances plus leves peuvent se
produire jusqu ce que la temprature de service soit atteinte (mode permanent : au moins
2 heures).
Il est possible dobtenir un dosage exact si les points suivants sont observs :
a) Toutes les indications sur la performance de dosage se rfrent des mesures avec
de leau une temprature de 20C, une tension dalimentation constante et lorsque la
pompe doseuse a atteint la temprature de service.
b) Pour obtenir une haute exactitude de dosage pendant le dosage dans lvacuation
libre, il faut utiliser une soupape de maintien de pression (ou une soupape de dosage)
afin de gnrer une contre-pression dau moins 0.5 bar qui reste si possible constante.
c) Si une pr-pression est applique sur le ct aspiration, la pression diffrentielle entre
le ct pression et le ct aspiration doit se monter au moins 1 bar. La colonne deau
en formation sur la pompe doseuse doit tre assure par un agencement de soupapes
correspondant.
Une soupape de maintien de pression ou une soupape de dosage nest pas un organe
REMARQUE darrt qui ferme absolument.
Le rglage de la course de dosage doit tre excut uniquement lorsque la pompe
ATTENTION tourne, si la vis de rglage de course est dcharge.

14.7 Dbit estim en fonction de la contre-pression


Fig. 14.8
1.6

1.5

1.4

1.3

1.2

1.1

0.9
Dbit (l/h)

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0
1 2 3 4 5 6 7 8 9 10

Contre-pression (bar)

417101442_KKS_E60.docx - 209 - Rev. 10-06.11


14.8 Dbit estim en fonction du rglage de dosage
Exactitude de rglage : + 15 % - 5 % de la valeur nominale, toutes les indications se rfrent
de leau sous une temprature de 20 C et conformment aux indications figurant dans les
notices techniques.
REMARQUE Les courbes de performance sont reprsentes pour une frquence de pompe de 50 Hz.

Fig. 14.9
1.6

1.5

1.4

1.3

1.2
2 bar type 014
2 bar Typ 014
1.1

1
Dbit (l/h)

0.9 10 bar type


10 bar 014
Typ 014

0.8

0.7 2 bar type


2 bar 009
Typ 009

0.6
10 bar type
10 bar 009
Typ 009
0.5
2 bartype
2 bar Typ 005005
0.4

0.3 10 bar
10 bartype 005
Typ 005
0.2 2 bartype
2 bar Typ 002002

0.1 10 bar
10 bartype
Typ 002002
0
0 10 20 30 40 50 60 70 80 90 100
Hauteur de leve (%)

417101442_KKS_E60.docx - 210 - Rev. 10-06.11


15 Dclaration de conformit

417101442_KKS_E60.docx - 211 - Rev. 10-06.11

Vous aimerez peut-être aussi