The Toughest Meters For Environment Test & Measurements

APPA 50 SERIES DIGITAL THERMOMETER

APPA 51 Thermometer
Maximum Record
K-type thermocouple
Reading hold
Large LCD display (18.5 mm) function

1oC or 0.1oC (1oF or 0.1oF) Standard 9V


resolution battery

0.3%+loC basic accuracy Protective holster

o
C or oF display Bead probe
included

APPA 52 Thermometer
K-type thermocouple
o
C or oF display
Large LCD display
Maximum Record
(18.5mm)
Reading hold
Dual thermocouple input
function
Differential temperature (T1
Standard 9V battery
-T2)
Protective holster
1oC or 0.1oC (1oF or 0.1oF)
resolution Two bead probes
included
0.3% +1 C basic accuracy
o

APPA 53 Thermometer
K-type thermocouple (J-type Reading hold
optional) function

Microcomputer designed Auto Ranging

Large dual 4 digit LCD display Stop Watch


Function
0.1%+0.7oC basic accuracy
Protective holster
User selectable resolution
Bead probe
Maximum/Minimum Record included
APPA 55 Thermometer
K-type thermocouple (J-
type optional) Maximumi /
Minimum Record
Microcomputer designed
Reading hold
Large dual 4 digit LCD function
display
Auto Ranging
Dual Thermocouple input
Stop Watch Function
Differential temperature (T1
-T2) Protective holster

0.1%+0.7oC basic accuracy Two bead probes


included
User selectable resolution

SPECIFICATIONS: (All at 18oC to 28oC, <80% R.H.)

APPA APPA APPA APPA


51 52 53 55
Measurement K-type, -50oC ~ 1300oC, -58oF ~
Range: 1999oF
K-type, -200oC ~ 1370oC, -328oF ~
2498oF
J-type, -200oC ~ 760oC, -328oF ~
1400oF
High: 0.1oC or 0.2oF, Low: 1oC or
Resolution:
1oF
Basic (0.3% + 1oC) at -50oC ~ 1000oC,
Accuracy: (0.3% + 2oF) at -58oF ~ 1832oF
(0.5% + 1oC) at 1000oC ~
1300oC,
(0.5% + 2oF) at 1832oF ~ 1999oF
(0.1 % + 0.7oC) at -200oC ~
1000oC,
(0.1 % + 1.4oF) at -328oF ~
10000oF
(0.3% + 1oC) at 1000oC ~
1370oC,
(0.3% + 2oF) at 1000oF ~ 2498oF)
T1-T2
(0.1% of T1-T2 reding + 2oC),
(0.3%)
( 0.1% of T1-T2 reading + 4oF)
Temperature 0.15 x (Spec. Accuracy) per oC,
Coefficient: <18oC or > 28oC
0.1 x (Spec. Accuracy) per oC,
<18oC or > 28oC
APPA APPA APPA APPA
General 51 52 53 55

Input: K-type thermocouple Single Dual Single Dual


(J-type optional)

Measurement Rate: 2.5 times per second


10 times per second

Display: 31/2 digit (1999 count) LCD, full


annunciators
Dual 4 digit (9999 count) LCD, full
annunicators

Operating Temperature: 0oC ~ 50oC, 32oF ~ 122oF

Humidity: 0% ~ 80% (0oC ~ 35oC) (32oF ~ 95oF)


0% ~ 60% (35oC ~ 50oC) (95oF ~ 122oF)

Storage Temperature: - 20oC ~ 60oC

Input Protection: 60V DC or 24Vrms AC maximum

Power Requirements:
9V battery, NADA 1604, IEC 6F22, JlS
006P
Battery Life: In Hours (Alkaline) 250 250 90 90
Dimensions: 160mm(L)x64mm(W)x26mm(D),
without holster
170mm(L)x74mm(W)x39mm(D), with
holster
Weight: 300 grams without holster
430 grams with holster
Included with instrument:
Type 50BK bead thermocouple, ZnC battery
(installed),
Protective holster, belt clip and manual.