TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-1)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 16.70% Original Wt., gms: 280.2
Fineness Modulus : Oven Dry Wt., gms: 240.1
Wash O.D. Wt., gms: 170.3

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 240.10 100.00 0.00
1" 25 0.0 240.10 100.00 0.00
3/4" 19 0.0 240.10 100.00 0.00
1/2" 12.5 0.0 240.10 100.00 0.00
3/8" 9.5 7.4 232.70 96.92 3.08
#4 4.75 15.2 217.50 90.59 9.41
#10 2 40.7 176.80 73.64 26.36
#40 0.425 55.5 121.30 50.52 49.48
#200 0.075 51.2 70.10 29.20 70.80
PAN 0.3
WASH LOSS 69.8
TOTAL 240.1

D50 = 0.3890
US STANDARD SIEVE SIZE REMARKS:
100.00
90.00 SIEVE SIZE
% PASSING
NO. MM.
80.00
4 4.75 90.6
70.00
10 2.00 73.6
60.00 40 0.425 50.5
50.00 200 0.075 29.2
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty SAND with few
Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-2)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 11.72% Original Wt., gms: 320.2
Fineness Modulus : Oven Dry Wt., gms: 286.6
Wash O.D. Wt., gms: 279.8

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 286.60 100.00 0.00
1" 25 0.0 286.60 100.00 0.00
3/4" 19 0.0 286.60 100.00 0.00
1/2" 12.5 5.2 281.40 98.19 1.81
3/8" 9.5 23.2 258.20 90.09 9.91
#4 4.75 50.2 208.00 72.58 27.42
#10 2 35.0 173.00 60.36 39.64
#40 0.425 78.9 94.10 32.83 67.17
#200 0.075 86.9 7.20 2.51 97.49
PAN 0.4
WASH LOSS 6.8
TOTAL 286.6

CU= 17.78
US STANDARD SIEVE SIZE REMARKS: CC= 0.62
100.00 D50 = 1.1749
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 72.6
70.00
10 2.00 60.4
60.00 40 0.425 32.8
50.00 200 0.075 2.5
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00 Poorly Graded SAND
Soil Description:
1000 100 10 1 0.1 0.01 0.001 with little amount of
Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-5)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 14.22% Original Wt., gms: 366.2
Fineness Modulus : Oven Dry Wt., gms: 320.6
Wash O.D. Wt., gms: 309.5

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 320.60 100.00 0.00
1" 25 0.0 320.60 100.00 0.00
3/4" 19 0.0 320.60 100.00 0.00
1/2" 12.5 10.2 310.40 96.82 3.18
3/8" 9.5 25.5 284.90 88.86 11.14
#4 4.75 39.6 245.30 76.51 23.49
#10 2 41.1 204.20 63.69 36.31
#40 0.425 86.2 118.00 36.81 63.19
#200 0.075 106.6 11.40 3.56 96.44
PAN 0.3
WASH LOSS 11.1
TOTAL 320.6

CU= 14.45
US STANDARD SIEVE SIZE REMARKS: CC= 0.52
100.00 D50 = 0.9120
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 76.5
70.00
10 2.00 63.7
60.00 40 0.425 36.8
50.00 200 0.075 3.6
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00 Poorly Graded SAND
Soil Description:
1000 100 10 1 0.1 0.01 0.001 with little amount of
Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-6)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 17.12% Original Wt., gms: 260.6
Fineness Modulus : Oven Dry Wt., gms: 222.5
Wash O.D. Wt., gms: 165.8

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 222.50 100.00 0.00
1" 25 0.0 222.50 100.00 0.00
3/4" 19 0.0 222.50 100.00 0.00
1/2" 12.5 0.0 222.50 100.00 0.00
3/8" 9.5 0.0 222.50 100.00 0.00
#4 4.75 0.0 222.50 100.00 0.00
#10 2 55.2 167.30 75.19 24.81
#40 0.425 61.2 106.10 47.69 52.31
#200 0.075 49.0 57.10 25.66 74.34
PAN 0.4
WASH LOSS 56.7
TOTAL 222.5

D50 = 0.4898
US STANDARD SIEVE SIZE REMARKS:
100.00
90.00 SIEVE SIZE
% PASSING
NO. MM.
80.00
4 4.75 100.0
70.00
10 2.00 75.2
60.00 40 0.425 47.7
50.00 200 0.075 25.7
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Silty SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-10)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 13.32% Original Wt., gms: 333.6
Fineness Modulus : Oven Dry Wt., gms: 294.4
Wash O.D. Wt., gms: 210.5

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 294.40 100.00 0.00
1" 25 0.0 294.40 100.00 0.00
3/4" 19 0.0 294.40 100.00 0.00
1/2" 12.5 0.0 294.40 100.00 0.00
3/8" 9.5 0.0 294.40 100.00 0.00
#4 4.75 0.0 294.40 100.00 0.00
#10 2 40.0 254.40 86.41 13.59
#40 0.425 79.6 174.80 59.38 40.63
#200 0.075 90.6 84.20 28.60 71.40
PAN 0.3
WASH LOSS 83.9
TOTAL 294.4

US STANDARD SIEVE SIZE REMARKS: D50 = 0.2512


100.00
90.00 SIEVE SIZE
% PASSING
NO. MM.
80.00
4 4.75 100.0
70.00
10 2.00 86.4
60.00 40 0.425 59.4
50.00 200 0.075 28.6
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Silty SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-11)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 7.62% Original Wt., gms: 388.5
Fineness Modulus : Oven Dry Wt., gms: 361.0
Wash O.D. Wt., gms: 277.3

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 361.00 100.00 0.00
1" 25 0.0 361.00 100.00 0.00
3/4" 19 0.0 361.00 100.00 0.00
1/2" 12.5 50.2 310.80 86.09 13.91
3/8" 9.5 80.5 230.30 63.80 36.20
#4 4.75 71.8 158.50 43.91 56.09
#10 2 33.9 124.60 34.52 65.48
#40 0.425 13.2 111.40 30.86 69.14
#200 0.075 27.3 84.10 23.30 76.70
PAN 0.4
WASH LOSS 83.7
TOTAL 361.0

US STANDARD SIEVE SIZE REMARKS: D50 = 6.0256


100.00
90.00 SIEVE SIZE
% PASSING
NO. MM.
80.00
4 4.75 43.9
70.00
10 2.00 34.5
60.00 40 0.425 30.9
50.00 200 0.075 23.3
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: GM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty GRAVEL with
Sand

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-14)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 8.43% Original Wt., gms: 411.6
Fineness Modulus : Oven Dry Wt., gms: 379.6
Wash O.D. Wt., gms: 305.5

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 379.60 100.00 0.00
1" 25 0.0 379.60 100.00 0.00
3/4" 19 0.0 379.60 100.00 0.00
1/2" 12.5 68.5 311.10 81.95 18.05
3/8" 9.5 94.5 216.60 57.06 42.94
#4 4.75 75.2 141.40 37.25 62.75
#10 2 40.2 101.20 26.66 73.34
#40 0.425 8.5 92.70 24.42 75.58
#200 0.075 18.5 74.20 19.55 80.45
PAN 0.1
WASH LOSS 74.1
TOTAL 379.6

US STANDARD SIEVE SIZE REMARKS: D50 = 8.1283


100.00
90.00 SIEVE SIZE
% PASSING
NO. MM.
80.00
4 4.75 37.2
70.00
10 2.00 26.7
60.00 40 0.425 24.4
50.00 200 0.075 19.5
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: GM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty GRAVEL with
Sand

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-15)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 11.00% Original Wt., gms: 277.5
Fineness Modulus : Oven Dry Wt., gms: 250.0
Wash O.D. Wt., gms: 243.9

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 250.00 100.00 0.00
1" 25 0.0 250.00 100.00 0.00
3/4" 19 0.0 250.00 100.00 0.00
1/2" 12.5 0.0 250.00 100.00 0.00
3/8" 9.5 0.0 250.00 100.00 0.00
#4 4.75 0.0 250.00 100.00 0.00
#10 2 55.6 194.40 77.76 22.24
#40 0.425 89.6 104.80 41.92 58.08
#200 0.075 98.6 6.20 2.48 97.52
PAN 0.1
WASH LOSS 6.1
TOTAL 250.0

CU= 9.77
US STANDARD SIEVE SIZE REMARKS: CC= 0.59
100.00 D50 = 0.6310
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 77.8
60.00 40 0.425 41.9
50.00 200 0.075 2.5
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Poorly Graded SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-1 : SS-20)
Sampled at: Jobsite 5-25-15/5-26-15
DATE DRILLED

Sampled by: L. Rebaya / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 12.14% Original Wt., gms: 296.6
Fineness Modulus : Oven Dry Wt., gms: 264.5
Wash O.D. Wt., gms: 260.0

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 264.50 100.00 0.00
1" 25 0.0 264.50 100.00 0.00
3/4" 19 0.0 264.50 100.00 0.00
1/2" 12.5 0.0 264.50 100.00 0.00
3/8" 9.5 0.0 264.50 100.00 0.00
#4 4.75 0.0 264.50 100.00 0.00
#10 2 61.2 203.30 76.86 23.14
#40 0.425 97.5 105.80 40.00 60.00
#200 0.075 101.1 4.70 1.78 98.22
PAN 0.2
WASH LOSS 4.5
TOTAL 264.5

CU= 9.77
US STANDARD SIEVE SIZE REMARKS: CC= 0.65
100.00 D50 = 0.6457
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 76.9
60.00 40 0.425 40.0
50.00 200 0.075 1.8
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Poorly Graded SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-1)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 16.71% Original Wt., gms: 216.5
Fineness Modulus : Oven Dry Wt., gms: 185.5
Wash O.D. Wt., gms: 143.7

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 185.50 100.00 0.00
1" 25 0.0 185.50 100.00 0.00
3/4" 19 0.0 185.50 100.00 0.00
1/2" 12.5 0.0 185.50 100.00 0.00
3/8" 9.5 10.6 174.90 94.29 5.71
#4 4.75 7.0 167.90 90.51 9.49
#10 2 31.0 136.90 73.80 26.20
#40 0.425 50.0 86.90 46.85 53.15
#200 0.075 44.8 42.10 22.70 77.30
PAN 0.3
WASH LOSS 41.8
TOTAL 185.5

US STANDARD SIEVE SIZE REMARKS: D50 = 0.5370


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 90.5
70.00
10 2.00 73.8
60.00 40 0.425 46.8
50.00 200 0.075 22.7
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty SAND with few
Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-2)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 20.04% Original Wt., gms: 278.5
Fineness Modulus : Oven Dry Wt., gms: 232.0
Wash O.D. Wt., gms: 200.0

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 232.00 100.00 0.00
1" 25 0.0 232.00 100.00 0.00
3/4" 19 0.0 232.00 100.00 0.00
1/2" 12.5 0.0 232.00 100.00 0.00
3/8" 9.5 14.2 217.80 93.88 6.12
#4 4.75 8.5 209.30 90.22 9.78
#10 2 40.2 169.10 72.89 27.11
#40 0.425 66.0 103.10 44.44 55.56
#200 0.075 71.0 32.10 13.84 86.16
PAN 0.1
WASH LOSS 32.0
TOTAL 232.0

US STANDARD SIEVE SIZE REMARKS: D50 = 0.5888


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 90.2
70.00
10 2.00 72.9
60.00 40 0.425 44.4
50.00 200 0.075 13.8
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty SAND with few
Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-3)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 10.03% Original Wt., gms: 344.4
Fineness Modulus : Oven Dry Wt., gms: 313.0
Wash O.D. Wt., gms: 310.1

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 313.00 100.00 0.00
1" 25 0.0 313.00 100.00 0.00
3/4" 19 0.0 313.00 100.00 0.00
1/2" 12.5 10.2 302.80 96.74 3.26
3/8" 9.5 5.2 297.60 95.08 4.92
#4 4.75 8.6 289.00 92.33 7.67
#10 2 66.0 223.00 71.25 28.75
#40 0.425 95.2 127.80 40.83 59.17
#200 0.075 124.5 3.30 1.05 98.95
PAN 0.4
WASH LOSS 2.9
TOTAL 313.0

CU= 10.00
US STANDARD SIEVE SIZE REMARKS: CC= 0.55
100.00 D50 = 0.7079
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 92.3
70.00
10 2.00 71.2
60.00 40 0.425 40.8
50.00 200 0.075 1.1
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Poorly Graded SAND
with few Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-4)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 14.59% Original Wt., gms: 389.6
Fineness Modulus : Oven Dry Wt., gms: 340.0
Wash O.D. Wt., gms: 331.6

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 340.00 100.00 0.00
1" 25 0.0 340.00 100.00 0.00
3/4" 19 0.0 340.00 100.00 0.00
1/2" 12.5 25.0 315.00 92.65 7.35
3/8" 9.5 4.1 310.90 91.44 8.56
#4 4.75 1.8 309.10 90.91 9.09
#10 2 70.5 238.60 70.18 29.82
#40 0.425 99.6 139.00 40.88 59.12
#200 0.075 130.0 9.00 2.65 97.35
PAN 0.6
WASH LOSS 8.4
TOTAL 340.0

CU= 12.02
US STANDARD SIEVE SIZE REMARKS: CC= 0.55
100.00 D50 = 0.7079
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 90.9
70.00
10 2.00 70.2
60.00 40 0.425 40.9
50.00 200 0.075 2.6
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Poorly Graded SAND
with few Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-5)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 21.62% Original Wt., gms: 217.1
Fineness Modulus : Oven Dry Wt., gms: 178.5
Wash O.D. Wt., gms: 146.6

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 178.50 100.00 0.00
1" 25 0.0 178.50 100.00 0.00
3/4" 19 0.0 178.50 100.00 0.00
1/2" 12.5 0.0 178.50 100.00 0.00
3/8" 9.5 0.0 178.50 100.00 0.00
#4 4.75 0.0 178.50 100.00 0.00
#10 2 0.0 178.50 100.00 0.00
#40 0.425 34.4 144.10 80.73 19.27
#200 0.075 111.1 33.00 18.49 81.51
PAN 1.1
WASH LOSS 31.9
TOTAL 178.5

US STANDARD SIEVE SIZE REMARKS: D50 = 0.1698


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 100.0
60.00 40 0.425 80.7
50.00 200 0.075 18.5
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Silty SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-6)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 19.62% Original Wt., gms: 255.5
Fineness Modulus : Oven Dry Wt., gms: 213.6
Wash O.D. Wt., gms: 170.5

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 213.60 100.00 0.00
1" 25 0.0 213.60 100.00 0.00
3/4" 19 0.0 213.60 100.00 0.00
1/2" 12.5 0.0 213.60 100.00 0.00
3/8" 9.5 0.0 213.60 100.00 0.00
#4 4.75 0.0 213.60 100.00 0.00
#10 2 0.0 213.60 100.00 0.00
#40 0.425 38.5 175.10 81.98 18.02
#200 0.075 130.5 44.60 20.88 79.12
PAN 1.5
WASH LOSS 43.1
TOTAL 213.6

US STANDARD SIEVE SIZE REMARKS: D50 = 0.1622


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 100.0
60.00 40 0.425 82.0
50.00 200 0.075 20.9
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Silty SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-7)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 5.93% Original Wt., gms: 444.5
Fineness Modulus : Oven Dry Wt., gms: 419.6
Wash O.D. Wt., gms: 328.7

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 419.60 100.00 0.00
1" 25 0.0 419.60 100.00 0.00
3/4" 19 7.4 412.20 98.24 1.76
1/2" 12.5 67.5 344.70 82.15 17.85
3/8" 9.5 80.5 264.20 62.96 37.04
#4 4.75 106.6 157.60 37.56 62.44
#10 2 17.4 140.20 33.41 66.59
#40 0.425 3.8 136.40 32.51 67.49
#200 0.075 44.0 92.40 22.02 77.98
PAN 1.5
WASH LOSS 90.9
TOTAL 419.6

US STANDARD SIEVE SIZE REMARKS: D50 = 7.5858


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 37.6
70.00
10 2.00 33.4
60.00 40 0.425 32.5
50.00 200 0.075 22.0
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: GM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty GRAVEL with
Sand

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-8)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 21.75% Original Wt., gms: 290.5
Fineness Modulus : Oven Dry Wt., gms: 238.6
Wash O.D. Wt., gms: 164.9

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 238.60 100.00 0.00
1" 25 0.0 238.60 100.00 0.00
3/4" 19 0.0 238.60 100.00 0.00
1/2" 12.5 0.0 238.60 100.00 0.00
3/8" 9.5 0.0 238.60 100.00 0.00
#4 4.75 0.0 238.60 100.00 0.00
#10 2 0.0 238.60 100.00 0.00
#40 0.425 40.2 198.40 83.15 16.85
#200 0.075 122.8 75.60 31.68 68.32
PAN 1.9
WASH LOSS 73.7
TOTAL 238.6

US STANDARD SIEVE SIZE REMARKS: D50 = 0.1445


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 100.0
60.00 40 0.425 83.2
50.00 200 0.075 31.7
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SM
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Silty SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-9)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 15.84% Original Wt., gms: 311.5
Fineness Modulus : Oven Dry Wt., gms: 268.9
Wash O.D. Wt., gms: 263.0

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 268.90 100.00 0.00
1" 25 0.0 268.90 100.00 0.00
3/4" 19 0.0 268.90 100.00 0.00
1/2" 12.5 0.0 268.90 100.00 0.00
3/8" 9.5 0.0 268.90 100.00 0.00
#4 4.75 0.0 268.90 100.00 0.00
#10 2 0.0 268.90 100.00 0.00
#40 0.425 28.5 240.40 89.40 10.60
#200 0.075 233.1 7.30 2.71 97.29
PAN 1.4
WASH LOSS 5.9
TOTAL 268.9

CU= 2.29
US STANDARD SIEVE SIZE REMARKS: CC= 0.91
100.00 D50 = 0.1778
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 100.0
60.00 40 0.425 89.4
50.00 200 0.075 2.7
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Poorly Graded SAND

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-10)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 11.03% Original Wt., gms: 377.5
Fineness Modulus : Oven Dry Wt., gms: 340.0
Wash O.D. Wt., gms: 331.5

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 340.00 100.00 0.00
1" 25 0.0 340.00 100.00 0.00
3/4" 19 0.0 340.00 100.00 0.00
1/2" 12.5 0.0 340.00 100.00 0.00
3/8" 9.5 13.2 326.80 96.12 3.88
#4 4.75 20.0 306.80 90.24 9.76
#10 2 70.0 236.80 69.65 30.35
#40 0.425 97.6 139.20 40.94 59.06
#200 0.075 130.2 9.00 2.65 97.35
PAN 0.5
WASH LOSS 8.5
TOTAL 340.0

CU= 10.96
US STANDARD SIEVE SIZE REMARKS: CC= 0.50
100.00 D50 = 0.6918
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 90.2
70.00
10 2.00 69.6
60.00 40 0.425 40.9
50.00 200 0.075 2.6
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Poorly Graded SAND
with few Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-11)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 6.66% Original Wt., gms: 480.5
Fineness Modulus : Oven Dry Wt., gms: 450.5
Wash O.D. Wt., gms: 358.6

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 450.50 100.00 0.00
1" 25 0.0 450.50 100.00 0.00
3/4" 19 17.5 433.00 96.12 3.88
1/2" 12.5 85.2 347.80 77.20 22.80
3/8" 9.5 71.0 276.80 61.44 38.56
#4 4.75 110.0 166.80 37.03 62.97
#10 2 16.2 150.60 33.43 66.57
#40 0.425 18.5 132.10 29.32 70.68
#200 0.075 39.6 92.50 20.53 79.47
PAN 0.6
WASH LOSS 91.9
TOTAL 450.5

US STANDARD SIEVE SIZE REMARKS: D50 = 6.9183


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 37.0
70.00
10 2.00 33.4
60.00 40 0.425 29.3
50.00 200 0.075 20.5
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: GM
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Silty GRAVEL with
Sand

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-13)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 39.59% Original Wt., gms: 170.3
Fineness Modulus : Oven Dry Wt., gms: 122.0
Wash O.D. Wt., gms: 11.2

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 122.00 100.00 0.00
1" 25 0.0 122.00 100.00 0.00
3/4" 19 0.0 122.00 100.00 0.00
1/2" 12.5 0.0 122.00 100.00 0.00
3/8" 9.5 0.0 122.00 100.00 0.00
#4 4.75 0.0 122.00 100.00 0.00
#10 2 0.0 122.00 100.00 0.00
#40 0.425 1.1 120.90 99.10 0.90
#200 0.075 10.0 110.90 90.90 9.10
PAN 0.1
WASH LOSS 110.8
TOTAL 122.0

US STANDARD SIEVE SIZE REMARKS:


100.00
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 100.0
60.00 40 0.425 99.1
50.00 200 0.075 90.9
40.00
30.00 Liquid Limit: 68.2
Plastic Limit: 32.9
20.00
Plasticity Index: 35.3
10.00
Group Symbols: CH
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Silty CLAY

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-10)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 11.03% Original Wt., gms: 377.5
Fineness Modulus : Oven Dry Wt., gms: 340.0
Wash O.D. Wt., gms: 331.5

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 340.00 100.00 0.00
1" 25 0.0 340.00 100.00 0.00
3/4" 19 0.0 340.00 100.00 0.00
1/2" 12.5 0.0 340.00 100.00 0.00
3/8" 9.5 13.2 326.80 96.12 3.88
#4 4.75 20.0 306.80 90.24 9.76
#10 2 70.0 236.80 69.65 30.35
#40 0.425 97.6 139.20 40.94 59.06
#200 0.075 130.2 9.00 2.65 97.35
PAN 0.5
WASH LOSS 8.5
TOTAL 340.0

CU= 10.96
US STANDARD SIEVE SIZE REMARKS: CC= 0.50
100.00 D50 = 0.6457
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 90.2
70.00
10 2.00 69.6
60.00 40 0.425 40.9
50.00 200 0.075 2.6
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
1000 100 10 1 0.1 0.01 0.001
Soil Description: Poorly Graded SAND
with few Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-15)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 7.60% Original Wt., gms: 311.6
Fineness Modulus : Oven Dry Wt., gms: 289.6
Wash O.D. Wt., gms: 264.7

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 289.60 100.00 0.00
1" 25 0.0 289.60 100.00 0.00
3/4" 19 0.0 289.60 100.00 0.00
1/2" 12.5 0.0 289.60 100.00 0.00
3/8" 9.5 21.0 268.60 92.75 7.25
#4 4.75 5.0 263.60 91.02 8.98
#10 2 64.2 199.40 68.85 31.15
#40 0.425 75.5 123.90 42.78 57.22
#200 0.075 98.6 25.30 8.74 91.26
PAN 0.4
WASH LOSS 24.9
TOTAL 289.6

CU= 15.14
US STANDARD SIEVE SIZE REMARKS: CC= 0.48
100.00 D50 = 0.6457
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 91.0
70.00
10 2.00 68.9
60.00 40 0.425 42.8
50.00 200 0.075 8.7
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP-SM
0.00 Poorly Graded SAND
Soil Description:
1000 100 10 1 0.1 0.01 0.001 with Silt with few
Gravel

Remarks: This report is the result of test performed on the sample taken from site.
TERMS Concrete & Materials
Testing Laboratory Inc. DPWHBRSAccredited
#19 L. Intalan St., Bagong Ilog, Pasig City.
Laboratory

TEST REPORT FOR SIEVE ANALYSIS


ASTM D - 422
Name of Project: CONST. OF RIVERWALL
Kind of Sample: Soil (BH-2 : SS-16)
Sampled at: Jobsite 5-16-15/5-20-15
DATE DRILLED

Sampled by: R. Congues / Driller TCT 6/1/2015


OFFICE DATE RECEIVE

Tested by: K. Co & S. Gil / Laboratory Technician TCT 6-1-15/6-4-15


OFFICE DATE TEST

Spec's. Item No. : Laboratory No.:


Nat. Moisture Content, % : 10.35% Original Wt., gms: 297.5
Fineness Modulus : Oven Dry Wt., gms: 269.6
Wash O.D. Wt., gms: 266.8

SIEVE SIZE CUMULATIVE


WIEGHT WT.
SPEC'S REMARKS
INCH / NO. MM. RETAINED PASSING % PASSING% RETAINED
gms gms
1-1/2" 37.5 0.0 269.60 100.00 0.00
1" 25 0.0 269.60 100.00 0.00
3/4" 19 0.0 269.60 100.00 0.00
1/2" 12.5 0.0 269.60 100.00 0.00
3/8" 9.5 0.0 269.60 100.00 0.00
#4 4.75 0.0 269.60 100.00 0.00
#10 2 85.5 184.10 68.29 31.71
#40 0.425 80.2 103.90 38.54 61.46
#200 0.075 100.6 3.30 1.22 98.78
PAN 0.5
WASH LOSS 2.8
TOTAL 269.6

CU= 13.49
US STANDARD SIEVE SIZE REMARKS: CC= 0.56
100.00 D50 = 0.7586
90.00 SIEVE SIZE
% PASSING
80.00
NO. MM.
4 4.75 100.0
70.00
10 2.00 68.3
60.00 40 0.425 38.5
50.00 200 0.075 1.2
40.00
30.00 Liquid Limit: -
Plastic Limit: NP
20.00
Plasticity Index: -
10.00
Group Symbols: SP
0.00
Soil Description:
1000 100 10 1 0.1 0.01 0.001 Poorly Graded SAND

Remarks: This report is the result of test performed on the sample taken from site.