Vous êtes sur la page 1sur 6

SUBMITTAL DATA SHEET

SPLIT-SYSTEM AIR CONDITIONING CONDENSING UNITS


7.5 - 25 TONS
MODELS: YC090 thru 300, 2-PIPE
YD120 thru 240, 4-PIPE

JOB NAME: LOCATION:

PURCHASER: ORDER NO:

ENGINEER:
SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION:

SUBMITTED BY: DATE:

UNIT DESIGNATION: SCHEDULE NO. MODEL NO.

FEATURES
_

COOLING PERFORMANCE
EXCEEDS ASHRAE 90.1-2004 / MEETS EPACT 2010 EFFICIENCY*
TOTAL CAPACITY- - - - - - - - - - - - - - _____ MBH SIMPLICITY CONTROLS
OUTDOOR DESIGN TMP. - - - - - - - - - - _____ F R-410A REFRIGERANT
POWDER PAINT FOR DURABILITY
SUCTION PRESSURE AT WEATHERIZED CASING FOR OUTDOOR USE
SATURATION - - - - - - - - - - - - - - - - - _____ PSIG PROPELLER-TYPE CONDENSER FANS
SUCTION TEMPERATURE AT INHERENTLY PROTECTED FAN MOTORS
HIGH AND LOW PRESSURE SAFETIES
SATURATION - - - - - - - - - - - - - - - - - - - _____ F
SCROLL COMPRESSORS
ELECTRICAL DATA CRANKCASE HEATERS
ALUMINUM TUBE/ALUMINUM FIN MICROCHANNEL COILS
POWER SUPPLY - - - - - - - - - _____/_____/_____ BACKSEATING SUCTION AND LIQUID LINE SERVICE VALVES
SINGLE AND DUAL REFRIGERATION CIRCUITS
TOTAL UNIT AMPACITY - - - - - - - - _____ AMPS (SINGLE ON YC AND DUAL ON YD MODELS)
POWER INPUT REQ. - - - - - - - - - - - - - _____ KW LOW AMBIENT TO 40F - LOW AMBIENT AVAILABLE TO 0F
PROVISIONS FOR HOT GAS BYPASS
MINIMUM WIRE SIZE - - - - - - - - - - - - _____ AWG CSA APPROVAL
(COPPER CONDUCTORS) ONE YEAR LIMITED PARTS WARRANTY ON COMPLETE UNIT
MAXIMUM FUSE SIZE - - - - - - - - - - _____ AMPS FIVE YEAR LIMITED COMPRESSOR WARRANTY
LIQUID LINE DRIERS (SUPPLIED FOR FIELD INSTALLATION)
(DUAL ELEMENT)
FACTORY INSTALLED DISCONNECT OPTION
UNIT WEIGHT FACTORY INSTALLED POWERED OR NON-POWERED 120V OUT-
LET OPTION
TOTAL OPERATING WEIGHT - - - - - _____ LBS FULL PERIMETER BASE RAIL-FORK TRUCK ACCESSIBLE
CRANE RIGGING PROVISIONS

*WHEN COUPLED WITH MATCHING INDOOR UNIT

YC090, YC120, YD120, YC180, YD180,


YC150, YD150 YC240, YD240, YC300

Johnson Controls Unitary Products 506413-YSD-C-1010


506413-YSD-C-1010

WEIGHT DISTRIBUTION

CORNER WEIGHTS & CENTER OF GRAVITY


Size Weight (lbs.) Center of Gravity (in.) 4 Point Load Location (lbs.)
Model
(Tons) Shipping Operating X Y A B C D
090
YC090 390 387 17 32.3 99 113 94 82
(7.5)
120 YC120 499 497 17.3 32.3 124 147 122 103
(10) YD120 493 490 17.4 32.5 123 147 120 100
150 YC150 499 497 17 32.3 127 145 120 105
(12.5) YD150 493 490 17.4 32.5 123 147 120 100
180 YC180 914 909 32.5 31.5 239 246 215 209
(15) YD180 899 894 32.5 31.5 235 242 212 206
240 YC240 945 942 30.3 31.0 261 234 212 236
(20) YD240 930 927 32.7 31.8 244 255 218 210
300
YC300 945 942 30.3 31.0 261 234 212 236
(25)

LEFT

D A

LEFT

DIM X
D A
DIM X CG
CG
FRONT REAR FRONT REAR

WIDTH

C B
WIDTH
DIM Y

LENGTH

RIGHT C B
YC090, YC120, YD120,
YC150, YD150 DIM Y

LENGTH

RIGHT

YC180, YD180,
YC240, YD240,
YC300

2 Johnson Controls Unitary Products


506413-YSD-C-1010

UNIT DIMENSIONS

YC090, YC/YD120, YC/YD150


RIGHT

REAR FRONT

LEFT

CONVENIENCE
OUTLET

2X ( 1.375)
KNOCKOUT
30.994

2X ( 0.875)
KNOCKOUT

12.126
9.876
4.751

3.883
7.000 10.000 7.000 7.000 23.000 7.000
3.664
37.000
24.000 2.933
31.758 1.664
58.500
FRONT RIGHT

SYSTEM 2

2X ( 0.875)
KNOCKOUT

2X ( 1.375)
KNOCKOUT
15.53
12.70 12.000
SYSTEM 1 10.000
4.875

6.26
4.132
7.52
8.98 2.382
REAR 10.60 LEFT 1.882

*See UNIT HEIGHT DIMENSIONS, PIPING AND ELECTRICAL CONNECTIONS SIZES (next page)

Johnson Controls Unitary Products 3


506413-YSD-C-1010

UNIT HEIGHT DIMENSIONS (INCHES) PIPING AND ELECTRICAL CONNECTIONS SIZES


MODEL A (INCHES)
YC090 44.5 MODEL YC090 YC120 YD120 YC150 YD150

YC120 50.0 No. Refrigeration Circuits 1 1 2 1 2

YD120 50.0 Suction Line OD (in.) 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8

YC150 50.0 Liquid Line OD (in.) 5/8 7/8 5/8 7/8 5/8

YD150 50.0 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8

4 Johnson Controls Unitary Products


506413-YSD-C-1010

UNIT DIMENSIONS

YC/YD180, YC/YD240 & YC300

REAR

LEFT RIGHT

FRONT

A
SYSTEM 2

SYSTEM 1
2X ( 1.375)
30.994 KNOCKOUT

2X ( 0.875)
KNOCKOUT
11.375
9.125
4.750

7.000 23.000 7.000 4.132


7.000 23.000 7.000
3.913
37.000 37.000
3.181
64.000 1.913
59.000

FRONT RIGHT

SYSTEM 2

SYSTEM 1

16.133
13.133

17.367
18.867
20.617
22.617
FRONT
(PIPING DETAIL)

*See UNIT HEIGHT DIMENSIONS, PIPING AND ELECTRICAL CONNECTIONS SIZES (next page)

Johnson Controls Unitary Products 5


UNIT HEIGHT DIMENSIONS (INCHES) PIPING AND ELECTRICAL CONNECTIONS SIZES
MODEL A (INCHES)
YC180 44.5 MODEL YC180 YD180 YC240 YD240 YC300

YD180 44.5 No. Refrigeration Circuits 1 2 1 2 1

YC240 50.0 Suction Line OD (in.) 1 5/8 1 3/8 1 5/8 1 3/8 1 5/8

YD240 50.0 Liquid Line OD (in.) 7/8 5/8 7/8 5/8 7/8

YC300 50.0 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8

MINIMUM CLEARANCES
CLEARANCE DESCRIPTION DISTANCE IN INCHES

Overhead (Top) 120


Front 36
Rear 36
Left Side 30
Right Side 30
1 0
Bottom

1. In all installations where snow accumulates and winter opera-


tion is expected, additional height must be provided to insure
normal condenser airflow.

FACTORY-INSTALLED OPTIONS FIELD-INSTALLED ACCESSORIES


DISCONNECT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
NON-POWERED CONV. OUTLET - - - - - - - - - - - - - - - - HAIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
POWERED CONV. OUTLET - - - - - - - - - - - - - - - - - - - - LOW AMBIENT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - -
PHASE MONITOR - - - - - - - - - - - - - - - - - - - - - - - - - - - HOT GAS BYPASS KIT- - - - - - - - - - - - - - - - - - - - - - - -
COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
LOW AMBIENT TO 0 - - - - - - - - - - - - - - - - - - - - - - - - - MATCHING AIR SIDE EQUIPMENT DATA
TECHNICOATED COIL - - - - - - - - - - - - - - - - - - - - - - - -
MODEL NUMBER _______________________________
SUBMITTAL FORM NUMBER ______________________

REFER TO UNIT TECHNICAL GUIDE FOR THE LIST OF STANDARD FEATURES


ATTACHED NOT ATTACHED

NOTES:
____________________________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________
____________________________________________________________________________________________________

Subject to change without notice. Printed in U.S.A. 506413-YSD-C-1010


Copyright 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 506413-YSD-B-0310

Johnson Controls Unitary Products


5005 York Drive
Norman, OK 73069

Vous aimerez peut-être aussi