Ericsson Command Handling

1. Giving Performance test against a TRX

rxbli:mo=rxotrx-395-5; (Block)
rxtei:mo=rxotrx-395-5; (Perf. Test)
rxble:mo=rxotrx-395-5; (Deblock)

2. To see the frequency state of a TRX(With fault code)

rxmfp:mo=rxotrx-395-5;

3. To see TRX status

1. rxmsp:mo=rxotrx-395-5; (For having only one TRX status)


2. rxmsp:mo=rxotrx-395-4&&-5; (for having two or more TRX status

4. To see all (TX,TS,TRX) status

rxmsp:mo=rxotrx-395-5,subord;

Note: State, BLO, BLA all the values will be zero for active TRX (TRX in good condition)

5. To find the TG value of a Site

rxtcp:moty=rxotg , cell=dx03214;

6. To see all external alarm of a BSC

allip:alcat=bts;

7. To see all internal alarm of a BSC

allip:alcat=sw_dev;

8. To see active alarm of a BSC

allip; (For all the active alarm of a BSC)


allip:acl=a1; (where a1=critical alarm only)
allip:acl=a2; (where a2=major alarm only)
allip:acl=a3; (where a3=minor alarm only)
allip:acl=a1,alcat=ext/bts; (for critical ext alarms)

9. To see the total number of TRX of a Site

rxcdp:mo=rxotg-27,details; (where 27 is the TG value of 900B of a site.)

10. Block-Deblock of a TRX

rxbli:mo=rxotrx-23-0,subord; (Block)
rxese:mo=rxotrx-23-0,subord; (Reload Order)
rxesi:mo=rxotrx-23-0,subord; (Reload Execute)
rxble:mo=rxotrx-23-0,subord;(Deblock)
11. TRX no. of 900B and 1800B

900B Cell 1800B Cell

1 2 3 1 2 3 (No. of Cell)

0 4 8 0 4 8 |
1 5 9 1 5 9 |
2 6 10 2 6 10 | (No.
3 7 11 3 7 11

12. To find out The RBL2,RBLTB,RBLT2 number of a Specific site

a) rxapp:mo=rxotg-353; where 353 is the TG value of a site


b) ntcop:snt=all;

Note: Searching format to find out the Fault description, Action from the PDF file: No of class: fault
code. Example: 1B:33, 2A:30

13. To see the GPRS Status of a BSC

rrgbp;

14. Lock-unlock of a TRX(including all TX,TS etc corresponding the TRX)

rxbli:mo=rxotrx-23-0,subord; (Lock)
rxble:mo=rxotrx-23-0,subord; (Unlock)

15. Lock-unlock of a TRX(excluding all TX,TS etc corresponding the TRX)

rxbli:mo=rxotrx-23-0; (Lock)
rxble:mo=rxotrx-23-0; (Unlock)

16. Lock unlock of a cell

rlstc:cell=dx12341,state=halted; (The first cell lock of DHK_X1234 site)


rlstc:cell=dx12341,state=active; (The first cell unlock of DHK_X1234)
rlstc:cell=dx12341,chgr=1,state=active; (The first cell of 1800 band unlock
of DHK_X1234)

17. To check the RBL2 of a site either it is Working or not (Loop check)

dtstp:dip=84rbl2; (where 84 is the rbl2 number of a site)

18.To check PCMS loop from BSC end of a site

dtstp:dip=84rtltb;

19.To check PCMS loop from TRAU end of a site

dtstp:dip=84rtltt;

20.To know the time from the system

caclp;
21.To find the number of traffic channel of a site

rxapp:mo=rxotg-6; where 6 is the TG value.

22. To get all the signaling of a BSC

c7ltp:ls=all;

23. To clear digital path quality supervisionalarm

dtqsr:dip=all,es;
dtqsr:dip=all,cs2;
dtqsr:dip=all,ses;
dtqsr:dip=all,ses2;
dtqsr:dip=all,sf;

24. To look into either a cell holding call or to see channel status

rlcrp:cell=dx00932;

25. To monitor signaling point

c7spp:sp=all;

27. To know frequency of all BTS in a BSC

1. rlcfp:cell=all; (For all BTS)


2. rlcfp:cell=dx00501; (For a specific cell)

27. To know cell configuration frequency data

rlcfp:cell=dx00931; (Where 1 is for 1st cell of DHK_X0093)

28. To have all the data of a cell

rldep:cell=dx00931;

29. To get either a cell is 900B or 1800B

Lj-l

30. The command to point the connected BSCs for the TRC

rrbsp;

31. The command of getting the name of MSC to which BSC is connected

rrmbp;

32. To have the name of all MSC

rrmbp:msc=all;

33. To see all PCM status

dtstp:dip=all;
34. To see either a cell is halted or active

rlstp:cell=dx00931;

35. To see the halted cell status of all BTS in a BSC

rlstp:cell=all,state=halted;

37. To know all TRX faults

1. rxasp:moty=rxotrx; (for all kinds of OML fault of a BSC)


2. rxasp:moty=rxotg; (For all kinds of Fault of a BSC)

39. To know either a Site carrying 2E1 or 1E1

rxapp:mo=rxotg-6;

Here 6 is the TG value of the site. If no. of TCH starts from 1 to 31 then 2E1. If starts from 1 to 15
then it will be 1E1 carrying site .

36. To get all PCM status which are down

dtstp:dip=all,state=abl;

38. To know individual TRX fault

rxasp:mo=rxotrx-260-0;

Where 260 is TG value & 0 is for TRX number

40. To have the TEI number of a site

rxmop:mo=rxocf-8;

41. To manually block or unblock a specific rbtl2

1. dtble:dip=78rblt2; (Unblock)
2. dtbli:dip=78rblt2; (block)

42. To have the site ID (name of site) from an unknown TG value

rxasp:mo=rxotg-340;

43: To get the software version of a Site

rxmop:mo=rxotg-8;

44. A TRX having hardware or not

rxmfp:mo=rxotrx-8-0;

If RU Version, Position all values show zero then the TRX is without hardware.

45. To check if AP is up
1) aploc;
2) prcstate l
AP is equivalent to BAM. APs are redundant.

46.How to find out RALT2 belongs to which BSC

Lets assume RALT2:49 in TEDHK01


Connect to TEDHK01
ntcop:snt=all;
There will be a DEV list against all DIPs
Against 49RALT2 there will be a range [RALT2-1568&&-1599]
Add 1 with the lower range, which will be 1569 for 49RALT2
racip:dev=RALT2-1569;
The second command will show connected MSC & BSC.

47.To find out under which sector a TRX is


RXMOP:MO=RXOTX-TG-TRX

Elaboration:

TS= Time slot


TX= Transmission of TRX
RX= Receiver of TRX
TG= Transceiver Group
CF= Control Function
TF= Timing Function
IS= Interface SW

Note:

DXU of ericsson site is equivalent to COBA of Siemens

For CDU-G : If TG value is less than 200 then it is 900B else 1800B
For CDU-K : Both bands will have same TG

Sometimes 1800B and 900B are thrown over 1E1 in that case RBLT2 of Both will be same but their
TG value will be different.

If OML fault appears against a TRX or site that means OMC connection is broken for that site or
TRX. So no command will be successful in that case.

One DTRU Contains two TRXs

BTS
!
!------RBLT2
!
BSC
!------RTLTB/RTB/RTB2
!
!------RTLTT/RTT
TRC
!
!------RAL2/RALT2
!
MSC
RAL2/RALT2 equivalent to PCMA
RTLTT/RTT2 equivalent to PCMS
RBL2/RBLT2 equivalent to PCMB

BSC TRC MSC Location


BSCT01 TECTY01 MGCT02 Chittagong
BSCT03 TECTY02 MGCT03 Chittagong
BSCT04 TECTY01 MGCT02 Chittagong
BSDH04 MGDH04 CRP-Mirpur
BSDH06 TEDHE01 MGDH01 Hosna
BSDH17 TEDHK01 MGDH03 Kaderia
BSDH20 TEDHC01 MGDH01 Hosna
BSDH26 TEDHC02 MGDH01 Hosna
BSDH30 TEDHK01 MGDH03 Kaderia

48. To see whether CDU cable is K or G type.


Rxmfp:mo=rxocf-33;

49.To Find out how many ckt are block of a STM( for this command please connected to respective
switch )
Stdsp:dety=rtltt2,bsc=all;

50, To see the trx band(900/1800) here 289 TG value,2b TRX number
RXMOP:MO=RXOTRX-289-2,subord;

51. for circuit measurement:(TRC)


stdsp:dety=rtltt2,bsc=all;

Calculation: NBL/NDV

52. For created but unconfigured TRX Status:

RXMSP:MO = RXOTG-##,SUBORD;
RXESI:MO = RXOTRX-##-##,SUBORD;
RXBLE:MO = RXOTRX-##-##,SUBORD;

53. To find out TG value against a BTS.

Rxtcp:moty=rxotg,cell=dx22661; where dx22661 is cell no.


54. To find out whether is signaling down or not?
Tpcop:sdip=2etm2;

54,
Rrgbp;