Tranter GmbH

DESIGN CALCULATION Hohe-Flum-Strasse 31


D-79650 Schopfheim; Germany
Tranter Order no.:

MAWP and Test Pressure 102260-1


Page 1 of 1

Company Tranter GmbH


Name of the component S & P Heat Exchanger
Drawing no. 300 21 00979
Prepared: Rev.00 12.04.2016 uky
Design according to the ASME Code Section VIII, Div.1, Edition 2015, Addenda --

Design Pressure:
Shellside FV/ 10,00 bar(g)
Plateside FV/ 10,00 bar(g)

MAWP:
Shellside 10,00 bar(g)
Plateside 10,00 bar(g)

MAEWP:
Shellside 1 bar
Plateside 0 bar

Test Pressure PT:


(the lowest value of the formulae listed below)
PT = 1,3 x MAWP x SrT / SdT

Material = SA-516 Grade 70

metric units USA units


MAWP I = 10,00 bar(g) Shellside 145 psi(g)
MAWP II = 11,00 bar(g) Plateside 160 psi(g)
SrT = 138 N/mm at 20 C 20000 psi
SdT = 138 N/mm at 220,0 C 20000 psi

PT = 13,00 bar(g) Shellside (PT = 1,3 x MAWP x SrT / SdT) 189 psi(g)
PT = 14,30 bar(g) Plateside (PT = 1,3 x MAWP x SrT / SdT) 207 psi(g)

Material = SA-312 TP316L

metric units USA units


MAWP I = 10,00 bar(g) Shellside 145 psi(g)
MAWP II = 11,00 bar(g) Plateside 160 psi(g)
SrT = 115,0 N/mm at 20 C 16600 psi
SdT = 103,0 N/mm at 220,0 C 14900 psi

PT = 14,51 bar(g) Shellside (PT = 1,3 x MAWP x SrT / SdT) 210 psi(g)
PT = 15,97 bar(g) Plateside (PT = 1,3 x MAWP x SrT / SdT) 232 psi(g)

PT Shellside = 13,00 bar(g) chosen 17,50 bar(g) 189 psi(g)


PT Plateside = 14,30 bar(g) chosen 17,50 bar(g) 207 psi(g)