Vous êtes sur la page 1sur 4

DD+DIS015.

01E Technical Modifications

Section 11

List of Contents

1 Replacing the new rear cover 3 and the top cover.................................... 1


1.1 Cause CURIX 60......................................................................................................1
1.2 Introduction as production standard ....................................................................1
1.3 Cause CP 1000 ........................................................................................................1
1.4 Introduction as production standard ....................................................................1

2 Modification kit for the strain relief ............................................................ 2


2.1 Cause Curix 60 / CP 1000 .......................................................................................2
2.2 Introduction as production standard ....................................................................2

3 Replacement of the cage cover .................................................................. 2


3.1 Cause CP 1000 ........................................................................................................2
3.2 Introduction as production standard ....................................................................2

4 Replacement of the valves of the replenisher bottles .............................. 3


4.1 Cause.......................................................................................................................3
4.2 Introduction as production standard ....................................................................3

5 Pump mounting with latches, introduced as production standard ......... 3


5.1 Cause.......................................................................................................................3

Edition 2, Revision 0 CURIX 60 / CP 1000 (Type 9462) Section 11 / I


DD+DIS015.01E Technical Modifications

1 Replacing the new rear cover 3 and the top cover

1.1 Cause CURIX 60


While the processor is developing films, undeveloped films which are placed on the dryer
hood are fogged via the IR heaters.
Error symptoms see section 6.3.

1.2 Introduction as production standard


Cover 3 CM+9.9463.1214.0
Top cover CM+9.9462.1185.2
Machine type As of SN
9462/105 2219
9462/155 1031
9462/165 1056

1.3 Cause CP 1000


While the processor is developing films, undeveloped films which are placed on the dryer
hood are fogged via the IR heaters.
Error symptoms see section 6.3.

1.4 Introduction as production standard


Top cover CM+9.9462.1185.2
Machine type As of SN
9462/205 2108
9462/285 1072
9462/305 1311
9462/845 2364

Edition 2, Revision 0 CURIX 60 / CP 1000 (Type 9462) Section 11 / 1


Technical Modifications DD+DIS015.01E

2 Modification kit for the strain relief

2.1 Cause Curix 60 / CP 1000


Due to spilling from the machine tanks, and also in case of careless handling in the area of
the tank heater/machine tank, the chemicals may run along the cables and reach the Control
Board where they can probably cause a short circuit.

2.2 Introduction as production standard


Machine type As of SN
9462/105 2179
9462/155 1026
9462/165 1056
9462/205 2059
9462/285 1072
9462/305 1311
9462/845 2176

3 Replacement of the cage cover

3.1 Cause CP 1000


When handling full machine tanks above the dryer, the chemicals may spill on the Control
Board.

3.2 Introduction as production standard


Closed cage cover CM+9.9463.1471.0
Machine type As of SN
9462/205 2108
9462/285 1072
9462/305 1311
9462/845 2364

Section 11 / 2 CURIX 60 / CP 1000 (Type 9462) Edition 2, Revision 0


DD+DIS015.01E Technical Modifications

4 Replacement of the valves of the replenisher bottles

4.1 Cause
The material of the valves has been affected by photochemicals.

4.2 Introduction as production standard


Valve, complete (developer) CM+9.9432.1070.5
Valve, complete (fixer) CM+9.9432.1110.5
Valve, complete (water) CM+9.9432.1090.5
Machine type As of SN
9462/105 2701
9462/155 -
9462/165 -
9462/205 2108
9462/285 1072
9462/305 1311
9462//845 2394

5 Pump mounting with latches, introduced as production standard

5.1 Cause
The customers do not really accept that they have to open screws in order to clean the
pumps.
Developer pump CM+9.9462.9110.0
Fixer pump CM+9.9462.9120.0
Water pump CM+9.9462.9130.0
Machine type As of SN
9462/105 1881
9462/155 1006
9462/165 1036
9462/205 1803
9462/285 1054
9462/305 1131
9462/845 1716

Edition 2, Revision 0 CURIX 60 / CP 1000 (Type 9462) Section 11 / 3