Académique Documents
Professionnel Documents
Culture Documents
2011
SIFAT FISIK MINYAK SAWIT KASAR DAN KORELASINYA DENGAN ATRIBUT MUTU
[Physical Properties of Crude Palm Oil and Their Correlations to the Quality Attributes]
ABSTRACT
Indonesia is the largest producer and exporter of crude palm oil (CPO) in the world. Process engineering applications of CPO during handling,
transporting, and processing, need baseline data related to CPOs physical properties. This research was aimed to obtain baseline data about
physical properties of CPO and to study the correlation between CPOs quality attributes to their physical property parameters. Study on physical
property and quality of CPO was conducted to five CPO samples from different CPOs producers. Those samples had variations on physical
property parameters and quality attributes. Some physical property parameters of CPO were depended on the temperature of measurements. CPO
samples showed non-Newtonian pseudoplastic behaviour at 25C with various flow behaviour index (n) and concistency index (K), other wise at
55C all CPO samples showed Newtonian behaviour.There were good correlations between quality attributes of CPO to their physical property
parameters at 25C, including correlations between free fatty acid contents of CPO and the temperatures of crystallization, as well as between
iodine values and the rheological properties of CPO.
177
Hasil Penelitian J. Teknol. dan Industri Pangan, Vol. XXII No. 2 Th. 2011
178
Hasil Penelitian J. Teknol. dan Industri Pangan, Vol. XXII No. 2 Th. 2011
diketahui. Data sifat fisik lima sampel CPO yang dikumpulkan Hasil pengujian tersebut agak berbeda dengan data yang di-
dalam penelitian ini terutama yang terkait dengan parameter kemukakan oleh Basiron (2005) untuk sampel RBDPO, dimana
proses yang dialami CPO selama penanganan dan pengolahan, pada suhu 25C, kisaran SFC adalah sebesar 6,5-18,5%, dan
mencakup densitas, SFC, sifat reologi, serta titik kristalisasi dan pada suhu di atas 45C nilai SFC sudah sangat rendah yaitu
titik leleh CPO yang diukur pada suhu 25C (Tabel 1) dan 55C rata-rata 0,7%. Diduga, proses pemurnian yang dialami oleh
(Tabel 2). Pembahasan lebih mendalam mengenai hasil sampel RBDPO mempengaruhi nilai SFC-nya.
pengujian sifat fisik disajikan pada bagian berikut ini. Penurunan SFC yang terjadi saat SFC diukur pada suhu
25C dan 55C terjadi karena pada suhu 55C telah terjadi
Densitas CPO pelelehan pada hampir seluruh lemak yang semula merupakan
Densitas CPO pada suhu 25C (Tabel 1) berkisar antara fase padat menjadi fase cair. Hal ini sangat terkait dengan titik
0,909-0,917 g/mL, sedangkan pada suhu 55C (Tabel 2), nilai leleh (TM) sampel CPO yang berdasarkan Tabel 1 bernilai rata-
densitasnya menurun menjadi berkisar antara 0,888-0,892 rata 39,2C. Berdasarkan ANOVA pada taraf uji 95%, SFC
g/mL. Bila dibandingkan dengan data densitas RBDPO pada kelima sampel CPO baik pada suhu 25C maupun suhu 55C
suhu 50C seperti yang disajikan oleh Ong et al. (1995) yaitu nilainya berbeda nyata antar sampel. Khususnya untuk sampel
sebesar 0,891 g/mL, maka nilai densitas CPO yang dihasilkan CPO C, nilai SFC-nya pada suhu 25C dan 55C paling tinggi
dalam penelitian ini hampir sama. Ong et al. (1995) juga me- dibandingkan sampel CPO lain, yang diperkirakan disebabkan
ngemukakan bahwa suhu berpengaruh pada densitas minyak oleh tingginya kadar kotoran dalam sampel CPO C. Perbedaan
sawit, dimana suhu yang semakin tinggi akan menurunkan nilai nilai SFC pada lima sampel CPO tersebut menurut Basiron
densitasnya. (2005) dipengaruhi oleh proses kristalisasi yang terjadi pada
Hasil pengujian ANOVA pada taraf uji 95% menunjukkan sampel yang ditentukan oleh komposisi kimianya yang berbeda.
bahwa densitas kelima sampel CPO baik pada suhu 25C
maupun 55C, tidak berbeda nyata antar sampel. Dengan Sifat reologi CPO
demikian, walaupun pada beberapa parameter mutu dan sifat Sifat reologi suatu fluida dapat ditentukan melalui per-
fisik CPO terdapat perbedaan yang nyata secara statistik cobaan pengukuran pengaruh shear rate (laju geser) terhadap
(seperti dapat dilihat pada Tabel 1 dan 2), hal tersebut ternyata shear stress (gaya geser) sampel, dan menghasilkan kurva
tidak menyebabkan perbedaan yang nyata pada densitas CPO. rheogram seperti dapat dilihat pada Gambar 1, seperti yang
dijelaskan oleh Steffe dan Daubert (2006). Pada suhu standar
Kandungan lemak padat CPO 25C, bentuk rheogram kelima sampel CPO adalah concave
Kandungan lemak padat (SFC) ditentukan oleh jumlah upwards (cekung ke atas) yang merupakan ciri dari fluida yang
asam lemak yang berada dalam fase padat pada suhu tertentu bersifat non-newtonian pseudoplastic. Pada shear rate yang
setelah melalui tempering suhu tertentu pula. Berdasarkan meningkat, nilainya tidak berbanding lurus dengan kenaikan
Tabel 1 dapat diketahui bahwa pada suhu pengukuran standar shear stress, dan menghasilkan viskositas terukur () yang
25C, SFC sampel CPO berkisar antara 14,55-20,16%. Pada semakin rendah.
suhu 55C (Tabel 2), SFC sampel CPO menurun dibandingkan
saat diukur pada suhu 25C, dengan kisaran SFC 2,09-7,01%.
Tabel 1. Hasil analisis sifat fisik lima sampel CPO pada suhu 25C
Parameter sifat fisik*
Sampel CPO Kandungan Indeks Viskositas terukur
Densitas Indeks tingkah Titik kristalisasi/TC Titik leleh/TM
lemak padat konsistensi aliran pada 400 s-1
(, g/mL) laku aliran (n) (C) (C)
(SFC, %) (K, Pa.sn) (, mPa.s)
CPO A 0,909a 16,64b 0,534b 2,519b 153,3c 23,55a 38,52a
CPO B 0,912a 18,34c 0,781d 0,369 a 98,9b 23,17a 39,16a
CPO C 0,917a 20,16d 0,457a 4,530 c 174,5c 22,47a 39,78a
CPO D 0,917a 14,55a 0,545b 2,452b 159,3c 21,12a 39,53a
CPO E 0,916a 17,23b,c 0,673c 0,380a 53,6a 23,28a 39,19a
Keterangan :
* Huruf yang berbeda di belakang angka pada kolom yang sama menunjukkan perbedaan nyata pada taraf uji 95%
Tabel 2. Hasil analisis sifat fisik lima sampel CPO pada suhu 55C
Parameter sifat fisik*
Sampel CPO Densitas Kandungan lemak padat Indeks tingkah laku aliran Indeks konsistensi aliran Viskositas terukur pada 400 s-1
(, g/mL) (SFC, %) (n) (K, Pa.sn) (, mPa.s)
CPO A 0,891a 4,66b 0,987a 0,027a 25,0a
CPO B 0,888a 4,37b 0,968a 0,027a 22,2a
CPO C 0,892a 7,01c 0,936a 0,031a 21,1a
CPO D 0,890a 4,06b 1,004 a 0,026a 25,7a
CPO E 0,891a 2,09a 0,948 a 0,030a 22,0a
Keterangan :
* Huruf yang berbeda di belakang angka pada kolom yang sama menunjukkan perbedaan nyata pada taraf uji 95%
179
Hasil Penelitian J. Teknol. dan Industri Pangan, Vol. XXII No. 2 Th. 2011
60
relatif tetap berkisar antara 21,1-26,1 mPa.s, jauh lebih rendah
50
dibandingkan pada suhu 25C. Sifat fluida non-newtonian
40
pseudoplastic pada sampel CPO bersuhu 25C diduga disebab-
30 kan adanya kandungan fraksi stearin berbentuk padat dalam
20 CPO. Saat mengalami peningkatan suhu menjadi 55C, fraksi
10 stearin mengalami pelelehan sehingga CPO berada dalam fase
0 cair sempurna, tidak mengalami hambatan pengaliran, dan
0 50 100 150 200 250 300 350 400 menghasilkan sifat fluida newtonian. Menurut Ong et al. (1995),
Shear rate (s -1)
CPO A CPO C CPO E minyak menunjukkan sifat aliran fluida newtonian, namun
CPO B CPO D terdapat indikasi sifat aliran turbulen non-newtonian pada
Gambar 1. Hubungan shear rate dan shear stress atau kurva rheogram RBDPO yang bersuhu di bawah 35C.
lima sampel CPO pada suhu 25C Berdasarkan pengujian ANOVA pada taraf uji 95%, nilai n,
K, dan pada suhu 25C dan shear rate 400 s-1 berbeda nyata
Bentuk rheogram antar sampel CPO berbeda dan dapat antar sampel CPO. Perbedaan sifat reologi kelima sampel CPO
dikuantifikasi perbedaannya dengan menggunakan model fluida pada suhu 25C tersebut, secara umum dapat menunjukkan
Power Law. Model Power Law menggunakan penyederhanaan adanya variasi sifat reologi dalam produk CPO yang dihasilkan
model matematika dengan linierisasi hubungan antara shear produsen CPO di Indonesia. Hal tersebut akan berakibat pula
rate dengan shear stress. Hubungan antara nilai ln shear rate pada perbedaan perhitungan teknik rekayasa proses dan
dan ln shear stress berbentuk kurva yang linier yang dapat penanganan CPO pada suhu tersebut. Hal yang berbeda dapat
ditentukan slope serta intercept-nya, menghasilkan parameter diamati pada suhu 55C, dimana besaran parameter sifat
model fluida Power Law berupa nilai n atau indeks tingkah laku reologinya menghasilkan kisaran nilai yang relatif sempit. Hasil
aliran (flow behaviour index) dan nilai K atau indeks konsistensi pengujian ANOVA pada taraf uji 95% menunjukkan bahwa
(concistency index). Pada Gambar 2 dapat dilihat contoh sampel CPO pada suhu 55C, akan memiliki sifat fluida
penentuan nilai n dan K berdasarkan linierisasi hubungan shear mendekati fluida newtonian, dengan nilai n, K, dan yang tidak
rate dan shear stress sampel CPO. berbeda nyata antar sampel.Timms (1985) mengemukakan
5 bahwa viskositas minyak menurun sekitar 30% untuk setiap
4,5 y 0,545 x 0,897
peningkatan suhu sebesar 10C. Dengan demikian dapat di-
stress
(Pa)
4 R2==0,99
hasilkan sifat fluida yang sama yaitu menjadi bersifat newtonian
3,5 dengan nilai yang lebih rendah.
3
2,5
Titik kristalisasi dan titik leleh CPO
Salah satu sifat fisik empiris minyak dan lemak adalah titik
2 kristalisasi dan titik leleh yang ditentukan berdasarkan profil
3 3,5 4 4,5 5 5,5 6 6,5 7
In shear rate (s-1) entalpi selama kristalisasi dan pelelehan, yang digambarkan
Gambar 2. Hubungan ln shear rate dan ln shear stress sampel CPO
dengan thermogram hasil pengujian dengan Differential
dan penepatan model fluidanya Scanning Calorimetry (DSC). Profil entalpi tipikal selama
kristalisasi dan pelelehan sampel CPO (menampilkan data
Hasil penentuan nilai n dan K pada suhu 25C (Tabel 1) thermogram sampel CPO D) sebagai hasil pengujian DSC
menunjukkan bahwa nilai n sampel CPO berkisar antara 0,457- dinamik digambarkan dalam thermogram kristalisasi dinamik
0,781 sedangkan nilai K berada pada kisaran 0,369-4,530 (Gambar 3) dan thermogram pelelehan dinamik (Gambar 4).
Pa.sn. Nilai n< 1 mengindikasikan CPO merupakan fluida yang
Aliran panas endotermik
180
Hasil Penelitian J. Teknol. dan Industri Pangan, Vol. XXII No. 2 Th. 2011
Secara umum, thermogram kristalisasi yang mengalami Tabel 3. Hasil analisis mutu lima sampel CPO
pelepasan panas (proses eksotermik) memiliki bentuk yang Atribut mutu*
lebih sederhana dibandingkan thermogram pelelehan yang Sampel Kadar air Asam
Bilangan iod
mengalami penyerapan panas (proses endotermik). Thermo- CPO dan lemak
Warna (g iod/100 g
kotoran bebas
gram kristalisasi hanya dipengaruhi oleh komposisi kimia (%) (%)
sampel)
minyak dan bukan oleh status kristalisasi, sehingga thermogram CPO A Jingga kemerah- 0,68c 3,88b 51,30a,b
kristalisasi bentuknya lebih sederhana dibandingkan thermo- merahan
gram pelelehan (Tan dan Che Man, 2000). CPO B Jingga kemerah- 0,67c 4,58c 54,15c
merahan
Pada thermogram kristalisasi dan pelelehan tersebut, titik 1 CPO C Jingga kemerah- 5,39d 4,60c 50,80a
sampai 2 merupakan peak kristalisasi dan pelelehan olein, merahan
sedangkan titik 2 sampai 3 menunjukkan peak kristalisasi dan CPO D Jingga kemerah- 0,33a 5,80d 50,38a
pelelehan stearin. Menurut Chong et al. (2007), pada proses merahan
CPO E Jingga kemerah- 0,49b 3,34a 52,55b
kristalisasi CPO dengan laju pendinginan lambat, terdapat dua merahan
peak eksotermik akibat kristalisasi fraksi bertitik leleh tinggi Keterangan :
(stearin) dan fraksi bertitik leleh rendah (olein). Demikian juga *Huruf yang berbeda di belakang angka pada kolom yang sama
yang diperoleh Saberi et al. (2011) pada thermogram kristalisasi menunjukkan perbedaan nyata pada taraf uji 95%.
RBDPO yang memiliki dua peak yang mewakili fraksi dengan **Berdasarkan SNI 01-2901-2006 (BSN 2006), atribut mutu CPO:
titik leleh tinggi dan fraksi dengan titik leleh rendah. warna jingga kemerah-merahan, kadar air dan kotoran maksimal
Thermogram kristalisasi kelima sampel CPO memiliki bentuk 0,5%, asam lemak bebas maksimal 0,5%, dan bilangan iod 50-55 g
tipikal yang sesuai dengan thermogram sampel RBDPO hasil iod/100 g sampel.
penelitian Tarabukina et al. (2009). Komposisi TAG CPO dan Berdasarkan data tersebut dapat diketahui secara umum
RBDPO secara umum tidak berbeda, karena pada kedua bahwa dari lima sampel CPO yang diuji, atribut mutu warna dan
sampel tersebut belum dilakukan tahapan khusus untuk bilangan iod dapat dipenuhi. Pengujian dengan ANOVA pada
memisahkan fraksi-fraksi TAG dari sampel CPO maupun taraf uji 95% menunjukkan perbedaan yang nyata antar sampel
RBDPO. Suhu kristalisasi (crystallization temperature, TC) CPO pada atribut mutu kadar air dan kotoran, kadar asam
adalah suhu saat mulai terjadinya pelepasan panas saat suhu lemak bebas (ALB), dan bilangan iod (BI). Warna sampel CPO
diturunkan. Pada kelima sampel CPO yang dianalisis, nilai TC adalah jingga kemerah-merahan, yang disebabkan oleh
berkisar pada suhu 21,08-24,86C. Hasil yang hampir sama kandungan komponen pigmen karotenoid di dalamnya, yang
diperoleh Saberi et al. (2011) dengan sampel RBDPO yang menurut Basiron (2005) konsentrasinya berkisar antara 500-700
memiliki TC 21,16C. Pada laju penurun-an suhu 5C seperti ppm. Secara visual intensitas warna jingga kemerah-merahan
yang diterapkan dalam penelitian ini dan penelitian Tarabukina yang dimiliki setiap sampel CPO berbeda-beda, namun atribut
et al. (2009), kristalisasi tahap pertama dimulai pada suhu 22C mutu warna yang digunakan dalam SNI tidak membedakan
dan berakhir pada suhu 3C, dengan peak maksimal pada suhu intensitas warna jingga kemerah-merahan tersebut.
18C. Pada atribut mutu kadar air dan kadar kotoran, hanya
Titik leleh (melting temperature, TM) CPO ditentukan dari sampel CPO D dan E yang memenuhi persyaratan SNI dengan
suhu saat akhir kurva endotermik pelelehan. Berdasarkan kadar total di bawah 0,5%. Kadar air yang rendah sangat
thermogram DSC pelelehan dinamik diketahui bahwa TM sampel penting untuk meminimalkan terjadinya reaksi hidrolisis lemak
CPO yang digunakan berkisar pada suhu 39,12-40,68C. Pada pada CPO saat penyimpanan dan transportasi (Hilder, 1997).
suhu tersebut, sampel CPO telah mengalami pelelehan Sampel CPO A dan CPO B mengandung kadar air dan kotoran
sempurna. Hasil pengujian Saberi et al. (2011) pada sampel sedikit lebih tinggi dibandingkan persyaratan SNI, akan tetapi
RBDPO diperoleh TM sebesar 42,5C. Nilai TM pada sampel untuk sampel CPO C, kadar air dan kotoran totalnya sangat
RBDPO yang lebih tinggi dibandingkan CPO diduga terkait tinggi, yaitu mencapai 5,39%. Bila ditelusuri lebih lanjut pada
dengan proses pemurnian yang telah dialami RBDPO. sampel CPO C, diperoleh data kadar air sebesar 0,55% dan
181
Hasil Penelitian J. Teknol. dan Industri Pangan, Vol. XXII No. 2 Th. 2011
kadar kotoran sebesar 4,84%. Kadar kotoran sampel CPO C parameter sifat fisik CPO pada suhu 55C. Hal itu terjadi karena
yang sangat tinggi dapat terlihat secara visual berupa partikel- sampel yang mengalami pemanasan ke suhu 55C, akan
partikel kotoran pasir dan kerak berwarna hitam. Tingginya mengalami pelelehan fraksi stearinnya sehingga menghasilkan
kadar kotoran dapat disebabkan oleh kurang terjaganya parameter sifat fisik sampel CPO yang tidak berbeda nyata.
kebersihan peralatan dan wadah yang kontak dengan sampel Berdasarkan hasil uji korelasi yang nyata pada taraf uji
selama pengolahan dan penanganan CPO, seperti kotoran 95%, dilakukan penentuan persamaan regresi linier antara
yang berasal dari pipa dan tangki truk pengangkut CPO. atribut mutu dengan sifat fisik CPO. Persamaan regresi linier
Untuk atribut mutu kadar asam lemak bebas (ALB), tidak yang dihasilkan dengan R2 yang tinggi dapat dipergunakan
ada sampel CPO yang memenuhi persyaratan SNI 01-2901- untuk memprediksi parameter sifat fisik CPO dengan cukup baik
2006 sebesar maksimal 0,5%. Bila dibandingkan dengan melalui penggunaan data atribut mutu CPO. Terdapat dua
standar spesifikasi PORAM (The Palm Oil Refiners Association persamaan regresi linier dengan nilai R2 yang tinggi (R2>
of Malaysia), standar kadar ALB maksimal untuk CPO dan 0,750), yaitu persamaan regresi linier yang menghubungkan
produk turunannya yang belum dimurnikan adalah 5% (PORAM antara ALB dengan TC, serta persamaan regresi linier antara BI
2011). Selain itu, pada standar yang direvisi oleh SNI 01-2901- dan n25.
2006, yaitu SNI 01-2901-1992, dipersyaratkan kadar ALB
maksimal dalam CPO sebesar 5%. Dengan demikian, khusus Tabel 4. Korelasi dan persamaan regresi linier antara atribut mutu
dengan parameter sifat fisik CPO
untuk atribut mutu ALB ini, perlu ditinjau kembali standar yang Koefisien
ditetapkan dalam SNI 01-2901-2006, karena selain tidak Parameter sifat Persamaan
Atribut mutu korelasi R2
fisik regresi linier
harmonis dengan standar negara lain, kelima sampel CPO yang Pearson
dianalisis dalam penelitian ini juga tidak mampu memenuhi Asam lemak Titik kristalisasi 0,894* TC= -0,946 0,799
bebas (ALB) (TC) (ALB)+26,91
standar mutu ALB maksimal 0,5% tersebut. Bila menggunakan
persyaratan maksimal ALB sebesar 5%, maka hampir seluruh Bilangan iod Indeks tingkah 0,936* n25 = 0,078 0,876
sampel CPO dapat memenuhi persyaratan tersebut, kecuali (BI) laku aliran (BI)3,476
sampel CPO D yang mengandung ALB sebesar 5,8%. Tinggi- suhu 25C (n25)
nya kandungan ALB dalam sampel CPO dapat dipengaruhi oleh Keterangan :
* korelasi Pearson (two-tailed) nyata pada taraf uji 95%
kandungan ALB awal dalam sampel, kadar air, dan suhu
selama penanganan dan transportasi (Hilder, 1997). Menurut Persamaan regresi linier pertama yang menghubungkan
Basiron (2005), bilangan iod (BI) CPO sekitar 53 mg/100g antara ALB dengan TC adalah TC - 0,946 (ALB) + 26,91 (R =
sampel yang ditentukan oleh kesetimbangan antara kandungan 0,799). Pada ALB yang semakin tinggi, TC akan semakin
asam lemak jenuh dan tak jenuh di dalamnya. Diduga atribut rendah, dan hal itu sesuai dengan penelitian Siew dan Eng
mutu ini berkorelasi dengan sifat reologi CPO karena terkait (1996) yang menyatakan bahwa adanya gliserida parsial lain
langsung dengan fraksi asam lemak yang jenuh dan tak jenuh seperti DAG (di acyl glycerol) dan MAG (mono acyl glycerol)
di dalam sampel CPO. Standar bilangan iod CPO menurut SNI dalam CPO, yang juga mengindikasikan kadar ALB yang lebih
01-2901-1992 berada pada kisaran 50-55 g/100 g sampel, dan tinggi, akan mempengaruhi proses kristalisasi sampel CPO
kelima sampel CPO yang diujikan memenuhi persyaratan tersebut. Persamaan regresi linier yang menghubungkan antara
tersebut. BI dengan n25, yaitu n25 = 0,078 (BI) 3,476 (R = 0,876).BI
berkorelasi dengan sifat reologi CPO karena menurut Basiron
Korelasi antara atribut mutu dengan parameter sifat (2005), BI mengindikasikan derajat ketidakjenuhan asam lemak
fisik CPO yang terkandung dalam sampel CPO, dan terkait langsung
Basiron (2005) menyatakan bahwa struktur TAG dan posisi dengan keberadaan fraksi padat dan cair di dalam sampel pada
asam lemak di dalam minyak sawit sangat menentukan suhu 25C, sehingga mempengaruhi sifat reologi CPO, khusus-
karakteristik fisik minyak sawit tersebut, yang menurut Chong et nya pada indeks tingkah laku alirannya. Melalui penggunaan
al. (2007) juga berpengaruh pada tahapan kristalisasinya. Pada persamaan regresi linier yang dihasilkan dan data atribut
aplikasinya di lapangan, pengujian sifat fisik CPO menghadapi mutunya, dapat diprediksi parameter sifat fisik CPO yang akan
beberapa kendala teknis, antara lain keterbatasan instrumen menentukan pula parameter rekayasa proses yang akan
analisis, serta waktu pelaksanaan analisis sifat fisik yang cukup diterapkan pada sampel CPO tersebut. Parameter TC (yang
panjang. Dengan melakukan uji korelasi antara atribut mutu menentukan suhu saat kristalisasi CPO mulai berlangsung)
CPO sesuai SNI dengan sifat fisiknya, diharapkan dapat dapat diprediksi berdasarkan kandungan ALB-nya, sedangkan
diperoleh persamaan untuk memprediksi parameter sifat fisik parameter sifat fisik n (sebagai indeks penentu sifat reologi
CPO berdasarkan atribut mutunya. CPO) dapat diprediksi berdasarkan bilangan iodnya.
Berdasarkan pengujian korelasi Pearson (two tailed) antara
atribut mutu dengan sifat fisik CPO (Tabel 4), terdapat korelasi
KESIMPULAN
yang nyata antara BI sampel CPO dengan n pada suhu 25C
(n25), dan antara kadar ALB CPO dengan TC. Antara parameter Sifat fisik CPO kelima sampel yang diuji dipengaruhi oleh
sifat reologi (n, K dan ) juga terdapat korelasi yang nyata baik suhu pengukuran. Pada suhu 25C, densitas CPO berkisar
pada suhu 25C maupun 55C karena merepresentasikan sifat antara 0,909-0,917 g/mL, sedangkan kandungan lemak padat
fisik yang sama. Tidak terdapat korelasi yang nyata antara (solid fat content atau SFC) CPO berkisar antara 14,55-20,16%.
atribut mutu CPO (kadar air dan kotoran, ALB, dan BI) terhadap CPO bersifat sebagai fluida non-Newtonian pseudoplastic,
182
Hasil Penelitian J. Teknol. dan Industri Pangan, Vol. XXII No. 2 Th. 2011
dengan indeks tingkah laku aliran (n) 0,457-0,781, dan indeks and its effect on soft PMF and superolein quality. J Am Oil
konsistensi (K) 0,369-2,519 Pa.sn. Chem Soc 84: 885-981.
Nilai parameter sifat fisik CPO pada suhu 25C tersebut Chong CL, Kamarudin Z, Lesieur P, Marangoni A, Bourgaux C,
berbeda nyata antar sampel, kecuali untuk parameter densitas. Ollivon M. 2007. Thermal and structural behaviour of crude
Titik kristalisasi CPO berkisar antara 21,12-23,55C, sedangkan palm oil: crystallisation at very slow cooling rate. Eur J Lipid
titik leleh sampel CPO berkisar antara 38,52-39,78C, yang Sci Technol 109: 410-421.
keduanya memiliki nilai yang tidak berbeda nyata antar sampel.
CAC [CODEX Alimentarius Commission]. 2005. Recommended
Pada suhu 55C, terjadi perubahan sifat fisik CPO dibandingkan
International Code of Practice for the Storage and Transport
sifat fisiknya pada suhu 25C, dimana densitas dan SFC CPO
of Edible Fats and Oils in Bulk.CAC/RCP 36 1987 (Rev.1-
menurun berturut-turut menjadi berkisar antara 0,888-0,892
1999, Rev. 2-2001, Rev.3-2005). http://www.codexalimen
g/mL dan 2,09-7,01%. Sifat fluida CPO juga mengalami
tarius.net/download/standards/101/CXP036e.pdf. [23 Mei
perubahan dengan nilai n sampel CPO meningkat menjadi
2011].
0,936-0,994, sedangkan nilai K menurun pada kisaran 0,027-
0,031 Pa.sn, yang menunjukkan sifat fluida mendekati fluida Ditjenbun [Direktorat Jenderal Perkebunan]. 2011.Luas Areal
Newtonian. Nilai parameter sifat fisik CPO pada suhu 55C dan Produksi Perkebunan Seluruh Indonesia Menurut
tidak berbeda nyata antar sampel, kecuali untuk parameter Pengusahaan.http://www.ditjenbun.deptan.go.id/cigraph/ind
SFC. Proses pemanasan dan peningkatan suhu sampel CPO ex.php/viewstat/komoditiutama/8-Kelapa%20Sawit.html. [4
ke 55C menyebabkan sifat fisik CPO menjadi tidak berbeda Juni 2011].
nyata antar sampel. Diperoleh korelasi yang nyata antara Graef V de, Goderis B, Puyvelde P van, Foubert I, DewettinckK.
beberapa atribut mutu CPO dengan parameter sifat fisiknya, 2008. Development of a rheological method to characterize
dan terdapat dua persamaan regresi linier yang cukup baik palm oil crystallizing under shear. Eur J Lipid Sci Technol
untuk memprediksi parameter sifat fisik CPO melalui peng- 110: 521-529.
gunaan data atribut mutunya. Persamaan regresi linear antara Graef V de, Puyvelde P van, Goderis B, Dewettinck K. 2009.
kadar asam lemak bebas (ALB) dengan suhu kristalisasi (TC) Influence of shear flow on polymorphic behavior and
adalah TC = -0,946 (ALB) + 26,91 (R = 0,799); sedangkan microstructural development during palm oil crystallization.
persamaan regresi linear antara bilangan iod (BI) dengan Eur J Lipid Sci Technol 111: 290-302.
indeks tingkah laku aliran pada suhu 25C (n25) adalah n25 =
0,078 (BI) 3,476 (R = 0,876). Hilder MH. 1997. Oil storage and transportation. Dalam
Gunstone FD, Padley FB (Eds). Lipid Technologies and
UCAPAN TERIMAKASIH Applications. P. 199-222. Marcel Dekker Inc. New York.
IUPAC [International Union of Pure and Applied Chemistry].
Tim peneliti mengucapkan terimakasih kepada Direktorat 1987. Standard Methods for the Analysis of Oils, Fats and
Jenderal Pendidikan Tinggi, Kementerian Pendidikan Nasional Derivatives. Blackwell Sci Publ. Oxford.
yang telah mendanai penelitian ini melalui Program Hibah
Doktor dengan Nomor Kontrak 23/I.3.24.4/SPK/PDD/2011. Ong ASH, Choo YM, Ooi CK. 1995. Developments in palm oil.
Ucapan terimakasih juga kami sampaikan kepada Desir Detak Dalam Hamilton RJ (Ed). Developments in Oils and Fats.P.
Insani, Hanna Mery Aulia, Renny Permatasari, dan Ricky A. 153-191. Blackie Academic & Profesional. London.
Sinaga atas bantuan teknis yang diberikan dalam penelitian ini. PORAM [Palm Oil Refiners Association of Malaysia]. 2011.
PORAM Standard Specifications for Processed Palm Oil.
DAFTAR PUSTAKA http://www.poram.org.my/v1/index.php?option=com_context
&view =article&id=75&Itemid=55.html. [5 Juli 2011].
AOCS [American Oil Chemists Society]. 2005. Official Methods
and Recommended Practices of the American Oil Chemists Saberi AH, Lai OM, Toro-Vasquez JF. 2011. Crystallization
Society. AOCS Champaign. Illinois. kinetics of palm oil in blends with palm-based diacylglycerol.
BSN [Badan Standardisasi Nasional]. 2006. Standar Nasional Food Res Int. 44: 425-435.
Indonesia Minyak Kelapa Sawit. SNI 01-2901-2006. Badan Siew WL, Ng WL. 1996. Effect of diglycerides on the
Standardisasi Nasional. Jakarta. crystallization of palm oleins. J Sci Agric 71: 496500.
Basiron Y. 2005. Palm oil.Dalam Shahidi F (Ed).Baileys Steffe JF, Daubert CR.2006. Bioprocessing Pipelines: Rheology
Industrial Oil and Fat Product. P. 333-429. John Wiley & and Analyses. Freeman Press. East Lansing.
Sons Inc. Hoboken. Tan CP, Che Man YB. 2000. Differential scanning calorimetric
Braipson-Danthine S, Gibon V. 2007. Comparative analysis of analysis of edible oils: Comparison of thermal properties
triacylglycerol composition, melting properties and and chemical composition. J Am Oil Chem Soc 77: 143-155.
polimorphic behaviour of palm oil and fractions. Eur J Lipid Tarabukina E, Jego F, Haudin M, Navard P, Peuvrel-Disdier E.
Sci Technol 109: 359-372. 2009. Effect of shear on the rheology and crystallization of
Calliaw G, Gibon V, Greyt W De, Plees L, Foubert I, Dewettinck palm oil. J Food Sci 74: E405-E416.
K. 2007. Phase composition during palm olein fractionation Timms RE. 1985. Physical properties of oils and mixtures of oils.
J Am Oil Chem Soc 62: 241-248.
183