11.Which on-line parameter(s) is/are available on DCP sampling panel,
a) Sodium meters for outlet of four PCEs
b) Cationic Conductivity meters for outlet of four PCEs
c) Specific Conductivity meters for DCP mix beds
d) Silica meter for DCP mix beds
e) All of Above
12.If any parameter analysis result is abnormal,
a) Report to Head
b) Report to MCR
c) Report to LCR
d) Enter in Log book
13.If parameter analysis results are normal,
a) Report to Head and enter in Log book
b) Enter in Log book
c) Report to MCR/LCR
d) None of these
14.For an oil sample if the flash point value is not known which flash point
tester you will select
a) Open Cup flash point tester
b) Close cup flash point tester
c) None of these
15.Which corrosion inhibitor is used in DCC water,
a) Sodium Nitrate
b) Tri-Sodium Phosphate
c) Sodium Sulphate
d) Sodium Sulphite
16.Which corrosion inhibitor is used in rotor cooling water at C-3,
a) TTA
b) BTA
c) Copper Sulphate
d) None of these
17.Which DDT tank(s) is/are the source of laboratory DMW water,
a) PMW Tank
b) DMW Tank
c) Condensate Water Tank
d) Filter Water Tank
18.pH of condensate water during full power should be
a) 9.0 9.6
b) 7.0 7.6
c) 6.0 6.5
d) 8.0 8.5
19.Ammonia concentration of SG Feed Water during full power should be
a) 0.7 2.0 ppm
b) 0.5 5.0 ppm
c) 1.0 2.0 ppm
d) 3.0 5.0 ppm
20.Hydrazine concentration of SG Feed Water during full power should be
a) 20 100 ppb
b) 50 100 ppb
c) 100 200 ppb
d) 10 20 ppb