Vous êtes sur la page 1sur 4

Name___________________ Time Allowed= 40 min Marks= 40

Date: 26/11/2015 Initial Training Test

1. Which on-line parameter(s) is/are available on outlet of each AE of DDT


train,
a) pH
b) Conductivity
c) SiO2
d) Both b & c
2. The AE bed of DDT is declared exhaust on out of specification of which
parameter(s),
a) pH
b) Conductivity
c) Silica
d) Any of b or c
3. The conductivity at outlet of DDT AE bed during DMW production should
be,
a. 10 S/cm
b. 1.0 S/cm
c. 0.3 S/cm
d. 50 S/cm
4. Which parameter(s) is/are performed on outlet of each CE,
a) pH
b) COD
c) R/Cl2
d) Na
5. A representative sample is a sample of,
a) Desire specifications
b) True sample of bulk quantity
c) Known specifications
d) None of these
6. Which on-line parameter(s) is/are available on outlet of each MB of DDT
train,
a) pH
b) Conductivity
c) SiO2
d) Both b & c
7. The Silica at DDT train MB bed outlet during DMW production should be,
a) 5 ppb
b) 10 ppb
c) 20 ppb
d) 50 ppb
8. The conductivity at DDT train MB bed outlet during DMW production
should be,
a) 10 S/cm
b) 1.0 S/cm
c) 0.3 S/cm
d) 50 S/cm
9. Which of followings are good practices during work in Labs.
a) Adhere to procedures
b) Take all necessary personnel protective equipment and safety
measures
c) Housekeeping and Quality Assurance
d) All of Above
10.The max. value for Silica analysis at UV-Vis spectrophotometer is,
a) 815nm

Page 1 of 4
Name___________________ Time Allowed= 40 min Marks= 40
Date: 26/11/2015 Initial Training Test

b) 410nm
c) 510nm
d) 710nm
11.Which on-line parameter(s) is/are available on DCP sampling panel,
a) Sodium meters for outlet of four PCEs
b) Cationic Conductivity meters for outlet of four PCEs
c) Specific Conductivity meters for DCP mix beds
d) Silica meter for DCP mix beds
e) All of Above
12.If any parameter analysis result is abnormal,
a) Report to Head
b) Report to MCR
c) Report to LCR
d) Enter in Log book
13.If parameter analysis results are normal,
a) Report to Head and enter in Log book
b) Enter in Log book
c) Report to MCR/LCR
d) None of these
14.For an oil sample if the flash point value is not known which flash point
tester you will select
a) Open Cup flash point tester
b) Close cup flash point tester
c) None of these
15.Which corrosion inhibitor is used in DCC water,
a) Sodium Nitrate
b) Tri-Sodium Phosphate
c) Sodium Sulphate
d) Sodium Sulphite
16.Which corrosion inhibitor is used in rotor cooling water at C-3,
a) TTA
b) BTA
c) Copper Sulphate
d) None of these
17.Which DDT tank(s) is/are the source of laboratory DMW water,
a) PMW Tank
b) DMW Tank
c) Condensate Water Tank
d) Filter Water Tank
18.pH of condensate water during full power should be
a) 9.0 9.6
b) 7.0 7.6
c) 6.0 6.5
d) 8.0 8.5
19.Ammonia concentration of SG Feed Water during full power should be
a) 0.7 2.0 ppm
b) 0.5 5.0 ppm
c) 1.0 2.0 ppm
d) 3.0 5.0 ppm
20.Hydrazine concentration of SG Feed Water during full power should be
a) 20 100 ppb
b) 50 100 ppb
c) 100 200 ppb
d) 10 20 ppb

Page 2 of 4
Name___________________ Time Allowed= 40 min Marks= 40
Date: 26/11/2015 Initial Training Test

21.TTA in rotor cooling water should be


a) 5 20 ppm
b) 4 20 ppm
c) 2 10 ppm
d) 10 50 ppm
22.The method for hardness measurement by titration is valid in the range of
a) 10 100ppm
b) 10 500ppb
c) 20 250ppm
d) 10 500ppm
23.Which reducing agent is used during Chromate measurement by titration
a) Sodium thiosulphate
b) Sodium sulphite
c) Oxalic acid
d) None of these
24.Which indicator is used during %age acid concentration determination by
titration
a) Phenolphthalein
b) Methyl Red
c) Methyl Orange
d) EBT
25.Which indicator is used during %age base concentration determination by
titration
a) Phenolphthalein
b) Methyl Red
c) Methyl Orange
d) EBT
26.Which acid is used during COD measurement by KMnO 4 titration
a) HCl
b) H2SO4
c) CH3COOH
d) HNO3
27.Range of Chloride determination by UV-Vis spectrometer is
a) 30ppb 5000ppb
b) 20ppb 2000ppb
c) 50ppb 500ppb
d) 100ppb 1000ppb
28.Nesslers reagent (HgI2-KI) is used for analysis of,
a) Hydrazine
b) Ammonia
c) Chloride
d) TTA
29.max. value for Fluoride measurement by UV-Vis Spectrometer is,
a) 425 nm
b) 620 nm
c) 458 nm
d) 815 nm
30.Which of following reagent is used for Hydrazine measurement by UV-Vis
spectrometer
a) 1,4-dimethyl Aminobenzyldehyde
b) Hydrazinium Sulphate
c) Alizarin Blue
d) Carminic Acid
31.Chemistry Control Division may take,

Page 3 of 4
Name___________________ Time Allowed= 40 min Marks= 40
Date: 26/11/2015 Initial Training Test

a) Sample from outlet of all ion exchange beds located at NX


b) Samples from outlet of all ion exchange beds located at CI
c) Samples from inlet of all beds located at NX and CI
d) a), b), and c)
32.BAST is abbreviated for,
a) Boric Acid Stream Transfer
b) Boric Acid Solution Tank
c) Boric Acid Storage Tank
d) None of these
33.Which of the following parameter of SRC is must performed in each shift at
NX Shift lab,
a) pH, Conductivity and Silica
b) pH, Conductivity and Boron
c) pH, Chloride and D/O2
d) none of these
34.DRS is,
a) Chemical Reagent Store System
b) Chemical Regeneration and Injection System
c) Chemical Reagent and Injection and Sampling System
d) Chemical Reagent and Inspection System
35.Cation Conductivity (CC) is the conductivity of
a) Anions
b) Cations
c) Both cations and anions
d) None of these
36.Which one of the following instruments are used in NX for analysis,
a) Ion Chromatogram(IC), Uv/Vis Spectrophotometer, and AAS
b) Gas Chromatogram(GC), Karl Fischer Titrator and Viscometer
c) Open Cup Flash Point Tester, pH meter and Silica Meter
d) None of these
37.Manitol is used in,
a) Boron Analysis by Titration
b) Boron Analysis by using Uv/Vis Spectrophotometer
c) Boron Analysis by using AAS
d) None of these
38.The results of boron analysis is reported in,
a) ppm
b) ppb
c) %
d) s/cm
39.The purpose of Hydrazine is,
a) To Control pH in Feed Water
b) To Control oxygen in Feed Water
c) To Control both pH and Oxygen in Feed Water
d) To Control Chloride content in Feed Water
40.Nuclear Auxiliary Systems include,
a) SCV, SRC and SGB
b) SRC, SRH and SGB
c) SCV, SRH and SBR
d) SBR, SCV and SGB

Page 4 of 4

Vous aimerez peut-être aussi