VDR Metal Oxide Varistors Standard
FEATURES
Low high purity zinc oxide disc
Halogen free insulating epoxy coating
Zinc oxide disc, HF epoxy coated
Straight leads and kinked leads
Straight leads with flange (VDRS05 and
VDRS07 only)
Certified according to UL 1449 edition 3,
VDE/IEC 61051-1/2 and CSA
Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
QUICK REFERENCE DATA
APPLICATION
PARAMETER VALUE UNIT
Overvoltage and transient voltage protection
Maximum continuous voltage in
operating temperature range: DESCRIPTION
RMS 14 to 680 V
The varistors consist of a disc of low- ZnO ceramic material
DC 18 to 895 V with two solid copper leads (S20 types only) or copper clad
Maximum non-repetitive transient steel wire. The wires have a matte tin plating. They are
100 to 6500 A
current INRP (8 x 20 s) coated with a layer of ocher colored halogen-free epoxy,
Maximum energy which provides electrical, mechanical and climatic
0.5 to 496 J
(10/1000 s)
protection. The encapsulation is resistant to all cleaning
Based on solvents in accordance with IEC 60068-2-45.
IEC 61051-1
Detailed specification
IEC 61051-2 MOUNTING
IEC 61051-2-2
Storage temperature -40 to +125 C
The varistors are suitable for processing on automatic
insertion and cutting and bending equipment.
Operating temperature -40 to +85 C
Varistors with flanged leads provide better positioning on
ORDERING INFORMATION printed-circuit boards (PCB) and more accurate control over
component height. This is important for hand mounting and
The varistors are available in a number of packaging automatic insertion techniques; see outlines of flanged
options: leads drawing.
Bulk Typical soldering
On tape and reel 235 C, duration: 5 s (Pb-bearing)
On tape in ammopack 245 C, duration: 5 s (lead (Pb)-free)
The basic ordering code for each option is given in tables Resistance to soldering heat
titled Varistors on Tape on Reel, Varistors on Tape in
Ammopack and Varistors in Bulk. To complete the catalog 260 C, duration: 10 s max.
number and to determine the required operating MARKING
parameters, see Electrical Data and Ordering Information
The varistors are marked with the following information:
table.
Maximum continuous RMS voltage
Note
Special lead-configuration as inside or outside crimped leads on Series number (592, 593, 594, 595 or 596)
request. Safety marks on VDRS10-14-20 types
Manufacturers logo
Date of manufacture (YYWW)
INFLAMMABILITY
The varistors are passive non-flammable.
The encapsulation is made of flammable resistant epoxy in
accordance with UL 94 V-0.
50
0 10
- 40 85 125 0
Tamb (C) t (s)
t1
t2
VARISTORS IN BULK
VDRS05... VDRS07... VDRS10... VDRS14... VDRS20...
TYPE 5 mm 7 mm 10 mm 14 mm 20 mm
14 V to 460 V 14 V to 460 V 14 V to 550 V 14 V to 550 V 14 V to 680 V
Straight leads; see outline of components
BSE BSE BSE BSE BSE
with straight leads drawing (1)
Straight leads with flange; see outline of
BFE BFE - - -
components with flanged leads drawing
Kinked leads; see outline of components
BKE BKE BKE BKE BKE
with kinked leads drawing
Packaging quantities
14 V to 95 V 250 250 250 100 50
130 V to 385 V 250 250 250 100 50
420 V to 460 V 250 250 200 100 50
485 V to max. V - 250 150 100 50
Note
(1) Outline of the 20 mm differs from the other dimensions
Outline of component with straight leads Outline of component with kinked leads
D T D T
A A0
d
L F
L
F E d
D T
A0
0.3
L
d 1.4 to 1.6
52 or 55 max.
340 max.
250
max.
PACKAGING
TAPED VERSION WITH STRAIGHT LEADS (only for VDRS05 and VDRS07)
P
T
p p
D h h
d
W2
F H
L W0 W1 W
P0 P1 D0
T1 t
TAPED VERSION WITH STRAIGHT LEADS (only for VDRS10 and VDRS14)
P
T
D p p
h h
d W2
H
W0 W1 W
F P1 P0 D0
T1 t
P P
T
T D p p
D p p h h
h h
A0
A0
d
W2 d W2
F
H0
L
W0 W1 W H W0 W1 W
0
P0 P1 D0 F P1 P0 D0
T1 t T1 t
040
035
030
VOLTAGE (V)
025
020
017
100 014
10
10-5 10-4 10-3 10-2 10-1 1 10 102
CURRENT (A)
50 VRMS to 175 VRMS; VDRS05
max. leakage current max. clamping voltage
1000
175
150
140
130
095
075
060
050
VOLTAGE (V)
100
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
420
385
350
320
300
275
1000 250
VOLTAGE (V)
100
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
040
035
030
VOLTAGE (V)
025
020
017
100 014
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
100
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
460
420
385
350
320
300
275
1000 250
230
VOLTAGE (V)
100
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
040
035
030
VOLTAGE (V)
025
020
017
100 014
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
100
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103 104
CURRENT (A)
550
510
460
420
385
350
320
300
275
250
1000
VOLTAGE (V)
100
10-5 10-4 10-3 10-2 10-1 1 10 102 103 104
CURRENT (A)
040
035
030
025
VOLTAGE (V)
020
017
100 014
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
100
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103 104
CURRENT (A)
550
510
460
420
385
350
320
300
1000 275
250
VOLTAGE (V)
100
10-5 10-4 10-3 10-2 10-1 1 10 102 103 104
CURRENT (A)
040
035
030
025
VOLTAGE (V)
020
017
014
100
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103
CURRENT (A)
250
1000 230
175
150
140
130
095
075
060
VOLTAGE (V)
100
10
10-5 10-4 10-3 10-2 10-1 1 10 102 103 104
CURRENT (A)
100
10-5 10-4 10-3 10-2 10-1 1 10 102 103 104
CURRENT (A)
102 1 pulse
2
10
10 102
Ipulse max. (A)
103
104
105
106
10-1
10 102 103 104
tpulse (s)
1 pulse
2
102 10
102
103
Ipulse max. (A)
104
105
10 106
10-1
10 102 103 104
tpulse (s)
1 pulse
2
102 10
102
103
Ipulse max. (A)
104
105
10 106
10-1
10 102 103 104
tpulse (s)
105
106
10
10-1
10 102 103 104
tpulse (s)
1 pulse
2
10
102
102 103
Ipulse max. (A)
104
105
106
10
1
10 102 103 104
tpulse (s)
1 pulse
2
103
10
Ipulse max. (A)
102
103
102 104
105
106
10
1
10 102 103 104
tpulse (s)
1 pulse
2
103
10
102
Ipulse max. (A)
103
102 104
105
106
10
1
10 102 103 104
tpulse (s)
103 1 pulse
2
10
102
103
102 104
Ipulse max. (A)
105
106
10
1
10 102 103 104
tpulse (s)
104
102 105
106
10
1
10 102 103 104
tpulse (s)
104
102 105
106
10
1
10 102 103 104
tpulse (s)
1 pulse
103 2
10
102
Ipulse max. (A)
103
102 104
105
106
10
1
10 102 103 104
tpulse (s)
104
102 105
106
10
1
10 102 103 104
tpulse (s)
104
102 105
106
10
1
10 102 103 104
tpulse (s)
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
Vishay), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishays knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customers responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customers
technical experts. Product specifications do not expand or otherwise modify Vishays terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.