NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND DETAILS SEE DRAWING


A10-A-PID-VA-449162-001 THRU A10-A-PID-VA-449165-003.
2. LPN PURGE CONNECTION TO BE AS CLOSE TO B/L VALVE AS PRACTICAL.

00A
00A

A10 A A51 A10 A A51

BL BL
IP-GPB-L-3297 IP-GPB-L-3241
2" V
A10-24"-HPF-22005-1CC2H2 A51-24"-HPF-22005-1CC2P5 A10-3"-HFW-22001-6CC1P3 A51-3"-HFW-22001-6CC1P1
7458 A10-718590-206 A51-VA-728754-009 7454 A10-718585-103 A51-VA-728754-005
NI (34 C) 0 mm CSO NI (34 C) 0 mm HC (140 C) 40 mm HC (125 C) 40 mm
HP FLARE FROM PB1 HP FLARE GAS TO U&O HP FW FROM COND/FW 3/4" D D 3/4" D HP BFW TO PGB
3/4"
HX A10-E-2203

A A
LEGEND
A10 A51 A51 A10
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-004
SPECIFICATION SAES-L-105
BL BL AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
IP-GPB-L-3307 IP-GPB-L-3387
2" V PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
FAILURE STEADY
A10-24"-LPF-22010-1CC2H2 A51-24"-LPF-22003-1CC2P5 A51-4"-HPN-22001-15CC1P4 A10-6"-HPN-22001-15CC1P4 XL -PILOT LIGHT
7447 A10-718590-206 A51-VA-728754-008 A51-728754-003 7450 A10-718603-204 INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR FAILURE CLOSE
NI (34 C) 0 mm CSO NI (34 C) 0 mm NI (45 C) 0 mm 6" x 4" NI (45 C) 0 mm AIR LINE XS -LIMIT SWITCH
LP FLARE FROM PB1 LP FLARE GAS TO U&O HP NITROGEN SUPPLY HP NITROGEN SUPPLY TO INSTRUMENT
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
FROM U&O 3/4" D 3/4" D 3/4" D CGT A10-P-2201 FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
3/4" D 3/4" D 3/4" D L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
X-MISC. A-ALARM
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
CHECK VALVE FM -FLOW METER
RO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
A51 A A10 A51 A A10 GATE VALVE -HAND INDICATOR CONTROLLER
HIC MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
BL BL LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE
IP-GPB-L-3356 IP-GPB-L-3351 PRESS.RELIEF VALVE RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
A51-2"-UA-20001-1CC1P A10-2"-UA-20003-1CC1P A51-4"-IA-20003-12CG0U A10-4"-IA-20001-12CG0U
A51-VA-728754-002 7451 A10-718595-201 A51-VA-728754-002 7452 A10-718595-201 LG -LEVEL GAUGE GLASS ELECTRICAL
NI (48 C) 0 mm NI (48 C) 0 mm NI (48 C) 0 mm NI (48 C) 0 mm LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
UA SUPPLY FROM U&O IA SUPPLY FROM U&O VACUUMRELIEF VALVE -LEVEL INDICATOR
3/4" D 3/4" D 3/4" D UA SUPPLY TO PB1 3/4" D 3/4" D 3/4" D IA SUPPLY TO PB1 LI
LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
M MOTOR OPERATED
LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT
(SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
A10-2"-SG-21001-6SD0P1 INDICATOR CONTROLLER
(DCS) DISTRIBUTED CONTROL
A10-718768-204 7428 S SYSTEM, OPERATOR ACCESSIBLE
NI (45 C) 0 mm SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM

LPN PURGE INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL


PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
A10
PG -PRESSURE GAGE
(DCS) DISTRIBUTED CONTROL
ZC PI -PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
2566 PR -PRESSURE RECORDER
IN FIELD
I
PS -PRESSURE SWITCH
NOTE 1 PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
A10
PX -PRESSURE POINT INTERCONNECTING LOGIC
SEE DETAIL 1 PI
A51 A A10 A A10 PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
A51 A10

A10
2566 TI PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
BL BL ZV RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
2566 SI -SPEED INDICATOR
CONTROLLER, NORMALLY
IP-GPB-L-3267 2566 SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
IP-GPB-L-3371 NOTE 2 3/4" 1-1/2" TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
A51-4"-DMW-20001-1SA0P A10-4"-DMW-20007-1SA0P1 A51-14"-SG-22001-6SD0P A10-16"-SG-22001-6SD0P1 TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
A51-VA-728754-003 7455 A10-718597-201 A51-VA-728754-010 7448 A10-718587-205 TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
NI (34 C) 0 mm NI (34 C) 0 mm HC (55 C) 40 mm 16" x 14" ET (44 C) 40 mm
COLD DEMIN WATER COLD DEMIN WATER TO HP SYNGAS FROM GFU AO/AFC HP SYNGAS TO SYNGAS
(SELF-ACTUATED) CAN BE NORMALLY
3/4" D 3/4" D 3/4" D TE -TEMP. ELEMENT DISPLAYED ON CRT
SUPPLY FROM U&O PB1 KNOCKOUT DRUM

6SD0P1

6SD0P1
TSO -TIGHT SHUT OFF TG
I I A10-D-2201
-THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
CONTROLLER I/O POINT
OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER

1CC2H2

1CC2H2
NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL
A10-2"-HPF-22011-1CC2H2
7449 A10-718590-206
NI (34 C) 0 mm REFERENCE DRAWINGS
DRAIN TO HP FLARE LETTER IDENTIFICATION OF LINES AE-036204
PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES
A10-2"-FGH-21001-1CC2P
A10-718768-203 7410
A10
NI (94 C) 0 mm

PB02-FGS-002 Fuel gas system for HRSG(A10-U-2201)


Jazan - \A10\A10\VA-718768-205.pid - 9/28/2015 2:00:17 PM - [JE07]

ZC LPN PURGE
2570

A10

I SEE DETAIL 1 PI
A10 A A51 A51 A A10 A10

A10
2570 TI
BL BL ZV
2570
IP-GPB-L-3402 IP-GPB-L-XXXX 2570 3/4" REVISION VALIDATION
3" x 2"
A10-3"-BD-22002-1CC1P1 A51-2"-BBD-22002-1CC2W A51-3"-FGH-22001-1CC2P A10-3"-FGH-22001-1CC2P THIS REVISION NO. 00A IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
7456 A10-718586-204 A51-VA-728754-006 A51-VA-728754-004 7453 A10-718588-201
NI (50 C) 0 mm NI (50 C) 0 mm NI (33 C) 0 mm ET (94 C) 40 mm REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
HRSG BLOWDOWN FROM HRSG BLOWDOWN TO HP FUEL GAS FROM NOTE 2 AO/AFC HP FUEL TO FUEL GAS
3/4" D 3/4" D 3/4" D 10-01525-0004-XXX
COOLERS A10-E-2204A/B PGB U&O KNOCK-OUT DRUM
I I I A10-D-2235 DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
L.GAO B.ANDERS
09/25/15 09/25/15

A10-2"-LPF-22014-1CC2H2 REV.NO. DATE REVISION DESCRIPTION


7457 A10-718590-206
NI (34 C) 0 mm 00A 09/25/15 ISSUED FOR CONSTRUCTION
DRAIN TO LP FLARE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
IL - 23 TRAIN 2
POWER GENERATION UNIT
JAZAN SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

A10 A VA-718768 205 00A


Saudi Aramco 5994 ENG. (09/03)

RESTRICTED SMART CADD-05