Default Correlations
Initialization
Before entering the Oil Characterization environment, you must
create a fluid package with a specified Property Package at the
very minimum.
Property Package must be able to handle hypothetical
components (i.e., a Steam Package is not allowed).
If you want to use library components to represent the Light Ends
portion of your assay, it is best to select the components prior to
entering the Oil Characterization environment.
The Clear All, Calculate All, and Oil Output Settings buttons are
available on any tab of the Oil Characterization property view.
If you select the Calculate All button, HYSYS calculates all
Assays and Blends. This option is useful if you have several
Assays and/or Blends and you want to see the global effect of a
change in the correlation.
Selecting the Oil Output Settings button results in the Oil Output
Settings property view.
Here you can set the initial boiling point (IBP) and final boiling
point (FBP) cut points on a liquid volume, mole or mass
percentage basis.
These values are used to determine the initial and final boiling
temperatures of the TBP working curve. The default values are
1% (IBP) and 98% (FBP). HYSYS Oil Manager
Oil Output Settings Property View (contd.)
Example:
If an IBP cut point of 1% is specified, the initial boiling point
becomes the weighted average boiling temperature of all
components that boil off in the first volume percent.
The final boiling point is determined in a similar manner. If 98% is
used for the FBP, the final boiling temperature becomes the
weighted average boiling temperature of all the components that
boil off in the last 2 volume percent.
The ends of the curve are stretched to fill the assay range of 0 to
100%.
You access Oil Input settings through the Preferences view.
On the Oil Output Settings view, you can select the default ASTM
D86 ASTM D2887 and Interconversion Methods.
The Available Assays are listed in the left portion of the view.
HYSYS Oil Manager
Characterizing Assays (contd.)
Here you can set the input defaults for your case.
When a new case is created, the methods specified in the Oil
Input settings initialize the Oil Output settings.
However, any changes made afterwards to either settings group
are independent.
HYSYS Oil Manager
The Assay Property View
There are four objects found at the bottom of the property view:
Assay Was Not Calculated. You have not provided enough Assay
information, or you have not clicked the Calculate button.
Assay Was Calculated. You have provided Assay information,
clicked the Calculate button, and obtained a solution.
An Error Was Found During Calculation. The Trace Window usually
shows a description of the type of Error.
Or
When you open the Input Data tab, all that is displayed is the Assay
Data Type and Bulk Properties drop downs. New input fields are
added as you specify the information for your oil.
This group contains the Bulk Properties drop-down list with two
options:
Used If an Assay Data Type is not selected, the Input Data group
displays the Bulk Prop table along with the Molecular Weight of
lightest component field. However, if an Assay Data Type is selected,
a Bulk Props radio button appears in the Input Data group. When this
radio button is active the Bulk Prop table is displayed.
Not Used No bulk properties are considered in the oil
characterization calculations.