Parameter Unit Value

Basic Assumptions Subchannelization DL-PUSC


scheme
Total TDD Channel MHz 10
Bandwidth
Subchannel Reuse One-three
System Loading 100%
Data Rate Kbps 128
# Tx Antennas 2
# Rx Antennas 2
Carrier Frequency MHz 2500
Path loss model Cost 231
BS antenna height m 30
MS antenna height m 1.5
Number of DL 10
subchannel per sector

DL Symbols 26
DL OH Symbols 5
Effective slots per 10
subchannel
Sub-channels per slot 1
Symbols per slot 2
Total useful 48
subcarriers per slot
Total pilots per slot 8
Frame Duration ms 5
MCS QPSK1/2 bits/symbol 1
Data Rate per slot kbps 9.6
Number of slots 14
required to achieve
target rate

Required Number of 2
Subchannel
Subcarrier spacing KHz 10.94
Subchannel BW KHz 306.32
Total BW for LKB KHZ 612.64
Transmitter BS Maximum Power dBm 43
Parameters Multiple Antenna dB 3
Combining Gain
Transmitter
Parameters

Tx Antenna Gain dBi 17


RF Filter + Cable Loss dB 3

Pilot Power Boosting dB 3


Tx Duplexing Loss dB 0
Loss Due to Pilot dB -1.25
Powers
Total TX EIRP dBm 58.75
TX EIRP per required dBm 51.76
LKB BW

Receiver Parameters Thermal Noise Density dBm/Hz -174

Rx Noise Figure dB 9
Rx Antenna Gain dBi -1
Rx Diversity Gain dB 2.5
Smart Antenna Gain dB 0
RF Filter + Cable Loss dB 0

Required SINR dB 1.5


Rx Noise Density dB -165
Noise Bandwidth KHz 525.12
Noise Bandwidth dB-Hz 57.20
Rx Noise Power dB -107.80
Rx Sensitivity dB -107.80

Other Gains and Handoff Gain dB 2.5


Losses HARQ Gain dB 3
Coding Gain dB 0
Interference Margin dB 2
Penetration Loss dB 20
Log normal Fading dB 6
Margin
Total other gains & dB -22.5
losses

Link Budget dB 137.06


Cell ranges and BS Maximum cell range Km 0.63
density
Cell ranges and BS
density

BS/Km2 0.7906858361
Parameter Unit Value
Basic Assumptions Subchannelization UL-PUSC
scheme
Total TDD Channel MHz 10
Bandwidth
Subchannel Reuse One-three
System Loading 100%
Data Rate Kbps 64
# Tx Antennas 1
# Rx Antennas 2
Carrier Frequency MHz 2500
Path loss model Cost 231
BS antenna height m 30
MS antenna height m 1.5
Number of UL 11
subchannel per sector

UL Symbols 21
UL OH Symbols 3
Effective slots per 6
subchannel
Sub-channels per slot 1
Symbols per slot 3
Total useful 48
subcarriers per slot
Total pilots per slot 24
Frame Duration ms 5
MCS QPSK1/2 bits/symbol 1
Data Rate per slot kbps 9.6
Number of slots 7
required to achieve
target rate

Required Number of 2
Subchannel
Subcarrier spacing KHz 10.94
Subchannel BW KHz 262.56
Total BW for LKB KHZ 525.12
Transmitter MS Maximum Power dBm 21
Parameters Multiple Antenna dB 0
Combining Gain
Transmitter
Parameters

Tx Antenna Gain dBi -1


RF Filter + Cable Loss dB 0

Pilot Power Boosting dB 0


Tx Duplexing Loss dB 0
Loss Due to Pilot dB -1.76
Powers
Total TX EIRP dBm 18.24
TX EIRP per required dBm 18.24
LKB BW

Receiver Parameters Thermal Noise Density dBm/Hz -174

Rx Noise Figure dB 4
Rx Antenna Gain dBi 17
Rx Diversity Gain dB 2.5
Smart Antenna Gain dB 0
RF Filter + Cable Loss dB 3

Required SINR dB 2.5


Rx Noise Density dB -170
Noise Bandwidth KHz 350.08
Noise Bandwidth dB-Hz 55.44
Rx Noise Power dB -114.56
Rx Sensitivity dB -128.56

Other Gains and Handoff Gain dB 2.5


Losses HARQ Gain dB 3
Coding Gain dB 0
Interference Margin dB 2
Penetration Loss dB 20
Log normal Fading dB 6
Margin
Total other gains & dB -22.5
losses

Link Budget dB 124.30


Cell ranges and BS Maximum cell range Km 0.28
density
Cell ranges and BS
density

BS/Km2 4.1945972153