P240 Series

Foam Concentrate
Pump

Description
CHEMGUARD foam concentrate pumps are constructed
of corrosion resistant brass and stainless steel, and are
designed for use with all types of fire fighting foam
concentrates.

The pumps are Listed by Underwriters Laboratories as


meeting the stringent requirements of UL 448C, the
Standard for Stationary, Rotary-Type, Positive-Displacement
Pumps for Fire Protection Service, and Factory Mutual
Listed class 1313 and are furnished complete with pressure
relief valves which also meet the requirements of these
standards. Ordering Information
Model No. Description

Features CGP240-160 36 to 143 gpm (136 to 541 L/min)


CGP240-180 56 to 165 gpm (212 to 624 L/min)
nnSingle shaft seal as opposed to dual.
CGP240-240 96 to 224 gpm (363 to 848 L/min)
nnInternal rotary gear pump
nnFewer moving parts reduces maintenance & wear.
nnIntegral relief valve port on all pump sizes to simplify
installations allowing return to tank operation capability.
nnShaft lip seal is mounted in removable gland for ease of
replacement without major pump disassembly.
nnElectric motor and diesel engine drives available.
nnUL and FM tested for liquids ranging from water up to
4600 cps.
nnNo special material changes for using fluoroprotein
concentrates.
nnPump shafts are supported by multiple Carbon-Graphite
and/or Graphaloy bushings eliminating the possibility
that failure of one ball bearing will result in complete
pump failure.
nnTo meet UL & FM Listings, pumps must be shipped to
include drive motor (electric or diesel), listed controller
and PRV along with certificates of flow and pressure
testing.

204 South 6th Avenue l Mansfield, TX 76063 l +1-817-473-0606 l www.chemguard.com


Copyright 2012 Tyco Fire Products LP. l All rights reserved. l CHDS_CGP240_140609
Performance Table

Rated Max Working


Model No. Capacity Range Port Size Speed Pressure Range Pressure Input Power Range, Pressure Relief Valve
gpm (lpm) FNPT/300 Lb. FLG rpm psi (bar) psi (bar) hp (kW) Size, Inlet x Outlet

36 to 70 3" 40250 3.4 to 19.0 1-1/4" x 2"


CGP240-160 1000 350 (24)
(136 to 265) (76.2 mm) (2.817.2) (3.7 to 14.1) (31.75 mm x 50.8 mm)
53 to 89 3" 40250 4.4 to 22.6 1-1/4" x 2"
CGP240-160 1200 350 (24)
(201 to 337) (76.2 mm) (2.817.2) (3.3 to 16.9) (31.75 mm x 50.8 mm)
81 to 117 3" 40250 6.3 to 26.9 1-1/4" x 2"
CGP240-160 1500 350 (24)
(306 to 443) (76.2 mm) (2.817.2) (4.7 to 20.1) (31.75 mm x 50.8 mm)
108 to 143 3" 40250 8.5 to 32.5 1-1/4" x 2"
CGP240-160 1800 350 (24)
(408 to 541) (76.2 mm) (2.817.2) (6.3 to 24.2) (31.75 mm x 50.8 mm)
56 to 90 3" 40250 4.9 to 18.8 1-1/4" x 2"
CGP240-180 1000 350 (24)
(212 to 341) (76.2 mm) (2.817.2) (3.7 to 14.1) (31.75 mm x 50.8 mm)
77 to 105 3" 40250 6.5 to 24.7 1-1/4" x 2"
CGP240-180 1200 350 (24)
(291 to 397) (76.2 mm) (2.817.2) (4.9 to 18.5) (31.75 mm x 50.8 mm)
107 to 136 3" 40250 8.4 to 31.4 1-1/4" x 2"
CGP240-180 1500 350 (24)
(405 to 515) (76.2 mm) (2.817.2) (6.3 to 23.5) (31.75 mm x 50.8 mm)
138 to 165 3" 40250 11.2 to 38.2 1-1/4" x 2"
CGP240-180 1800 350 (24)
(522 to 624) (76.2 mm) (2.817.2) (8.4 to 28.7) (31.75 mm x 50.8 mm)
96 to 128 3" 40250 6.0 to 22.8 1-1/4" x 2"
CGP240-240 1000 350 (24)
(363 to 484) (76.2 mm) (2.817.2) (4.5 to 17.1) (31.75 mm x 50.8 mm)
116 to 147 3" 40250 7.7 to 29.9 1-1/4" x 2"
CGP240-240 1200 350 (24)
(439 to 556) (76.2 mm) (2.817.2) (5.8 to 22.4) (31.75 mm x 50.8 mm)
149 to 187 3" 40250 11.0 to 37.9 1-1/4" x 2"
CGP240-240 1500 350 (24)
(564 to 708) (76.2 mm) (2.817.2) (8.3 to 28.4) (31.75 mm x 50.8 mm)
196 to 224 3" 40250 16.9 to 47.3 1-1/4" x 2"
CGP240-240 1800 350 (24)
(742 to 848) (76.2 mm) (2.817.2) (12.7 to 35.5) (31.75 mm x 50.8 mm)

Note:
Actual Speed will vary and is determined by specific driver used.
See individual Pump curves for application flow rates and horsepower requirements.
Maximum pressure includes suction pressure when applicable.
To meet NFPA foam additive requirements, a positive head liquid supply is required on the suction side of the pump.
To properly size pumps, add 10% to calculated flow. The horsepower must be 15% over required.
The Pressure Relief Valve must be piped separately to return to tank with no isolation valves using the full outlet size of the PRV as
indicated.
Performance Curves with Water

Model CGP240-160 Flow


160.0

140.0

120.0

100.0
Flow, GPM

80.0

60.0

40.0

20.0

0.0
0 50 100 150 200 250
Pressure, PSIG

1000 RPM H2O 1200 RPM H2O 1500 RPM H2O 1800 RPM H2O

Model CGP240-160 Input Power


40.0

35.0

30.0

25.0
Input Power, BHP

20.0

15.0

10.0

5.0

0.0
0 50 100 150 200 250
Pressure, PSIG

1000 RPM H2O 1200 RPM H2O 1500 RPM H2O 1800 RPM H2O
Performance Curves with Water

Model CGP240-180 Flow


180.0

160.0

140.0

120.0

100.0
Flow, GPM

80.0

60.0

40.0

20.0

0.0
0 50 100 150 200 250
Pressure, PSIG

1000 RPM H2O 1200 RPM H2O 1500 RPM H2O 1800 RPM H2O

Model CGP240-180 Input Power


45.0

40.0

35.0

30.0
Input Power, BHP

25.0

20.0

15.0

10.0

5.0

0.0
0 50 100 150 200 250
Pressure, PSIG

1000 RPM H2O 1200 RPM H2O 1500 RPM H2O 1800 RPM H2O
Performance Curves with Water

Model CGP240-240 Flow


240.0

220.0

200.0

180.0

160.0
Flow, GPM

140.0

120.0

100.0

80.0

60.0

40.0
0 50 100 150 200 250
Pressure, PSIG

1000 RPM H2O 1200 RPM H2O 1500 RPM H2O 1800 RPM H2O

Model CGP240-240 Input Power


50.0

45.0

40.0

35.0

30.0
Input Power, BHP

25.0

20.0

15.0

10.0

5.0

0.0
0 50 100 150 200 250
Pressure, PSIG

1000 RPM H2O 1200 RPM H2O 1500 RPM H2O 1800 RPM H2O