Vous êtes sur la page 1sur 1

Contract Job No.

KAM KEE Drg. Ref. Calc. By Check by Calc. Sht.


STEEL'S WORK LTD No.
Part of Structure 31/3/2017
Design of 10mm Thk. GMS Angle
Ref. Calculations
1.0 INTRODUCTION
This submission cover the design calculation of 10mm Thk. GMS Angle , which connected to the U-channel.

2.0 DESIGN STANDARDS AND REFERENCES


2.1 Building (Construction) Regulations, 1990.
2.2 Code of Practice for Dead and Imposed Loads - 2011
2.3 Code of Practice for The Structural Use of Steel, Hong Kong - 2011

3.0 MATERIAL PROPERTIES :

3.1 Structural Steel

All steel shall be grade 275 complied with BS EN Standard


- For hot rolled products : adopt grade 275 in compliance with BS EN 10025
- For hot finished hollow sections : adopt grade 275J0 in compliance with BS EN 10210

Modulus of Elasticity Es = 205000 N/mm2

Design Strength (for t < 16mm) py = 275 N/mm2

Density s = 7850 kg/m3

3.2 Weld

For the Use of Weld (Fillet Weld)

Design strength of S275 fillet weld pw = 220 N/mm2