Contactor combinations
F.27 Small insulated enclosure Overload relays G
F.28 Reversing contactor
F.29 Star-delta starter type LSD
F.29 Safety relays - for emergency off or safety guard control Control and signalling units H
Auxiliary contactors
F.30 Mini, compact, SH- contactors Limit switches/Interface devices I
F.31 Coupling relays (interface)
F.31 Integrated coil operation
F.32 Accessories - compact contactors type SH 05 Manual motor starters J
F.33 Accessories - contactors type SH 04, SH4 - SH 10
F.34 Accessories - contactors type SH 5
F.35 Spare coils for SH 05 - SH 10 Moulded case circuit breakers K
Soft starters
F.38 ASTAT S Air circuit breakers L
F.40 ASTAT SD
F.42 ASTATplus
Fuse systems/Loadbreak disconnectors M
Speed drives
F.46 VAT20
F.48 VAT200 Industrial enclosures N
F.52 VAT2000
Wiring devices O
Numerical index X
F.1
Overview auxiliary contactors - Series SH
Type SH 04 SH 05 SH 5 SH8 SH10
Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals
Flat plug terminals Solder pin terminals
Solder pin terminals
AC/DC AC/DC AC/DC AC/DC AC/DC
Accord. DIN EN 50 011 SH 04.22 22E SH 05.22 22E SH 5.22 22E SH 8.44 44E SH 10.55 55E
for example SH 04.31 SH 04.31 31E SH 05.31 31E SH 5.31 31E SH 8.44 44E SH 10.55 55E
31E = 3 NO + 1 NC SH 04.40 40E SH 05.40 40E SH 5.40 40E SH 8.53 53E SH 10.64 64E
SH 04.13 13E SH 5.04 04E SH 8.53 53E SH 10.73 73E
0 = overlapping contacts SH 5V.22 22E SH 8.62 62E SH 10.73 73E
SH 8.62 62E SH 10.82 82E
SH 8.71 71E SH 10.91 91E
SH 8.80 80E SH 10.100 100E
Accessories
see also type see also type
for direct mounting LS 02K, LS 05 LS 4K...LS 7K
F.2
Overview mini and compact contactors - Series LS and LS...K up to 5,5 kW
Type LS 07 LS 02K LS 05K LS 06K
Contactors 3-pole Screw terminal Screw terminal Screw terminal Screw terminal
F-Flat plug terminal F-Flat plug terminal F-Flat plug terminal AC, DC .10/.01
AC Alternating current control Solder-Pin terminal Solder-Pin terminal Solder-Pin terminal
DC Direct current control AC, DC .10/.01 AC, DC .10/.01 AC, DC .10/.01
AC/DC control with electronic coil energization
Over view
DC Direct current control
AC/DC control with electronic coil energization Screw terminal Screw terminals
Accessories
for direct installation HS 05K 2-/4-pole, front +36 mm HS 05 1-pole, front + 9.8mm
Type b 05
Current rating 0.11 ... 14A
F.3
Overview compact contactors - Series LS...K up to 55 kW
Type LS 4K LS 5K LS 7K LS 11K LS 12K
Contactors 3-pole Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal
AC .00/.10/.01 AC .00/.10/.01 AC .00/.10/.01 AC .00/.10/.01 AC .10/.01
AC Alternating current control DC .10/.01 DC .10/.01 DC .10/.01 DC .00 DC .10/.01
DC Direct current control
AC/DC control with electronic coil energization
Contactors
Contactor style 3-pole 3-pole | 4-pole 3-pole | 4-pole 3-pole | 4-pole 3-pole
Motor rating 230 V kW 2.2 3 4 7.5 7.5
AC-3 duty, 3~ 400 V kW 4 5.5 7.5 11 12
415 V kW 4 5.5 7.5 11 12
500 V kW 5.5 7.5 10 15 15
690 V kW 5.5 7.5 10 15 15
Ie max. AC-3 (Ue 440 V) A 9 12 18 25 25
Resistive load AC-1 A 25 25 32 45 45
Dimensions width mm 45 45 45 45/55 55
without auxiliary contacts higth mm 81 81 81 81/87 87
depth mm 85/115 85/115 85/115 85/115 | 98/134 98/134
Aux. contact integrated .00/.10/.01 .00/.10/.01 | .00 .00/.10/.01 | .00 .00 .00
front HS 7K/V HS 7K/V HS 7K/V HS 7K/V HS 7K/V
side HS 8K/R HS 8K/R HS 8K/R HS 8K/R HS 8K/R
Timer pneumatic front TMD.../TMI... TMD.../TMI... TMD.../TMI... TMD.../TMI... TMD.../TMI...
electronic front BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG
Mech. latch mechanical front WBK WBK WBK WBK WBK
F Transient voltage RC-module at A1/A2 LR 2K LR 2K LR 2K LR 2K LR 2K
suppressor diode at A1/A2 LDK LDK LDK LDK LDK
varistor at A1/A2 LV 3K LV 3K LV 3K LV 3K LV 3K
Interlock mechanical side LUV 18K LUV 18K LUV 18K LUV 18K LUV 18K
mech. + electr. side LUV 18E LUV 18E LUV 18E LUV 18E LUV 18E
Interface module at A1/A2 IMR.../S.../A... IMR.../S.../A... IMR.../S.../A... IMR.../S.../A... IMR.../S.../A...
Main contacts spare CS 4 CS 5 | CS 5C CS 7 | CS 7C CS 11 | CS 11C
Spare coils AC-operated C 650-XX C 650-XX C 650-XX C 650 / 652-XX C 652-XX
DC-operated C 660-XX C 660-XX C 660-XX C 660 / 662-XX C 662-XX
Accessories
HS 7K.10 HS 8K.11 LUV 18K TMD 30 WBK 24 V
for direct installation HS 7K.01 HS 8K.20 LUV 18E TMD 60 WBK 42 V
for contactors type LS 4..K up tot LS 55..K HS 7V.10 HS 8R.11 WBK 60 V/DC
HS 7V.01 HS 8R.20 LUV 55K TMI 30 WBK 110 V
front +29 mm side +12,4 mm LUV 55E TMI 60 WBK 230 V
WBK 400 V
WBK 500 V
Type b 18K
Current rating 0.16 40 A
F.4
LS 15K LS 18K LS 22K LS 30K LS 37K LS 45K LS 55K
Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal
Double box termin. Double box termin. Double box termin. Double box termin. Double box termin. Double box termin. Double box termin.
AC .00/.10/.01/.11 AC .00/.11/.22 AC .00/.22 AC .00/.22 AC .00/.22 AC .00/.22 AC .00/.22
DC .00 DC .00 AC/DC .00 AC/DC .00 AC/DC .00 AC/DC .00 AC/DC .00
Over view
LS 15K-4.00 LS 18K-4.00 LS 30K-4.00 LS 37K-4.00 LS 45K-4.00 LS5 55K-4.00
LS 15K-22.00 LS 18K-22.00 LS 30K-22.00 Screw terminal Screw terminal see page F.6
Screw terminal Screw terminal Screw terminal Double box termin. Double box termin.
Box termin. Double box termin. Double box termin. AC, AC/DC AC, AC/DC
AC, AC/DC AC, AC/DC AC, AC/DC
3-pole | 4-pole 3-pole | 4-pole 3-pole 3-pole | 4-pole 3-pole | 4-pole 3-pole | 4-pole 3-pole
9 11 15 18.5 22 25 30
16 18.5 22 30 37 45 55
16 22 25 37 45 50 55
18.5 25 30 40 45 55 65
18.5 30 35 45 45 55 65
32 40 50 65 80 95 105
60 60 | 90 90 110 110 140 140
55 55 | 87 66 66 | 87 66 | 87 75 | 96 75
87 55 | 117.5 117.5 117.5 117.5 117.5 117.5
98/134 98/134 | 119/147 116/144 116/144 | 119/147 116/144 | 119/147 126/154 126/154
.00 .00 .00 .00 .00 .00 .00
HS 7K/V HS 7K/V HS 7K/V HS 7K/V HS 7K/V HS 7K/V HS 7K/V
HS 8K/R HS 8K/R HS 8K/R HS 8K/R HS 8K/R HS 8K/R HS 8K/R
TMD.../TMI... TMD.../TMI... TMD.../TMI... TMD.../TMI... TMD.../TMI... TMD.../TMI... TMD/TMI
BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG BETL...CG/...DG
WBK WBK WBK WBK WBK WBK WBK
LR 2K LR 2K LR 2K / LR 3K LV 3K LV 3K LV 3K LV 3K F
LDK LDK LDK / - - - - -
LV 3K LV 3K LV 3K LV 3K LV 3K LV 3K LV 3K
LUV 18K LUV 18K | LUV 55K LUV 55K LUV 55K LUV 55K LUV 55K LUV 55K
LUV 18E LUV 18E | LUV 55E LUV 55E LUV 55E LUV 55E LUV 55E LUV 55E
IMR.../S.../A... IMR.../S.../A... IMR.../S.../A... IMR.../S.../A... IMR.../S.../A... IMR.../S.../A... IMR.../S.../A...
CS 15 | CS 15C CS 18 | CS 18C CS 22 CS 30 | CS 30C CS 37 | CS 37C CS 45 CS 55 C
C 652-XX C 652 / 653-XX C 653-XX C 653-XX C 653-XX C 653-XX C 653-XX
C 662-XX C 662 / C664-XX see page F.20 see page F.20 see page F.20 see page F.20 see page F.20
b 18K b 55K
0.16 40 A 11.5 110 A
F.5
Overview compact contactors - Series LS...K 75 up to 450 kW
Type LS 55K-4 LS 75K LS 90K LS 110K LS 132K LS 160K
Contactors 3-pole LS 55K (3-pole) Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal
...5 AC .22 AC .22 AC .22 AC/DC .22 AC/DC .22
AC Alternating current control AC/DC .11 AC/DC .11 AC/DC .11
DC Direct current control
AC/DC AC/DC control with
electronic coil energization
Contactors
Main contacts:
LS ...K-4 = 4NO
LS ...K-22 = 2NO + 2NC
LS ...K-4 = 4NC
Contactor style 4-pole 3-pole 3-pole | 4-pole 3-pole 3-pole | 4-pole 3-pole | 4-pole
Motor rating 230 V kW 30 45 55 65 75 90
AC-3 duty, 3~ 400 V kW 55 75 90 110 132 160
415 V kW 55 80 100 125 132 185
500 V kW 65 100 110 132 160 200
690 V kW 65 100 132 155 200 250
Ie max. AC-3 (Ue 440 V) A 105 150 185 205 250 309
Resistive load AC-1 A 200 250 250 | 325 315 315 | 400 450 | 500
Dimensions Width mm 173 135 135 | 253 173 173 | 253 173 | 253
without auxiliary contacts Higth mm 200 178(1) 178(1) | 270 212 212 | 270 212 | 270
LS 75K .... LS 450K with .22 Depth mm 176 165.5 165.5 | 246 208 208 | 246 208 | 246
Aux. contact integrated .00 .00 .00 .00 .00 .00
front - - - - - -
side HS 8K/R HS 8K/R HS 8K/R HS 8K/R HS 8K/R HS 8K/R
Timer pneumatic front - - - - - -
electronic front - - - - - -
Mech. latch mechanical front - - - - - -
F Transient voltage RC-module at A1/A2 LR 5K LR 3K LR 3K | LS 5K LR 5K - -
suppressor Diode at A1/A2 - - - - - -
Varistor at A1/A2 LV 3K LV 3K LR 3K | - - - -
Interlock mechanical side LUV 375 LUV 375H/V LUV 375H/V LUV 375H/V LUV 375H/V LUV 375H
mech. + electr. side - - - - - -
Interface module at A1/A2 - - - - - -
Main contact spares CS 55F CS 75 CS 90 CS 110 CS 132 CS 160
Spare coils AC-operated C 655-XX C 654-XX C 654-XX | C 656-XX C 655-XX AC/DC(2) AC/DC(2)
DC-operated AC/DC(2) AC/DC(2) AC/DC(2) AC/DC(2) AC/DC(2) AC/DC(2)
Accessories
HS 8K .11 LR 5K LUV 375H
for direct installation HS 8K .20 ... 24 V/AC
HS 8R .11 48 ... 260 V/AC
HS 8R .20 380 ... 415 V/AC
side + 12,4 mm
Type - b 90 b 160K
Current rating - 55...190 A 120...310 A
Over view
LS 220K-4 LS 280K-4 LS 375K-4 LS 450K-4
Screw terminal Screw terminal Screw terminal Screw terminal
AC/DC AC/DC AC/DC AC
b 375K b 450K
120 700 A 500 850 A
(1) AC/DC: with electronic modules CD...-XX and coils C...-XX see catalogue page F.20
(2) with control circuit C 675-XX
F.7
AC contactors
Mini-contactors
Power rating [kW], AC operation DC operation
AC-3, 3~ 240V 50Hz 230V DC
230V 400V 500V 690V Designation E-No. E-No. Pack.
3P Screw terminal
at 24V DC: 1.2W 1.5 3 LS 07.10 910-302 003-000 910-302 011-000 10
1.5 3 LS 07.01 910-302 023-000 910-302 031-000 10
4P Screw terminal
at 24V DC: LS 07-4 1.2W 1.5 3 LS 07-4.00 910-302 005-000 910-302 015-000 10
LS 07-22 2.5W 1.5 3 LS 07-22.00 910-302 198-000 910-302 020-000 10
E-No. voltage suffix 910 -. . . . . .- XX0 for contactors type LS 07 (coil not replaceable)
AC-operation suffix -8C -85 -84 -8F -87 -88 -86 -8H -8K -69 -89 -64 -00 -81 -63 -83 -80
50 Hz [V] 20 24 42 60 92 110 100 115 125 185 200 220 230 240 380 400 415
60 Hz [V] 24 28 48 70 110 125 115 150 220 230 255 265 280 440
F
AC-operation suffix -7G -75 -62 -7A -77 -78 -76 -7B -7C -7D -79 -7E -74 -71 -7F -73 -70
m m m m m m m m m m m m m m m m m
0.75 US-coil 50 Hz [V] 20 24 42 60 92 110 100 115 125 185 200 220 230 240 380 400 415
60 Hz [V] 24 28 48 70 110 125 115 150 220 230 255 265 280 440
AC-operation suffix -55 -54 -57 -58 -56 -5C -68 -5D -50 -51 -5E -59
Double frequency coil 50/60 Hz [V] 24 42 48 110 115 120 200 220 230 240 380 400
DC-operation suffix -1A -1B -00 -1C -1D -1E -16 -17 -1F -18 -1G -14
(Maximum coil voltage m m m m m m m
only DC 180V) DC [V] 6 12 24 30 36 42 48 60 72 110 120 125
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
Ordering example: Contactor type LS 07.10 with e.g. standard coil 24V 50Hz E-No 910-302 003-850, e.g. with standard coil DC 48V E-No 910-302 011-160
Price increase: For contactors from table with designation m a price increase has to be considered.
F.8
AC contactors
Compact contactors
Power rating [kW], AC operation DC operation
AC-3, 3~ 230V 50Hz 24V DC
230V 400V 500V 690V Designation E-No. E-No. Pack.
3P Screw terminal
Up to 6 auxiliary contacts can be added 1.5 2.2 3 3 LS 02K.10 910-304 000-000 910-304 005-000 20/10
1.5 2.2 3 3 LS 02K.01 910-304 001-000 910-304 006-000 20/10
3 4 4 4 LS 05.10 910-303 001-000 910-303 101-000 20/10
3 4 4 4 LS 05.01 910-303 002-000 910-303 102-000 20/10
3 5.5 5.5 5.5 LS 06k.10 910-303 400-000 910-303 405-000 20/10
3 5.5 5.5 5.5 LS 06k.01 910-303 401-000 910-303 406-000 20/10
Series LS...K
Flat plug terminal 2 x 2.8mm (1 x 6.3/2 x 2.8mm, AC 1: 20A, on request)
1.5 2.2 3 3 LS 02K.10 910-304 010-000 910-304 015-000 20/10
1.5 2.2 3 3 LS 02K.01 910-304 011-000 910-304 016-000 20/10
3 4 4 4 LS 05.10 910-303 021-000 910-303 121-000 20/10
3 4 4 4 LS 05.01 910-303 022-000 910-303 122-000 20/10
F
Interface contactors 3P Screw terminal
Additional 2 auxiliary contacts 1.5 2.2 3 3 LS 02K.10 910-304 037-000 10
max. 24V DC / 2W 1.5 2.2 3 3 LS 02K.01 910-304 038-000 10
3 4 4 4 LS 05.10 910-303 206-000 10
3 4 4 4 LS 05.01 910-303 207-000 10
F.9
AC contactors
Compact contactors
Power rating [kW], AC operation DC operation
AC-3, 3~ 230V 50Hz 24V DC
230V 400V 500V 690V Designation E-No. E-No. Pack.
4P Screw terminal
Up to 6 auxiliary contacts can be added 1.5 2.2 3 3 LS 02K-4.00 910-304 050-000 910-304 065-000 20/10
1.5 2.2 3 3 LS 02K-22.00 910-304 051-000 910-304 066-000 20/10
1.5 2.2 3 3 LS 02K-04.00 910-304 052-000 20/10
E-No. voltage suffix - 910 -... ...- XX0 for contactors type LS 02K and LS 05
AC-operation suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -89 0 -8P -63 -80 -82
50 Hz [V] 24 42 48 110 115- 200 220- 380- 415- 500
127 240 400 440
60 Hz [V] 24 48 60 110 115 120 208- 230 240- 380 440 480 600
220 277
AC-operation suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
Double frequency coil 50/60 Hz [V] 24 42 48 110- 120 200 220 230 240 400 440
115
DC-operation suffix -1A -1B 0 -1C -1D -1E -16 -17 -1F -18 -1G -14 -19 -1J -20
F (Maximum coil voltage m m m m m m m m m
only 250V/DC) DC [V] 6 12 24 32 36 42 48 60 72 110 120 125 220 240 250
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
Ordering example: Contactor type LS 05.10 with e.g. standard coil 24V 50Hz E-No 910-303 001-850, e.g. standard coil DC 48V E-Nr 910-303 101-160 For contactors from
table with designation m a price increase has to be considered.
F.10
AC contactors
Accessories for compact contactors
For contactors DIN
Description type LS 02K, LS 05 EN... Designation E-No. Pack.
Series LS...K
Design no. 10E 41E HS 05K.31 910-304 907-000 10
F.11
AC contactors
Accessories for compact contactors (continued)
For contactors DIN
Description type LS 02K, LS 05 EN... Designation E-No. Pack.
Diode
US = 6 - 240V DC Any design no. EB 05 910-393 113-000 1
Contactors
Type-/E---No. voltage suffix - for spare coils for contactors LS 02K and LS 05
AC-operation suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -89 0 -8P -63 -80 -82
F 50 Hz [V] 24 42 48 110 115- 200 220- 380- 415- 500
127 240 400 440
60 Hz [V] 24 48 60 110 115 120 208- 230 240- 380 440 480 600
220 277
AC-operation suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
Double frequency coil 50/60 Hz [V] 24 42 48 110- 120 200 220 230 240 400 440
DC-operation(1) suffix -1A -1B 00 -1C -1D -1E -16 -17 -1F -18 -1G -14 -19 -1J -20
(Maximum coil voltage m m m m m m m
only 250 V/DC) DC [V] 6 12 24 32 36 42 48 60 72 110 120 125 220 240 250
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
Ordering example
for spare coils: Spare coils for type LS 02K with 24V 50Hz Type C 130-85, E-No. 910-393 130-850
Price increase: For coils from table with designation m a price increase has to be considered.
F.12
AC contactors
LS ... K-contactors
Power rating [kW], AC operation DC operation
AC-3, 3~ 230V 50Hz 24V DC
230V 400V 500V 690V Designation E-No. E-No. Pack.
3P Screw terminal
2.2 4 5.5 5.5 LS 4K.00 910-304 102-000 - 1
2.2 4 5.5 5.5 LS 4K.10 910-304 100-000 910-304 105-000 1
2.2 4 5.5 5.5 LS 4K.01 910-304 101-000 910-304 106-000 1
Series LS...K
3 5.5 7.5 7.5 LS 5K.01 910-304 151-000 910-304 156-000 1
Screw terminal
45 75 100 100 LS 75K.22 910-304 451-000 - 1
45 75 100 100 LS 75K.11 AC/DC(1) 910-304 453-440 910-304 453-400 1
AC operation
220-240V 50/60Hz
Deviating operation voltages and E-No. voltage suffix see page F.15
(1) AC/DC-electronic coil for AC and DC operation with E-No. end digit -400 only DC 24-28V
F.13
AC contactors
LS K-contactors
Power rating [kW], AC operation DC operation
AC-3, 3~ 230V 50Hz 24V DC
230V 400V AC-1 Designation E-No. E-No. Pack.
Ie [A]
4P Screw terminal
3 5.5 25 LS 5K-4.00 910-304 160-000 910-304 165-000 1
3 5.5 25 LS 5K-22.00 910-304 161-000 910-304 166-000 1
Screw terminal
30 55 200 LS 55K-4.11 910-304 445-000 1
30 55 200 LS 55K-4.11 AC/DC(1) 910-304 448-440 910-304 448-400 1
F
AC/DC operation AC/DC operation
220-250V 50/60Hz, DC 24-28V 50/60Hz, DC
AC operation
220-240V 50/60Hz
Screw terminal
250 450 1250 LS 450K-4.11 910-304 535-230 1
Deviating operation voltages and E-No? voltage suffix see page F.15
(1) Contactors with AC/DC electronic coil can be used for DC or AC 50-60 Hz, with voltage suffix -400 only for 24-28V.
F.14
E-No. voltage suffix - 910 -... ...- XX0 for contactors type LS 4K up to LS 450K
AC-operation suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -8M -00 -81 -8P -63 -83 -80 -82 -8S
LS 4K - LS 110K (3P) 50 Hz [V] 24 42 48 110 127 208(1) 220- 240 380 380- 415 500 660-
230 400 690
LS 5K-4 - LS 90K-4 (4P) 60 Hz [V] 24 48 110 115 120(1) 220 240 277 380 440 480 600
AC-operation Double suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
frequency coil(2)
LS 4K - LS 55K (3P) 50/60 Hz [V] 24 42 48 110- 120 200 220 230 240 400 440
LS 5K-4 - LS 45K-4 (4P)
DC-operation suffix -1A -1B -00 -1C -1D -1E -16 -17 -1F -18 -1G -14 -19 -1H -1J -20 -1K
Series LS...K
LS 4K - LS 18K (3P) m m m m m m m m m m m
LS 5K - LS 15K (4P) DC [V] 6 12 24 32 36 42 48 60 72 110 120 125 220 230 240 250 440
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
Ordering example Contactor type LS 5K-4.00 (4-pole, screw term.) with e.g. coil 24V 50Hz E-No. 910-304 160-850 or e.g. coil DC 48V E-No. 910-304 165-160
for spare coils: For contactors from table with designation m a price increase has to be considered.
(1) only up to LS 55K (3-pole) resp. LS 45K-4
(2) for larger types see AC/DC-electronic coil for 50/60Hz and for DC.
(3) only for DC 24 - 28V, not for AC 50/60Hz
Type LS 55K LS 75K LS 90K LS 90K LS 110K LS 132K LS 132K LS 160K LS 220K LS 280K LS 375K LS 450K
(4p) (4p) (4p) (3 + 4p) (3 + 4p) (3 + 4p) (3 + 4p) (3 + 4p)
Coordination type 2
gG/gL [A] 250 250 250 400 315 400 500 500 630 800 1000 1250
Coordination type 1
gG/gL [A] 315 355 355 500 500 500 630 630 1250 1250 1250 2 x 800
Without Welding
gG/gL [A] 200 200 200 250 250 315 315 425 500 630 800 1000
F.15
AC contactors
With DC wide range coils
DC operated with wide range coil 0,7 - 1,3 x Us
Power rating, (kW), AC-3, 3 AC-1 Additional DC operation
230V 400V 500V 690V Ie (A) aux. cont. Designation 24 V/DC Pack.
3P
Screw terminal
2.2 4 5.5 5.5 25 2NO or 1NC LS4K.10 DWD 136484 1
3 5.5 7.5 7.5 25 2NO or 1NC LS5K.10 DWD 136485 1
4 7.5 10 10 32 2NO or 1NC LS7K.10 DWD 136486 1
Screw terminals
45 75 100 100 250 without LS75K.11EWD 136495 1
55 90 110 132 250 without LS90K.11EWD 136496 1
4P Screw terminals
3 5.5 7.5 7.5 25 2NO or 1NC LS5K-4.00 DWD 136568 1
4 7.5 10 10 32 2NO or 1NC LS7K-4.00 DWD 136569 1
Screw terminals
55 90 110 132 325 without LS90K-4.11 EWD(4) 136575 1
F.16
AC contactors
Accessories for LS...K-contactors
Fits contactors
Description type ... Designation E-No./Ref. No. Pack.
Series LS...K
Auxiliary contact block, Screw terminal, for side mounting,
2 contacts DIN EN 50 005, DIN EN 50 012 LS 4K - LS 450K HS 8K.11 910-304 560-000 10
HS 8K.20 910-304 561-000 10
R: for mounting more than 4 front LS 22K - LS 450K, HS 8R.11 910-304 562-000 10
or 2 side-mounted auxiliary contacts LS 18K-4 HS 8R.20 910-304 563-000 10
F.17
AC contactors
Accessories for LS...K-contactors
Fits contactors
Description type... Designation E-No./Ref. No. Pack.
Via semi-conductor
Ue (entrance) DC 6 - 48V LS 4K - LS 55K (AC/DC 24 - 250V)(1), IMSSDG 136678 5
LS 12KWC - LS 70KWC (AC 24 - 250V)
F.18
AC contactors
Spare parts LS...K-contactors
Fits contactors
Description type ... Designation E-No. Pack.
Series LS...K
LS 18K CS 18 910-304 635-000 1
F.19
AC contactors
Spare coils for alteration of control voltages of existing contactors
For alternation of control voltages of existing contactors
For contactors with LS 4K - LS 7K, LS 11K (3-pole) DC coil C 660-XX 910-304 660-XX0 1
DC operation LS 11K (4-pole), LS 15K, LS 18K (3-pole) C 662-XX 910-304 662-XX0 1
F
Type-/E---No. voltage suffix - For spare coils for contactors type LS 4K - LS 450K
AC-operation suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -8M -00 -81 -8P -63 -83 -80 -82 -8S
(not for LS 450K) 50 Hz [V] 24 42 48 110 127 208(1) 220- 240 380 380- 415 500 660-
230 400 690
60 Hz [V] 24 48 110 115 120(1) 220 240 277 380 440 480 600
AC-operation Double suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
frequency coil(1)
(not for LS 450K) 50/60 Hz [V] 24 42 48 110- 120 200 220 230 240 400 440
115
DC-operation suffix -1A -1B -00 -1C -1D -1E -16 -17 -1F -18 -1G -14 -19 -1H -1J -20 -1K
m m m m m m m m m m m
DC [V] 6 12 24 32 36 42 48 60 72 110 120 125 220 230 240 250 440
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
Ordering example Spare coil for contactor type LS 4K e.g. coil 24V 50Hz: Type C 650-85, E-Nr 910-304 650-850
for spare coils: or spare coil for contactor type LS 11K e.g. coil DC 48V: Type C 662-16, E-Nr 910-304 662-160
For spare coils from table with designation m a price increase has to be considered.
F.20
AC contactors
Contactors for capacitor switching
kVAr values at ambient temperature +55C
Connection by screws
7.5 12.5 16 15 LS12KCW.20A00 910-304 800-000 1
7.5 12.5 16 15 LS12KCW.11A00 910-304 801-000 1
7.5 12.5 16 15 LS12KCW.02A00 910-304 802-000 1
Series LS...K
10 16.7 21 20 LS16KCW.20A00 910-304 810-000 1
10 16.7 21 20 LS16KCW.11A00 910-304 811-000 1
10 16.7 21 20 LS16KCW.02A00 910-304 812-000 1
Suffix for designation and E-No.910 -. . . . . .- XX0 for capacitor switching type LS 12KCW up to LS 70KCW
Alternating current Suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -8M -00 -81 -8P -63 -83 -80 -82 -8S
LS 12KCW - LS 70KCW 50 Hz [V] - 24 42 48 - - 110 127 208 220- 240 - 380 380- 415 500 660-
(3-P) 230 400 690
60 Hz [V] 24 - 48 - 110 115 120 - 220 240 277 - 380 440 480 - 600
Alternating current. Suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
Dual frequency
LS 12KCW - LS 70KCW 50-60 Hz [V] - 24 42 48 - 110- 120 - 200 220 230 240 - - 400 440 - -
(3-P) 115
F.21
AC contactors
LS- contactors, 3-pole
Please note the new LSK compact contactors with extensive,modular accessories
Screw terminal
up to LS 37 with screw and rail mounting
2.2 4 5.5 5.5 LS 4.00 910-302 645-000 - 1
2.2 4 5.5 5.5 LS 4.10 910-302 623-000 910-302 701-000 1
2.2 4 5.5 5.5 LS 4.01 910-302 630-000 910-302 703-000 1
2.2 4 5.5 5.5 LS 4.11 910-302 650-000 910-302 736-000 1
Contactors
AC operation DC operation(1)
230V 50Hz 220V DC
Dual box type terminal
11 22 30 37 LS 47.22 910-337 341-000 910-337 346-000 1
18.5 30 37 37 LS 57.22 910-337 351-000 910-337 356-000 1
22 37 45 55 LS 77.22 910-337 361-000 910-337 366-000 1
26 45 59 67 LS 87.22 910-337 370-000 910-337 375-000 1
30 55 75 80 LS 107.22 910-337 141-000 910-337 151-000 1
45 75 90 80 LS 147.22(2) 910-337 160-000 910-337 170-000 1
Screw terminal
55 90 110 132 LS 177.22 910-337 301-000 910-337 311-000 1
65 110 145 132 LS 207.22(2) 910-337 320-000 910-337 330-000 1
75 132 160 200 LS 247.22 910-338 071-000 910-338 086-000 1
90 160 160 200 LS 307.22(2) 910-338 350-000 910-338 356-000 1
- Contactors with integrated coil wiring and coupling relay (interface) see page F.23
- Auxiliary switch arrangement LS 4.31 - LS 37.31 on request
- Additional auxiliary switch HS 107 for type LS 47 - LS 307 see page F.24
- DC-operated contactors with economy circuit type LS 4.22 - LS 37.22 on request
F.22
AC contactors
LS- contactors
Please note the new LSK compact contactors with extensive, modular accessories
Series LS...K
4 7.5 9 5.5 LS 17.22 (diode) - 910-302 738-000
4 7.5 9 5.5 LS 17.22 (V/bz)(1) 910-302 654-000 910-302 740-000 1
7.5 15 18.5 15 LS 37.22 (diode) - 910-301 708-000
LS 37.22 (V/bz)(1) 910-301 628-000 910-301 709-000 1
Screw terminal
55 90 110 132 LS 177.22 (RC)(2) 910-337 304-000 - 1
75 132 160 200 LS 247.22 (RC)(2) 910-338 077-000 - 1
4P Screw terminal
2.2 4 5.5 5.5 LS 4-4.00 910-302 555-000 910-302 705-000 1
3 5.5 7.5 5.5 LS 7-4.00 910-302 548-000 910-302 708-000 1
4 7.5 9 5.5 LS 17-4.00 910-302 666-000 910-302 706-000 1
(1) AC current with varistor up to LS 37, also for 42V 50Hz; DC current with bidirectional Z-diode only available for DC 24V
(2) With RC-combination
(3) With resistors for suppressing the switch-on peak current. Early make contacts are parallel to the main contacts.
F.23
AC contactors
Accessories for LS- contactors
Please note the new LSK compact contactors with extensive, modular accessories
Mechanical latch With electrical impulse or manual, for front snap-on mounting
50 Hz [V] 60 Hz [V] DC [V]
24 24 - 28 24 LS 4 - LS 37 (single-tier) WB 30/24 910-392 311-000 1
42 42 - 48 42 WB 30/42 910-392 312-000 1
48 48 - 53 48 WB 30/48 910-392 313-000 1
110 110 - 127 110 WB 30/110 910-392 314-000 1
220 - 230 220 - 255 220 - 230 WB 30/230 910-392 316-000 1
230 - 240 230 - 277 230 - 240 WB 30/240 910-392 315-000 1
380 - 415 380 - 440 380 - 415 WB 30/400 910-392 317-000 1
415 - 440 440 - 480 415 - 440 WB 30/415 910-392 318-000 1
(1) Kit containing 3 clamps for contactors of same size and snap-on mounting.
With screw fixation a combination of different types are available.
For contactors LS 47 - LS 307, see page F.28
F.24
AC contactors
Accessories for LS- contactors
For contactors
Description type LS 02K, LS 05 Designation E-No. Pack.
For snap-on mounting in terminal covers, can be labelled using a waterproof marker
Identification label (Z-Nr. 227 261 R01) LS-Contactors, KZS 910-392 366-000 100
b 27T - b 721Sw
Series LS...K
Terminal cover For mounting on LS 47 - 87, 1 set = 2 items (one for top/ one for bottom terminals)
for contactors without box terminal block (contact protection device acc. to DIN VDE 0106 Part 100)
fixing with arcing chamber LS 47 - LS 87 KLA 87 910-392 273-000 1
Box terminal block, 3-pole 3-way dual box type terminal, contact safety device acc.to DIN VDE 0106 Part 100
spare part for contactors with box terminal block
LS 47 - LS 87 RKB 1 910-391 286-000 1
LS 107 - LS 147 RKB 2 910-391 276-000 1
b 177S (to 160A)
Flat plug terminal (16A) Flat plug 1 x 6.3 and 2 x 2.8, loose (Z-Nr. 220 128)
can be mounted on main all connections LS 4 - LS 17
and/or auxiliary terminals auxiliary terminals LS 27 - LS 307 910-392 367-000 1
F.25
AC contactors
Spare coils
For changing the operating voltages of existing contactors.
E.No. suffix see below.
E---No. voltage suffix - 910-... ...-XX0 for contactors type LS ... , and Type-/E-No. suffix for spare coils
F
AC-operation suffix -8C -85 -84 -8F -87 -88 -86 -8H -8K -69 -89 -64 -00 -81 -63 -83 -80 -82
50 Hz [V] 20 24 42 60 92 110 100 115 125 185 200 220 230 240 380 400 415 500
60 Hz [V] 24 28 48 70 110 125 115 150 220 230 255 265 280 440 460 475 575
AC-operation suffix -75 -62 -7A -77 -78 -76 -7B -7C -7D -79 -7E -74 -71 -7F -73 -70 -72
m m m m m m m m m m m m m m m m m
0.75 US-coil 50 Hz [V] 24 42 60 92 110 100 115 125 185 200 220 230 240 380 400 415 500
60 Hz [V] 28 48 70 110 125 115 150 220 230 255 265 280 440 460 475 575
AC-operation suffix -55 -54 -57 -58 -56 -5C -68 -5D -50 -51 -5E -59 -53
Double frequency coil 50/60 Hz [V] 24 42 48 110 115 120 200 220 230 240 380 400 440
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
Ordering example
for contactors: Contactor type LS 4.10 with e.g. DC-coil 220V E-Nr 910-302 701-190
for spare coils: AC-coil for type LS 4.10 with coil 24V 50Hz E-Nr 910-396 166-850
For spare coils from table with designation m a price increase has to be considered.
(2) AC-operated contactors with electronic coil control device ELSA only for type: LS 147, LS 207, LS 307, LS 407, LS 507, LS 637
(3) DC-operated contactors with electronic coil control device ELSA only for type: LS 407, LS 507, LS 637
Contactor combinations
Power rating [kW],
AC-3, 3~
230V 400V 690V Combination Contactors Designation E-No. Pack.
Without push-buttons
2.2 - 4 4 - 7.5 5,5 - 10 Lbi 4K - 7K LS 4K - 7K I01K6O IP65 910-304 703-000 1
Without push-buttons
7.5 11 15 Lbi 11K LS 11K I02K6O IP65 910-304 709-000 1
F
Neutral wire terminal
for I01K... and I02K... IKNL 910-304 719-000 10
Auxiliary contact block I (Start) For mounting on the front of the contactor
for I01K... and I02K... as spare part Operation via Start/I button on enclosure IKHT 910-304 721-000 10
F.27
Contactor combinations
Reversing contactor - AC operation 230V 50Hz
Please note the new LSCompact-Contactors with extensive, modular accessories
The digits of designation e.g. 47 for LUV 47 refer to the used single contactors e.g. LS 47.
Deviating operation voltages see table E-No. voltage suffix:
LUV 07 see page F.4 (contactor LS 07) AC-operation between 24 V and 400 V. (0.75% coils double frequency and DC coils are not
available for LUV 07
Type LUV 47 - 107, 177, 247 AC-operation between 24 and 500 V see page F.26
LUV 147, 207, 307 AC-operated with ELSA (electronic coil control device) see page F.26
F Ordering example: Reversing contactor type LUV 47.22 with e.g. coil 24 V 50 Hz E-No. 910-307 330-850.
(1) Also available with integrated electrical interlocking: LUV 18E: 910-304-602, LUV 55E: 910-304-603, see page F.18
(2) LS 220K and LS 280K only with type LUV 375H (horizontal)
(3) Auxiliary switch HS 107/LUV for exchange against the existing auxiliary switches on contactors and
adjustment plates for tolerance adjustment of the lock device swivel lever.
F.28
Contactor combinations
Star-delta starter type LSD
Power rating [kW], Rated current
AC-3, 3~ AC3, Ie, 400V
Contactor combinations
Main,
230V 400V 500V 690V Delta Star Type E-No. Pack.
Accessories
LSD-starter combinations Description
Terminal cover
LSD 4 - 107 main connections from LSD 47 with D-terminals integrated
LSD 177 main connections from contactor LS 177 see page F.25
LSD ...-enclosures
on request
F.29
Auxiliary contactors
Mini, compact, SH- contactors
Rated Rated AC operation DC operation
DIN EN 50
current [A] current [A] 230V 50Hz 24V DC
011
AC-14/15 DC-13
230V 24V Design no. Designation E-No. E-No. Pack.
F.30
Auxiliary contactors
Coupling relays (interface)
For operation on electronic controls, only available for 24V DC operating voltage
screw terminal
Rated Rated DC operation
DIN EN 50
current [A] current [A] 24V DC
011
AC-14/15 DC-13
Auxiliar y contactors
Power consumption at
230V 24V Design no. 24V DC Designation E-No. Pack.
8 contacts SH 8-relay
10 10 44E SH 8.44 (V/bZ)(2) 910-302 565-000 910-302 750-000 1
10 10 53E SH 8.53 (Diode)(4) - 910-302 952-000 1
10 10 53E SH 8.53 (V/bZ)(2) 910-302 592-000 910-302 763-000 1
10 10 62E SH 8.62 (Diode)(4) - 910-302 769-000 1
10 10 62E SH 8.62 (V/bZ)(2) 910-302 595-000 910-302 770-000 1
10 contacts SH 10-relay
10 10 55E SH 10.55 (V)(2) 910-302 809-000 - 1
10 10 55E SH 10.55 (V)(2) 910-302 810-000 - 1
10 10 73E SH 10.73 (V/bZ)(2) 910-302 829-000 910-302 878-000 1
10 10 82E SH 10.82 (V)(2) 910-302 830-000 - 1
4 contacts SH 4-relay
with integrated suppression element(3) 10 10 22E SH 4.22 910-302 727-000 1
8 contacts SH 8-relay
with integrated suppression element(3) 10 10 44E SH 8.44 910-302 759-000 1
(1) AC-operated with integrated varistor (V), with E-No. end digit -850 also available for 24V 50Hz.
DC-operated with integrated diode (D).
(2) AC-operated with integrated varistor (V), with E-No. end digit -840 also available for 42V 50Hz.
DC-operated with integrated bidirectional Z-diode (bZ) only DC 24V.
(3) With integrated suppression element, 4 pole, delayed off for safety relays see wiring diagram of type SAC 8.
(4) DC-operated with integrated diode, only DC 24V available.
F.31
Auxiliary contactors
Accessories - compact contactors type SH 05
Attachable to relay DIN
Description type LS 02K, LS 05 EN... Designation E-No. Pack.
Diode
US = 6 - 240V DC Any design no. EB 05 910-393 113-000 10
F.32
Auxiliary contactors
Accessories - contactors type SH 04, SH4 - SH 10
Attachable to relay
Description type ... Designation E-No. Pack.
Auxiliary switch, 1 contact Screw terminal, for front snap-on mounting on SH 4-relay
for front snap-on mounting max. 3 pieces snap-on SH 4 (single tier) HS 17.10 (1NC) 910-392 108-000 10
Auxiliar y contactors
HS 17.01 (1NO) 910-392 109-000 10
HS 17V.10 (1Sp.-NO) 910-392 112-000 10
HS 17V.01 (1Fr.-NC) 910-392 110-000 10
Push-button HT only for manual operation HT 17.10 (Tast., 1NC) 910-392 111-000 10
Flat plug terminal (16A) Flat plug 1 x 6.3 resp. 2 x 2.8, loose
for fixing auxiliary terminals Auxiliary terminals (Z-Nr 220 128) SH 4, SH 8, SH 10 910-392 367-000 1
(1) The assembly contains 3 clamping brackets for combination of 2 relays of the same size of DIN rail mounting.
screw mounting interlocking of 2 contactors of different size possible.
F.33
Auxiliary contactors
Accessories - contactors type SH 5
OFF-delay
0.1 - 30s TMI 30 910-304 572-000 10
1 - 60s TMI 60 910-304 573-000 10
F.34
Auxiliary contactors
Accessories - contactors type SH 5
Auxiliar y contactors
directly connected parallel Ue 48V IM 1K (BILRE) 910-304 605-160 5
to the coil terminals A1/A2 without cable
With relay and direct switch-on
possibility
Ue 24V IM 2K (BILRMD) 910-304 606-150 5
Over semiconductor
Ue 24V IM 3K (BILSD) 910-304 607-150 5
Interlock Mechanical
for side mounting LUV18K 910-304 600-000 5
Mechanical/ electronical
2NO (NC) LUV18E 910-304 602-000 5
F.35
E-No. voltage suffix 910-... ...-XX0 for control relays type SH 05 and type-/ E-No. suffix for spare coils
AC-operation suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -89 -00 -8P -63 -80 -82
50 Hz [V] 24 42 48 110 115- 200 220- 380- 415- 500
127 240 400 440
60 Hz [V] 24 48 60 110 115 120 208- 230 240- 380 440 480 600
220 277
AC-operation suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
Double frequency coil 50/60 Hz [V] 24 42 48 110- 120 200 220 230 240 400 440
115
DC-operation suffix -1A -1B -00 -1C -1D -1E -16 -17 -1F -18 -1G -14 -19 -1J -20
(Maximum coil voltage m m m m m m m m m
only 250V/DC) DC [V] 6 12 24 32 36 42 48 60 72 110 120 125 220 240 250
Ordering example
Contactors
for spare coils: Spare coil for type SH 05 e.g. 24V 50Hz type C 130-85, E-No 910-393 130-850
For spare coils from table with designation m a price increase has to be considered.
E-No. voltage suffix 910-... ...-XX0 for control relays type SH 5 and type-/ E-No. suffix for spare coils
AC-operation suffix -8C -85 -84 -8E -87 -86 -88 -8K -69 -8M -00 -81 -8P -63 -83 -80 -82 -8S
50 Hz [V] 24 42 48 110 127 208 220- 240 380 380- 415 500 660-
240 400 690
60 Hz [V] 24 48 110 115 120 220 240 277 380 440 480 600
AC-operation suffix -55 -54 -57 -56 -5C -68 -5D -50 -51 -59 -53
Double frequency coil 50/60 Hz [V] 24 42 48 110- 120 200 220 230 240 400 440
115
DC-operation suffix -1A -1B -00 -1C -1D -1E -16 -17 -1F -18 -1G -14 -19 -1H -1J -20 -1K
m m m m m m m m m m m
DC [V] 6 12 24 32 36 42 48 60 72 110 120 125 220 230 240 250 440
Ordering example
for spare coils: Spare coil for type SH 05 e.g. 24V 50Hz type C 130-85, E-No 910-393 130-850
For spare coils from table with designation m a price increase has to be considered.
E-No. voltage suffix 910-... ...-XX0 for control relays type SH 04, SH 4, SH 8, SH 10 and spare coils (1)
AC-operation suffix -8C -85 -84 -8F -87 -88 -86 -8H -8K 69 -89 -64 0 -81 -63 -83(1) -80(1) -82(1)
50 Hz [V] 20 24 42 60 92 110 100 115 125 185 200 220 230 240 380 400 415 500
60 Hz [V] 24 28 48 70 110 125 115 150 220 230 255 265 280 440 460 475 575
F AC-operation suffix -75 -62 -7A -77 -78 -76 -7B -7C -7D -79 -7E -74 -71 -7F -73(1) -70(1) -72(1)
m m m m m m m m m m m m m m m m m
0.75 US-coil 50 Hz [V] 24 42 60 92 110 100 115 125 185 200 220 230 240 380 400 415 500
60 Hz [V] 28 48 70 110 125 115 150 220 230 255 265 280 440 460 475 575
AC-operation suffix -55 -54 -77 -58 -56 -68 -5D -50 -51 -5E -59 -53
Double frequency coil 50/60 Hz [V] 24 42 48 110 115 200 220 230 240 380 400 440
Ordering example
for spare coils: Spare coil for type SH 4 e.g.coil 24V 50Hz E-No. 910-396 166-850
Price increase: For spare coils from table with designation m a price increase has to be considered.
(1) SH 04 not for voltages above AC 440V resp. DC 180V
Remark: Use suffix only with E-No. of the basic execution, e.g. suffix for DC only with contactors with DC-coil on the lable of the contactors, you will find the suffix
according to above table, e.g. 24 V, 50 Hz = suffix -85.
On invoices / order confirmations etc. from our system, the suffix has 3 digits, end digit = 0, e.g. suffix is -850.
F.36
System compact contactors System LSK contactors up to 55 kW
Auxiliar y contactors
Compact contactors type LS 02K, LS 05 Contactors type LS 4K up to LS 55K
O
1 contactor O
1 contactor
O
2 aux. contact block for side mounting O
2 aux. contact block for side mounting
O
3 aux. contact block for front mounting O
3 mechanical interlock
O
4 overvoltage suppressor O
4 aux. contact block for front mounting
O
5 timer, electronic O
5 timer, electronic
O
6 thermal overload relay O
6 overvoltage suppressor
O
7 mechanical latch
O
8 timer, pneumatic
O
9 thermal overload relay
F
System LSK-contactors from 75 kW
up to 450 kW
F.37
Small soft starter with integral by-pass
ASTAT S
ASTAT S is compact, easy to operate soft starter, designed for use with
standard 3-phase squirrel cage motors. It provides an advanced method
of reducing current during motor starting and stopping.
ASTAT S will start supplying a reduced voltage to the motor, increasing up
to the rated voltage, so avoiding, high currents and generating soft
starting and stopping.
Soft starters
Marking Specifications
Ratings
Voltage ratings 3ph AC systems
380/415V (+10%, -15%) for units QS12P _ _ _ S
480/500V (+10%, -15%) for units QS22P _ _ _ S
575/600V (+10%, -15%) for units QS32P _ _ _ S
Frequency range 50/60Hz (5%)
Load 3ph, AC standard motors
Control specifications
Ramp up 0,5 - 5 s
Ramp down 0,5 - 5 s
F
Initial voltage 0 - 80% Un
Starting torque 0 - 64% Tn
I/O control
Imputs one input for Start/Stop
Outputs one output for End of Ramp signal
for ratings 31, 44, 58A
Ambient conditions
Operating temperature 0 ... 40C. Up to 60C derating by 1,2% per C
Storage temperature -20 ... 70C
Relative humidity up to 80%, without condensation
Max. altitude up to 1000m.
Above this derate by 5% each 100m
Protection degree IP20
F.38
A STAT S
17 60 - 11 / 15 - QA22P017S 120899 1
22 77 - 15 / 20 - QA22P022S 120900 1
31 110 - 22 / 30 - QA22P031S 120901 1
44 150 - 30 / 40 - QA22P044S 120902 1
58 200 - 45 / 60 - QA22P058S 120903 1
Accessory DIN rail mounting kit for types 31A, 44A and 58A QAOPTDIN 120910 1
Further technical data: see our catalogue Control and Automation 680804.
F.39
ASTAT SD
Solid state soft starter for 3ph motors up to 20kW
Working voltage up to 500VAC
Built-in with analogue operation panel
Three pase - full wave control (6 thyristors)
Soft starters
F.40
Ambient conditions
Temperature 0 to +55C
(derate output current by 1.5% / C above 45C)
Relative humidity 95% without condensation
Maximum altitude 3000 m
(derate output current by 1% / 100 m above 1000 m)
Mounting position Vertical
Description of the terminals
1L1, 3L2, 5L3 Power supply (max. 440V or 500V depending type)
A STAT SD
2T1, 4T2, 6T3 Outputs to motor
A1/A2, B1/B2 Command supply inputs (110/120V - 220/240V AC)
11, 14 Internal relay output Run / End of ramp (1NO)
1, 57 Run command input
2, 57 Stop command input
Output contacts specifications
Maximum usage voltage 380V CA
Thermal current Ith 8A
Usage specifications
AC15 220V / 3A - 380V / 1A
DC15 Max. 30V / 3.5A
ASTAT SD
IEC Ratings Current Maximum Light duty Heavy duty Cooling Cat. No. Ref. No.
rating starting (3 x Ir, 30sec.) (4.5 x Ir, 30sec.) convection
Ir current 220V 380V 440V 480V 220V 380V 440V 480V
240V 415V 500V 240V 415V 500V
A A kW kW kW kW kW kW kW kW
F
Input voltage 5 25 1.1 2.2 2.2 1.1 2.2 2.2 Natural QS1BNA 120460
220 - 440 VCA 9 45 2.2 4 4 2.2 4 4 Natural QS1DNA 120462
+ 10%, -15% 12 60 3 5.5 6.3 3 5.5 6.3 Natural QS1FNA 120464
48 < f (Hz)< 62 16 80 4 7.5 7.5 3.7 6.3 7.5 Natural QS1GNA 120466
22 110 5.5 11 11 5.5 11 11 Natural QS1HNA 120468
34 170 7.5 15 18.5 7.5 15 17 Natural QS1INA 120470
Input voltage 5 25 1.1 2.2 2.2 3 1.1 2.2 2.2 3 Natural QS2BNA 120461
220 - 500 VCA 9 45 2.2 4 4 5.5 2.2 4 4 5.5 Natural QS2DNA 120463
+ 10%, -15% 12 60 3 5.5 6.3 7.5 3 5.5 6.3 7.5 Natural QS2FNA 120465
48 < f (Hz)< 62 16 80 4 7.5 7.5 10 3.7 6.3 7.5 10 Natural QS2GNA 120467
22 110 5.5 10 11 13 5.5 10 11 13 Natural QS2HNA 120469
34 170 7.5 15 18.5 20 7.5 15 15 20 Natural QS2INA 120471
UL Ratings Current Maximum Light duty Heavy duty Cooling Cat. No. Ref. No.
rating starting (3 x Ir, 30sec.) (4.5 x Ir, 30sec.) convection
Ir current 200V 230V 460V 200V 230V 460V
A A Hp Hp Hp Hp Hp Hp
Input voltage 5 25 1 1 1 1 Natural QS1BNA 120460
200 - 230 V 9 45 2 2 2 2 Natural QS1DNA 120462
12 60 3 3 3 3 Natural QS1FNA 120464
16 80 3 5 3 5 Natural QS1GNA 120466
22 110 5 7.5 5 7.5 Natural QS1HNA 120468
34 170 10 10 7.5 7.5 Natural QS1INA 120470
Further technical data: see our catalogue Control and Automation 680804.
F.41
ASTATplus
Solid state soft starter for 3ph AC motors up to 850 kW
Three pase - full wave control (6 thyristors)
Working voltage up to 500V
Built-in digital operation panel
Soft starters
F.42
A STATplus
1 analogue 0-10V DC output for current metering
Communications ASCII and Modbus RTU as standard
Profibus DP and DeviceNet as option external modules
Protections
Current limit Adjustable from 1xln to 7xln
Overload Class IEC 10 and 20 (selectable)
Class NEMA 10, 20 and 30 (selectable)
OFF desactivado
Cool-down time after
overload trip 300 s for reset
Loss on input phase Trip at 3 s
Thyristor shortcircuit Trip at 200 ms
Heatsink overheating Trip at 200 ms
Motor thermistor Trip at 200 ms
Loss on output phase Trip at 3s
Stalled rotor Trip at 200 ms
Supply frequency error Si f < 45Hz f > 65 Hz
Overcurrent 100 to 150% ln; trip time adjustable from 0 to 99s
Undercurrent 0 to 99% ln; trip time adjustable from 0 to 99s
Overvoltage 100% to 130% Un; trip time adjustable from 0 to 99s F
Undervoltage 0 to 50% Un; trip time adjustable from 0 to 99s
Error (CPU) 60ms
Memory 4 former errors
Long start time 2 x ta ( ta= acceleration ramp time)
Long slow speed time 120s
Ambient conditions
Temperature 0 to +55 C
(derate output current by 1.5% /C above 40C)
Relative humidity 95% without condensation
Maximum altitude 3000 m
(derate output current by 1%/100m above 1000m)
Mounting position Vertical
Protection degree IP 00, (UL open)
Standards
CE, cUL, UL CE conforming IEC 947-4-2
UL, cUL conforming UL 508
Conducted and radiated Conforming IEC 947-4-2, Class A
emissions
Electrostatic discharges Conforming IEC 1000-4-2, level 3
Radioelectric interferences Conforming IEC 1000-4-6, level 3 and
to IEC 1000-4-3, level 3
Inmunity to fast trasients Conforming IEC 1000-4-4, level 3
Inmunity to surge voltage Conforming IEC 1000-4-5, level 3
Further technical data: see our catalogue Control and Automation 680804.
F.43
374.4 1080 288 80 150 165 - 240 63 110 132 - by fan QC1QDP 129746
491.4 1417.5 378 110 200 220 - 315 90 160 200 - by fan QC1RDP 129748
577.2 1665 444 132 220 250 - 370 110 200 220 - by fan QC1SDP 129750
741 2137.5 570 160 300 355 - 475 150 250 250 - by fan QC1TDP 129752
951.6 2745 732 220 400 450 - 610 200 315 400 - by fan QC1UDP 129754
1326 3825 1020 300 560 600 - 850 250 450 530 - by fan QC1VDP 129756
1677 4837.5 1290 395 715 750 - 1075 355 600 670 - by fan QC1XDP 129758
Input voltage 21.8 63 17 4 7.5 7.5 11 14 3 5.5 7.5 7.5 natural QC2FDP 129729
26.5 76.5 21 5.5 11 11 13 17 4 7.5 7.5 11 natural QC2GDP 129731
220- 500V 34.3 99 27 7.5 13 15 15 22 5.5 11 11 15 natural QC2HDP 129733
+ 10%, -15% 49.9 144 38 10 18.5 22 25 32 7.5 15 18.5 22 natural QC2I DP 129735
45 < f (Hz)< 65 74.8 216 58 15 25 30 37 48 13 22 22 30 by fan QC2JDP 129737
98.2 283.5 75 22 37 45 45 63 15 30 37 37 by fan QC2KDP 129739
112.3 324 86 25 45 50 50 72 20 37 37 45 by fan QC2LDP 129741
163.8 472.5 126 37 63 75 80 105 30 55 55 75 by fan QC2MDP 129743
243.3 702 187 55 90 110 132 156 40 75 90 110 by fan QC2NDP 129745
374.4 1080 288 80 150 165 200 240 63 110 132 160 by fan QC2QDP 129747
491.4 1417.5 378 110 200 220 250 315 90 160 200 220 by fan QC2RDP 129749
577.2 1665 444 132 220 250 315 370 110 200 220 250 by fan QC2SDP 129751
741 2137.5 570 160 300 355 400 475 150 250 250 335 by fan QC2TDP 129753
951.6 2745 732 220 400 450 500 610 200 315 400 400 by fan QC2UDP 129755
1326 3825 1020 300 560 600 750 850 250 450 530 600 by fan QC2VDP 129757
1677 4837.5 1290 395 715 750 850 1075 355 600 670 750 by fan QC2XDP 129759
UL Ratings Current Max. Light duty Heavy duty Cooling Cat. No. Ref. No.
rating starting (3 x Ir, 30 sec.) (4.5 x Ir, 30 sec.) convection
Ir current 200V 230V 460V 200V 230V 460V
A A Hp Hp Hp Hp Hp Hp
Input voltage 14 70 3 3 - 3 3 - natural QC1FDP 129728
200- 230 V 17 85 3 3 - 3 3 - natural QC1GDP 129730
22 110 5 7.5 - 5 7.5 - natural QC1HDP 129732
F 34 170 10 10 - 7.5 7.5 - natural QC1I DP 129734
48 240 15 15 - 10 15 - by fan QC1JDP 129736
63 315 20 20 - 15 20 - by fan QC1KDP 129738
72 360 20 25 - 20 20 - by fan QC1LDP 129740
105 525 30 30 - 30 30 - by fan QC1MDP 129742
156 780 50 60 - 40 50 - by fan QC1NDP 129744
240 1200 75 75 - 60 75 - by fan QC1QDP 129746
315 1575 100 125 - 75 100 - by fan QC1RDP 129748
370 1850 125 150 - 100 125 - by fan QC1SDP 129750
500 2500 150 200 - 150 150 - by fan QC1TDP 129752
630 3150 200 250 - 200 200 - by fan QC1UDP 129754
850 4250 300 350 - 250 300 - by fan QC1VDP 129756
F.44
Digital inputs
57 Common for digital inputs This is a common terminal for the digital input terminals specified below
A STATplus
1 Run Run order. Command signal may be provided by one NO dry momentary contact to terminals 1 and 57
2 Stop Stop order. Command signal may be provided by one NC dry momentary contact to terminals 2 and 57
NOTE: Run/Stop permanent command is allowed linking 1-57 and using one dry NO contact to 2-57
terminals
3 Programmable input I3 These two inputs are programmable. Can be assigned to the following internal functions:
4 Programmable input I4 - soft stop - DC brake - linear ramp
- pump control - slow speed control - dual ramp selection
- kick start - reverse slow speed - by-pass function
- override - local / remote control
Command signal should be provided by one NC dry contact to terminals 57-3 or terminals 57-4.
By switching this contact ON/OFF it is possible to enable or disable the assigned function.
Digital outputs
11, 12, 14 Programmable relay 1r 11-12 = NC, 11-14 = NO dry contacts
This relay can be assigned to several internal output functions. As default assigned to function RUN.
23, 24 Programmable relay 2r 23-24 = NO dry contact
This relay can be assigned to several internal output functions. As default assigned to function EOR.
33, 34 Programmable relay 3r 33-34 = NO dry contact
This relay can be assigned to several internal output functions. As default assigned to function DC BRAKE
Common for all relay output contacts: Max. usage voltage: 380V AC (B300 - UL)
Thermal current Ith: 8A
AC-15: 220V / 3A, 380V / 1A
DC-15: 30V max. / 3.5A
Programmable relays can be assigned to following functions:
- End of Ramp - RUN
- DC brake - Slow speed
- Fault - Undercurrent
- Undervoltage - Overcurrent
- Overvoltage
F
Analogue I/O
8 Analog input common (-) This is a common terminal for the analogue input terminal 7 and analogue output terminal 9
7 TG feedback input (+) 0-5V analogue input for speed feedback. It should be provided by a DC tacho-generator coupled to motor.
This speed feedback signal is required when the linear ramp function is used.
9 Current output (+) 0-10VDC analog output for current measurement purpose. Ir correspond to 2Vdc. Rated current is 2VDC.
Load impedance 10k or higher.
Communications
SG, TD, RD Gr, Tx, Rx data - RS232C, 3 wires, half duplex. Maximum cable lengths 3m (10 feet)
- Asynchronous data transmission, 9600 Bauds, 1 bit start, 8 bits data, 1 bit stop, no parity
- Supported ASCII and ModbusRTU (selectable by the user)
- Optional Device Net and Profibus DP external modules
Further technical data: see our catalogue Control and Automation 680804.
F.45
VAT20
Single-phase or three-phase digital inverters for controlling the speed of
three-phase induction AC motors from 0.2 to 2.2kW
Built-in keypad and display
IP20 or IP65 protection degree
Built-in EMC filter for industrial environment (class A)
DIN rail mountable by optional kit
Global standards CE and cUL
Control specifications
Control system Sinusoidal wave PWM inverter
Output frequency 0 - 200Hz
Voltage / Frequency Constant torque, Constant power, Torque boost
Six selectable pre-set patterns
Overload capacity 150%, 60 sec.
Carrier frequency Selectable 4 - 16kHz
Frequency setting resolution
Digital 0.1Hz(0-99.9Hz), 1Hz(100-200Hz)
Analogic 0.1Hz/ 60Hz
Acceleration/deceleration 0.1 - 999 sec.
Acceleration and deceleration set individually
Operating system Two mode selection: forward run by FWD input, Reverse run by REV
F input Run by FWD input, forward/reverse command by REV input
Stopping system Selectable either ramp down or coast to stop
DC braking DC brake starting frequency 1-10Hz
DC braking level 0-20%, DC braking time 0-25.5s
Frequency limit Upper limit (1-200Hz), lower limit (0-200Hz)
Other functions Auto re-start, Auto reset, Flying start, Jog, Slow speeds
I/O configuration
Operation panel 3 digits, 7 segment display with 5 operation keys
Sequence input Four digital inputs (2 are programmable)
Sequence output One programmable relay output
Frequency setting input One analogue either 0-10V, 4-20mA or 0-20mA configurable
Source for potentiometer 10VDC source for 2-10k potentiometer
Analogue outputs 0-10VDC for frequency output display
Protection features
Prevention Overcurrent limitation, Overvoltage limitation, Stall prevention
Trip Overload, Overvoltage, Undervoltage, Overcurrent, Powerloss,
Output shortcircuit, Grounding fault, Overtemperature
Fault history The last three faults are recorded
Operating environment
Installation Indoor, with atmosphere free from corrosive or explosive gases,
dust, steam or oil mist.
Protection degree IP20 and IP65
Temperature range from -10 to 50 C
Relative humidity 0-95% without condensation
Vibrations Under 1G (9.8 m/s2)
Standards cUL, CE
F.46
1ph / 3ph 2.9 7.5 1.5 forced 103 IP20 U20N1K5S (2) 167078 1
200V - 240V 4.0 10.5 2.2 forced 149 IP20 U20N2K2S (2) 167079 1
VAT20
3ph 1.6 2.3 0.75 forced 61 IP20 U20X0K7S (2) 167080 1
2.9 3.8 1.5 forced 79 IP20 U20X1K5S (2) 167081 1
380V - 480V 4.0 5.2 2.2 forced 94 IP20 U20X2K2S (2) 167082 1
(1) Ratings for standard tree-pole induction motors with four poles
(2) Units including dynamic braking function. An external braking resistor is needed to perform operation
(3) IP65 models type U20_ _ P include only keypad in the front cover.
(4) IP65 models type U20_ _ PS include power switch, forward/reverse switch and potentiometer in the front cover
Further technical data: see our catalogue Control and Automation 680804.
F.47
VAT200
Advantages
Compact size
Built-in removable LED keypad
Optional multilanguage LCD keypad
Sensor-less Vector Control or V/f control, selectable
Built-in with ModBus RTU Communications
Approvals Optional Field bus communication DeviceNet, ProfibusDP
Integrated EMC filters for U20...FS series
Built-in with Dynamic Braking
C US Performed with simple PLC and PID functions
Programming software for Windows and WinCE
Keypad port
Serial port
Wiring
For Copy unit and Communications
Terminal cover removed by
just one screw
Configuration switches
- For analogue I/O
- For PNP/NPN digital input selection
I/O terminals
Supply and Motor
I/O terminals
Control
I/O terminal
DC reactor
F.48
VAT 200 - Codes
Input voltage Suitable motor Rated output Rated Frame Cat. No. Ref. No. Pack
+ 10%, -15%, 50/60 Hz ( 5%) capacity current capacity
(kW) (A) (KVA) (units)
VAT20
3ph Without EMC filter
200V - 240V 0,4 3,1 1,2 1 U203N00K4SS 167415 1
0,75 4,5 1,7 1 U203N00K7SS 167416 1
1,5 7,5 2,9 1 U203N01K5SS 167417 1
2,2 10,5 4 2 U203N02K2SS 167418 1
3,7 17,5 6,7 2 U203N04K0SS 167419 1
5,5 26 9,9 3 U203N05K5SS 167420 1
7,5 35 13,3 3 U203N07K5SS 167422 1
Frame 2
F.49
Weight (Kg) 1,3 1,3 1,8 2,3 1,2 1,2 1,2 1,75 1,9 5,6 5,6 1,3 1,3 2,2 2,2 6,6 6,6 6,6
Frequency control
Control mode V / f or Sensorless vector control
Frequency control Range 0,1 to 650,0Hz
Starting torque 150% / 1Hz (Sensorless vector)
Speed control range 1 : 50 (Sensorless vector)
Speed control accuracy 0,5% (Sensorless vector)
Setting resolution Digital: 0,01Hz
Analog: 0,06Hz / 60Hz (10 bits)
Keypad setting Set directly by keys or by potentiometer on the keypad
Display function Four digital LED (or 2x16 LCD) and status indicator; display frequency / speed / line speed /
DC voltage / output voltage / current / rotation direction / inverter parameter / trouble log /
program version
Frequency setting 1. External potentiometer / 0-5V / 0-10V / 4-20mA / 5-0V / 10-0V / 20-4mA
2. Performs up/down controls, speed control or automatic procedure control with multifunctional
contacts on the terminal block (TM2)
Frequency limit function Respectively setting upper/lower frequency limits and three-stage skip frequencies
Control
Carrier frequency 2 to 16kHz
F V / F pattern 18 fixable patterns, 1 programmable pattern
Acc./Dec. control Two-stage Acc./Dec. time (0,1 to 3.600 seconds) and two-stage S curve (refer to descriptions on 3-05)
Multifunctional analog output 5 different functions
Multifunctional input Assigned to 28 different functions
Multifunctional output Assigned to 15 different functions
Digital input signal NPN / PNP toggle
Other functions Momentary power loss restart, Speed search, Overload detection, Torque detection, 8 preset speeds,
Acc./Dec. switch (2 stages), S curve, 3-wire control, PID control, Torque boost, Slip compensation,
Frequency upper/lower limit, Auto energy saving, Modbus slave and control link, Abnormal restart,
Sequence control, Built-in simple PLC function
Others
Communication control - Control by RS232 or RS485
- One to one or Multilink up to 254 stations (RS485 only)
- Can be set Baud rate, Stop bit and Parity bit
Braking torque About 100% with Braking resistor (20% without braking resistor)
Operation temperature -10 to +50C
Storage temperature -20 to +60C
Humidity 0 to 95% relative humidity (without condensation)
Vibration 1G (9,8m/S2)
EMC Comply with requirement EN 61800-3 with optional filter
LVD Comply with requirement EN 50178
Enclosure IP20 (Nema 1 by external box attached)
Safety level UL 508C
Protective functions Overload protection Inverse characteristic overload protection. Max. 150% inverter current rating / 60 sec.
Fuse protection The motor stops after FUSE melt
Overvoltage 200V class: DC voltage > 410V 400V class: DC voltage > 820V
Undervoltage 200V class: DC voltage < 190V 400V class: DC voltage < 380V
Momentary power loss restart Restart after more than 15ms-power loss possible. Programmed up to 2 sec.
Stall prevention Stall prevention for Acceleration / Deceleration / Operation
Short-circuit output terminal Electronic circuit protection
Grounding fault Electronic circuit protection
Other protections Heatsink overtemperature, overtorque detection, error contact control, reverse run restriction, restrictions
for direct start after power up, error recovery and parameter lock out.
F.50
VAT200
Frame 1 & 2 Frame 3
A B C D E F G A B C D E F
U201N00K4 163 150 78 90 147 141 7 U203N05K5 260 244 173 186 195 188
U201N00K7 U203N07K5
U203N00K4 U203X05K5
U203N00K7 U203X07K5
U203N01K5 U203X11K0
U203X00K7
U203X01K5
U201N01K5 187 170,5 114,5 128 148 142 7
U201N02K2
U203N02K2
U203N04K0
U203X02K2
U203X04K0
Power terminals F
Power supply input L1, L2, L3
Motor output T1, T2, T3
DC Reactor P1, P
DB Resistor P, BR
Control terminals
Analog inputs Multifunction VIN
PID feedback S6
Analog outputs Multifunction FM
Digital inputs S1, S2, S3, S4, S5, S6 (dual use)
Digital outputs R1 (NO-NC dry relay contact)
R2 (NO dry relay contact)
F.51
Three phase variable speed drives
for AC motors
Micro variable speed drives
VAT2000
VAT2000 is a compact, maintenance free, reliable AC drive for three phase
220-240V or 380-460V power source, allowing high accuracy speed
control of standard AC motors.
Removable keypad
Other features
- Extended I/O range
- Advanced functions
- Autotuning
- Torque control
- Soft Sound
- PID control
- Multipump control
- Pattern run
- Programmable speeds
Approvals - Traverse function
- Skip frequency
- Speed ratio control
CE compliance
- S shape ramp
UL approval (UL508C) 400V series
- Communications
up to U2KX45K0S only.
- Built-in RS485 port
- Optional Profibus DP interface
F.52
Mode 1 Mode 3
V/F control for constant torque loads with advanced toruqe Sensorless vector control
control There are many drives which claim to offer sensorless vector
This mode uses auto-tuning to give voltage vector control in control but we feel that this term is misused and describes a
open loop. control system similar to our standard Advanced Torque Control.
The main features of this mode are: We define true Sensorless Vector Control as Flux Vector Control
1. Build-in PID controller eliminates the requirement, and cost, of without encoder. Closed loop vector control requires the use of
a separate device. an encoder so that shaft position can be used in order to
2. Tripless operation. This safe and convenient fetaure is a calculate and control phase angle and shaft speed. Because of
combination of: this, all settings within a closed loop environment relate to actual
- the availability of dinamically extend ramp times during shaft rotation rather than output frequency.
VAT2000
operation if the load is likely to demand a too high current or Developing a method whereby the shaft rotation can be
regenerate a higher current than the programmed limit. calculated by very closely monitoring the waveform and feedback
- automating limiting of the IGBT switching frequency if the at three output phases of the drive. All of the settings the
heatsink temperature rises too high. VAT2000 in sensorless vector mode are therefore set using
- the ability to limit current transients caused by shock loads. rotational speed and not output frequency.
- alarms and controlled shutdown in the event of a fault which In addition, incorporate two current loops to control magnetising
is non-life threatening of the drive motor. current independently. Thus, the VAT2000 can perform almost as
3. Motor Loss Brakingis a system which reduces motor well as a closed loop system and uniquely provide torque at zero
efficiency during regenerative braking allowing some of the speed.
braking energy to be dissipated from the motor as heat, so
reducing the size (or even eliminating) the brake resistor. Mode 4
F.53
VAT2000
DC supply drives for common bus operation
We can supply VAT2000 drives for common bus operation DC supply 270-360VDC or 520-720VDC.
Please ask your dealer for more information.
F.54
VAT2000
Encoder interface 12V A/B phase 60kHz; 6V single phase 20kHz, U2KV23DN1 168087
12VDC 100mA supply output
5V A/B phase differential 250kHz; 5VDC 200mA U2KV23DN2 168088
5VDC 100mA supply output
5V 6 phase (A, B, Z, U, V, W) 250Hz for permanent U2KV23DN3 168089
magnet motors
5VDC 100mA supply output
Parallel interface Frequency setting through parallel 8/12/16 data bits U2KV23PI0 168091
Accessories
Extension cable for keypad 3m U2KV23W103 168102
Extension cable for keypad 1m U2KV23W101 168103
Drive to terminals RS485 cable U2KV23W123 168104
Drive to 15 pin D-sub connector U2KV23W113 168105
RS485 cable
Drive to PC RS232 cable Includes RS232/485 converter U2KV23CNVKIT 168106
Further technical data: see our catalogue Control and Automation 680804.
F.55
F.56
VAT2000
Frequency jump Up to three areas / Width can be varied between 0.0 and 10Hz
Slip compensation Slip compensation gain for V/f operation only from 0.0 to 20.0%
Auto-run function 10-step automatic run function / Synchronous / Asynchronous selective
Others PID, Pick-up, Auto-start, Traverse, Multipump control, reverse run protection and Restart
after instantaneous power failure
External I/O
Operation keypad Detachable IP54 unit with 5 digit LED display and eight status LED signals.
Includes three set keys and fast tuning knob system.
Door mountable by 3m extension cable
Input sequence Three fixed inputs and five programmable to more than 30 functions
Output sequence One fixed dry contact (fault), one dry contact and three open collector outputs all
programmable to more than 20 functions, like speed detection precharging, reverse run,
speed reached, direction, current reached, speed, acceleration, fault code, etc
Frequency settings FSV: 0 to 10V / 0 to 5V / 1 to 5V
FSI: 4 to 20mA / 0 to 20mA
AUX: 0 to 10V / 0 to 5V / 1 to 5V
Source potentiometer: 10V DC (2k2Ohms)
Meter outputs Two 0-10V programmable with output frequency, voltage, current, DC voltage, etc
Protection features F
Prevention Overcurrent and Overvoltage limit, Overload warning signal
Trip Overcurrent, overvoltage, undervoltage, IGBT fault, overload, temperature rise, ground
fault, other self-diagnosis
Fault history The last four faults are recorded including in each:
main cause, secondary cause, output current and output frequency at the fault time
Overload level CT: 150% for 1 minute, 170% for 2,5 seconds
VT: 120% for 1 minute, 125% for 1second
For frequencies below 1Hz, overload of 75% during 60 seconds
Retry Automatic reset after a fault. Adjusable from 0-10 tries
Operating environment
Installation Indoor, with atmosphere free from corrosive or explosive gases, dust, steam or oil mist
Working temperature -10 to +50C
Relative humidity max. 95% RH, non condensing
Altitude 1000 m. max.
Vibrations 4.9 m/s2
Further technical data: see our catalogue Control and Automation 680804.
F.57
F.58