Vous êtes sur la page 1sur 8

Job No Sheet No Rev

chs 1
Part
Software licensed to
Job Title Ref

By Date16-Nov-16 Chd

Client File DRDL-STD-GES-STAAD- Date/Time 06-Mar-2017 11:42

Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 2834 222:1.2DL+1.2L 10.298 132.991 -11.102 0.000 0.000 0.000
Min FX 2834 221:1.2DL+1.2L -8.335 -20.576 2.258 0.000 0.000 0.000
Max FY 2834 222:1.2DL+1.2L 10.298 132.991 -11.102 0.000 0.000 0.000
Min FY 2834 221:1.2DL+1.2L -8.335 -20.576 2.258 0.000 0.000 0.000
Max FZ 2834 221:1.2DL+1.2L -8.335 -20.576 2.258 0.000 0.000 0.000
Min FZ 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
Max MX 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
Min MX 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
Max MY 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
Min MY 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
Max MZ 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
Min MZ 2834 201:1.4DL+1.4W 3.294 51.549 -11.469 0.000 0.000 0.000
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 1
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

Specifier's comments: Tension & shear Reinforcement should be provided.

1 Input data
Anchor type and size: Hex Head ASTM F 1554 GR. 55 1 1/4
Effective embedment depth: hef = 250 mm
Material: ASTM F 1554
Technical Information: Design Method ACI 349/CIP
Issued I Valid: -|-
Proof: Design Provisions of ACI349-01, Appendix B
Stand-off installation: without clamping (anchor); restraint level (baseplate): 2.00; eb = 20 mm; t = 20 mm
Hilti Grout: , multipurpose, fc,Grout = 30.00 N/mm2
Baseplate: lx x ly x t = 300 mm x 270 mm x 20 mm; (Recommended plate thickness: not calculated
Profile: Pipe; (L x W x T) = 168 mm x 168 mm x 7 mm
Base material: uncracked concrete, , fc' = 5802 psi; h = 500 mm
Reinforcement: anchor reinforcement: tension #SIZE# #GRADE#, shear #SIZE# #GRADE#
edge reinforcement: > No. 4 bar with stirrups
Anchor Design Option B.3.6.1

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 2
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads
1 2
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 3.868 5.413 5.032 1.994
2 3.868 6.133 5.032 3.506 x
3 6.632 7.357 6.468 3.506
Tension
4 6.632 6.768 6.468 1.994
max. concrete compressive strain: - []
max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/-25): 21.000 [kN] 4 3
resulting compression force in (x/y)=(0/0): 0.000 [kN]

3 Tension load
Load Nu [kN] Capacity f Nn [kN] Utilisation bN = Nu/f Nn Status
Steel failure* 6.632 323.274 3 OK
Pull-out failure* 6.632 446.395 2 OK
Concrete cone failure** 1 N/A N/A N/A N/A
Concrete side-face blowout, direction y-** 13.263 203.778 7 not recommendedA
* most unfavourable anchor **anchor group (anchors in tension)
1
Tension Anchor Reinforcement has been selected!
A
When B.3.6.1 is selected as the anchor design option, the design steel strength must be the governing design strength having the highest
utilisation.

3.1 Steel failure


Ns = n Ase fut ACI 349-01 Eq. (B-3)
f Nsteel Nu ACI 349-01 Eq. (B-1)

Variables
n Ase [mm2] fut [N/mm2]
1 625 517.11
Calculations
Ns [kN]
323.274
Results
Ns [kN] f steel f Ns [kN] Nu [kN]
323.274 1.000 323.274 6.632

3.2 Pull-out failure


Npn = y 4 Np ACI 349-01 Eq. (B-9)
Np = 8 Abrg f'c ACI 349-01 Eq. (B-10)
f Npn Nu ACI 349-01 Eq. (B-1)

Variables
y4 Abrg [mm2]
1.400 1172
Calculations
Np [kN]
375.122
Results
Npn [kN] f concrete f Npn [kN] Nu [kN]
525.170 0.850 446.395 6.632

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 3
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

3.3 Concrete side-face blowout, direction y-


Nsb = 160 c Abrg f'c ACI 349-01 Eq. (B-11)
Nsbg = agroup Nsb ACI 349-01 Eq. (B-12)
f Nsbg Nu ACI 349-01 Eq. (B-1)

(
agroup = 1 + 0
s
6c ) see ACI 349-01, Part B.5.4.2 Eq. (B-12)

Variables
c [mm] c2 [mm] Abrg [mm2] f'c [psi] s0 [mm]
50 100 1172 5802 200
Calculations
agroup Nsb [kN]
1.667 143.844
Results
Nsbg [kN] f concrete f Nsbg [kN] Nu,edge [kN]
239.739 0.850 203.778 13.263

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 4
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

4 Shear load
Load Vu [kN] Capacity f Vn [kN] Utilisation bV = Vu/f Vn Status
Steel failure* 7.357 210.128 4 OK
Steel failure (with lever arm)* 7.357 83.262 9 OK
Pryout failure** 25.495 156.399 17 not recommendedA
Concrete edge failure in direction **1 N/A N/A N/A N/A
* most unfavourable anchor **anchor group (relevant anchors)
1
Shear Anchor Reinforcement has been selected!
A
When B.3.6.1 is selected as the anchor design option, the design steel strength must be the governing design strength having the highest
utilisation.

4.1 Steel failure


Vs = n 0.65 Ase fut refer to ACI 349-01, B.3.6.1
f Vsteel Vu ACI 349-01 Eq. (B-2)

Variables
n Ase [mm2] fut [N/mm2]
1 625 517.11
Calculations
Vs [kN]
210.128
Results
Vs [kN] f steel f Vs [kN] Vu [kN]
210.128 1.000 210.128 7.357

4.2 Steel failure (with lever arm)


aM Ms
VM
s = bending equation for stand-off
Lb
Ms (
= M0s 1 - u
N
f Ns ) resultant flexural resistance of anchor
M0s = (1.2) (S) (fu,min) characteristic flexural resistance of anchor

( N
1- u
f Ns ) reduction for tensile force acting simultaneously with a shear force on the anchor
3
p(d)
S = elastic section modulus of anchor bolt at concrete surface
32
Lb = z + (n)(d0) internal lever arm adjusted for spalling of the surface concrete
f VM
s Vu ACI 349-01 Eq. (B-2)

Variables
aM fu,min [N/mm2] Nu [kN] f Ns [kN] z [mm] n d0 [mm]
2.00 517.11 6.632 323.274 30 0.500 32
Calculations

M0s [kNm] (1 - fNN ) u


s Ms [kNm] Lb [mm]
1.950 0.979 1.910 46
Results
VM
s [kN] f steel f VM
s [kN] Vu [kN]
83.262 1.000 83.262 7.357

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 5
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

4.3 Pryout failure

Vcpg = kcp [(AA ) y


N
N0
1 y 2 y 3 Nb ] ACI 349-01 Eq. (B-21)
f Vcpg Vu ACI 349-01 Eq. (B-2)
AN see ACI 349-01R, Fig. RB.5.1
AN0 = 9 h2ef ACI 349-01 Eq. (B-5)

( )
1
y1 = 2 e'N 1.0 ACI 349-01 Eq. (B-7)
1+
3 hef
y2 = 0.7 + 0.3 (
cmin
1.5hef
1.0 ) ACI 349-01 Eq. (B-8)
1.5
Nb = k fc hef
'
ACI 349-01 Eq. (B-6a)

Variables
kcp hef [mm] e1,N [mm] e2,N [mm]
2 87 10 20

cmin [mm] y3 k f'c [psi]


50 1.250 24 5802

Calculations
AN [mm2] AN0 [mm2] y 1,1 y 1,2 y2 Nb [kN]
148000 67600 0.930 0.865 0.815 51.250
Results
Vcpg [kN] f concrete f Vcpg [kN] Vu [kN]
183.999 0.850 156.399 25.495

5 Combined tension and shear loads


bN bV z Utilisation bN,V [%] Status
0.065 0.163 5/3 6 OK
bNV = bzN + bzV <= 1

6 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
ACI349-01 does not specifically address anchor bending when a stand-off condition exists. PROFIS Anchor calculates a shear load
corresponding to anchor bending when stand-off exists and includes the results as a Design Strength!
Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI349-01 or the relevant
standard!
ACI 349-01, Appendix B, Part B.3.6.1 requires the governing design strength of an anchor or group of anchors to be limited by ductile steel
failure. If this is NOT the case, Part B.3.6.2 requires the attachment to be designed to undergo ductile yielding at a load level corresponding
to anchor forces not greater than 75% of the controlling design strength. In lieu of B.3.6.1 and B.3.6.2, the minimum design strength of the
anchors shall be multiplied by a reduction factor (f nonductile) per B.3.6.3
Pryout Strength can control the shear design if edge distances are large. When checking the Design Shear Strength per B.3.6.1, the Design
Concrete Breakout Strength and the Design Pryout Strength will be multiplied by a factor 0.85 and compared to 0.65 Ns
The design of Anchor Reinforcement is beyond the scope of PROFIS Anchor. Refer to ACI349-01, Part B.4.2.1 and the Commentary
RB.4.2.1
Please note that this PROFIS software is not produced or supplied under Hilti's 10CFR50, Appendix B compliant Nuclear Quality Program

Fastening does not meet the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 6
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

7 Installation data
Baseplate, steel: - Anchor type and size: Hex Head ASTM F 1554 GR. 55 1 1/4
Profile: Pipe; 168 x 168 x 7 mm Installation torque: -
Hole diameter in the fixture: df = 33 mm Hole diameter in the base material: - mm
Plate thickness (input): 20 mm Hole depth in the base material: 250 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 284 mm
Drilling method: -
Cleaning: No cleaning of the drilled hole is required

150 150

40
1 2

135
190
x
25

135

4 3
40

50 200 50

Coordinates Anchor mm
Anchor x y c-x c+x c-y c+y
1 -100 95 100 300 240 130
2 100 95 300 100 240 130
3 100 -95 300 100 50 320
4 -100 -95 100 300 50 320

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.2
Company: GSC Page: 7
Specifier: Project: DEWA R & D PV PANNEL
Address: Fastening Point: VERTICAL COLUMN
Phone I Fax: | Date: 3/16/2017
E-Mail:

8 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan