Vous êtes sur la page 1sur 6

Emergency Light Fitting for Fluorescent Lamps

Series ECOLUX 6608 Economy


E2
> For fluorescent lamps
2 x 18 W and 2 x 36 W
> Electronic ballast with integrated
emergency light electronics E2
> Battery is integrated in the lamp
enclosure
> For emergency light mode 1.5 h
> Intelligent charging technology E2
> Enclosures in glass fibre
reinforced polyester resin,
lamp cover in shock-resistant
polycarbonate E2
> Enclosure closed by means of
quick-action locks

E2
www.stahl.de

E2
Series ECOLUX 6608 Economy E2

12124E00

E2
The battery-operated emergency light fittings of the
Series ECOLUX 6608 Economy can be used as emergency lighting
according to EN 60598.
E2
ATEX / IECEx / GOST
Zone 0 1 2 20 21 22
For use in x x
E2

E2

E2

E2

E2

WebCode 6608A
E2
2014-12-01EK00IIIen Lighting E2/1
Emergency Light Fitting for Fluorescent Lamps
Series ECOLUX 6608 Economy

Selection Table
Version Lamps Lamp activation Operating time Order number Weight
test
kg
ECOLUX 6608 2 x 18 W 1 channel with 6608/322-8010-5247 3.860
Economy
Zone 2, 22 without 6608/322-8010-5248 3.860
2 x 36 W 1 channel with 6608/342-8010-5247 5.680
without 6608/342-8010-5248 5.680
Order Number Supplement
Through wiring without (standard) 6608/...-.0..-....
with 6 conductors (only for 36 W) 6608/34.-.6..-....
Cable entry Standard: M25 x 1.5 6608/...-..1.-....
1 Cable gland
2 Stopping plugs

Special M20 or M25 6608/...-..9.-....


of moulded material
or metal
to be specified with or-
der

Note The lights are delivered without fluorescent lamps and assembly parts.
These parts must be ordered separately!

Explosion Protection
Explosion protection
Global (IECEx)
Gas and dust IECEx PTB 09.0031X
Ex nA II T4
Ex tD A22 IP66 T65C
Europe (ATEX)
Gas and dust PTB 09 ATEX 2015 X
E II 3 G Ex nA II T4
E II 3 D Ex tD A22 IP66 T65C
Certificates and approvals
Certificates IECEx, ATEX, Russia (GOST R)

Technical Data
Electrical data
Rated voltage AC: 220 ... 240 V, 50 / 60 Hz
Disconnection of the light Optionally
when opening the lamp when opening the locking mechanism on one of the quick-action locks,
cover all poles of the voltage supply to the ballast are disconnected;
contacts of the switching element with positive break, they are switched
on again as soon as the lamp cover and the quick-action lock are
closed.
in case of a lamp fault in case of a lamp fault, the electronic ballast disconnects the defective
lamp from the power supply.
Luminous Characteristics
Lamps 2 x 18 W 2 x 36 W
Lamp version 2-lamp 2-lamp
without auxiliary reflector with auxiliary reflector
Class according to LitG B21 B31
Measures for light Standard
guidance Broad reflective, internal reflector of light fitting painted white.
Colour: Signal white RAL 9003; lateral glare is limited by the lamp diffuser cover.
Special
Auxiliary reflector (easily mountable), narrow-angle / wide-angle shining, aluminium anodised and
polished.

E2/2 Lighting 2014-12-01EK00IIIen


Emergency Light Fitting for Fluorescent Lamps
Series ECOLUX 6608 Economy
E2
Technical Data
Ambient conditions
Standard operation - 20 ... + 40 C
Battery operated functional at temperatures between - 5 ... + 40 C
Mechanical data
Degree of protection IP66 (IP64 with breather 8162)
E2
Protection class I(with internal PE connection)
Material
Enclosure Polyester resin, glass fibre reinforced, colour white, similar to RAL 9010
Lamp cover
Seal
Polycarbonate, shock-resistant, as an option an aromatic-resistant paint can be used
Polyurethane foam gasket in the lamp cover
E2
Quick-acting locks Polyamide, glass fibre reinforced
Assembly parts Polyester resin, glass fibre reinforced, white, similar to RAL 9010
Cover options Quick-acting locks to be opened by means of a screwdriver;
lamp cover is equipped with a hinge
Assembly / Installation E2
Cable glands Connection side:
1 cable gland M25 x 1.5 and 1 stopping plug M25 x 1.5
Opposite side:
1 stopping plug M25 x 1.5
(cable glands enclosed)
Entry parts in moulded plastic (8161/8290): M20 E2
Metal glands: M20, M25,
Metal cable gland earthing via metal adapter plates
Connection option Terminals L1, L2, L3, N, PE, L' (switched phase)
2.5 mm fine / single wire
L1 = charging phase, must not be switched
Through wiring Lights available with internal through wiring, 6 wires; Cross-section 2.5 mm for max. 16 A E2
only possible for 36 W
Battery set
Version NiCd battery
Operating voltage 6V
Capacity 4 Ah E2
Replacing the battery set Open the light, the battery can be replaced by means of plugs in the enclosure
Emergency light electronics
Design The emergency light electronics is installed in an enclosure together with the electronic ballast
Operating modes Continuous circuit
Interference suppression according to DIN EN 55015 E2
Functional test The functional test lasts one minute and is carried out automatically once a week.
Note: The first functional test is carried out 1 hour after putting into operation, that means after
having connected the operating voltage to the terminals L1 and N.
Light duration test of the The continuous function test for the emergency lighting is carried out every six months for a time
emergency lighting period of 1 hour. During the test, the battery capacity is checked.
Note: The first continuous function test is carried out 24 hours after putting into operation, that
means after having connected the operating voltage to the terminals L1 and N.
E2
Function indicators LED display
After putting into operation and after each connection to the power supply voltage, the LED lights
up for 10 seconds (function control of the LED). The display indicates for 10 seconds whether the
continuous function test is activated (LED flashes) or deactivated (LED off). Afterwards the display
switches to the normal display mode and the following states are shown. E2
LED green - Light is OK
- Charging current flows
LED flashes - Light is OK
- Functional test is active
LED off - Mains failure
E2
- Lamp or battery fault
Battery charge Intelligent battery management
Emergency light mode In the emergency light mode, only one lamp is used, see table
Emergency light service
time
1.5 h for a battery capacity 4 Ah E2
Switchover voltage from mains to battery operation for U < 0.74 x UN
from battery to mains operation for U > 0.80 x UN
Lighting power in case of 18 W: 64 %
emergency light mode 36 W: 32 %
E2

E2
2014-12-01EK00IIIen Lighting E2/3
Emergency Light Fitting for Fluorescent Lamps
Series ECOLUX 6608 Economy

Accessories and Spare Parts


Designation Illustration Description Art. no. Weight
kg
Fluorescent lamp Two-pin cap d 26 mm
Light colour: universal white
04936E00
18 W 1350 Im 108952 0.100

36 W 3350 Im 108951 0.200

58 W 5200 Im 108950 0.220

Lamp cover for lamp 18 / 20 W 124635 0.500


for lamp 36 / 40 W 124646 1.300
05329E00 for lamp 58 / 65 W 124657 1.000
Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025

10809E00

Lamp holder Lamp holder for two-pin cap lamps G 13 107275 0.008

05888E00

Mounting rail for a variable mounting distance of 1 pair 124894 0.210

05895E00

Mounting rail with a Mounting bracket mounted of 1 pair 124901 0.300


bracket on the mounting rail
for a variable mounting distance
05896E00

Ring bolt M 8 M8, direct mounting in insert nuts, 1 pair 115736 0.120

05378E00

Fixation for stanchion to mount the lamps as side-entry lamps using a tube with
mounting a length of 1300 mm, d 42 mm
(for pipe clamp R 11/2) 109281 6.000
05460E00

Top rail for ceiling suspension of the lamp, 1 pair 124908 0.230

05897E00

Pipe clamp with mounting rail for a variable mounting distance;


Material: stainless steel
R 11/4 (d 42 mm) 124913 1.140
09402E00
R 11/2 (d 48 mm) 124891 1.160
R 2 (d 60 mm) 124898 1.300
Mounting set for grid for grid cable racks, with a cable diameter of 6 mm; 124905 1.560
racks with mounting rail for a variable mounting distance;
Material: stainless steel

04361E00

Wall and ceiling mounted on a mounting rail for a variable mounting dis-
mounting bracket tance;
Material: stainless steel
Lamp can be swiveled in steps of 15
1 pair 124910 1.150

05898E00

E2/4 Lighting 2014-12-01EK00IIIen


Emergency Light Fitting for Fluorescent Lamps
Series ECOLUX 6608 Economy
E2
Accessories and Spare Parts
Designation Illustration Description Art. no. Weight
kg
Adapter plates for earth continuity when using metal glands; E2
1 x M20 x 1.5 1 piece 115815 0.070

1 x M25 x 1.5 1 piece 115818 0.070


05755E00

1 x NPSM 1/2 1 piece 115821 0.070 E2


1 x NPT 3/4 1 piece 115824 0.070

2 x M20 x 1.5 1 piece 115826 0.060


E2
2 x M25 x 1.5 1 piece 115828 0.060

2 x NPSM 1/2 1 piece 115829 0.060

Battery set NiCd battery for 6608/3 4 Ah / 6 V 1 pc 211520 1.100


E2
13622E00

Reflectors for later installation, broad deep beam


for lights with two lamps 18 W 117098 0.265 E2
05324E00 for lights with two lamps 36 W 117115 0.234
Cable gland of moulded material, series 8161 0.000
8161/5-M20-13 1 piece 138518 0.012
05864E00 E2
8161/5-M20-13 50 pieces 138454 0.600

8161/5-M25-17 1 piece 138520 0.020

8161/5-M25-17 50 pieces 138456 1.000 E2


Stopping plugs of moulded material, series 8290
8290/3-M20 1 piece 143522 0.005

E2
04840E00

8290/3-M20 100 pieces 143543 0.500

8290/3-M25 1 pieces 143524 0.007

8290/3-M25 100 pieces 143544 0.700


E2
Breathing gland for installation in lights;
in moulded material; without counter nut
Thread: M25 x 1.5 1 pc 138573 0.010
05703E00

Thread: M25 x 1.5 20 pcs 138576 0.200


E2

E2

E2

E2
2014-12-01EK00IIIen Lighting E2/5
Emergency Light Fitting for Fluorescent Lamps
Series ECOLUX 6608 Economy

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations


Di- Light
men- 18 W 36 W
sions
L1 700 1310
L2 1) 400 800
L3 2) 340 ... 460 680 ... 920
1) fixed mounting distance
2) variable mounting distance

04824E00

Emergency light fitting ECOLUX 6608 Economy, 18 W, 36 W

04717E00 04822E00

Pipe clamp Mounting set for grid racks

04716E00 04833E00

Wall and ceiling mounting bracket Top rail

04823E00 04715E00 04834E00

Fixation for stanchion mounting Ring bolt Mounting rail with a bracket
Mounting accessories

We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.

E2/6 Lighting 2014-12-01EK00IIIen