REFERENCE:

ARCH. DRG
1)SDG(E)/BSF/ENGG/2016-4/1/ARCH/KSM
2)SDG(E)/BSF/ENGG/2016-4/1/ARCH/KSM
3)SDG(E)/BSF/ENGG/2016-4/3/ARCH/KSM

A B C D E F G
GENERAL NOTES:-

( Ld+2db)
1. DISCREPANCY AMONGST THIS STRUCTURAL DRG. THE CORRES-
PONDING ARCHITECTURAL DRAWINGS AND THE AGREEMENT
2200 3160 3160 3160 3160 2000 ITEM IF ANY, SHALL BE GOT RECONCILED BEFORE EXECUTION.

hc/4
C01 C02 C03 C04 C05 C06 C07 2. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
3. NO DIMENSION ARE TO BE SCALED OUT FROM DRAWING, ONLY
4 FIGURE WRITTEN DIAMENSIONS SHALL BE FOLLOWED.

50

100
100
100
100
100
100
4. DIMENSION ARE TO BE VERIFIED AT SITE BEFORE EXECUTION
50 50 OF WORK.
5. VARIOUS APPLICABLE PROVISIONS OF I.S. :456-2000 SHALL BE
FOLLOWED FOR R.C.C WORK.
6. CEMENT SHALL BE 1:1.5:3 FOR ALL STRUCTURAL
WORK AS PER CPWD SPECIFICATIONS AND RELEVANT I.S. CODE.

3050
7. ALL REINFORCEMENT SHALL BE OF HIGH YIELD STRENGTH THERMO
MECHANICALLY TREATED BARS.(Fe-500D) CONFORMING TO IS-1786.
8. REINFORCEMENT SHALL HAVE NOMINAL,COVER EXCLUDING
PLASTER OR OTHER DECORATIVE FINISH AS FOLLOWS :-
C08 C09 C10 C11 a) FOR FOUNDATION :- 50MM (BOTTOM & TOP)
b) FOR COLUMN :- 40MM

hc
3 c) FOR BEAM :- 30MM

50

100
d) FOR SLAB :- 20 MM

100
100
50 50 NOMINAL COVER TO REINFORCEMENT SHALL BE THICKNESS OF
CONCRETE COVER TO ALL STEEL REINF INCLUDING SECONDARY
REINF ALSO.
9. THE TOP OF ALL GRADE BEAMS SHALL BE AT FINISHED
GROUND LEVEL EXCEPT FOR EXTERNAL GRADE BEAMS
AROUND TOILET/W.C LOCATIONS WHICH MAY BE PLACED

3250
AS PER SITE REQUIREMENTS..
10. IF ANY ACTUAL SUB SOIL CONDITION DURING EXCAVATION DIFFER
FLOOR TO FLOOR HEIGHT=3000

FROM AS REPORTED OR LOOSE STRATA FOUND THE SAME MAY BE


REPORTED TO THIS OFFICE BEFORE EXECUTION.
11. FOUNDATION DESIGN HAS BEEN BASED ON THE NET BEARING
C12 C13 C14 C15 C16 C17 CAPACITY OF SOIL 197.22 KN/SQ.M AT 1.5 METRE BELOW EXISTING G.L
AS PER SOIL REPORT SUBMITTED BY EE/MGCD, C.P.W.D, SHILLONG .
2
hc/4

12. ORIENTATION OF COLUMN SHOULD BE AS PER THE LAYOUT PLAN

100
100
100
100
100
100
50 50 AND CENTRE LINE COLUMN SHOULD BE FIXED AS DIMENSION
GIVEN IN ARCHITECTURAL DRAWING.
13. DEVELOPMENT LENGTH OF REINFORCEMENT BARS SHALL BE
IN TENSION-- 49X DIA. OF BAR.
IN COMPRESION -- 39X DIA. OF BAR.
14. LAP SHALL BE STAGGERED AND AVOIDED AT THE POINTS OF
MAXIMUM BENDING.

3600
15. NOT MORE THAN 50% OF BARS SHALL BE SPLICED AT ONE SECTION
IN COLUMNS AND BEAMS.
16. LAP SPLICE SHALL BE IN CENTRAL HALF OF COLUMN LENGTH AND
SHALL PROPORTIONED AS TENSION SPLICE.
17. TIES SPACING IN ENTIRE SPLICE LENGTH IN COLUMN SHALL NOT
EXCEED 150 C/C.
C18 C19 18. STIRRUPS SPACING IN SPLICE LENGTH SHOULD NOT EXCEED 150MM
1 CENTRE TO CENTRE.

100
100
19. LAP SHALL NOT BE PROVIDED IN A BEAM WITHIN A DISTANCE OF
50
2d FROM JOINT FACE.
20. BOTTOM MOST LAYER OF REINFORCEMENT IN FOOTING SHALL BE
PLACED ALONG THE SIDE WHICH ONE IS HAVING LARGER
OUTSTAND BEYOND THE COLUMN/ PEDESTAL FACE.
21. IN COLUMN REINFORCEMENT, LARGER DIAMETER REINFORCEMENT
COLUMN LAYOUT BAR SHALL BE PLACED AT CORNER WHENEVER TWO DIFFERENT
DIA OF BAR ARE USED.
Grade of Steel: Fe-500D (As 22. ALL BRICK WALLS SHALL BE RAISED AFTER THE SHUTTERING OF
per IS:1786-2008) BEAM AND SLAB BELOW ARE REMOVED.

Grade of Concrete: 1:1.5:3 O/o THE INSPECTOR GENERAL


as per CPWD specifications
FTR HQ BSF MEGHALAYA, SHILLONG (ENGG. BRANCH)
CHECKED BY :- RE-CHECKED BY :- APPROVED BY :-

TYP. SECTION SIZE STIRRUPS/TIES TYP. SECTION SIZE STIRRUPS/TIES PROJECT :-


PROPOSED KSM AND SO's ROOM BUILDING
80 300 FOR ICP DAWKI
300 300 X 300 300 X 400
80 JOB :- STRUCTURAL DRAWING.
80 a a 80 a
a
REINF. BAR REINF. BAR
TITLE :- COLUMN LAYOUT & DETAILS

300
SHEET DRAFTED BY: DESIGNED BY:
DRG. NO. :-
400
4 -16 4 -16 146-01-D001 NO.- D. BORO S.A.BARBHUIYA
b
2 -16 CAD. NO. :- 146-01-D001 DATED- 07-04-2017 P - A3 REV.-01
03
b
8 TIE M/S. MJ CONSULTANCY
8 TIE Regd. Office Address : R.K.Pally, Itkhola, Silchar, Cachar, Assam Pin-788002,
M :+919435993044/943537073.
Branch Office Address: (i) F3, Apurva Apartment, Maniknagar,Guwahati-05,Assam.
(ii) Room No.-24, 1st Floor, Idgha Complex, Itkhola Road, Itkhola,
Silchar, Cachar, Assam.
C07, C11 C01-C06, C08, C09, C10, C12-C19 Email ID: mjgroup2010@hotmail.com
Ph. & Fax: +91 361-2201786, M: 9435993044