The Timber Resin Splice is a Patented device for replace ends or mid span replacing the ends or mid-sections of timber. wood replaces wood easy to fix to It should only be attached to sound timbers. These natural appearance timbers must be treated to our Specification to Fire Tested resin connection validate our Lifetime Guarantee. match species e.g. oak, elm no bolts, nails or plates For indoor use, the moisture content of the parent timber must not exceed 22% in the connection zone.
HISTORY STRUCTURAL CALCULATIONS
The Timber-Resin Splice (TRS) was Based on the Straight Line Theory of Patented in 1997 and has been Elasticity (as originally used for concrete) manufactured exclusively by Property and available at three levels: Repair Systems. Over 6,000 beam ends as part of an Order for TRS Kits (free) and mid-span repair Kits have been as a separate Calculation by us (charge) supplied, to all parts of the UK and Ireland. from our Independent Structural Engineer, Indemnified (charge)
TECHNICAL DATA LIMITATIONS
TRS repair units need to broadly match Resins the moisture content of the existing - Compressive strength 81N/mm2 timber in the environment in which they - Tensile strength 22 N/mm2 will be installed. Most units are installed - Flexural strength 42 N/mm2 indoors, in centrally heated - Specific gravity 1.53 environments. To match indoor - Static Modulus Et 17,235 KN/mm2 situations Kiln Dried (KD) timber is used - Youngs Modulus 8300 N/mm2 and normally this level of drying will - Bond Strength, timber & steel 6-12 N/mm2 tolerate the ambient temperature and humidity of the modern building. Timber However, occasionally during Site - Visual Strength Grading to BS EN518 storage or after installation, splitting or - Kiln Dried cracking may occur along the grain of - C16 and C24 (SC3/SC4) the timbers (shakes) as they adjust to - Oak, Elm, Pitch Pine, Douglas Fir their new environment. This is perfectly normal and no special action is Bars necessary. - Steel Allthreaded Bar, High Tensile, 8.8 For further technical guidance contact us - BS.EN.ISO.898-1:2009 on: 01626 331351 or at - Bright Zinc Plated TO BS.7371-1:2009 dcmoore@timber.org.uk