Académique Documents
Professionnel Documents
Culture Documents
TRAINING
Version 4
Pasolink V4 3
FEATURES
EASY AND QUICK INSTALLATION
Very compact and light
Only one coaxial cable interconnection
Different mounting methods for IDU, ODU and Antenna
Easy antenna pointing adjustments (RX level monitor point in ODU)
TX POWER CONTROL
Automatic Transmit Power Control (ATPC) or Manual Transmit Power Control (MTPC)
Variable : 0 to 30 dB, in 1 dB steps (13-38 GHz) (For V4 ODU 7-38 GHz)
: 0 to 10 dB, in 1 dB steps (7-8GHz) (V3 ODU)
SYSTEM FLEXIBILITY
(1 + 0 ) unprotected or ( 1+ 1) protected
Hot Standby/ Space Diversity / Twin Path systems are available with Hitless switch
Common IDU for different RF frequencies (7/8/13/15/18/23/26//38 GHz)
Software variable transmission bit rates (Bit Rate free type)
Common ODU for different bit rates (16x2, 8x2, 4x2, 2x2 Mbit/s /10Base-T /100Base-TX
Wide input line voltage (20 to 60) V DC
Pasolink V4 4
FEATURES
EASY MAINTENANCE FACILITIES
Full front panel access for all cabling and user interfaces
Near End and Far End Base-band Loop back facilities
Remote monitoring of ODU operating condition from IDU
OW calling facility between IDU - ODU, IDU IDU and ODU-ODU
Pre-settable BER alarm point: 10-3, 10-4 10-5 or 10-6 (alarm and AIS injection)
Local monitor and maintenance using Local Craft Terminal (LCT)
Continuous RSL monitoring using Local Craft Terminal (LCT)
MULTIPLE SERVICE CHANNELS
Engineering Order Wire (OW)
Digital Service Channels - Two standard and two optional
Analog Service Channels- Two optional
NMS Service Channel for Pasolink Monitoring
ELECTRO MAGNETIC COMPATIBILITY (EMC)
1 V3 V3 V3 V3
2 V4 V3 V3 V4
3 V3 V4 V4 V3
4 V4 V3 V3 V3
5 V3 V4 V3 V3
6 V4 V4 V3 V3
7 V4 V4 V4 V3
8 V4 V4 V3 V4
9 V4 V4 V4 V4
Full Compatibility between V3, V4, ODU and IDU
Pasolink V4 10
System Composition
1- Indoor unit (IDU) ( Modulation-Demodulation unit)
2- Outdoor unit (ODU) ( Transmit Receive unit)
3- IF cable and connectors ( To connect the IDU & ODU)
4- Antenna on the required microwave band
5- Hybrid ( coupler ) in case of 1+1 one antenna configuration
6- RF cable ( If the ODU is not direct mounted to the antenna)
ODU (low band)
ODU (High band) TX RX
TX/RX
TX/RX
RX TX
RF RF
Antenna
Antenna IF
IF
Pasolink V4 11
PASOLINK (1+0) SYSTEMS
2MB x 4, Fixed Bit Rate system with 2 x 10/100Base T (X) LAN Interface
2MB x 2/4/8/16 Bit Rate Free system with 2 x 10/100Base T (X) LAN Interface
Pasolink V4 12
PASOLINK (1+1) SYSTEMS
2MB x 4, Fixed Bit Rate system 2MB x 4, Fixed Bit Rate system with 2 x 10/100Base T (X)
LAN Interface
2MB x 2/4/8/16 Bit Rate Free system 2MB x 2/4/8/16 Bit Rate Free system with 2 x
10/100Base T (X) LAN Interface
Pasolink V4 13
INDOOR UNIT
Pasolink V4 14
E1 INTERFACE
When 120 ohms or 75 ohms
is used other interface should
be terminated using the dip
switches on the Switch Board-
2 inside the top cover of the
IDU.
Pasolink V4 16
V4 OUT DOOR UNIT (7-38 GHz)
Pasolink V4 17
V /H POLARIZATION (1+1)
Pasolink V4 18
System Configuration
A- Non protected system (I+0)
TX RX
IDU
ODU IDU
( 1+0 ) RX TX ODU
( 1+0 )
Pasolink V4 19
System Configuration
C- Protected system (1+1) hot standby Space diversity
Double antenna configuration
TX/RX RX TX TX/RX
ODU-1 ODU-1
Modem-1 RX
TX Modem-1
Switch
Rx only Switch
Modem-2 Rx only
Modem-2
ODU-2
RX ODU-2
RX
Pasolink V4 20
PERFORMANCE
ITEM 7GHz 8GHz 13 15 GHz 18 23 26 38
GHz GHz GHz GHz GHz
Output Power (dBm) +27 +27 +25 +23 +23 +23 +20 +15
Measured at ODU Output
Port (1.5dBm)
BR loss TX and RX 3.5 dB/3.5 dB
Threshold level in dBm, ODU With Hybrid Combiner/Divider (One Antenna System)
Port
BER=10-3 4MB -90 -90 -90 -90 -89.0 -88.0 -87.5 -87.0
8MB -87 -87 -87 -87 -86.0 -85.0 -84.5 -84.0
17MB -84 -84 -84 -84 -83.0 -82.0 -81.5 -81.0
34MB -81 -81 -81 -81 -80.0 -79.0 -78.5 -78.0
BER=10-6 4MB -86.5 -86.5 -86.5 -86.5 -85.5 -84.5 -84.0 -83.5
8MB -83.5 -83.5 -83.5 -83.5 -82.5 -81.5 -81.0 -80.5
17MB -80.5 -80.5 -80.5 -80.5 -79.5 -78.5 -78.0 -77.5
34MB -77.5 -77.5 -77.5 -77.5 -76.5 -75.5 -75.0 -74.5
Pasolink V4 21
PERFORMANCE
ITEM 7GHz 8GHz 13 15 GHz 18 23 26 38
GHz GHz GHz GHz GHz
System Gain (dB): 113.5 113.5 111.5 109.5 108.5 107.5 104.0 98.5
BER=10-3 4MB
110.5 110.5 108.5 106.5 105.5 104.5 101.0 95.5
8MB
107.5 107.5 105.5 103.5 102.5 101.5 98.0 92.5
17MB
104.5 104.5 102.5 100.5 99.5 98.5 95.0 89.5
34MB
BER=10-6 110.0 110.0 108.0 106.0 105.0 104.0 100.5 95.0
4MB
107.0 107.0 105.0 103.0 102.0 101.0 97.5 92.0
8MB
104.0 104.0 102.0 100.0 99.0 98.0 94.5 89.0
17MB
101.0 101.0 99.0 97.0 96.0 95.0 91.5 86.0
34MB
Pasolink V4 22
PERFORMANCE
ITEM 7GHz 8GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38 GHz
Output Power (dBm) Measured at +27 +27 +25 +23 +23 +23 +20 +15
ODU Output Port (1.5dBm)
BR loss TX and RX N/A
Threshold level in dBm, ODU Port Without Hybrid Combiner/Divider (Two Antenna System) or (1+0) Configuration
BER=10-3 4MB -93.5 -93.5 -93.5 -93.5 -92.5 -91.5 -91.0 -90.5
BER=10-6 4MB -90.0 -90.0 -90.0 -90.0 -89.0 -88.0 -87.5 -87.0
System Gain (dB): BER=10-3 4MB 120.5 120.5 118.5 116.5 115.5 114.5 111.0 105.5
BER=10-6 4MB 117.0 117.0 115.0 113.0 112.0 111.0 107.5 102.0
Pasolink V4 23
PERFORMANCE
IN DOOR UNIT
ITEM SPECIFICATION
Modulation Type 4PSK ( with differential coding)
Base Band Interface
16 x 2 Mbit/s 2.048 Mbit/s 50 ppm
8 x 2 Mbit/s 2.048 Mbit/s 50 ppm
4 x 2 Mbit/s 2.048 Mbit/s 50 ppm
2 x 2 Mbit/s 2.048 Mbit/s 50 ppm
IF Output -5 dBm Nominal
IF INPUT -15 to 0dBm (varies with cable length) (8D-FB length 300m)
Service Channels See option cards slide
Loop Back Far End and Near End Base-band Loopback
Spectrum Shaping Root Roll-Off ( = 0.5)
Residual BER Less than 10-12 at RSL = -30 dBm
BER Alarm Output Adjustable 10-3/ 10-4/ 10-5/ 10-6 (AIS injection point)
ODU Monitor Items Received Signal level (AGC V)
Output Power Level (TX Power)
LED Display Operating PWR (green) / IDU ALM (red)/ ODU ALM (red)/ Maint (yellow)
Temperature Range -0OC to + 50OC
Power Requirement 20 to 60 V DC
Pasolink V4 24
V4 ODU PERFORMANCE
ITEM 7GHz 8GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38 GHz
Frequency Range [GHz] 7.125 - 7.725 7.900- 8.500 12.75- 14.5-15.35 17.7-19.7 21.2-23.6 24.5- 37.0-39.5
13.25 26.5
Frequency Plan ITU-R F385-6 F386-6 F.497-6 F.636-3 F.595-7 F.637-3 F748-4 F.749-2
Annex 4
Channel Separation 3.5 MHz (4MB)/ 7MHz (8MB)/ 14MHz (17MB)/ 28MHz (34MB)
For 18GHz : 13.75 MHz (17MB) and 27.5 MHz (34MB)
RF TX/RX Spacing 154 126 266 315 340 1008 1008 1260
[MHz] 161 266 420 1008 1200
245 119 490 1010 1232
728 1560
Frequency Agility (Mhz) 63 42 56 56-100 252 280 280 280
without changing filters
Receiver Noise Figure (dB) 4.5 4.5 4.5 4.5 5.5 6.5 7.0 7.5
Max. input level -15 dBm (No error)
IF Signal (IDU-ODU) TX: 850 MHz RX: 70 MHz
Frequency Stability +/- 5 ppm
Signal Level : Input to ODU: -52 to -3 dBm (depend on the cable length) : Output from ODU : 0 dBm nominal
Control/Monitor signal 10 MHz ASK, (at IF IN/OUT)
Order Wire ODU input: 450 KHz, AM ODU output: 468 KHz , AM
Power Control 0 to 30 dB in 1 dB steps variable
Temperature Range -33OC to + 50OC
EMC Conforms to ETS300 385 Class B
Power Supply -43V DC
Pasolink V4 25
OPTION CARDS
SC LAN INTERFACE: 10 BASE-T (TRANSMISSION RATE 64Kbps)
WS INTERFACE (G703): 2.048 Mbps G.703
WS INTERFACE (LAN): 10 BASE-T (TRANSMISSION Rate 2 Mbps)
ALM INTERFACE : 2 CH EXTERNAL DRY CONTACT EXTENSION
Note:
When SC LAN option card is mounted, it is not possible to mount ASC, DSC, ALM and WS interface cards.
When 64k option card is used select either G.703 or V11 card
Pasolink V4 26
Option Cards
ASC
DSC 3 SC 2
DSC
DSC 4 SC 3
ALM
N )
LA raffic
T rd
(M
ain Ca
PM Note 1 : If SC LAN card is mounted on a
SC LAN 2MB x 16 System, either 64K or 2MB can
be selected.
S
W
Note 2 : Either WS or SC LAN Card can be mounted.
64
K Note 3 : If SC LAN Card is mounted, ASC /
DSC / ALM / WS cards can not be mounted.
ASC/DSC/ALM
Pasolink V4 27
OPTIONS
Pasolink V4 28
BLOCK DIAGRAM
Pasolink V4 29
REDUNDANCY BLOCK DIAGRAM
Pasolink V4 30
INDICATORS/SWITCHES/CONTROLS
MAINT LED
PWR SW Maintenance Mode ON
Turns input DC power ON/OFF Loopback control ON
CW mode ON
Power Mute ON
RESET SW BER AIS Inhibit
Initialize CPU
ODU LED
Transmit RF power decrease by 3 dB from nominal
Receiver level goes below squelch level
ODU local oscillator APC loop unlock
CALL SW IF signal from the IDU is low
EOW calling signal,opposite station buzzer rings
IDU LED
RX OPR 1 LED Input data stream of CH() from DTE lost
RX side of IDU1 and ODU 1 is online AIS signal from CH() received from DTE
RX OPR 2 LED DPU TX/RX sysnchronization lost
RX side of IDU2 and ODU 2 is online AIS signal sent out on CH ()
Bipolar output pulse of CHC() is lost at 2M INTFC
Traffic channel usage of CH[ ] error in setting
HBER is worse than 1x10-3 at DPU section
BER is worse than the preset threshold value
Carrier synchronization lost at the DEM section
MOD VCO sysnchronization lost
Output data stream/Master clock lost at TX DPU
When the IF cable between the IDU and ODU is disconnected Frame synchronization is lost at the DPU section
IDU and ODU ALM LEDs start flashing WS channel usage error
Pasolink V4 31
PASOLINK CONNECTORS FOR 2MB x 16 SYSTEM
Pasolink V4 32
IDU (1+0) CONNECTORS
TRAFFIC IN/OUT ( CH 9 TO CH 16 ) ALM /AUX ALM
CH16 Input (+) 1 20 CH16 output (+) ALM RL1 (COM) 1 20 ALM RL3 (COM)
CH16 Input (-) 2 21 CH16 output (-) ALM RL1 (NO) 2 21 ALM RL3 (NO)
CH15 Input (+) 3 22 CH15 output (+) ALM RL1 (NC) 3 22 ALM RL3 (NC) WS Option only on 16x2 Mbps
CH15 Input (-) 4 23 CH15 output (-) ALM RL2 (COM) 4 23 ALM RL4 (COM) WS INTFC
Ground 5 24 Ground ALM RL2 (NO) 5 24 ALM RL4 (NO) 120 Ohms 75 Ohms
CH14 Input (+) 6 25 CH14 output (+) ALM RL2 (NC) 6 25 ALM RL4 (NC) 1 WS OUT+ WS OUT
CH14 Input (-) 7 26 CH14 output (-) HK1 ALM Input 7 26 HK Control Out 1 2 WS OUT-
CH13 Input (+) 8 27 CH13 output (+) HK1 ALM Input 8 27 HK Control Out 1 4 WS IN + WS IN
CH13 Input (-) 9 28 CH13 output (-) HK2 ALM Input 9 28 HK Control Out2 5 WS IN -
Ground 10 29 CH12 output (+) HK2 ALM Input 10 29 HK Control Out2 8 FG G
10/100Base-T Port 1 & 2
Frame CH12 Input (+) 11 30 CH12 output (-)
MDI-X MDI
HK3 ALM Input 11 30 HK Control Out3
PNMS LAN
CH12 Input (-) 12 31 CH11 output (+) HK3 ALM Input 12 31 HK Control Out3 SC LAN
Ground CH11 Input (+) 13 32 CH11 output (-) 1 RD+ TD+ HK4 ALM INput 13 32 HK Control Out 4 1 LAN DSC TX+
1 LAN PNMS TX+
2 RD- TD- 2 LAN PNMS TX-
CH11 Input (-) 14 33 Ground HK4 ALM Input 14 33 HK Control Out4 2 LAN DSC TX-
3 TD+ RD+ 3 LANPNMS RX+
Ground 15 34 CH10 output (+) HK5 ALM Input 15 34 Not Used 3 LANDSC RX+
4 TD- RD- 6 LAN PNMS RX-
CH10 Input (+) 16 35 CH10 output (-) HK5 ALM Input 16 35 Not Used 6 LAN DSC RX-
IF IN/OUT CH10 Input (-) 17 36 CH9 output (+) HK6 ALM Input 17 36 Buzzer signal In
CH9 Input (+) 18 37 CH9 output (-) HK6 ALM Input 18 37 Buzzer signal Out
CH9 Input (-) 19 Ground 19 OW HEADSET JACK
TRAFFIC IN/OUT ( CH 1 TO CH 8 )
CH8 Input (+) 1 20 CH8 output (+) LINE IN
NMS RA PORT LA PORT 1 0V or (+48V)
CH8 Input (-) 2 21 CH8 output (-) OW/DSC/ASC
Anti Static CH7 Input (+) 3 22 CH7 output (+) ASC1(VF) or Alm1 Input (+) 1 14 ASC1(VF) or Alm1 output (+)
(PAMS) TXD 1 RA TXD 1 TXD 2 -48V or (0V)
EMS TXD/TXD+ 2 RA GND 2 GROUND
strap connector CH7 Input (-) 4 23 CH7 output (-) ASC1(VF) or Alm1 Input (-) 2 15 ASC1(VF) or Alm1 output (-) EMS RXD/TXD- 3 RA RXD 3 RXD
3
Ground 5 24 Ground 4
ASC2(VF) or Alm2 Input (+) 3 16 ASC2(VF) or Alm2 output (+) EMS TXDR 4 RA RTS 4 RTS
CH6 Input (+) 6 25 CH6 output (+) ASC2(VF) or Alm2 Input (-) 4 17 ASC2(VF) or Alm2 output (-) EMS TRS/RXD+ 5 RA CTS 5 CTS
CH6 Input (-) 7 26 CH6 output (-) EOW input (VF) (+) 5 18 EOW output (VF) (+) EMS CTS/RXD- 6 6
CH5 Input (+) 8 27 CH5 output (+) EOW input (VF) (-) 6 19 EOW output (VF) (-) GROUND 7 7
CH5Input (-) 9 28 CH5 output (-) 64 KHz Clock input (+) 7 20 64 KHz Clock output (+) 8 8 GROUND
Ground 10 29 CH4 output (+) 64 KHz Clock input (-) 8 21 64 KHz Clock output (-) PAMS RXD 9 9
CH4 Input (+) 11 30 CH4 output (-) DSC1 input (+) 9 22 DSC1 output (+) NMS TXD/TXD+ 10 10
CH4 Input (-) 12 31 CH3 output (+) DSC1 input (-) 10 23 DSC1 output (-) NMS RXD/TXD- 11 11 LOCAL CTS
CH3 Input (+) 13 32 CH3 output (-) DSC2 input (+) 11 24 DSC2 output (+) NMS TXDR 12 12 LOCAL RTS
CH3 Input (-) 14 33 Ground DSC2 input (-) 12 25 DSC2 output (-) NMS RTS/RXD+ 13 13 LOCAL RXD
Ground 15 34 CH2 output (+) Ground 13 NMS CTS/RXD- 14 14 GROUND
CH2 Input (+) 16 35 CH2 output (-)
15 15 LOCAL TXD
CH2 Input (-) 17 36 CH1 output (+)
CH1 Input (+) 18 37 CH1 output (-) When PM card is not mounted on the equipment NMS port is used
CH1 Input (-) 19
as RA port. NMS port or NMS LAN depends on the PM card Type
Pasolink V4 33
IDU (1+1) CONNECTORS
WS Option only on 16x2 Mbps OW/DSC/ASC
ASC1(VF) or Alm1 Input (+) 1 14 ASC1(VF) or Alm1 output (+)
TRAFFIC IN/OUT ( CH 9 TO CH 16 ) WS INTFC
ASC1(VF) or Alm1 Input (-) 2 15 ASC1(VF) or Alm1 output (-)
CH16 Input (+) 1 20 CH16 output (+) 120 Ohms 75 Ohms
ASC2(VF) or Alm2 Input (+) 3 16 ASC2(VF) or Alm2 output (+)
CH16 Input (-) 2 21 CH16 output (-) 1 WS OUT+ WS OUT
2 WS OUT-
ASC2(VF) or Alm2 Input (-) 4 17 ASC2(VF) or Alm2 output (-)
CH15 Input (+) 3 22 CH15 output (+)
EOW input (VF) (+) 5 18 EOW output (VF) (+)
CH15 Input (-) 4 23 CH15 output (-) Anti Static 4 WS IN + WS IN
EOW input (VF) (-) 6 19 EOW output (VF) (-)
Ground 5 24 Ground 5 WS IN - PNMS LAN
CH14 Input (+) 6 25 CH14 output (+)
strap connector 8 FG G 1 LAN PNMS TX+
64 KHz Clock input (+) 7 20 64 KHz Clock output (+)
64 KHz Clock input (-) 8 21 64 KHz Clock output (-)
CH14 Input (-) 7 26 CH14 output (-) 10/100Base-T Port 1 & 2 2 LAN PNMS TX-
SC LAN DSC1 input (+) 9 22 DSC1 output (+)
CH13 Input (+) 8 27 CH13 output (+) MDI-X MDI 3 LANPNMS RX+
1 LAN DSC TX+ DSC1 input (-) 10 23 DSC1 output (-)
CH13 Input (-) 9 28 CH13 output (-) 1 RD+ TD+ 6 LAN PNMS RX-
2 LAN DSC TX- DSC2 input (+) 11 24 DSC2 output (+)
Ground 10 29 CH12 output (+) 2 RD- TD-
3 LANDSC RX+ DSC2 input (-) 12 25 DSC2 output (-)
CH12 Input (+) 11 30 CH12 output (-) 3 TD+ RD+
6 LAN DSC RX- Ground 13
CH12 Input (-) 12 31 CH11 output (+) 4 TD- RD-
CH11 Input (+) 13 32 CH11 output (-) LINE IN
CH11 Input (-) 14 33 Ground 1 0V or (+48V)
Ground 15 34 CH10 output (+) 2 -48V or (0V)
CH10 Input (+) 16 35 CH10 output (-) 3
CH10 Input (-) 17 36 CH9 output (+) 4
CH9 Input (+) 18 37 CH9 output (-)
CH9 Input (-) 19
OW HEADSET JACK
IF IN/OUT
When PM card is not
Frame
mounted on the
Ground
equipment NMS port is
TRAFFIC IN/OUT ( CH 1 TO CH 8 ) used as RA port. NMS
CH8 Input (+) 1 20 CH8 output (+)
port or NMS LAN
CH8 Input (-) 2 21 CH8 output (-)
CH7 Input (+) 3 22 CH7 output (+) depends on the PM card
ALM
CH7 Input (-) 4 23 CH7 output (-)
ALM RL1 (COM) 1 20 ALM RL5 (COM) Type
Ground 5 24 Ground
ALM RL1 (NO) 2 21 ALM RL5 (NO)
CH6 Input (+) 6 25 CH6 output (+)
ALM RL1 (NC) 3 22 ALM RL5 (NC) AUX ALM NMS RA PORT LA PORT
CH6 Input (-) 7 26 CH6 output (-)
ALM RL2 (COM) 4 23 ALM RL6 (COM) HK1 ALM Input(+) 1 14 HK1 CTRL OUT (PAMS) TXD 1 RA TXD 1 TXD
CH5 Input (+) 8 27 CH5 output (+)
ALM RL2 (NO) 5 24 ALM RL6 (NO) HK1 ALM Input (-) 2 15 HK1 CTRL OUT EMS TXD/TXD+ 2 RA GND 2 GROUND
CH5Input (-) 9 28 CH5 output (-)
ALM RL2 (NC) 6 25 ALM RL6 (NC) HK2 ALM Input(+) 3 16 HK2 CTRL OUT EMS RXD/TXD- 3 RA RXD 3 RXD
Ground 10 29 CH4 output (+)
ALM RL3 (COM) 7 26 ALM RL7 (COM) HK2 ALM Input (-) 4 17 HK2 CTRL OUT EMS TXDR 4 RA RTS 4 RTS
CH4 Input (+) 11 30 CH4 output (-)
ALM RL3 (NO) 8 27 ALM RL7 (NO) HK3 ALM Input (+) 5 18 HK3 CTRL OUT EMS TRS/RXD+ 5 RA CTS 5 CTS
CH4 Input (-) 12 31 CH3 output (+)
ALM RL3 (NC) 9 28 ALM RL7 (NC) HK3 ALM Input (-) 6 19 HK3 CTRL OUT EMS CTS/RXD- 6 6
CH3 Input (+) 13 32 CH3 output (-)
ALM RL4 (COM) 10 29 ALM RL8 (COM) HK4 ALM Input (+) 7 20 HK4 CTRL OUT GROUND 7 7
CH3 Input (-) 14 33 Ground
ALM RL4 (NO) 11 30 ALM RL8 (NO) HK4 ALM Input (-) 8 21 HK4 CTRL OUT 8 8 GROUND
Ground 15 34 CH2 output (+)
ALM RL4(NC) 12 31 ALM RL8 (NC) HK5 ALM Input (+ 9 22 Remote SW (com) PAMS RXD 9 9
CH2 Input (+) 16 35 CH2 output (-)
13 32 HK5 ALM Input (-) 10 23 Remote SW Release NMS TXD/TXD+ 10 10
CH2 Input (-) 17 36 CH1 output (+)
Buzzer output 14 33 HK6 ALM Input (+) 11 24 Remote CH1 Sel NMS RXD/TXD- 11 11 LOCAL CTS
CH1 Input (+) 18 37 CH1 output (-)
Buzzer input 15 34 HK6 ALM Input (-) 12 25 Remote CH2 sel NMS TXDR 12 12 LOCAL RTS
CH1 Input (-) 19
16 35 Ground 13 NMS RTS/RXD+ 13 13 LOCAL RXD
17 36 NMS CTS/RXD- 14 14 GROUND
18 37 15 15 LOCAL TXD
Ground 19
Pasolink V4 34
ALM / AUX Connectors
AUX Connector (1+1)
Input Input Input Input Input Input
#6 #5 #4 #3 #2 #1
13 12 11 10 9 8 7 6 5 4 3 2 1
25 24 23 22 21 21 19 18 17 16 15 14
Remote Switching
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
C4 C3 C2 C1
C8 C7 C6 C5
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
Not Used
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
Pasolink V4 35
OW / DSC / ASC Connector
ASC/ ASC/
64K CLK DSC DSC
INPUT INPUT IN INPUT INPUT
OW IN
Option
G
13 12 11 10 9 8 7 6 5 4 3 2 1
OW Back to Back
Option
DSC DSC INPUT INPUT OW IN INPUT INPUT
Option
Connection
OUTPUT OUTPUT
G
13 12 11 10 9 8 7 6 5 4 3 2 1
25 24 23 22 21 20 19 18 17 16 15 14
25 24 23 22 21 20 19 18 17 16 15 14
Pasolink V4 36
INTERFACES
NEC PASOLINK SYSTEM HAS THE FOLLOWING ITU-T STANDARD INTERFACES
In the case of Nx2 Mbit/s systems, each I/O port is independent ,therefore the 2
Mbit/s signal can be used for different applications
Pasolink V4 37
INTERFACES
SERVICE CHANNELS
Pasolink V4 uses six Service Channels in its radio overhead frame
Pasolink V4 38
INTERFACES
MAIN INTERFACE, ETHERNET (10/100BASE-T(X)
Type : SELECTABLE TRANSMISSION RATES FOR ETHERNET PORTS AND E1 CHANNELS
Store-and-Forwarding 16 Mbps - 0
32 Mbps - 0
Transmission Rate:
Ethernet Ports and E1 ports can be used at the same time. The number
2Mbps to 32 Mbps (selectable) of E1 ports available in this case depends on the Ethernet ports
Depends on the system transmission rate.
Pasolink V4 39
APPLICABLE TRAFFIC CHANNEL
Pasolink V4 40
APPLICABLE TRAFFIC CHANNEL
10/100 Base-T Channels used for LAN
SYSTEM Applicable Traffic CH Number to use 2 MB
PORT1 PORT2 PORT1 PORT2
Disable Disable -- -- CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9,
CH10, CH11, CH12, CH13, CH14, CH15, CH16
2M Disable CH1 -- CH2, CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10,
CH11, CH12, CH13, CH14, CH15, CH16
2M 2M CH1 CH9 CH2, CH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11,
CH12, CH13, CH14, CH15, CH16
4M Disable CH1,CH2 -- CH3, CH4, CH5, CH6, CH7, CH8, CH9, CH10, CH11,
CH12, CH13, CH14, CH15, CH16
4M 2M CH1,CH2 CH9 CH3, CH4, CH5, CH6, CH7, CH8, CH10, CH11, CH12,
CH13, CH14, CH15, CH16
4M 4M CH1,CH2 CH9,CH10 CH3, CH4, CH5, CH6, CH7, CH8, CH11, CH12, CH13,
CH14, CH15, CH16
16 x 2MB 8M Disable CH1,CH2,CH3,CH4 -- CH5, CH6, CH7, CH8, CH9, CH10, CH11, CH12, CH13,
CH14, CH15, CH16
8M 2M CH1,CH2,CH3,CH4 CH9 CH5, CH6, CH7, CH8, CH10, CH11, CH12, CH13,
CH14, CH15, CH16
8M 4M CH1,CH2,CH3,CH4 CH9,CH10 CH5, CH6, CH7, CH8, CH11, CH12, CH13, CH14,
CH15, CH16
8M 8M CH1,CH2,CH3,CH4 CH9,CH10,CH11,CH12 CH5, CH6, CH7, CH8, CH13, CH14, CH15, CH16
16M Disable CH1 TO CH8 -- CH9, CH10, CH11, CH12, CH13, CH14, CH15, CH16
16M 2M CH1 TO CH8 CH9 CH10, CH11, CH12, CH13, CH14, CH15, CH16
16M 4M CH1 TO CH8 CH9,CH10 CH11, CH12, CH13, CH14, CH15, CH16
16M 8M CH1 TO CH8 CH9,CH10,CH11,CH12 CH13, CH14, CH15, CH16
16M 16M CH1 TO CH8 CH9 TO CH16 --
32M Disable CH1 TO CH16 --
Pasolink V4 41
32TS:256bits/125us
8bit
Pasolink V4 42
INTERFACES
Pasolink V4 43
START UP / SHUTDOWN
No.1 CH Power Switch No.1 CH Line IN
START UP
Check that the LINE IN voltage is
between 20 V to 60V (or 20 V to
72 V) with a digital multi-meter, before
connecting the power connector to the
IDU
Turn ON the Power switch on the IDU
Allow equipment to warm up for at least 30
minutes
SHUT DOWN
Turn OFF the power switch on the front of
the IDU No.2 CH Line IN
No.2 CH Power Switch
Pasolink V4 44
PROTECTION SWITCHING
Protection switching in Pasolink (1+1 ) system has several switching priorities.
RX switching
TX switching
When the Online RX CH fails,
In the (1+1)HS system
the ALM CONT circuit in the
transmit switching is carried
SW Board initiate a RX SW
out by setting the standby
Control signal to switch to the
ODU out put to off by Muting
standby CH provided it is in
it. The data signal is
normal operating condition.
transmitted in parallel to both
CH1 and CH2. RX LEV ALM
TX PWR ALM RX LO APC ALM
TX LO APC ALM DEM ALM
ODU IF INPUT ALM FSYNC ALM
HIGH BER ALM
MOD ALM
OPR ALM
TX DPU ALM CPU ALM
CPU ALM
When Hitless switch is used make sure that the difference between the two IF cable lengths are less than 50 meters
Pasolink V4 45
Protection Systems
ODU-1 ODU-1
Modem - 1 Modem - 1
Hot Standby - Single
Switch H H Switch
Antenna System
Modem - 2 Modem - 2
ODU-2 ODU-2
Hitless or Ordinary SW (RX)
ODU-1 ODU-1
Modem - 1 Modem - 1
Switch Switch
Modem - 2 Modem - 2
ODU-2 ODU-2
Hot Standby - Two
Antenna System
However, errors persist when Tx is switched to the other side because of equipment
failure. Tx side does not have protection against switching.
ODU-1 ODU-1
Modem - 1 Modem - 1
Switch Twin Path Switch
Modem - 2 Modem - 2
ODU-2 ODU-2
Pasolink V4 46
Automatic Transmit power control (ATPC)
Pasolink V4 47
AUTOMATIC TX POWER CONTROL
Tx Out
High
Max. Tx Lev
(Provisioning)
Min Tx Lev
(Provisioning)
Low Fading
Deep Shallow
The ATPC Control transmits the information on the
receiving level to the opposite station and controls
Rx Lev
the transmission level of its own station in
High accordance with the receiving level of the opposite
station.
ATPC hysteresis
(provisioning)
ATPC Rx Threshold The ATPC Control can be used in several configurations:
(provisioning)
ATPC - ATPC
MTPC - ATPC
Low ATPC - MTPC
Deep
Fading
Shallow
Pasolink V4 48
OW COMMUNICATION
OW/DSC/ASC OW /DSC/ASC
Communication between Local IDU and Remote IDU
5 EOW input (+) 5 EOW input (+)
6 EOW input (-) 6 EOW input (-)
Communication between Local ODU and Remote IDU 18 EOW output (+) 18 EOW output (+)
19 EOW output (-) 19 EOW output (-)
Communication between Local ODU and Remote ODU
When the Call button on the IDU is pressed the buzzer
When back-to-back connection for order wire is provided, sounds on the remote IDU and all the other IDUs
OW communication between different hops are possible. connected through back-to back connections.
Pasolink V4 49
OW/RX LEV MONITOR
Meter Indicates the Receive
level as a dc voltage
OW Indicator Lights when the
OW-ON/OFF switch is set to ON.
Under this condition if the indicator is
not lit replace the battery.
Pasolink V4 51
ALARM TABLE
IDU/ODU ALM LED LIGHT
NE LB CONT 1-16
FE LB CONT 1-16
RX CLOCK LOSS
BP OUTPUT 1-16
INPUTLOSS 1-16
TX CLOCK LOSS
NE LB ANS 1-16
FE LB ANS 1-16
AIS RCVD 1-16
AIS SEND 1-16
IF INPUT ALM
TX PWR ALM
RX LEV ALM
FSYNC ALM
MAINT LED LIGHT
MAINT LED
M
APC 1 ALM
HBER ALM
LBER ALM
APC2 ALM
MOD ALM
DEM ALM
OPR ALM
ODU LED
BER ALM
IDU LED
RX ALM
TX ALM
IDU/ODU LED BLINKS
MAINT
BER
LCT ALM INDICATION
ALM MASK
SOMETIMES ALM
LED ALM RELAY LCT IDU ALM LCT ODU ALM LCT MAINT
INPUT LOSS 1-16
INPUT LOSS 1-16 (REMOTE)
INPUT LOSS 1-16 (REMOTE) (AIS SEND ON)
AIS RCVD 1-16
AIS RCVD 1-16 (AIS RCVD ON)
TX CLOCK LOSS
RX CLOCK LOSS
BER 1X10-6
BER 1X10-3
BER THRESHOLD
IF CABLE OPEN
TX PWR ALM
RX LEV ALM
LOSS OF RECEIVE RF SIGNAL
APC1 ALM
APC2 ALM
IF INPUT ALM
CW M
CW (REMOTE)
MUTE M
MUTE (REMOTE)
FE LOOPBACK M
FE LOOPBACK (REMOTE) M Z
NE LOOP BACK M
NE LOOP BACK (REMOTE)
CH ALM INHIBIT
FRAME ID DIFFERENT
Pasolink V4 52
17710.00MHz (1)
238.75MHz (A)
17948.75MHz (192')
17950.00MHz (1)
246.25MHz (B)
18196.25MHz (198')
1010MHz
18197.50MHz (1)
Pasolink V4
246.25MHz (C)
18443.75MHz (198')
1010MHz
18445.00MHz (1)
18720.00MHz (1)
240.00MHz (D)
18685.00MHz (193')
1010MHz
238.75MHz (A)
18958.75MHz (192')
18960.00MHz (1)
1010MHz
Pasolink V4 ODU - 18GHz Frequency Plan
246.25MHz (B)
19453.75MHz (198')
19455.00MHz (1)
240.00MHz (D)
19695.00MHz (193')
53
Installation
Before going to any site,
please be sure you completely prepared the following items:
1-The installation tools.
2-The test equipment ,materials ,and tools.( for test work
only)
3-Site installation drawings.
4-All labels/stickers (hard and soft copy)
5-Frequency plan and system configuration documents.
6-Test procedure and test data sheets .( for test work only)
7-Confirm access to site/station.
8-Check the condition of the vehicle to be used.
9-Make sure you and your staff are in good conditions
(physically)
10-Confirm the site/station entrance conditions.
11-Move to site/station safely.
Pasolink V4 54
INSTALLATION
- Link Design
RF spot ,Capacity , Redundancy , Antenna size, Rx level ,Tx power ,Link availability
- RFI Survey
Out door (LOS, Tower , grounding , Antenna mount , Cable tray )
In door ( feeder entrance ,19 rack , DC power , AC ,DDF , cable tray, grounding)
Pasolink V4 55
1-INDOOR
1-INDOOR Unpackingofof
Unpacking Unpacking
Unpacking Unpackingofof19"
19"
Unpacking
INSTALLATION Accessories
Accessories ofIDU
of IDU rack(if
(ifsupplied)
supplied)
INSTALLATION rack
IFConnector
IF Connector&&Power
Power
Connectortermination
termination Confirm 19" Rack Location
Connector
& DC-Power Source
19"rack
19" rackfixing
fixing
FollowThe
Follow The
terminationProcedure
termination Procedure IDU
Mounting
RackEarthing
Rack Earthing
Connection
Connection
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection
IDUGrounding
IDU GroundingConnection
Connection
Pasolink V4 57
75 / 120 TERMINATION
75 Ohms or 120 Ohms impedance
for the 2 Mbps channel is selected
from the front board. Usually set in
the factory according to the
customer requirements
Pasolink V4 58
IDU MOUNT
FRONT POSITION
WALL
Pasolink V4 59
1-OUTDOOR
1-OUTDOOR Unpackingofof
Unpacking Unpacking
Unpacking Unpackingofof
INSTALLATION
INSTALLATION Accessories ofODU
ODU
Unpacking
Accessories of Antenna
Antenna
FLOWCHART
FLOW CHART
IFConnector
IF Connector Removethe
Remove theODU
ODU Antenna bracket
cover,Confirm
cover, Confirmthe
the assembling,
Polarity
Polarity Confirm the Polarity
FollowThe
Follow The
terminationProcedure
termination Procedure ODU
Mounting Refer to the Antenna
assembling guide
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection
ODUGrounding
ODU GroundingConnection
Connection
V-POL
HYBRID
H-POL
Antenna
connection unit
Antenna direct
mounting type
ODU
PROCEDURE FOR SETTING V/H POLARIZATION
Pasolink V4 61
H-POL
V-POL
Pasolink V4 62
ANTENNA DIRECT MOUNT V/H POL
When vertical polarization is required, rotate the When horizontal polarization is required, rotate the
IDU so that the plate marked with V is pointing up. IDU so that the plate marked with H is pointing up.
Fix the ODU in this position Fix the ODU in this position
Pasolink V4 63
POLE MOUNTING BRACKET
Pasolink V4 64
WALL MOUNTING BRACKET
BOLT
Pasolink V4 65
Antenna Direct Mount Type
1.Mount the Hybrid to the Antenna with screws, use the 2.Fix the ODUs one by one to the Hybrid. Take care not to
guide pins to position correctly damage the o-rings.
Pasolink V4 66
Antenna connection using WG
Pasolink V4 67
DIFFERENT ODU MOUNTINGS
Pasolink V4 68
DIFFERENT ODU MOUNTINGS
Pasolink V4 69
DIFFERENT ODU MOUNTINGS
ODU 1
HYBRID
ODU 2
Antenna
Pasolink V4 70
DIFFERENT ODU MOUNTINGS
ODU
NE001 or NE002
Antenna
IDU(1+1)
DC PDB
MDP 1
MDP2
CPU
Antenna
ODU
227 ICE 02 (RV) 1.5mm2 (Blue and Red) OT1.5-4
SN-5D-HFB
N-LP-5DFB
N-LP-5DFB
N-LP-5DFB SN-5D-HFB
LAN cable(10/100BaseT) N-LP-5DFB
Tower
OT14-6
To be prepared by Naja
Supplied equipment
Pasolink V4 72
CABLE TERMINATION
1-IF Connector Termination
1-Connector Material
Check
Verify that all connector
Accessories are complete as
1- Lock Nut
2- Washer
3- Gasket
4- Clamp A
5- Clamp B
6- Center Conductor
7- Insulation
8- Connector Shell
Pasolink V4 73
Luck Nut
Washer
Gasket
Clamp A
Clamp B
Insulation
Center Conductor
Connector Shell
IF Cable Termination
1-First, Fit the Lock Nut, Washer
and Gasket on the Cable as
shown
Gasket
washer
Lock Nut
Pasolink V4 75
2-Strip Back the cable sheath,
taking care not to damage the
braided shield.
Fit Clamp A
Pasolink V4 NESIC
76 CAIRO
3-Fold back the Braided shield,
Separating the strands of the braid.
Cut the
extra length,
to fit to
Clamp A
Pasolink V4 77
4-Cut away the insulation from
the center conductor and fit
the clamp B.
Pasolink V4 79
8-Insert the cable into the
connector shell
Pasolink V4 82
CONNECTOR &POWER
CABLE
Power
Connector
Socket Contact
Power
Cable
1-Remove 3.0 to 3.5 mm of Insulation 1
2
2- Set the socket contact to the following
position onto the hand crimping tool
Pasolink V4 84
3- Squeeze the handle of the hand crimping tool, insert cable into socket
contact
4- Cable should fit, so insulation and bare wire are arranged as shown,
5- Squeeze the handle of the hand crimping tool until ratchet is released.
Pasolink V4 85
5-Squeeze the
handle of the hand
crimping tool until
ratchet Is released
(0 V)
Pasolink V4 89
For Andrew VHP( )-( )-NC3 Antenna
Pasolink V4 90
7/8 GHz BAND ODU
Pasolink V4 91
ORDER-WIRE TESTS
Connect the OW/RX LEV MONITOR to the RX LEV
MON connector on the ODU.
Connect Headsets to the EOW Jacks on the front
panel of the local and remote IDUs and Headset
Jack on the OW/ RX LEV MONITOR.
Press the Call Button on the local IDU and confirm
that the buzzer on the opposite IDU is activated..
Confirm that OW communication between Local IDU
and the Remote IDU is possible.
Confirm that OW communication between Local IDU
and the local ODU and/ or opposite ODU is possible Note:
It is possible to extend the OW communication to
Confirm that OW communication between Local other Hops in the link. Establish back-to-back
ODU and the opposite ODU is possible connections as shown.
Disconnect the headsets and OW/RX LEV monitors.
Pasolink V4 92
Pasolink Equipment
Maintenance
** Types of Maintenance
1- Preventive Maintenance ( periodical )
2- Corrective Maintenance
** Precautions
Before beginning maintenance, notify the opposite station that
maintenance is about to begin.
After equipment starts-up, allow the equipment to warm up for at least
30 minutes.
During maintenance, set the IDU to maintenance mode using a PNMT
according to the user manual.
After completing the maintenance operation, restore all connections to
normal.
Pasolink V4 94
Required tools & test equipments
ITEM Remarks Qty
Headset - 1 each
Pasolink V4 95
1- Preventive Maintenance
Frequency of preventive maintenance
Pasolink V4 96
Preventive Maintenance Procedures
1- Radio Equipment
Visual inspection
Meter reading
Check configurations
2- Aerial Equipment
Visual inspection
Check loose bolt connections
Rust prevention
3- Interface Cables and Connectors ( RF, IF cables ,
grounding . Power supply, main traffic , alarm , service channels ,NMS cables and connectors )
Visual inspection
Check loose bolt connections
Check waterproofing treatment
Pasolink V4 97
P r e ve n t ive Ma in t e n a n ce Ch e e k List
Site Name:_________________
Check Date
Equipment Location Check Item / / / / / / / /
Radio ODU Visual
IDU Visual
IDU through PNMT ODU primary power supply
Transmitter Power
Receiving Level
Configuration Setting
Aerial Antenna Visual
Pasolink V4 98
S i te In ve n tory Da ta Re cord S h e e t
Site Name:_________________
Installation Date:_________________
To:
ODU1 Serial No.: Tx Frequency: Rx Frequency:
--------- MHz --------- MHz
Channel No.: Channel No.:
Transmitter Power: Receiving Level:
--------- dBm --------- dBm
ODU2 Serial No.: Tx Frequency: Rx Frequency:
--------- MHz --------- MHz
Channel No.: ( ) Channel No.: ( )
Transmitter Power: Receiving Level:
--------- dBm --------- dBm
Primary DC voltage:
------- V
Pasolink V4 99
Preventive Maintenance Flow Chart
Start
Radio Interface
Aerial
Equipment cables and
Equipment
connectors
* Tx Power
* Rx Signal level Check Water
Rust Prevention
* No up normal alarms proofing
Go To
Check
Corrective
Configuration
Maintenance
End
Pasolink V4 100
2- Corrective Maintenance
Corrective Maintenance Procedures
1-Radio equipments
Fault Isolation
( LED , Internal alarms , BB loop back , event log & link performance)
Rectify the fault reason or replace the faulty part
2- Aerial equipment
Antenna alignment
Antenna Rust
Surface Damage
3- Interface Cables & Connectors
Check for Damages in Cables and connectors
Loose connections
Water ingress
Pasolink V4 101
Corrective Maintenance Flow Chart
Start
Interface
Radio Aerial
cables and
Equipment Equipment
connectors
Rectify the
problem cause
Pasolink V4 102
List of check items against alarm item (for PASOLINK 1 + 0)
IDU Alarms
Alarm Description Equipment where Alarm is from
Alarm Items
Items to Check Possible Cause of Failure or Action to
Take
Loss of input data stream from DTE IDU
a) Check DTE DTE
1 INPUT -CH 01-16
b) Check data input cable and connector Data input cable and connector failure
failure (short-circuit)
a) Check wayside data output cable Data output cable and connector
8 WS OUTPUT and connector. failure
Pasolink V4 104
List of check items against alarm item (for PASOLINK 1 + 0)
IDU Alarms
Alarm Description Equipment where Alarm is from
Alarm Items Items to Check Possible Cause of Failure or
Action to Take
INTFC Receiver Clock Loss <Note 1> IDU
a) Check RX LEVEL Antenna system or natural fading
11 MUX Alarm a) Check data rate setting using LCT or PNMT/S. IDU data rate setting
12 TX DPU a) Check data rate setting using LCT or PNMT/S. IDU Data rate setting
THANK YOU
Pasolink V4 108