Académique Documents
Professionnel Documents
Culture Documents
11.12.2016
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table
CIE flux code: 44 79 98 100 79 can be displayed for this luminaire.
NIKKON S412-150 M0150 Street Lantern c/w MH 150W Tube Lamp
Operator
Telephone
Fax
e-Mail
Street Profile
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Grid: 10 x 6 Points
Observer Position: (-60.000 m, 1.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.19 0.54 0.85 6
Required values according to class ME4a: 0.75 0.40 0.60 15
Fulfilled/Not fulfilled:
Operator
Telephone
Fax
e-Mail
Grid: 10 x 6 Points
Observer Position: (-60.000 m, 5.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.03 0.51 0.72 6
Required values according to class ME4a: 0.75 0.40 0.60 15
Fulfilled/Not fulfilled:
Operator
Telephone
Fax
e-Mail
Grid: 10 x 6 Points
Observer Position: (-60.000 m, 9.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.03 0.51 0.72 6
Required values according to class ME4a: 0.75 0.40 0.60 15
Fulfilled/Not fulfilled:
Operator
Telephone
Fax
e-Mail
Grid: 10 x 6 Points
Observer Position: (-60.000 m, 13.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.19 0.54 0.85 6
Required values according to class ME4a: 0.75 0.40 0.60 15
Fulfilled/Not fulfilled: