Vous êtes sur la page 1sur 7

Project 1

11.12.2016

Operator
Telephone
Fax
e-Mail

NIKKON S412-150 M0150. / Luminaire Data Sheet

Luminous emittance 1:

Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table
CIE flux code: 44 79 98 100 79 can be displayed for this luminaire.
NIKKON S412-150 M0150 Street Lantern c/w MH 150W Tube Lamp

DIALux 4.12 by DIAL GmbH Page 1


Project 1
11.12.2016

Operator
Telephone
Fax
e-Mail

Street 1 / Planning data

Street Profile

Roadway 2 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)


Median 1 (Width: 1.000 m, Height: 0.000 m)
Roadway 1 (Width: 7.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)

Maintenance factor: 0.67


Luminaire Arrangements

Luminaire: NIKKON S412-150 M0150.


Luminous flux (Luminaire): 10725 lm Maximum luminous intensities
Luminous flux (Lamps): 13500 lm at 70: 382 cd/klm
Luminaire Wattage: 204.7 W at 80: 61 cd/klm
Arrangement: on Median at 90: 12 cd/klm
Pole Distance: 15.000 m Any direction forming the specified angle from the downward vertical, with the luminaire
Mounting Height (1): 8.000 m installed for use.
Height: 8.013 m Arrangement complies with luminous intensity class G3.
Overhang (2): 2.050 m Arrangement complies with glare index class D.6.
Boom Angle (3): 15.0
Boom Length (4): 2.502 m

DIALux 4.12 by DIAL GmbH Page 2


Project 1
11.12.2016

Operator
Telephone
Fax
e-Mail

Street 1 / Luminaire parts list

NIKKON S412-150 M0150.


Article No.: S412-150
Luminous flux (Luminaire): 10725 lm
Luminous flux (Lamps): 13500 lm
Luminaire Wattage: 204.7 W
Luminaire classification according to CIE: 100
CIE flux code: 44 79 98 100 79
Fitting: 1 x MH 150W Tube Lamp (Correction
Factor 1.000).

DIALux 4.12 by DIAL GmbH Page 3


Project 1
11.12.2016

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Observer 1 / Isolines (L)

Values in Candela/m, Scale 1 : 151

Grid: 10 x 6 Points
Observer Position: (-60.000 m, 1.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.19 0.54 0.85 6
Required values according to class ME4a: 0.75 0.40 0.60 15

Fulfilled/Not fulfilled:

DIALux 4.12 by DIAL GmbH Page 4


Project 1
11.12.2016

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Observer 2 / Isolines (L)

Values in Candela/m, Scale 1 : 151

Grid: 10 x 6 Points
Observer Position: (-60.000 m, 5.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.03 0.51 0.72 6
Required values according to class ME4a: 0.75 0.40 0.60 15

Fulfilled/Not fulfilled:

DIALux 4.12 by DIAL GmbH Page 5


Project 1
11.12.2016

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 2 / Observer 3 / Isolines (L)

Values in Candela/m, Scale 1 : 151

Grid: 10 x 6 Points
Observer Position: (-60.000 m, 9.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.03 0.51 0.72 6
Required values according to class ME4a: 0.75 0.40 0.60 15

Fulfilled/Not fulfilled:

DIALux 4.12 by DIAL GmbH Page 6


Project 1
11.12.2016

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 2 / Observer 4 / Isolines (L)

Values in Candela/m, Scale 1 : 151

Grid: 10 x 6 Points
Observer Position: (-60.000 m, 13.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m] U0 Ul TI [%]
Calculated values: 3.19 0.54 0.85 6
Required values according to class ME4a: 0.75 0.40 0.60 15

Fulfilled/Not fulfilled:

DIALux 4.12 by DIAL GmbH Page 7