4-E1/T1 signal cables include the 75-ohm E1 coaxial cable, 120-ohm E1 twisted pair cable, and 100-ohm T1 twisted pair cable. The connector at one end of the trunk cable is DB26
male connector, and the connector at the other end needs to be assembled on the basis of onsite requirements.
A 75-ohm coaxial cable consists of eight coaxial wires and provides four E1 links.
A 100-ohm twisted pair cable consists of eight pairs of (16) wires and provides four T1 links.
A 120-ohm twisted pair cable consists of eight pairs of (16) wires and provides four E1 links.
Installation Position
When the UELP is configured: OUTSIDE port on the UELP Transmission equipment or BSC
When the UELP is not configured: E1/T1 port on the CMPT (4-E1)
NOTE:
If there is no engineering survey at home, the default connector between the 75-ohm E1 cable and the transmission equipment is the L9 connector.
Table 2 lists the mapping between the 75-ohm coaxial cable and the DB26 connector.
Table 2 Mapping between the 75-ohm coaxial cable and the DB26 connector
Cable Cable No. Start Point End Point Signal Remarks
X.2 Ring1
X.20 Ring2
X.4 Ring3
X.22 Ring4
http://localhost:7890/pages/31184377/01/31184377/01/resources/bts/bbu3900-user-guide/b... 6/28/2011
4-E1/T1 Signal <span class="hedex_lite_highlight_result" style="background:#ffff66;col... Page 2 of 3
X.6 Ring5
X.24 Ring6
X.8 Ring7
X.26 Ring8
NOTE:
When installing the 100-ohm twisted pair cable, cut off the remaining unused portion of the cable, and pay attention to the mapping between the twisted pair cables and the DB26
connectors.
Table 3 lists the mapping between 100-ohm twisted pair cables and DB26 connectors.
Table 3 Mapping between 100-ohm twisted pair cables and DB26 connectors
Cable Start Point Sheath Color Signal Remarks
X.20 White
X.2 White
X.22 Red
X.4 White
X.24 Red
X.6 White
X.26 Red
X.8 White
http://localhost:7890/pages/31184377/01/31184377/01/resources/bts/bbu3900-user-guide/b... 6/28/2011
4-E1/T1 Signal <span class="hedex_lite_highlight_result" style="background:#ffff66;col... Page 3 of 3
Table 4 lists the mapping between 120-ohm twisted pair cables and DB26 connectors.
Table 4 Mapping between 120-ohm twisted pair cables and DB26 connectors
Cable Start Point Sheath Color Signal Remarks
X.20 White
X.2 White
X.22 Red
X04 White
X.24 Red
X.6 White
X.26 Red
X.8 White
http://localhost:7890/pages/31184377/01/31184377/01/resources/bts/bbu3900-user-guide/b... 6/28/2011