Académique Documents
Professionnel Documents
Culture Documents
HLS 200
1
Dimensions
Type 1: M12 x 1 Type 2: DT-04
48.9
47
38
27.2 27.2
43.4
43.4
35.5
35.5
32.2
32.2
1 2
4 3
1 2 4 3
Connection Connection
M12x1 4-pole DT-04 4-pole
Connector
Pin 1 + Ucc
Pin 2 Out (spool out (+))
Pin 3 GND
Pin 4 Out (spool in (-))
33-02-HLS200-02 /04.13
2
Function
For the spool in neutral position (I) both
outputs O2 and O4 will be at high level.
If the spool moves out of neutral position in
the direction to spool in (III) O4 will be at
low level and O2 at high level.
When the spool is out of neutral position in
the direction to spool out (II) O2 will be at
low level and O4 at high level.
In case of a sensor error condition, Symbol
both O2 and O4 will be at low level
simultaneously.
HLS 200
Rod with
detection flag
33-02-HLS200-02 /04.13
3
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications or operating
conditions not described, please
contact the relevant technical department.
Subject to technical modifications.
33-02-HLS200-02 /04.13