Vous êtes sur la page 1sur 6

Pressure Operations Manual

Appendix H - WIRELINE

Pressure Operations Manual

Appendix H

RITE Naming Convention

A WIRELINE Section

Schlumberger Private
Legal Information

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved.

This work contains the confidential and proprietary trade secrets of Schlumberger
and may not be copied or stored in an information retrieval system, transferred,
used, distributed, translated or retransmitted in any form or by any means,
electronic or mechanical, in whole or in part, without the express written
permission of the copyright owner.

Trademarks & service marks

"Schlumberger", the Schlumberger logotype, and other words or symbols used


to identify the products and services described herein are either trademarks,
trade names or service marks of Schlumberger and its licensors, or are the
property of their respective owners. These marks may not be copied, imitated
or used, in whole or in part, without the express prior written permission of
Schlumberger. In addition, covers, page headers, custom graphics, icons, and
other design elements may be service marks, trademarks, and/or trade dress
of Schlumberger, and may not be copied, imitated, or used, in whole or in part,
without the express prior written permission of Schlumberger.
A complete list of Schlumberger marks may be viewed at the Schlumberger
Oilfield Services Marks page: http://www.hub.slb.com/index.cfm?id=id32083
Marks of Schlumberger include but may not be limited to :

th
Revision 5.1: May 17 , 2005 Approved By: Tom Teipner,

Appendix H : Page 1 of 6 WL QHSE and Operations Support Manager

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved


Pressure Operations Manual
Appendix H - WIRELINE

(This page is intentionally blank)

Schlumberger Private

th
Revision 5.1: May 17 , 2005 Approved By: Tom Teipner,

Appendix H : Page 2 of 6 WL QHSE and Operations Support Manager

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved


Pressure Operations Manual
Appendix H - WIRELINE

Appendix H RITE Naming Convention.


In an effort to standardise the convention used for the WHE equipment in the field the following naming convention
should be implemented for all assets as entered into RITE version 1.7 or later. All of your existing assets in use in
the location today should be renamed in RITE with this standard system.

All components of the WHE system must be managed and tracked individually e.g. BOP, Tool Catcher, Grease
Head, Crossovers, Pressure Skid etc. and must be entered into the RITE system. All of the information fields on the
equipment description; pressure rating; connection types; certification status etc, shall be completed in RITE
database.

See table H-1 below for the asset naming convention, table H-2 for the WHE Toolset naming convention and table
H-3 for Auxiliary Equipment.

To avoid duplication of equipment name and serial numbers in the RITE system all items, currently in the field,
should be given a new asset serial number beginning with the location code/number followed by a three-digit
number (e.g. ADT-001, 864-001 etc.)

In the future equipment will be delivered from the suppliers with the new RITE asset code already stamped on the
equipment and recorded in the equipment quality file. For this pre-stamped equipment a serial number (taken from
the suppliers manufacturing job number) will also have been marked on the equipment. If present this serial number
should be used as the asset serial number and recorded into RITE and the fixed asset list.

(The rest of this page is intentionally blank)

Schlumberger Private

th
Revision 5.1: May 17 , 2005 Approved By: Tom Teipner,

Appendix H : Page 3 of 6 WL QHSE and Operations Support Manager

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved


Pressure Operations Manual
Appendix H - WIRELINE

Table H-1 RITE Asset Name Convention.


The Asset Name in RITE must have the following form: WaabyyKz.z

Where W Indicates that the asset is a WHE Pressure Component (used for sorting)

aa Asset Type as per the list below.

b Defines if equipment is for Standard (S) or H2S (H) service

yy Pressure Rating (working) in Kpsi (ie 03, 05, 10 or 15)

z.z The nominal equipment ID in inches.

Asset Type Name Code: BS BOP Single Ram (hydraulic or manual)

BD BOP Double Ram (hydraulic or manual)

BT BOP Triple Ram (hydraulic or manual)

BG BOP Grease Pack (hydraulic or manual)

DG BOP Double Grease Pack (hydraulic or manual)

TT Tool Trap

QT Quick Test Sub

RL Riser or Lubricator

TC Tool Catcher (may include integral Ball Check Valve)

BV Ball Check Valve

Schlumberger Private
SB Stuffing Box for HGT-D

GT Grease Tube / Flow Tubes

FC Flow tube coupling

BO Bell Oil Saver / Line Wiper

WS Combination Line Wiper / stuffing box

IH Grease Injection Hose for HGT-D or BOP

GI Grease Injection Unit

CI Chemicals injection sub

IV Isolation Valve, Hydraulic Ball Valves

PS Pump-in Tee Sub or Injection Tee Sub c/w lateral 2" or 3" fig 1502 entry pipe

FL Flanged Adapter or Wellhead Crossover

XO Threaded Connection Crossover or Swedge crossover

HL HLW-B or BOP-V

DP Dual Pack Off HX300 or M3000 or BOP-D

PO Rubber pack off used for Slickline

SK Transport Skid

BC BOP transport cage and working platform

TP Test Plug

PT Field Pressure Test Unit

LB Lifting bail

FD Flow diverter and cable clamp

SN Shooting nipple

th
Revision 5.1: May 17 , 2005 Approved By: Tom Teipner,

Appendix H : Page 4 of 6 WL QHSE and Operations Support Manager

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved


Pressure Operations Manual
Appendix H - WIRELINE

Asset Type Name Code: DL Compact dual pack-off

CC Cable Cutter Sub

TR Telescopic Riser Variable length lubricator


SP Spreader beam and lifting slings

TS Turnaround Sheave (Pressurized Sheave Wheel)

Table H-2 RITE Toolset Name Convention.

Tool Set Names

Where equipment is maintained in sets the assets can be grouped under a Tool Set name as per below:-

WHEbyyKz.z

Where WHE Indicates that this is a tool set of WHE equipment.

b Defines if equipment is for Standard (S) or H2S (H) service

Schlumberger Private
yy Pressure Rating (working) in Kpsi (ie 03, 05, 10 or 15)

z.z The nominal equipment ID in inches.

Equipment Serial Numbers


To avoid duplication of equipment name and serial numbers in the RITE system all items should be
given a new asset serial number beginning with the location code/number followed by a three-digit
number (e.g. ADT-001, 864-001 etc.)

Table H-3 RITE Auxiliary Equipment


Some items used in Pressure control operations have to be tracked for maintenance purpose.
The following codes are available from the FCC listing to be entered in RITE and followed up.

WHE-PUMP : grease injection pumps


WHE-GAUGE : pressure gauges used in conjunction with WHE

(The rest of this page is intentionally blank)

th
Revision 5.1: May 17 , 2005 Approved By: Tom Teipner,

Appendix H : Page 5 of 6 WL QHSE and Operations Support Manager

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved


Pressure Operations Manual
Appendix H - WIRELINE

H. Revision History

Rev No Effective Date Modifications Prepared by (name) Reviewed by (name)


st
3 Oct. 1 , 2001 Release to field Roberto Franco David Clark
th
3.1 Dec 15 , 2001 Correct to include serial no. details Roberto Franco David Clark
th
5.1 May 17 , 2005 Added legal information first page Roberto Franco Jan Vader
+ codes FC, WS, CI, BC, TR, CC,
TS + auxiliary equipment

Latest revision approved by (name): Tom Teipner

Wireline QHSE and Operations Support Manager Signed:

Warning: The controlled source document of this manual section is stored under InTouch content #3046294 Any paper version of this standard is
uncontrolled and should be compared with the source document at time of use to ensure it is up to date.

Schlumberger Private

th
Revision 5.1: May 17 , 2005 Approved By: Tom Teipner,

Appendix H : Page 6 of 6 WL QHSE and Operations Support Manager

Copyright 2005 Schlumberger, Unpublished Work. All rights reserved

Vous aimerez peut-être aussi