The CRM-4 Control Relay Module provides the NOTIFIER
System 5000, AFC-600, AFP-400, or AFP-300 with four 7165-0028:144
Form-C (SPDT) relay contacts which may be used to S635 CS68 7170-0028:154
control auxiliary devices. The CRE-4 Control Relay Ex- 7165-0028:181
pander will provide four additional Form-C (SPDT) relay 7170-0028:182
contracts for a total of eight.
The ARM-4 Auxiliary Relay Module is used for high power BSA MEA
switching and may be slaved to a CRM-4 or CRE-4 mod- Approved 578-81-SA 17-96-E
ule.
Switches are provided for each relay to provide manual City of Chicago
ON/OFF, DISABLE/ENABLE and programming functions.
FEATURES
Four Form-C (SPDT) relay contacts.
May be expanded to eight Form-C relay contacts.
20 amp N.O. (normally open contacts) and 10 amp N.C.
(normally closed contacts) switching with ARM-4.
Green LEDs to indicate relay activation or I/O mapping.
Amber LEDs to indicate relay disabled, module fault or
system communications failure.
Control switch for Manual On/Off, circuit Enable/Disable,
and module programming.
APPLICATIONS
The CRM-4 provides up to four Form-C (SPDT) relay
contacts for auxiliary control functions.
The CRE-4 expands the CRM-4 to a total of eight Form-C
(SPDT) relay contacts.
The ARM-4 module can be used when greater load switch-
ing capability is required. The ARM-4 is slaved to a
CRM-4 or CRE-4 module.
CONSTRUCTION
The CRM-4 consists of a panel mounted printed circuit
card with an integral tactile feel membrane switch. Clear
windows in the membrane panel allow viewing the status
and trouble LEDs. Slide-in pockets allow the insertion of
descriptive labels for the circuits. Removable terminal
blocks are provided for connection of field wiring.
0461crm4.wmf
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications or ISO-9001
anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing
more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 Quality System Certified to
International Standard ISO-9001 Made in the U.S.A.
One Fire-Lite Place, Northford, Connecticut 06472
DN-461 Page 1 of 2
INSTALLATION SPECIFICATIONS
The CRE-4 (if used) mounts to the back of the CRM-4 with Programmable for activation when an alarm is detected
hardware provided. for an individual zone, a group of zones, or all zones.
The CRM-4 mounts in one module position of a CHS-4 Form-C (SPDT) contacts UL rated at 5 amps @ 30 VDC
chassis using two captive screws. The 1st Row or Ex- or 125 VAC (resistive); and 2 amps @ 125 VAC (induc-
pander Ribbon cable connects the CRM-4 to the CPU tive) [CRM-4 and CRE-4 modules].
module. Form-C (SPDT) contacts rated at 20 amps @ 30 VDC or
The ARM-4 is mounted on the rear of the CHS-4 chassis 125 VAC or 250 VAC (normally open contacts) or 10
(adjacent to the controlling CRM-4/CRE-4), and may be amps @ 30 VDC or 125 VAC or 250 VAC (normally closed
located under a IZM-8 or AIM-200 (System 5000 only), contacts) [ARM-4 module].
ICM-4, or CRM-4 (with or without expanders). Standby current consumption:
NOTE: Except in the City of Chicago, the ARM-4 may also be
CRM-4 0.007 amperes.
located under a VCM-4, TCM-2, or TCM-4.
CRE-4 0.000 amperes.
ARM-4 0.000 amperes.
0461arm4.wmf
0669cre4.wmf
Page 2 of 2 DN-461