Breakers and Switches

Switches for photovoltaic applications


Switch-disconnectors
OTDC and OTDCP
Switch-disconnectors
OTDC16...800 and OTDCP16...32

Contents

4 Product overview

8 Technical data

11 Type designation key

12 OTDC1632 ordering information


12 OTDC1632, base mounted, IEC
13 OTDC1632, base mounted, UL
14 OTDC1632, door mounted, IEC
15 OTDC1632, door mounted, UL
16 OTDCP enclosed switches, IEC

18 OTDC100800 ordering information


18 Single circuit, 1000 VDC, IEC
19 Single circuit, 1000 VDC, UL
22 Double circuit and load side combining, 1000 VDC, IEC
23 Double circuit and load side combining, 1000 VDC, UL
26 Triple circuit, 1500 VDC, IEC
28 Single and double circuit, 1500 VDC, IEC
29 Single circuit, 1500 VDC, UL
32 Side operated, Single circuit, 1000 VDC, UL

34 OTDC1632 accessories

38 OTDC100800 accessories

45 Dimension drawings

51 Index

Switches for PV applications | Contents 3


DC switch-disconnectors, front operated
16...800 A, IEC

IEC 60947

OTDC16F2 OTDC16F3 OTDC16F4 OTDC100E02 OTDC100E11


OTDC25F2 OTDC25F3 OTDC25F4 OTDC160E02 OTDC160E11
OTDC32F2 OTDC32F3 OTDC32F4 OTDC200E02 OTDC200E11
OTDC250E02 OTDC250E11
U e [V DC] 660 1000 1000 / 2x660 1000 1000
I e, DC-21B [A] 16 25 32 16 25 32 16 25 32 100 160 200 250 100 160 200 250

IEC 60947

OTDC315E02 OTDC315E11 OTDC315EV12 OTDC315E22 OTDC315E33 OTDC630EPP22


OTDC400E02 OTDC400E11 OTDC400EV12 OTDC400E22 OTDC400E33 OTDC800EPP22
OTDC500E02 OTDC500E11 OTDC500EV12 OTDC500E22 OTDC500E33
Ue [V DC] 1000 1000 1500 1000 1000/1500 1000
I e, DC-21B [A] 315 400 500 315 400 500 315 400 500 315 400 500 315 400 500 630 800

DC switch-disconnectors, enclosed
16...32 A, IEC

IEC 60947

OTDCP16SA11M OTDCP16S11M OTDCP16SA21M OTDCP16S21M OTDCP16SA22_ OTDCP16S22_


OTDCP25SA11M OTDCP25S11M OTDCP25SA21M OTDCP25S21M OTDCP25SA22_ OTDCP25S22_
OTDCP32SA11M OTDCP32S11M OTDCP32SA21M OTDCP32S21M OTDCP32SA22_ OTDCP32S22_
U e [V DC] 660 660 1000 1000 1000 / 2x660 1000 / 2x660
I e, DC-21B [A] 16 25 32 16 25 32 16 25 32 16 25 32 16 25 32 16 25 32

4 Product overview | Switches for PV applications


DC disconnect switches, front operated
16...600 A, UL* )

UL508i
File E4466875 Base or DIN-rail mounting
OTDC16U2 OTDC16U4 OTDC16U6 OTDC16US2 OTDC16US4 OTDC16US6
OTDC25U2 OTDC25U4 OTDC25US2 OTDC25US4
OTDC32U4 OTDC32US4
Rated Voltage [V DC] 600 600 600 600 600 600
Rated current [A] 16 25 16 25 32 16 16 25 16 25 32 16

UL508i
File E4466875 Door mounting
OTDC16UT2 OTDC16UT4 OTDC16UT6 OTDC16UST2 OTDC16UST4 OTDC16UST6
OTDC25UT2 OTDC25UT4 OTDC25UST2 OTDC25UST4
OTDC32UT4 OTDC32UST4
Rated Voltage [V DC] 600 600 600 600 600 600
Rated current [A] 16 25 16 25 32 16 16 25 16 25 32 16

UL98B
File #E354681
OTDC100U02 OTDC100U11 OTDC100U22 OTDC100US02 OTDC100US11 OTDC100US22
OTDC200U02 OTDC200U11 OTDC180U22 OTDC200US02 OTDC200US11 OTDC180US22
Rated Voltage [V DC] 1000 1000 1000 1000 1000 1000
Rated current [A] 100 200 100 200 100 180 100 200 100 200 100 180

UL98B
File #E354681
OTDC250U02 OTDC250U11 OTDC250U12 OTDC250U22 OTDC600UPP22
OTDC320U02 OTDC320U11 OTDC320U12 OTDC320U22
OTDC400U02 OTDC400U11 OTDC400U12 OTDC400U22
Rated Voltage [V DC] 1000 1000 1500 **)
1000 1000
Rated current [A] 250 320 400 250 320 400 250 320 400 250 320 400 600
*)
All UL listed products (except side operated) are also IEC rated up to 800 A
**)
UL98B self-certified at 1500 VDC while standard only goes up to 1000 VDC

Switches for PV applications | Product overview 5


DC disconnect switches, front operated
16...600 A, UL* )

UL98B
FIle #E354681
OTDC250US02 OTDC250US11 OTDC250US22 OTDC600USPP22
OTDC320US02 OTDC320US11 OTDC320US22
OTDC400US02 OTDC400US11 OTDC400US22
Rated Voltage [V DC] 1000 1000 1000 1000
Rated current [A] 250 320 400 250 320 400 250 320 400 600
*)
All UL listed products (except side operated) are also IEC rated up to 800 A

DC disconnect switches, side operated


100...400 A, UL

UL-types
UL98B
FIle #E354681

OTDC100U20S OTDC250U20S OTDC100US20S OTDC250US20S


OTDC200U20S OTDC320U20S OTDC200US20S OTDC320US20S
OTDC400U20S OTDC400US20S
Rated voltage [V DC] 1000 1000 1000 1000
Rated current [A] 100 200 250320400 100200 250320400

6 Product overview | Switches for PV applications


Switches for photovoltaic applications
Up to 1500 VDC

OTDC16...32 - Simply efficient OTDC100...800 - Switches for single and multi circuit
OTDC from 1632 Amperes have various DC voltage ratings disconnecting
within the same footprint area. Thanks to its modular design OTDC has been designed for DC applications and tested
the rated operational voltage can be scaled according to your beyond requirements.
needs, up to 1000 V. Reliable DC breaking power at all current levels

Reliable PV systems at a wide voltage range As a result of symmetric pole design, the connections are
independent of polarity. The user can make the connections
OTDC switch-disconnectors can be DIN rail or screw in both ways.
mounted. Tunnel terminals capture fine stranded wires and
they are wide enough to allow wires up to 16 mm 2. Short- Simplicity in installation
circuit bars are pre-installed as standard.
OTDC is the only DC switch in the market that has visible
Simple and fast installation contacts. The operation of the switch is not vulnerable to
voltage peaks and it is independent of the user (quick make-
OTDC1632 is also available in a plastic enclosure, suitable quick brake).
for outdoor use. Enclosed OTDCP is made of material
resistant to UV light and water exposure. The enclosure Safe and reliable operation
has a high degree of protection, IP65. Cover interlock and
padlockable handle ensure safe usage. Thanks to a modular design and the use of ABB's connection
kits, OTDC adapts to different installation requirements: single
OTDC1632 switches, with or without enclosure, meet the or multicircuit, 1500 VDC, side operation or combined outputs
standards thermal requirements, even in exceptionally high up to 1500 A.
operating ambient temperatures. The power losses are very
low, maximizing the efficiency. Superior flexibility

Suitable for warm locations


Maximum energy efficiency of PV systems

Switches for PV applications | Product overview 7


Technical data
OTDC16...800 and OTDCP16...32

Technical data according to IEC 60947 for switch-disconnectors OTDC16...250

Switch size OTDC16F OTDC25F OTDC32F OTDC16U OTDC25U OTDC32U OTDC100E OTDC160E OTDC200E OTDC250E
Rated insulation voltage Ui Pollution degree 2 V 1250 1)
1250 1) 12501) 1250 1) 1250 1) 1250 1)
Pollution degree 3 V 1000 1)
1000 1) 10001) 1000 1) 1000 1) 1000 1) 1000 1000 1000 1000
Dielectric strength 50 Hz 1 min kV 6 6 6 6 6 6
Rated impulse withstand
voltage kV 8 8 8 8 8 8 12 12 12 12
Rated thermal current Ith In open air, normal conditions 2) A 25 32 45 40 50 63 100 160 200 250
In enclosure 40C A 25 32 45 32 40 50 100 160 200 250
In enclosure 60C A 25 32 32 25 32 40 100 160 200 200
...with minimum cable or
bar cross section Cu mm 4 6 10 4 6 10 35 70 95 120
Rated operational current / 500 One circuit V 100 / 1 160 / 1 200 / 1 250 / 1
poles in series 660 One circuit V 16/2 25/2 32/2 16/2 25/2
DC-21B Two circuits V 25/2 25/2 32/2 16/2 25/2 32/2
1000 One circuit V 10/2 16/2 20/2 10/2 4) 16/2 4) 100 / 2 160 / 2 200 / 2 250 / 2
V 16/3 25/3 32/3
Two circuits V 10/2 16/2 20/2 10/2 4) 16/2 4) 20/2 4) 100 / 2 160 / 2 200 / 2 250 / 2
Three circuits V 10/2 4)
Rated short-time withstand
current, 1000 V, 1 s R.M.S. -value Icw kA 0,4 0,6 0,8 1,0 1,0 1,0 5 5 5 5
Rated short circuit making Peak value Icm kA 5 5 5 5
capacity, 1000 V Max. distance from switch frame to
nearest busbar / cable support mm 150 150 150 150
Rated conditional short-circuit Ip (r.m.s.), 1000 V kA 10 10 10
current Ip (r.m.s.) Max fuse size, gPV A 80 80 80
Power loss / pole At rated current W 0,15 0,3 0,5 0,1 0,2 0,35 2 4 6 9,5
Terminal cable size Cu mm 2.5...16 2.5...16 2.5...16 2.5...16 2.5...16 2.5...16
Terminal bolt size Metric thread diameter length mm M8x25 M8x25 M8x25 M8x25
Terminal tightening torque Counter torque required Nm 15-22 15-22 15-22 15-22
1)
When used with external handle. For use with direct mounted handle, see installation instruction.
2)
Normal conditions defined in IEC 60947-1-6.1
3)
1000 V with all the poles connected in series, 600 V with 2 poles in series
4)
U and UT types only. (Not applicable for US nor UST.)

8 Technical data | Switches for PV applications


Technical data according to IEC 60947 for switch-disconnectors OTDC315...800

Switch size OTDC315E OTDC400E OTDC500E OTDC630E OTDC800E


Rated insulation voltage U i Pollution degree 2 V 1500 1500 1500 1500 1500
Pollution degree 3 V 1500 1500 1500 1500 1500
Rated impulse withstand voltage kV 12 12 12 12 12
Rated thermal current I th In open air, normal conditions 5) A 315 400 630 630 800
In enclosure 40C A 315 400 550 630 800
In enclosure 60C A 315 400 440 630 680
...with minimum cable or bar cross section Cu mm 185 240 240 2x185 2x240
Rated operational current / poles in series 1000 One circuit V 315/2 400/2 500/2 630/2 800/2
Two circuits V 315/2 400/2 500/2
Three circuits V 315/2 400/2 500/2
1500 One circuit V 315/3 400/3 500/3
V 315/4 400/4 500/4
Two circuits V 315/3 400/3 500/3
Rated short-time withstand current, 1000 V, 1 s R.M.S. -value I cw kA 10 10 10 10 10
Rated short circuit making capacity, 1000 V Peak value I cm kA 10 10 10 10 10
Power loss / pole At rated current W 6 9,7 15,1 29,1 40
Terminal bolt size Metric thread diameter length mm M 10x30 M 10x30 M 12x40 M 12x40 M 12x40
Terminal tightening torque Counter torque required Nm 30-44 30-44 50-75 50-75 50-75
5)
Normal conditions defined in IEC 60947-1-6.1
6)
1000 V with all the poles connected in series, 600 V with 2 poles in series

Technical data according to IEC 60947 for enclosed switch-disconnectors OTDCP

Switch size A OTDCP16 OTDCP25 OTDCP32


Rated insulation voltage Pollution degree 2 V 1250 1250 1250
Pollution degree 3 V 1000 1000 1000
Dielectric strength 50 Hz 1 min kV 6 6 6
Rated impulse withstand voltage kV 8 8 8
Rated impulse withstand voltage In enclosure 40C A 25 32 45
DC-20 In enclosure 60C A 25 32 32
Rated operational current / poles in series 660 V A 16/2 25/2 32/2
DC-21B 1000 V A 16/3 25/3 32/3
2x660 V 9 ) A 16/4 25/4 32/4
Rated short-time withstand current, 1000 V, 1 s R.M.S. -value Icw kA 0.4 0.6 0.8
Power loss / pole At rated current W 0.15 0.3 0.5
9)
1000 V with all the poles connected in series, 600 V with 2 poles in series

Switches for PV applications | Technical data 9


Technical data
OTDC16...600

Technical data in accordance to UL508I for photovoltaic disconnect switches OTDC16...32U


Suitable For Use in Photovoltaic Systems in Accordance With Article 690 of the NEC.
Switch size OTDC16U OTDC25U OTDC32U
UL Listed Standard UL 508I UL 508I UL 508I
Rated ambient temperature C +60 +60 +60
Rated current /poles in series 600 V One circuit 16/2 25/2
Two circuits 16/2 25/2x2 32/2x2
Three circuits 16/2
Short circuit rating kA, 600 V 5 5 5
Protection type RK5 Fuse RK5 Fuse RK5 Fuse
Wire range MCM 12-6 AWG 12-6 AWG 12-6 AWG
Technical data according to IEC 60947 See IEC table for type OTDC16U OTDC25U OTDC32U

Technical data in accordance to UL98B for photovoltaic disconnect switches OTDC100...600U


Suitable For Use in Photovoltaic Systems in Accordance With Article 690 of the NEC.
Switch size OTDC100U OTDC200U OTDC250U OTDC320U OTDC400U OTDC600U
UL Listed Standard UL 98B UL 98B UL 98B UL 98B UL 98B UL 98B
Rated ambient temperature C -20...+50 -20...+50 -20...+50 -20...+50 -20...+50 -20...+50
Rated current /poles in series 1000 V One circuit 100/2 200/2 250/2 320/2 400/2 600/2
Two circuits 100/2 180/2 250/2 320/2 400/2
1500 V 7)
One circuit 250/3 320/3 400/3
Short circuit rating kA, 1000 V 5 5 10 10 10 10
Protection type Circuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker
Wire range MCM #4-300 #4-300 #2 600 #2 600 #2 600 #2 600
Technical data according to IEC 60947 See IEC table for type OTDC160E OTDC250E OTDC315E OTDC400E OTDC500E OTDC630E
7)
For 4 pole switches (double circuit use), the current rating at 1000 VDC is 180 A.
8)
1500 V ratings are not within the scope of UL98B. 1500 V values are self-certified and tested at 1500 V, based on corresponding 1000 V UL98B guidelines.

10 Technical data | Switches for PV applications


Type designation key

OTDC16...32, IEC
OTDC 16 F 3
1 2 3 4

1 Brand UT Door mounted, UL


OTDC ABB DC switch-disconnector brand UST Door mounted, UL, factory mounted jumpers
2 Switch size FT Door mounted, IEC
1632 16, 25 and 32 Amperes 4 Number of poles
3 Mounting/construction 2 Two poles
F_ Base mounted, IEC 3 Three poles
U_ Base mounted, UL508i 4 Four poles
US_ Base mounted, UL, factory mounted jumpers 6 Six poles

OTDC100...800, IEC and UL98B


OTDC 200 U S 11 K
1 2 3 4 5 6

1 Brand 5 Number of poles


OTDC ABB DC switch-disconnector brand 11 Two poles, mechanism between the poles
2 Switch size 02, 20 Two poles, mechanism at the end of the switch
100800 100800 Amperes 12 Three poles, mechanism between the poles
3 Voltage and standard 22 Four poles, mechanism between the poles
E 1000 VDC, IEC 04, 40 Four poles, mechanism at the end of the switch
U 1000 VDC, UL98B 33 Six poles, mechanism between the poles
4 Short circuit links 6 Included handle
blank Short circuit links not included _ none
V Factory mounted short circuit link, 1500 VDC P external handle
S Pre-mounted short circuit links, single wire breaking K direct mount, front operation
PP Pre-mounted connection bars, supply and load side parallel S direct mount, side operation

OTDCP16...32, IEC
OTDC P 16 S 11 M D
1 2 3 4 5 6 7

1 Brand 6 Cable entries


OTDC ABB DC switch-disconnector brand M Threaded knock-out M20
2 Enclosure material M16 Threaded knock-out M16
P Plastic U Blank cable entries
3 Switch size UM Black top cable entry and threaded knockout M20 bottom cable entry
1632 16, 25 and 32 Amperes M16 Threaded knockouts: M16 top cable entry and M20 bottom cable entry
4 Selector handle color 7 Connection options
S Black _ Single circuit use
SA Red-yellow D Double circuit use
5 Contact configuration
11, 12, 22 See connection diagrams in pages 16-17

Switches for PV applications | Technical data 11


OTDC1632 ordering information
Front operated switch-disconnectors, IEC

OTDC16...32F2 Switch-disconnectors OTDC_, base or DIN-rail mounting, IEC


Types OTDC16...32 include IP20 protected terminal clamps. Shafts and handles need to be
ordered separetely, see pages 33-34. Short circuit links included in the package.

Single circuit use


Up to 660 VDC
OTDC16...32F3 Number Rated operat. current Weight/
of [A] unit
poles DC 21B / 660 V Type Order number [kg]
2 16 OTDC16F2 1SCA121454R1001 0.15
2 25 OTDC25F2 1SCA121455R1001 0.15
2 32 OTDC32F2 1SCA121456R1001 0.15

OTDC16...32F4 Up to 1000 VDC


Number Rated operat. current Weight/
of [A] unit
poles DC 21B / 1000 V Type Order number [kg]
2 10 OTDC16F2 1SCA121454R1001 0.20
2 16 OTDC25F2 1SCA121455R1001 0.20
2 20 OTDC32F2 1SCA121456R1001 0.20
- + 3 16 OTDC16F3 1SCA121457R1001 0.20
OTDC_F2
1 3 3 25 OTDC25F3 1SCA121458R1001 0.20
- +
3 32 OTDC32F3 1SCA121459R1001 0.20
1 - 3+
1 3 Double circuit use
2 4
+ Up to 1000 VDC
-
2 4 Number Rated operat. current
- 2+ 4 of [A] Weight/
- + poles DC 21B / DC 21B / unit
-
OTDC_F3
OEZXY85 660 V 1000 V Type Order number [kg]
2x2 16 10 OTDC16F4 1SCA121461R1001 0.25
1 3 5
- OEZXY85 2x2 25 16 OTDC25F4 1SCA121462R1001 0.25
1 - 3OEZXY85
5 2x2 32 20 OTDC32F4 1SCA121463R1001 0.25

2 4 1 6 3 5
- + +
2 4 6
- 2+ 4+ 6
OTDC_F4 - + +

- OEZXY85 +
1 - 3 OEZXY85
5 7 +

1 - 3 OEZXY85
5 7 +

2 4 1 6 3 8 5 7
- + OEZXY86
2 4 6 8
- 2+ 4 6
OEZXY86 8
- + OEZXY86

12 Ordering information | Switches for PV applications


OTDC1632 ordering information
Front operated switch-disconnectors, UL

OTDC16U2, OTDC16US2 Switch-disconnectors OTDC_, base or DIN-rail mounting, UL


Touch-safe IP20 protected terminal clamps included. Types OTDC1632US include pre-
mounted short circuit link OEZXY86. Shafts and handles to be ordered separately.

Single circuit
Number Rated operat. current [A] Weight/
OTDC16U4, OTDC16US4 of UL IEC unit
poles 600 VDC 660 VDC 1000 VDC Type Order number [kg]
2 16 16 10 OTDC16U2 1SCA134369R1001 0.15
2 25 25 16 OTDC25U2 1SCA134375R1001 0.15
2 16 16 - OTDC16US2 1SCA134372R1001 0.15
2 25 25 - OTDC25US2 1SCA134378R1001 0.15

OTDC16U6, OTDC16US6
Double circuit
Number Rated operat. current [A] Weight/
of UL IEC unit
poles 600 VDC 660 VDC 1000 VDC Type Order number [kg]
4 16 16 10 OTDC16U4 1SCA134370R1001 0.15
4 25 25 16 OTDC25U4 1SCA134377R1001 0.15
4 32 32 20 OTDC32U4 1SCA136703R1001 0.15
4 16 16 - OTDC16US4 1SCA134373R1001 0.15
OTDC_US2 OTDC_US4 4 25 25 - OTDC25US4 1SCA134379R1001 0.15
4 32 32 - OTDC32US4 1SCA136704R1001 0.15
Inverter 2
Panel 2

+ +
(-) (-)
OEZXY86 OEZXY86
1 3 1 3 5 7 Triple circuit
2 4 2 4 6 8 Number Rated operat. current [A] Weight/
+ OEZXY86
Inverter 1
Panel 1

+
Inverter 1
Panel 1

+ +
(-) (-) of UL IEC unit
(-) (-)
poles 600 VDC 660 VDC 1000 VDC Type Order number [kg]
OTDC_US6 6 16 16 10 OTDC16U6 1SCA134371R1001 0.15
6 16 16 - OTDC16US6 1SCA134374R1001 0.15
Inverter 2
Panel 2

+ +
(-) (-)
OEZXY86 OEZXY86
1 3 5 7 9 11

2 4 6 8 10 12
+ + OEZXY86 + +
Inverter 1
Panel 1

Inverter 3
Panel 3

(-) (-) (-) (-)

OTDC_U2 OTDC_U4
Inverter 1

Inverter 1

Inverter 1

Inverter 1

Inverter 2

Inverter 2

+ -
(-) (+) + - + -
(-) (+) (-) (+)

1 3 1 3 5 7

2 4 2 4 6 8
+ - + - + -
Panel 1

Panel 1

Panel 1

Panel 1

Panel 2

Panel 2

(-) (+) (-) (+) (-) (+)

OTDC_U6
Inverter 1

Inverter 1

Inverter 2

Inverter 2

Inverter 3

Inverter 3

+ - + - + -
(-) (+) (-) (+) (-) (+)

1 3 5 7 9 11

2 4 6 8 10 12
+ - + - + -
Panel 1

Panel 1

Panel 2

Panel 2

Panel 3

Panel 3

(-) (+) (-) (+) (-) (+)

Switches for PV applications | Ordering information 13


OTDC1632 ordering information
Front operated switch-disconnectors, IEC

OTDC16...32FT2 Switch-disconnectors OTDC_, door mounting, IEC


Types OTDC16...32 include IP20 protected terminal clamps. Shafts and handles need to be
ordered separetely, see pages 33-34. Short circuit links included in the package.

Single circuit use


Up to 660 VDC
OTDC16...32FT3 Number Rated operat. current Weight/
of [A] unit
poles DC 21B / 660 V Type Order number [kg]
2 16 OTDC16FT2 1SCA123839R1001 0.15
2 25 OTDC25FT2 1SCA123842R1001 0.15
2 32 OTDC32FT2 1SCA123845R1001 0.15

OTDC16...32FT4 Up to 1000 VDC


Number Rated operat. current Weight/
of [A] unit
poles DC 21B / 1000 V Type Order number [kg]
2 10 OTDC16FT2 1SCA123839R1001 0.20
2 16 OTDC25FT2 1SCA123842R1001 0.20
2 20 OTDC25FT2 1SCA123845R1001 0.20
- + 3 16 OTDC16FT3 1SCA123840R1001 0.20

1 - 3 +
OTDC_FT2 3 25 OTDC25FT3 1SCA123843R1001 0.20

1 - 3+ 3 32 OTDC32FT3 1SCA123846R1001 0.20

1 3
Double circuit use
2 4
Up to 1000 VDC
- +
2 4
Number Rated operat. current
- 2+ 4
of [A] Weight/
- +
poles DC 21B / DC 21B / unit
OTDC_FT3
- OEZXY85
660 V 1000 V Type Order number [kg]

- 3 OEZXY85 2x2 16 10 OTDC16FT4 1SCA123841R1001 0.25


1 5
2x2 25 16 OTDC25FT4 1SCA123844R1001 0.25
1 - 3OEZXY85
5
2x2 32 20 OTDC32FT4 1SCA123847R1001 0.25
1 3 5
2 4 6
- +2 +4 6
- +
2 4+ 6
- + +
OTDC_FT4

- OEZXY85 +
1 - 3 OEZXY85
5 7 +
1 - 3 OEZXY85
5 7 +
1 3 5 7
2 4 6 8
- +2 4 6
OEZXY86 8
- 2+ 4OEZXY86
6 8
- + OEZXY86

14 Ordering information | Switches for PV applications


OTDC1632 ordering information
Front operated switch-disconnectors, UL

OTDC16UT2, OTDC16UST2 Switch-disconnectors OTDC1632U_T, door mounting


Touch-safe IP20 protected terminal clamps included. Types OTDC1632US include pre-
mounted short circuit link OEZXY86. Shafts and handles to be ordered separately.

Single circuit - up to 1000 VDC


Number Rated operat. current [A] Weight/
OTDC16UT4, OTDC16UST4 of UL IEC unit
poles 600 VDC 660 VDC 1000 VDC Type Order number [kg]
2 16 16 10 OTDC16UT2 1SCA134387R1001 0.15
2 25 25 16 OTDC25UT2 1SCA134388R1001 0.15
2 16 16 - OTDC16UST2 1SCA134581R1001 0.15
2 25 25 - OTDC25UST2 1SCA134578R1001 0.15

OTDC16UT6, OTDC16UST6 Double circuit - up to 1000 VDC


Number Rated operat. current [A] Weight/
of UL IEC unit
poles 600 VDC 660 VDC 1000 VDC Type Order number [kg]
4 16 16 10 OTDC16UT4 1SCA134390R1001 0.15
4 25 25 16 OTDC25UT4 1SCA134391R1001 0.15
4 32 32 20 OTDC32UT4 1SCA136705R1001 0.15
4 16 16 - OTDC16UST4 1SCA134582R1001 0.15
OTDC_UST2 OTDC_UST4 4 25 25 - OTDC25UST4 1SCA134579R1001 0.15
4 32 32 - OTDC32UST4 1SCA136706R1001 0.15
Inverter 2
Panel 2

+ +
(-) (-)
OEZXY86 OEZXY86
1 3 1 3 5 7
Triple circuit - up to 1000 VDC
2 4 2 4 6 8 Number Rated operat. current [A] Weight/
+ OEZXY86
Inverter 1
Panel 1

+
Inverter 1
Panel 1

+ +
(-) (-) of UL IEC unit
(-) (-)
poles 600 VDC 660 VDC 1000 VDC Type Order number [kg]
OTDC_UST6 6 16 16 10 OTDC16UT6 1SCA134580R1001 0.15
6 16 16 - OTDC16UST6 1SCA134583R1001 0.15
Inverter 2
Panel 2

+ +
(-) (-)
OEZXY86 OEZXY86
1 3 5 7 9 11

2 4 6 8 10 12
+ + OEZXY86 + +
Inverter 1
Panel 1

Inverter 3
Panel 3

(-) (-) (-) (-)

OTDC_UT2 OTDC_UT4
Inverter 1

Inverter 1

Inverter 1

Inverter 1

Inverter 2

Inverter 2

+ -
(-) (+) + - + -
(-) (+) (-) (+)

1 3 1 3 5 7

2 4 2 4 6 8
+ - + - + -
Panel 1

Panel 1

Panel 1

Panel 1

Panel 2

Panel 2

(-) (+) (-) (+) (-) (+)

OTDC_UT6
Inverter 1

Inverter 1

Inverter 2

Inverter 2

Inverter 3

Inverter 3

+ - + - + -
(-) (+) (-) (+) (-) (+)

1 3 5 7 9 11

2 4 6 8 10 12
+ - + - + -
Panel 1

Panel 1

Panel 2

Panel 2

Panel 3

Panel 3

(-) (+) (-) (+) (-) (+)

Switches for PV applications | Ordering information 15


OTDCP1632 ordering information
Enclosed switch-disconnectors, IEC

OTDCP_SA_ Plastic enclosed switch-disconnectors OTDCP_, IEC


M20 threaded knock-outs, compression glands have to be ordered separately.
M16 threaded knock-outs available on request.

Up to 660 VDC
Number Rated operat. current [A] Weight/
of DC 21B / unit
poles 660 V Type Order number [kg]
OTDCP_S_ Includes red-yellow selector handle (I-0 and ON-OFF indication)
2 16 OTDCP16SA11M 1SCA125126R1001 0.55
2 25 OTDCP25SA11M 1SCA125127R1001 0.55
2 32 OTDCP32SA11M 1SCA125128R1001 0.55
Includes black selector handle (I-0 and ON-OFF indication)
2 16 OTDCP16S11M 1SCA125129R1001 0.55
2 25 OTDCP25S11M 1SCA125130R1001 0.55
2 32 OTDCP32S11M 1SCA125131R1001 0.55

Up to 1000 VDC
OTDCP_11_ Number Rated operat. current [A] Weight/
OTDCP_11_
OTDCP_11_ of DC 21B / unit
OTDCP_11_ - +
poles 1000 V Type Order number [kg]
- +
-1 +3
Includes red-yellow selector handle (I-0 and ON-OFF indication)
1 3
1 3 3 16 OTDCP16SA12M 1SCA125150R1001 0.55
3 25 OTDCP25SA12M 1SCA125151R1001 0.55
2 4
3 32 OTDCP32SA12M 1SCA125152R1001 0.55
22 4 4 Includes black selector handle (I-0 and ON-OFF indication)
Load
3 16 OTDCP16S12M 1SCA125153R1001 0.59
Load
Load 3 25 OTDCP25S12M 1SCA125154R1001 0.59
3 32 OTDCP32S12M 1SCA125155R1001 0.59
OTDCP_12_
OTDCP_12_
OTDCP_12_
OTDCP_12_ Up to 1000 VDC or 2x660 VDC1)
-
-- Number Rated operat. current [A] Weight/
1 3 5
11 3 3 5 5 of DC 21B / unit
poles 1000 V Type Order number [kg]
Includes red-yellow selector handle (I-0 and ON-OFF indication)
2 4 6
22 4 4 6 6 4 16 OTDCP16SA22M 1SCA125094R1001 0.63
+
4 25 OTDCP25SA22M 1SCA125091R1001 0.63
Load + +
Load 4 32 OTDCP32SA22M 1SCA125090R1001 0.63
Load
Includes black selector handle (I-0 and ON-OFF indication)
4 16 OTDCP16S22M 1SCA125095R1001 0.63
OTDCP_22_
OTDCP_22_
OTDCP_22_ 4 25 OTDCP25S22M 1SCA125092R1001 0.63
OTDCP_22_
- 4 32 OTDCP32S22M 1SCA125093R1001 0.63
-
-
1 3 5 7
1 3 5 7
1 3 5 7

22 4 66 88
4
2+ 4 6 8
+
+ Load
Load
Load

16 Ordering information | Switches for PV applications


OTDCP1632 ordering information
Enclosed switch-disconnectors, IEC

OTDCCP22_22_MD Double circuit


Number Rated operat. current [A] Weight/
of DC 21B / DC 21B / unit
- + - +
poles 660 V 1000 V Type Order number [kg]
1 3 5 7
Includes red-yellow selector handle (I-0 and ON-OFF indication)
ON
OFF 4 16 10 OTDCP16SA22MD 1SCA131850R1001 0.63
4 25 16 OTDCP25SA22MD 1SCA131851R1001 0.63
2 4 6 8 4 32 20 OTDCP32SA22MD 1SCA131852R1001 0.63
- + - +
Includes black selector handle (I-0 and ON-OFF indication)
4 16 10 OTDCP16S22MD 1SCA131730R1001 0.63
4 25 16 OTDCP25S22MD 1SCA131731R1001 0.63
4 32 20 OTDCP32S22MD 1SCA131732R1001 0.63

Switches for PV applications | Ordering information 17


OTDC100800 ordering information
Front operated switch-disconnectors, IEC

OTDC100...250E02 Single circuit, 1000 VDC, IEC - 100 to 800 A


Shafts and handles are not included. Switches with external handle (OTDC_P, e.g. OTDC200E02P)
or direct mount handle (OTDC_K, e.g.OTDC400E02K) are available. Phase barriers included if
mandatory. Included terminal bolts:
- OTDC100...250: M8x25
- OTD315...400: M10x30
OTDC100...250E11 - OTDC500...800: M12x40

Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles DC 21B / 1000 V Type Order number [kg] Direct mount (K) External (P) + shaft
Front operated, mechanism at the end of the switch.
2 100 OTDC100E02 1SCA125822R1001 1.1 OTDV250EK OHB65J6
OTDC315...500E02 2 160 OTDC160E02 1SCA125840R1001 1.1 + shaft OXP6x210
2 200 OTDC200E02 1SCA123687R1001 1.1
2 250 OTDC250E02 1SCA125866R1001 1.1
2 315 OTDC315E02 1SCA132337R1001 4.3 OTDV400EK OHB95J12
2 400 OTDC400E02 1SCA132349R1001 4.3 + shaft OXP12x185
2 500 OTDC500E02 1SCA132357R1001 4.3
Front operated, mechanism between the poles. OTDC_EPP types inlcude pre-mounted connection bars.
2 100 OTDC100E11 1SCA125821R1001 1.1 OTDV250EK OHB65J6
OTDC315...500E11 2 160 OTDC160E11 1SCA123745R1001 1.1 + shaft OXP6X210
2 200 OTDC200E11 1SCA125626R1001 1.1
2 250 OTDC250E11 1SCA125865R1001 1.1
2 315 OTDC315E11 1SCA130982R1001 4.3 OTDV400EK OHB95J12
2 400 OTDC400E11 1SCA130983R1001 4.3 + shaft OXP12x185
2 500 OTDC500E11 1SCA132135R1001 4.3
2 630 OTDC630EPP22 1SCA137205R1001 7 OTDV400EK OHB95J12
+ shaft OXP12x185
OTDC630..800EPP22 2 800 OTDC800EPP22 1SCA137210R1001 7

Connection kits and shrouds


See pages 20-21 for circuit diagrams, connection kits and link shrouds. The column "Needed
quantity" tells how many pieces need to be ordered for each switch. The kits include the
needed short circuit links, screws and washers.

Connection kit/ Recommended


short circuit link shroud
Circuit Needed Needed
Switches type Type Quantity Type quantity
OTDC100500E02, 2a, 2b - - - -
OTDC100500E11
OTDC630...800EPP22*) 6c - - OTDCS400T2L 4
*)
Connection bars are premounted for all OTDC_EPP types

18 Ordering information | Switches for PV applications


OTDC100800 ordering information
Front operated disconnect switches, UL

OTDC100...200US02 Single circuit, 1000 VDC, UL98B - 100 to 600 A


Shafts and handles are not included. Switches with direct mount handle (OTDC_K, e.g.
OTDC400E02K) are available. Phase barriers are included if mandatory. Included terminal bolts:
- OTDC100...200: M8x25
- OTD250...320: M10x30
- OTDC400...600: M12x40
OTDC250...400US11
Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles UL98B / 1000 V Type Order number [kg] Direct mount (K)
Front operated, mechanism at the end of the switch. OTDC_US types inlcude pre-mounted short circuit link.
2 100 OTDC100US02 1SCA126155R1001 1.2 OTDV250EK
2 200 OTDC200US02 1SCA126121R1001 1.2
2 100 OTDC100U02 1SCA126184R1001 1.1
OTDC250...400U11 2 200 OTDC200U02 1SCA126123R1001 1.1
2 250 OTDC250US02 1SCA132335R1001 4.4 OTDV400EK
2 320 OTDC320US02 1SCA132345R1001 4.4
2 400 OTDC400US02 1SCA132354R1001 4.4
2 250 OTDC250U02 1SCA132330R1001 3.8 OTDV400EK
2 320 OTDC320U02 1SCA132341R1001 3.8
2 400 OTDC400U02 1SCA132352R1001 3.8
Front operated, mechanism between the poles. OTDC_US and OTDC_U_PP types inlcude pre-mounted short circuit links/bars.
OTDC600USPP22 2 100 OTDC100US11 1SCA125437R1001 1.2 OTDV250EK
2 200 OTDC200US11 1SCA125436R1001 1.2
2 100 OTDC100U11 1SCA123957R1001 1.1
2 200 OTDC200U11 1SCA123767R1001 1.1
2 250 OTDC250US11 1SCA131012R1001 4.4 OTDV400EK
2 320 OTDC320US11 1SCA131013R1001 4.4
2 400 OTDC400US11 1SCA131014R1001 4.4
2 250 OTDC250U11 1SCA130985R1001 3.8
2 320 OTDC320U11 1SCA130986R1001 3.8
OTDC600UPP22 2 400 OTDC400U11 1SCA130990R1001 3.8
2 600 OTDC600USPP22 1SCA137213R1001 7.9 OTDV400EK
2 600 OTDC600UPP22 1SCA137207R1001 7

Switches for PV applications | Ordering information 19


OTDCKIT400S101 Connection kits and shrouds
Pre-mounted short circuit links/connection bars are included for all OTDC_US and OTDC_UPP
types. Shrouds must be ordered separately. See pages 20-21 for circuit diagrams, connection
kits and shrouds. The column "Needed quantity" tells how many pieces need to be ordered for
each switch. The kits include the needed short circuit links/bars, screws and washers.

Connection kit/ Recommended


short circuit link shroud

Circuit Needed Needed


Switches type Type quantity Type quantity
OTDC100200US11, OTDC100200US02 1a, 1b - - OEZXY92 1
OTDC100200U11, OTDC100200U02 2a, 2b - - - -
OTDC250400US11, OTDC250400US02 1a, 1b - - OEZXY97 1
OTDC250400U11, OTDC250400U02 1a, 1b OTDCKIT400S101 1 OEZXY97 1
OTDC250400U11, OTDC250400U02 2a, 2b - - - -
OTDC600UPP22 6c - - OTDCS400T2L 4
OTDC600USPP22 6e - - OTDCS400T2L 2
6e - - OTDCS2504GB 1

Circuit 1a, 1b, 1000 VDC


OTDCKIT400S101 / OEZX91

+(-) +(-) +(-) +(-)

OEZXY_
OTDCB_/_*)

Circuit 1a, 1b Circuit 1a


Accessories for OTDC315...500E,OTDC250...400U Accessories for OTDC100...250E
Order Needed Order Needed
Description Type number quantity Description Type number quantity
Needed short circuit link -KIT OTDCKIT400S101 1SCA136280R1001 1 Needed short circuit link -KIT OEZXY91 1SCA125290R1001 1
Recommended shroud OEZXY97 1SCA130816R1001 1 Recommended shroud OEZXY92 1SCA127382R1001 1

Circuit 2a, 2b, 1000 VDC

+(-) -(+) +(-) -(+)

+(-) -(+) +(-) -(+)

OTDCB_/_*)

*)
OTDCB_/_ phase barrier(s) included if mandatory

20 Ordering information | Switches for PV applications


Circuit 6c, 6g, 1000 VDC

+(-) -(+)

OTDCS400T2L

+(-) -(+)

Circuit 6c, 6g
Accessories for OTDC630...800EPP, OTDC600UPP
Order Needed
Description Type number quantity
Needed short circuit link -KIT - - -
Recommended shroud OTDCS400T2L 1SCA136275R1001 4

Circuit 6e, 1000 VDC


OTDCS400G4B

+(-) +(-)

OTDCS400T2L

Circuit 6e
Accessories for OTDC600USPP
Order Needed Order Needed
Description Type number quantity Type number quantity
Needed short circuit link -KIT - - - - - -
Recommended shroud OTDCS400T2L 1SCA136275R1001 2 OTDCS250G4B 1SCA136274R1001 1

Switches for PV applications | Ordering information 21


OTDC100800 ordering information
Front operated switch-disconnectors, IEC

OTDC100...250E22 Double circuit and load side combining, 1000 VDC,


IEC - 100...500 A
The switches OTDC_E22 can be used for double circuit applications or to create a combined
output up to 1000 A. Shafts and handles are not included. Switches with external handle
(OTDC_P, e.g. OTDC200E22P) or direct mount handle (OTDC_K, e.g. OTDC400E22K) are
OTDC315...500E22 available. Phase barriers included if mandatory. Included terminal bolts:
- OTDC100...250: M8x25
- OTD315...400: M10x30
- OTDC500: M12x40

Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles DC 21B / 1000 V Type Order number [kg] Direct mount (K) External (P) + shaft
Mechanism between the poles
2x2 100 OTDC100E22 1SCA125824R1001 1.9 OTDV250EK OHB65J6
2x2 160 OTDC160E22 1SCA125844R1001 1.9 + shaft OXP6x210
2x2 200 OTDC200E22 1SCA125856R1001 1.9
2x2 250 OTDC250E22 1SCA125869R1001 1.9
2x2 315 OTDC315E22 1SCA131001R1001 6.6 OTDV400EK OHB95J12
2x2 400 OTDC400E22 1SCA131036R1001 6.6 + shaft OXP12x185
2x2 500 OTDC500E22 1SCA132142R1001 7

OTDCKIT400B11 Connection kits and shrouds


See pages 24-25 for circuit diagrams, connection kits and shrouds. The column "Needed
quantity" tells how many pieces need to be ordered for each switch. The kits include the
needed short circuit links/bars, screws and washers.

Connection kit/ Recommended


short circuit link shroud

Circuit Needed Needed


Switches type Type Quantity Type Quantity
OTDC100500E22 4a, 4c - - - -
OTDC315...500E22 6d OTDCKIT400B11 2 OTDCS400T2L 2

22 Ordering information | Switches for PV applications


OTDC100800 ordering information
Front operated disconnect switches, UL

OTDC100...180US22 Double circuit and load side combining, 1000 VDC,


UL98B -100...400 A
The switches OTDC_U22 and OTDCUS22 can be used for double circuit applications or to
create a combined output up to 800 A. Shafts and handles are not included. Switches with
direct mount handle (OTDC_K, e.g. OTDC400U22K) are available. Phase barriers are included
if mandatory. Included terminal bolts:
OTDC100...200U22 - OTDC100...200: M8x25
- OTD250...320: M10x30
- OTDC400: M12x40

Number Rated operat. Delivery Weight/ Recommended
of current [A] batch unit handle
poles UL98B / 1000 V Type Order number [pcs] [kg] Direct mount (K)
OTDC250...400US22 Mechanism between the poles. OTDC_US types inlcude pre-mounted short circuit links.
2X2 100 OTDC100US22 1SCA126181R1001 1 2.5 OTDV250EK
2X2 180 OTDC180US22 1SCA126942R1001 1 2.5
2X2 100 OTDC100U22 1SCA126180R1001 1 2.3 OTDV250EK
2X2 180 OTDC180U22 1SCA126941R1001 1 2.3
2X2 250 OTDC250US22 1SCA131030R1001 1 6.6 OTDV400EK
2X2 320 OTDC320US22 1SCA131032R1001 1 6.6
2X2 400 OTDC400US22 1SCA132300R1001 1 6.6
OTDC250...400U22 2X2 250 OTDC250U22 1SCA131003R1001 1 6.6 OTDV400EK
2X2 320 OTDC320U22 1SCA131006R1001 1 6.6
2X2 400 OTDC400U22 1SCA131010R1001 1 6.6

Connection kits and shrouds


Pre-mounted short circuit links/connection bars are included for all OTDC_US types. Shrouds
OTDCKIT400S11 must be ordered separately. See pages 24-25 for circuit diagrams, connection kits and
shrouds. The column "Needed quantity" tells how many pieces need to be ordered for each
switch. The kits include the needed short circuit links/bars, screws and washers.

Connection kit/ Recommended


OTDCKIT400B11 short circuit link shroud
Circuit Needed Needed
Switches type Type quantity Type quantity
OTDC100180US22*) 3 OEZXY91 2 OEZXY92 2
OTDC250400US22 *), 3 OTDCKIT400S11 2 OTDCS400G2B 2
OTDC250400U22
OTDC100...180U22, 4a - - - -
OTDC250...400U22
OTDC250...400U22 6d OTDCKIT400B11 2 OTDCS400T2L 2
OTDC250...400US22*) 6f OTDCKIT400B101 1 OTDCS400G2B 2
OTDC400T11L 1
*)
Short circuit links are premounted, for circuit 6f OTDCKIT400B101 must be ordered separately

Switches for PV applications | Ordering information 23


Circuit 3, 1000 VDC - Double circuit
OTDCKIT400S11

+(-) +(-) +(-) +(-) OTDCS400G2B


1 1 2 2
OTDCB_/_*)

Circuit 3 Circuit 3
Accessories for OTDC315...500E, OTDC250...400U Accessories for OTDC100...250E
Order Needed Order Needed
Description Type number quantity Description Type number quantity
Needed short circuit link -KIT OTDCKIT400S11 1SCA136281R1001 2 Needed short circuit link -KIT OEZXY91 1SCA125290R1001 2
Recommended shroud OTDCS400G2B 1SCA136273R1001 2 Recommended shroud OEZXY92 1SCA127382R1001 2

Circuit 4a, 4c, 1000 VDC - Double circuit

+(-) -(+) +(-) -(+)

+(-) -(+) +(-) -(+)


1 1 2 2
OTDCB_/_*)

Circuit 6d, 1000 VDC - Load side combining


LOAD OTDCS400T2L OTDCKIT400B11
1+2 1+2
+(-) -(+)

+(-) +(-) -(+) -(+)


1 2 1 2

OTDCB_/_*)

Circuit 6d
Accessories for OTDC315...500E, OTDC250...400U
Order Needed
Description Type number quantity
Needed connection bar kit OTDCKIT400B11 1SCA136282R1001 2
Recommended shroud OTDCS400T2L 1SCA136275R1001 2

*)
OTDCB_/_ phase barrier(s) included if mandatory

24 Ordering information | Switches for PV applications


Circuit 6f, 1000 VDC - Load side combining
OTDCS400G2B

+(-) +(-) +(-)


1 1+2 2
LOAD
OTDCB_/_*)
OTDCKIT400B101

OTDC400T11L

Circuit 6f
Accessories for OTDC250...400US
Order Needed Order Needed
Description Type number quantity Type number quantity
Needed connection bar kit OTDCKIT400B101 1SCA136283R1001 1 - - -
Recommended shroud OTDCS400G2B 1SCA136273R1001 2 OTDCS400T11L 1SCA136279R1001 1

*)
OTDCB_/_ phase barrier(s) included if mandatory

Switches for PV applications | Ordering information 25


OTDC100800 ordering information
Front operated switch-disconnectors, IEC

OTDC315...500E33 Triple circuit and load side combining, up to 1000 VDC,


IEC - 315...500 A
The switches OTDC_E33 can be used for triple circuit applications or to create a combined
output up to 1500 A. Shafts and handles are not included. Switches with external handle
(OTDC_P, e.g. OTDC400E33P) or direct mount handle (OTDC_K, e.g. OTDC400E33K) are
available. Terminal bolts M12x40 included. Phase barriers included if mandatory.

Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles DC 21B / 1000 V Type Order number [kg] Direct mount (K) External (P) + shaft
Mechanism between the poles, single circuit
2x3 315 OTDC315E33 1SCA137230R1001 6.6 OTDV400EK2 OHB145J12
2x3 400 OTDC400E33 1SCA137231R1001 6.6 + shaft OXP12x185
2x3 500 OTDC500E33 1SCA137234R1001 6.6

OTDCKIT400B111 Connection kits and shrouds


See page 27 for circuit diagrams, connection kits and shrouds. The column "Needed quantity"
tells how many pieces need to be ordered for each switch. The kits include the needed bars,
screws and washers.

Connection kit/ Recommended


short circuit link shroud
Needed Needed
Switches Circuit type Type Quantity Type Quantity
OTDC315500E33 7a, 7e - - - -
7d OTDCKIT400B111 2 OTDCS400T3L 2

26 Ordering information | Switches for PV applications


Circuit 7a,7e, 1000 VDC

+(-) -(+) +(-) -(+) +(-) -(+)

+(-) -(+) +(-) -(+) +(-) -(+)


1 1 2 2 3 3
OTDCB_/_*)

Circuit 7d, 1000 VDC


1+2+3 LOAD 1+2+3
+(-) -(+)
OTDCS400T3L

OTDCKIT400B111

+(-) +(-) +(-) -(+) -(+) -(+)


1 2 3 1 2 3

OTDCB_/_*)

Circuit 7d
Accessories for OTDC315...500E
Order Needed
Description Type number quantity
Needed short circuit link -KIT OTDCKIT400B111 1SCA136284R1001 2
Recommended shroud OTDCS400T3L 1SCA136276R1001 2

*)
OTDCB_/_ phase barrier(s) included if mandatory

Switches for PV applications | Ordering information 27


OTDC100800 ordering information
Front operated switch-disconnectors, IEC

OTDC315...500EV12 Single and double circuit, 1500 VDC, IEC - 315...500 A


Shafts and handles are not included. Switches with external handle (OTDC_P, e.g. OTDC200EV12P)
or direct mount handle (OTDC_K, e.g. OTDC400EV12K) are available. Phase barriers included if
mandatory. Included terminal bolts:
- OTD315...400: M10x30
- OTDC500: M12x40

OTDC315...500E33 Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles DC 21B / 1500 V Type Order number [kg] Direct mount (K) External (P)+ shaft
Mechanism between the poles, single circuit. Pre-mounted short circuit link.
3 315 OTDC315EV12 1SCA132258R1001 5.1 OTDV400EK OHB95J12
3 400 OTDC400EV12 1SCA132256R1001 5.1 + shaft OXP12x185
3 500 OTDC500EV12 1SCA132257R1001 5.1
Mechanism between the poles, double circuit.
2x3 315 OTDC315E33 1SCA137230R1001 6.6 OTDV400EK2 OHB145J12
2x3 400 OTDC400E33 1SCA137231R1001 6.6 + shaft OXP12x185
2x3 500 OTDC500E33 1SCA137234R1001 6.6

OTDCKIT400S101 Connection kits and shrouds


Pre-mounted short circuit links/connection bars are included for OTDC_EV types. Shrouds
must be ordered separately. See pages 30-31 for circuit diagrams, connection kits and
shrouds. The column "Needed quantity" tells how many pieces need to be ordered for each
OTDCKIT400S11 switch. The kits include the needed short circuit links/bars, screws and washers.

Connection kit/ Recommended


short circuit link shroud
Circuit Needed Needed
Switches type Type quantity Type quantity
OTDC315400EV12, 5a, 5b OTDCKIT400S101 1 OEZXY97 1
OTDC315400E12
OTDC315400E33 7b, 7g OTDCKIT400S11 2 OTDCS400G2B 2

28 Ordering information | Switches for PV applications


OTDC100800 ordering information
Front operated disconnect switches, UL

OTDC250...400U12 Single circuit, 1500 VDC, UL 98B *) - 250...400 A


Shafts and handles are not included. Switches with direct mount handle (OTDC_K, e.g.
OTDC250U12K) are available. Phase barriers included if mandatory. Included terminal bolts:
- OTD315...400: M10x30
- OTDC500: M12x40

Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles UL98B / 1000 V Type Order number [kg] Direct mount (K)
Mechanism between the poles
3 250 OTDC250U12 1SCA135619R1001 4.7 OTDV400EK
3 320 OTDC320U12 1SCA135791R1001 4.7
3 400 OTDC400U12 1SCA135792R1001 4.7

OTDCKIT400S101 Connection kits and shrouds


See pages 30-31 for circuit diagrams, connection kits and shrouds. The column "Needed
quantity" tells how many pieces need to be ordered for each switch. The kits include the
needed short circuit links, screws and washers.

Connection kit/ Recommended


short circuit link shroud
Circuit Needed Needed
Switches type Type quantity Type quantity
OTDC250400U12 5a, 5b, 5e OTDCKIT400S101 1 OEZXY97 1
OTDC250...400U12 5c, 5d OTDCKIT400S101 2 OEZXY97 2
*)
Tested as per UL98B 1000 VDC requirements, 1500 VDC standard has not been published yet

Switches for PV applications | Ordering information 29


Circuit 5a, 5b, 5e, 1500 VDC

-(+) OTDCKIT400S101

OEZXY97
-(+) +(-) +(-)

OTDCB_/_*)

Circuit 5a, 5b, 5e


Accessories for OTDC315...500E, OTDC250...400U
Order Needed
Description Type number quantity
Needed short circuit link -KIT OTDCKIT400S101 1SCA136280R1001 1
Recommended shroud OEZXY97 1SCA130816R1001 1

Circuit 5c, 5d, 1500 VDC


OTDCKIT400S101
+(-)

+(-)

OTDCB_/_*) OEZXY_

Circuit 5c, 5d
Accessories for OTDC250...400U
Order Needed
Description Type number quantity
Needed short circuit link -KIT OTDCKIT400S101 1SCA136280R1001 2
Recommended shroud OEZXY_ 1SCA130816R1001 2

*)
OTDCB_/_ phase barrier(s) included if mandatory

30 Ordering information | Switches for PV applications


Circuit 7b, 7g, 1500 VDC

-(+) -(+) OTDCKIT400S11

OTDCS400G2B
-(+) +(-) +(-) -(+) +(-) +(-)

OTDCB400/2*)
1 2

Circuit 7b, 7g
Accessories for OTDC315...500E
Order Needed
Description Type number quantity
Needed short circuit link -KIT OTDCKIT400S11 1SCA136281R1001 2
Recommended shroud OTDCS400G2B 1SCA136274R1001 2

*)
OTDCB_/_ phase barrier(s) included if mandatory

Switches for PV applications | Ordering information 31


OTDC100800 ordering information
Side operated disconnect switches, UL

OTDC100...200U20S Single circuit, 1000 VDC, UL98B - 100...400 A


Shafts and handles are not included. OTDC_US types inlcude pre-mounted short circuit link.
The mechanism is located at the end of the switch. Included terminal bolts:
- OTDC100...200: M8x25
- OTDC250..320: M10x30
- OTDC400: M12x40
OTDC100...200US20S
Number Rated operat. Weight/ Recommended
of current [A] unit handle
poles UL98B / 1000 V Type Order number [kg] Direct mount (K) External (P)+ shaft
Single circuit
2 100 OTDC100US20S 1SCA131541R1001 1.7 OHB65JE005
2 200 OTDC200US20S 1SCA131549R1001 1.7 + shaft OXP6X210
OTDC250...400U20S 2 100 OTDC100U20S 1SCA131540R1001 1.3 OHB65JE005
2 200 OTDC200U20S 1SCA131548R1001 1.5 + shaft OXP6X210
2 250 OTDC250US20S 1SCA135730R1001 4.4 OTDV400ESK OHB145J12E00S +
2 320 OTDC320US20S 1SCA135734R1001 4.4 shaft OXP12x185
2 400 OTDC400US20S 1SCA135726R1001 4.4
2 250 OTDC250U20S 1SCA135729R1001 3.8 OTDV400ESK OHB145J12E00S +
2 320 OTDC320U20S 1SCA135733R1001 3.8 shaft OXP12x185
2 400 OTDC400U20S 1SCA135725R1001 3.8

OTDCKIT400S101 Connection kits and shrouds


Pre-mounted short circuit links/connection bars are included for all OTDC_US types. Shrouds
must be ordered separately. See page 33 for circuit diagrams, connection kits and shrouds.
The column "Needed quantity" tells how many pieces need to be ordered for each switch. The
kits include the needed short circuit links/bars, screws and washers.

Connection kit/ Recommended


short circuit link shroud
Circuit Needed Needed
Switches type Type quantity Type quantity
OTDC100200US20S 1a - - OEZXY92 1
OTDC100200U20S 2a, 2b - - - -
OTDC250400US20S 1a - - OEZXY97 1
OTDC250400U20S 1a OTDCKIT400S101 1 OEZXY97 1
OTDC250400U20S 2a, 2b - - - -

32 Ordering information | Switches for PV applications


Circuit 1a, 1000 VDC
OTDC100...200U_S OTDC250400U_S

OEZXY91 OEZXY96

+(-) +(-)
+(-) +(-)

OTDCB_/_*) OTDCB_/_*)

Circuit 2a, 2b, 1000 VDC


S OTDC250400U_S

+(-) -(+)

+(-) +(-)

_*) OTDCB_/_*)

*)
OTDCB_/_ phase barrier(s) included if mandatory

Switches for PV applications | Ordering information 33


OTDC1632 ordering information
Accessories

OHBS11 Handle knobs for base and DIN rail mounted switches
Mounting directly to the switch, no shaft needed, for base and DIN-rail mounted switches
Padlockable with one padlock with bail diameter 5 mm, see the table below.

Handle
OHRS21 length
Colour [mm] Type Order number
Suitable for switches OTDC16...32F
Black 31 OHBS1 1SCA109087R1001
Black 31 OHBS1/1 1SCA109088R1001
Red 31 OHRS1 1SCA109095R1001
OHRS31 Red 31 OHRS1/1 1SCA109096R1001
Suitable for switches OTDC16...32F
Black 40 OHBS2 1SCA109089R1001
Black 40 OHBS2/1 1SCA109090R1001
Red 40 OHRS2 1SCA108598R1001
Red 40 OHRS2/1 1SCA108599R1001
Black 39 OHBS3 1SCA108320R1001
Black 39 OHBS3/1 1SCA108319R1001
Red 39 OHRS3 1SCA108667R1001
Red 39 OHRS3/1 1SCA108688R1001

Special information for handle knobs


Shaft through 45 mm
Handle type Padlockable the handle cut-out enable*
OHBS1_, OHRS1_ No No Yes
OHBS2_, OHRS2_ Yes No Yes
OHBS3_, OHRS3_ No No Yes
* In I-position the handle shall remain within the cut-out height

34 Ordering information | Switches for PV applications


OTDC1632 ordering information
Accessories

OHBS3PH Selector handles, for door mounted switches


Indication I-O and ON-OFF. No separate shaft needed.

Colour Type Order number


OHBS2PJ Snap-on mounting, door drilling 22,5 mm, for OTDC16...32FT
No padlocking, IP54, NEMA 1
Black OHBS1PH 1SCA105211R1001
Red-yellow OHYS1PH 1SCA105294R1001
Silver OHSS1PH 1SCA105276R1001
Grey OHGS1PH 1SCA105263R1001
Padlockable with one padlock, IP54, NEMA 1
OHYS3RH Black OHBS3PH 1SCA105236R1001
Red-yellow OHYS3PH 1SCA105327R1001
Silver OHSS3PH 1SCA105285R1001
Grey OHGS3PH 1SCA105272R1001
Padlockable with max. 3 padlocks, IP65, NEMA 1, 3R, 12
Black OHBS2PJ 1SCA105231R1001
Red-yellow OHYS2PJ 1SCA105322R1001
OHYS2RJ Silver OHSS2PJ 1SCA105280R1001
Grey OHGS2PJ 1SCA105268R1001
Screw mounting, hole distance 36 mm, for OTDC16...32FT
No padlocking, IP54, NEMA 1
Black OHBS1RH 1SCA105212R1001
Red-yellow OHYS1RH 1SCA105295R1001
Silver OHSS1RH 1SCA105277R1001
Grey OHGS1RH 1SCA105264R1001
Padlockable with one padlock, IP54, NEMA 1
Black OHBS3RH 1SCA105237R1001
Red-yellow OHYS3RH 1SCA105328R1001
Silver OHSS3RH 1SCA105286R1001
Grey OHGS3RH 1SCA105273R1001
Padlockable with max. 3 padlocks, IP65, hole distance 36/48 mm, NEMA 1, 3R, 12
Black OHBS2RJ 1SCA105232R1001
Red-yellow OHYS2RJ 1SCA105323R1001
Silver OHSS2RJ 1SCA105281R1001
Grey OHGS2RJ 1SCA105269R1001

Switches for PV applications | Ordering information 35


OTDC1632 ordering information
Accessories

OHBS3 Selector handles for base and DIN-rail mounted switches


Indication I-O and ON-OFF, for shaft diameter 6 mm, door drilling 22.5 mm.

Colour Type Order number


IP 54 handles, NEMA 1, suitable for switches OTDC16...32F
OHYS3 Black OHBS1AH 1SCA102680R1001
Yellow-red OHYS1AH 1SCA105290R1001
Silver OHSS1AH 1SCA105274R1001
Grey OHGS1AH 1SCA105261R1001
Door interlock in ON-position.
Black OHBS1AH1 1SCA105210R1001
Yellow-red OHYS1AH1 1SCA105291R1001
Silver OHSS1AH1 1SCA105275R1001
OHBS2 Grey OHGS1AH1 1SCA105262R1001
Padlockable with one padlock with bail diameter 5...6.3 mm.
Black OHBS3AH 1SCA105234R1001
Yellow-red OHYS3AH 1SCA105325R1001
Silver OHSS3AH 1SCA105283R1001
Grey OHGS3AH 1SCA105270R1001
Padlockable with one padlock with bail diameter 5...6.3 mm, door interlock in ON-position.
Black OHBS3AH1 1SCA105235R1001
Yellow-red OHYS3AH1 1SCA105326R1001
Silver OHSS3AH1 1SCA105284R1001
Grey OHGS3AH1 1SCA105271R1001
IP 65 handles, NEMA 1, 3R, 12, suitable for switches OTDC16...32F
Padlockable with max. 3 padlocks with bail diameter 5...8 mm, door interlock in ON-position, defeatable.
Black OHBS2AJ 1SCA105213R1001
Yellow-red OHYS2AJ 1SCA105296R1001
Silver OHSS2AJ 1SCA105278R1001
Grey OHGS2AJ 1SCA105265R1001
Padlockable with max. 3 padlocks with bail diameter 5...8 mm, door interlock in ON-position.
Black OHBS2AJ1 1SCA105215R1001
Yellow-red OHYS2AJ1 1SCA105297R1001
Silver OHSS2AJ1 1SCA105279R1001
Grey OHGS2AJ1 1SCA105266R1001

Selector type handle with metal hasp


IP65 handles, NEMA 1, 3R, 12, suitable for switches OTDC16...32F
Padlockable with max. 3 padlocks, door interlock in the ON-position, defeatable.
Black OHBS2AJEH 1SCA108230R1001

36 Ordering information | Switches for PV applications


OTDC1632 ordering information
Accessories

OXS6X_ Extended shafts for selector handles

Shaft Weight/
length H unit
[mm] [mm] Type Order number [kg]
Suitable for switches OTDC16...32F, shaft diameter 6 mm
85 See OXS6X85 1SCA101647R1001 0.02
105 dimension OXS6X105 1SCA108043R1001 0.02
120 drawings OXS6X120 1SCA101654R1001 0.03
130 OXS6X130 1SCA101655R1001 0.03
160 OXS6X160 1SCA101656R1001 0.04
180 OXS6X180 1SCA101659R1001 0.04
250 OXS6X250 1SCA101660R1001

Switches for PV applications | Ordering information 37


OTDC100800 ordering information
Accessories

OHY_ Pistol handles


OH_ handles for front operation: IP 65, NEMA 1,3R, 12
Padlockable with three padlocks in OFF-position, door interlock in ON-position. Screw fixing
from the back side of the handle ensures double insulation.

Handle Suitable Weight/


OHB_ length for unit
Colour [mm] switches Type Order number [kg]
For shaft diameter 6 mm, indication in types OHB and OHY: I-0, ON-OFF, in types OHG: I-0.
Black 65 OTDC100...250E_, OTDC100...200U_ OHB65J6 1SCA022380R9660 0.12
Yellow-red 65 OTDC100...250E_, OTDC100...200U_ OHY65J6 1SCA022380R9820 0.12
Grey 65 OTDC100...250E_, OTDC100...200U_ OHG65J6 1SCA022380R9740 0.12
Black 80 OTDC100...250E_, OTDC100...200U_ OHB80J6 1SCA022381R0240 0.14
Yellow-red 80 OTDC100...250E_, OTDC100...200U_ OHY80J6 1SCA022381R0410 0.14
Grey 80 OTDC100...250E_, OTDC100...200U_ OHG80J6 1SCA022381R0320 0.14
For shaft diameter 6 mm, indication: Test-OFF-ON/Test-0-I
Black 65 OTDC100...250E_, OTDC100...200U_ OHB65J6T 1SCA022399R8110 0.12
Yellow-red 65 OTDC100...250E_, OTDC100...200U_ OHY65J6T 1SCA022456R9540 0.12
For shaft diameter 12 mm, indication OHB and OHY: I-0, ON-OFF, in types OHG: I-0
Black 95 OTDC315...800E, OTDC250...600U_ OHB95J12 1SCA022381R0830 0.16
Yellow-red 95 OTDC315...800E, OTDC250...600U_ OHY95J12 1SCA022381R1050 0.16
Grey 95 OTDC315...800E, OTDC250...600U_ OHG95J12 1SCA022381R0910 0.16
Black 125 OTDC315...800E, OTDC250...600U_ OHB125J12 1SCA022381R1560 0.17
Yellow-red 125 OTDC315...800E, OTDC250...600U_ OHY125J12 1SCA022381R1720 0.17
Grey 125 OTDC315...800E, OTDC250...600U_ OHG125J12 1SCA022381R1640 0.17
Black 145 OTDC315...800E, OTDC250...600U_ OHB145J12 1SCA022381R2110 0.17
For shaft diameter 12 mm, indication: Test-OFF-ON/Test-0-I
Black 95 OTDC315...800E, OTDC250...600U_ OHB95J12T 1SCA022736R1750 0.16
Yellow-red 95 OTDC315...800E, OTDC250...600U_ OHY95J12T 1SCA022736R1910 0.16
Black 125 OTDC315...800E, OTDC250...600U_ OHB125J12T 1SCA022652R2220 0.16
Yellow-red 125 OTDC315...800E, OTDC250...600U_ OHY125J12T 1SCA022652R2310 0.16
Door interlocking in ON-position means that the door cannot be opened when the handle is in ON-position. This can be defeated in IP65 types to allow
authorized personnel access for inspection. NEMA 4, 4x pistol handles available on request. Handles padlockable in all positions available on request.

OH_ handles for side operation: IP 65, NEMA 1,3R, 12


For mounting on the side of the enclosure. Padlockable with three padlocks in the OFF-position,
door interlock in the ON-position, IP 65. The position indications are rotated 90.

Handle Suitable Weight/


length for unit
Colour [mm] switches Type Order number [kg]
Side operation: for shaft diameter 6 mm, indication in types OHB and OHY: I-0, ON-OFF, in types OHG: I-0.
Plastic handles
Black 65 OTDC100...200U_S OHB65J6E00S 1SCA022382R9850 0.12
Red-yellow 65 OTDC100...200U_S OHY65J6E00S 1SCA022382R9930 0.12
Grey 65 OTDC100...200U_S OHG65J6E00S 1SCA022383R4510 0.12
Side operation: for shaft diameter 6 mm, indication: Test/I-O/ON-OFF, grey: Test/I-O
Black 65 OTDC100...200U_S OHB65J6TE00S 1SCA109016R1001 0.12
Red-yellow 65 OTDC100...200U_S OHY65J6TE00S 1SCA022688R0140 0.12
Grey 65 OTDC100...200U_S OHG65J6TE00S 1SCA109014R1001 0.12
Side operation: for shaft diameter 12 mm, indication I-O/ON-OFF
Plastic handles
Black 145 OTDC250400U_S OHB145J12E00S 1SCA022679R9700 0.17

38 Ordering information | Switches for PV applications


OTDC100800 ordering information
Accessories

OT_V_ Direct mount handles


Handle Suitable Weight/
length for unit
Colour [mm] switches Type Order number [kg]
Indication Test-OFF-ON/Test-O-I.
Padlockable with three padlocks in OFF-position. Includes shaft and mechanism cover.
Black 65 OTDC100...250E_, OTDC100...200U_2) OTDV250EK 1SCA127390R1001 0.10
Red-yellow 65 OTDC100...250E_, OTDC100...200U_2) OTDVY250EK 1SCA127391R1001 0.10
Black 95 OTDC315800E, OTDC250600U_ 2) OTDV400EK 1SCA130579R1001 0.3
Black 145 OTDC315800E, OTDC250600U_ 2) OTDV500EK 4) 1SCA135915R1001 0.65
Black 145 OTDC315800E, OTDC250600U_ 2) OTDV400EK2 1SCA137301R1001 0.65
Black 95 OTDC250400U_S 3) OTDV400ESK 1SCA136041R1001 0.1
2)
Valid only for front-operated switches
3)
Valid only for side-operated switches
4)
Handle lifted up with a higher mechanism cover, recommended for use with long terminal shrouds (OTDC400_L_)

OXP6X_ Extended shafts for pistol handles


Shaft Weight/
length H H unit
S06054

[mm] [mm] Type Order number [kg]

For pistol type handles


Suitable for switches OTDC100...250E_, OTDC100...200U_, shaft diameter 6 mm 1)
130 109174 OXP6X130 1SCA022057R0570 0.04
150 129194 OXP6X150 1SCA022295R5600 0.05
161 140...205 OXP6X161 1SCA022067R1760 0.05
210 189254 OXP6X210 1SCA022295R6080 0.06
290 269334 OXP6X290 1SCA022042R6370 0.08
1)
Longer shafts on request

Switches for PV applications | Ordering information 39


OTDC100800 ordering information
Accessories

OXP12X185 Extended shafts for pistol handles


Shaft Weight/
length H H unit

S06054
[mm] [mm] Type Order number [kg]

For pistol type handles


Suitable for switches OTDC315...800E, OTDC250...600U_, shaft diameter 12 mm
OXP6X150 166 146226 OXP12X166 1SCA022325R7100 0.2
185 165245 OXP12X185 1SCA022325R6710 0.2
250 230310 OXP12X250 1SCA022325R6980 0.28
280 260340 OXP12X280 1SCA022137R5140 0.3
325 305385 OXP12X325 1SCA022042R5810 0.36
395 445525 OXP12X395 1SCA022042R5990 0.43
465 439519 OXP12X465 1SCA022042R6020 0.51
535 515...595 OXP12X535 1SCA022042R6110 0.59

40 Ordering information | Switches for PV applications


OTDC100800 ordering information
Accessories

OTDCB_ Phase separators


Grey plastic plate for maintaining 1" clearance between the phases without terminal shrouds.
Snap-on mounting. Included as standard in OTDC100...600U_ or OTDC100...800E if use
mandatory.

Suitable Weight/
for Units/ unit
switches Type Order number type [kg]
OTDC100...250E_, OTDC100...200U_ OTDCB250/6 1SCA125532R1001 6
OTDC315800E, OTDC250600U_ OTDCB400/2 1SCA132183R1001 2

OEZKL10/4
Mounting feet
Higher (10 mm) optional mounting feet to lift the switch up from the mounting base. The
delivery includes 4 mounting feet and screws.

Suitable Weight/
for unit
switches Type Order number [kg]
OTDC315...800E, OTDC250...400U OEZKL10/4 1SCA132180R1001

Switches for PV applications | Ordering information 41


OTDC100800 ordering information
Accessories

OA1G10, OA3G01 Auxiliary contact blocks, IP20


Contact numbering according to EN 50013.
The type and and the ordering numbers are for one piece.

Mounting on the left side of the switch or under the mechanism cover
Mounting on the left side of the switch:
OEA28 Max. 8 auxiliary contact blocks with the OEA28 module.
Mounting under the mechanism cover:
OTDC100...250E, OTDC100...200U_: Max. 4 test contacts or 2 test contacts + 2 test
indication contacts.1)
OTDC315...800E, OTDC250...600U_: Max. 4 test contacts + 4 test indication contacts. 1)
The test contacts can be used as standard auxiliary contacts as well.

Suitable Delivery Weight/


for batch unit
switches Function Type Order number [pcs]2) [kg]
OTDC100...800E, OTDC100...600U_ 1NO OA1G10 1SCA022353R4970 10 0.03
OTDC100...800E, OTDC100...600U_ 1NC OA3G01 1SCA022456R7410 10 0.03

Module for auxiliary contacts


Screw mounting to the left side of the switch.

Suitable Delivery Weight/


for batch unit
switches Type Order number [pcs] [kg]
OTDC100..800E, OTDC100...600U_ OEA28 1SCA022714R8810 1 0.04
1)
Contact numbering:
(83) (43) (53) 13 21 (61) (31) (71)
(84) (44) (54) 14 22 (62) (32) (72)
2)
Auxiliary contacts OA1G_ are available in larger packing as well.
A bulk package includes 50 auxiliary contacts. Type number: add a suffix: /B, e.g. OA1G01/B.

Performance data according to IEC 60947-5-1


For OA1G_, OA3G_
Ue/[V] AC15 Ue/[V] DC12 DC13
Ie/[A] Ie/[A] P/[W] Ie/[A] P/[W]
230 6 24 10 240 2 50
400 4 72 4 290 0.8 60
415 4 125 2 250 0.55 70
690 2 250 0.55 140 0.27 70
440 0.1 44

42 Ordering information | Switches for PV applications


OTDC100800 ordering information
Accessories

OEZXY91 Short circuit and connection bar kits


Refer to pages for circuit diagrams showing the possible connections and needed amounts of
kits. The kits include the necessary mounting hardware.

OTDCKIT400S101 Suitable Weight/


for unit
switches Type Order number [kg]
OTDC100...250E_ OEZXY91 1SCA125290R1001
OTDC315500E, OTDC250400U OTDCKIT400S101 1SCA136280R1001 0.38
OTDC315500E, OTDC250400U OTDCKIT400S11 1SCA136281R1001 0.54
OTDCKIT400S11 OTDC315500E, OTDC250400U OTDCKIT400B11 1SCA136282R1001 0.29
OTDC315500E OTDCKIT400B111 1SCA136284R1001 0.47
OTDC600UPP OTDCKIT400B202 1SCA136285R1001 0.910
OTDC250400US OTDCKIT400B101 1SCA136283R1001 0.375

OTDCKIT400B11

OTDCKIT400B101

OTDCKIT400B111

OTDCKIT400B202

Switches for PV applications | Ordering information 43


OTDC100800 ordering information
Accessories

OTS250G1S Terminal shrouds


The type and ordering numbers are for one piece.

Suitable Weight/
OTS250G1L for unit
switches Description Type Order number [kg]
Grey
OTDC100...250E, OTDC100...200US short OTDCS250G1S 1SCA125563R1001 0.01
OTDC315...500E, OTDC250...400US short OTDCS400G1S 1SCA132361R1001 0.05
OTDC315...500E, OTDC250...400US long OTDCS400G1L 1SCA132362R1001 0.1
Transparent
OTDC100...250E, OTDC100...200US short OTDCS250T1S 1SCA125580R1001 0.01
OTDC315...500E, OTDC250...400US short OTDCS400T1S 1SCA132363R1001 0.05
OTDCS400G2B OTDC315...500E, OTDC250...400US long OTDCS400T1L 1SCA132364R1001 0.1

Shrouds for short circuit links/connection bars


The type and ordering numbers are for one piece.

Suitable Suitable for short Weight/


for circuit link/ unit
OEZXY97 switches connection bar Type Order number [kg]
Grey
OTDC315...500E, OTDC250...400U OTDCKIT400S11 OTDCS400G2B 1SCA136273R1001
OTDC600USPP OTDCKIT400B202 OTDCS250G4B 1SCA136274R1001 0.07
OTDC100...200US, OTDC100...250E OEZXY91 OEZXY92 1SCA127382R1001
OTDC315...500E, OTDC250...400U_ OTDCKIT400S101 OEZXY97 1SCA130816R1001 0.1
OTDCS400T2L OTDC315800E, OTDC250600U_ OTDCKIT400B11 OTDCS400T2L 1SCA136275R1001 0.13
OTDC315500E, OTDC250400U OTDCKIT400B101 OTDCS400T11L 1SCA136279R1001
OTDC315...500E OTDCKIT400B111 OTDCS400T3L 1SCA136276R1001

OTDCS400T11L

44 Ordering information | Switches for PV applications


52,5 A 16,
16,25 B
Dimension drawings C
Switch-disconnectors
I - ON
38,5

89 O - OFF
36,5 69
45 D
OTDC16...32F_, base or DIN-rail mounting (IEC)
40 10,6
52,5 A 16,5
16,25 B
C

4,5 4
21,25 I - ON
38,5
5
89 O - OFF
36,5 69
B

45 D
S07151 / M00371 / OTDC16-32_

22
40 10,6

4,5 4
21,25 5
B
S07151 / M00371 / OTDC16-32_

OTDC16...32F_
Dimension [mm]
Number of poles A OTDC16...32F_ B C D
Dimension [mm]

2 66,2 Number of poles 54,1


A B 38,3
C D 22
2 66,2 54,1 38,3 22
3 77,6 3 65,5
77,6 65,5 49,7
49,7 33,4 33,4
4 89 76,9 61,1 44,8
4 89 76,9 61,1 44,8

OTDC16...32FT_, door mounting (IEC)

22
B E OH_S1P
OH_S1R OH_S2P
C
45
D
10,6 22
B E OH_S1P
OH_S1R OH_S2P
C
69 36
45

69
36

52,5
B
M00416/OTDC32FT-1

OTDC32FT_
M00416/OTDC32FT-1

[mm] B C D E
OTDC32FT_
FT2 64,1 38,3 22 79,9 [mm] B C D E
FT3 75,5 49,7 33,4 91,3 FT2 64,1 38,3 22 79,9
FT3 75,5 49,7 33,4 91,3
FT4 86,9 61,1 44,8 102,7
FT4 86,9 61,1 44,8 102,7

Switches for PV applications | Dimension drawings 45


Dimension drawings
Switch-disconnectors
m 35 35,5 OTDC100, 160, 200, 250E01...04K
1,38 1,40 3
0,12 OTDC100, 180, 200U01, 200U01...04K
82,5
3,25 80
20 O9 35 3,15 37
0,79 10 0,35 1,38 25 1,46
M5 0,39 0,98
6
0,24
45
ON

OFF
1,77
6
0,24
126
ON 176
4,96OTDC100...200U02
OTDC100...250E02, (IEC and UL)
OFF

6,93 65 107
156 2,56 4,22
6,14
65
mm 2,56
35 35,5 3 14 min 8,5 160, 200, 250E01...04K
OTDC100, 17,5
in 1,38 1,40 0,33 26,5
0,12 0,55 min OTDC100, 180, 200U01, 200U01...04K0,69 1,04

82,5
3,25 80
mm
20 35 O9 35 35,5 3,15 OTDC100, 160, 200, 250E01...04K 37
in 60 1,38 3
2

0,79 10 1,38 0,35 1,40 1,46


1

0,12 25
43,5M5 0,39 35 2,36 0,98
OTDC100, 180, 200U01, 200U01...04K
144 ON

139 ON
108 ON

1,71 1,38 20 35

OFF

OFF
OFF
82,5 6 5,67 5,48 4,25
0,79
O
1,38 3,25 80 0,24
20 9 35 3,15 45
ON

37

OFF
0,79 10 0,35 1,38 25 1,77 1,46
73,5 11
M5 A 0,39 0,98
0,43
2,89 88,5
6 6
72 0,24
3,48 45 0,24
ON

OFF

126 1,77
ON 4,96 176 189...254/7,44...10,01 A1 B1 C1
(OXP 6x210)
6
OFF

72 6,93 0,24
65 107
156 2,56 4,22
126 6,14
ON 4,96 176
OFF

6,93 65 107
156 65 2,56 4,22
6,14 2,56
14 min 8,5 17,5
65 0,33 26,5
0,55 min 2,56 0,69 1,04
C100, 160, 200, 250E01...04 14 min 8,5 17,5 26,5
m 35 35,5 0,55 min 0,33
OTDC100, 160, 200, 1,04
0,69
250E01...04K
C 100, 1,38
200U01...04 1,40 3
60 0,12 OTDC100, 180, 200U01, 200U01...04K
2

/in] 01 43,5 02 35 602,36


2003 35 04 144 139 108
2

ON ON
1

ON

1,7143,5 1,38
35 2,36
OFF

OFF
OFF
144 ON

5,67 139 5,48 108 ON

4,25
0,79
ON

1,71 1,38 2082,5351,38


OFF

OFF
OFF

78/3,07 113/4,45 148/5,83


3,25 183/7,21
0,79 1,38 80
5,67 5,48 4,25

20 O9 AA 35 73,5 73,5 3,15 11 11 37


52/2,05
0,79 10 87/3,43
0,35 122/4,81
1,38 157/6,18 2,89 88,5
2,89 88,5
25 3,48
0,43 0,43
1,46
3,48
0,39
M5 70/2,76 105/4,14 140/5,51 175/6,89 0,98
189...254/7,44...10,01
189...254/7,44...10,01 A1 B1 C1
(OXP 6x210) A1 B1 C1
(OXP 6x210) 6 OTDC100, 160, 200, 250E11...22K
88/3,46 123/4,85 158/6,22 35,5
193/7,6 3 0,24
35 45
ON

1,40 0,12 OTDC100, 180, 200U11...22K


OFF

1,38 1,77
A

OTDC100, 160, 200, 250E01...04


A

82,5 6
M00414/OTDC200-250E01-04

OTDC100, 160,200U01...04
200, 250E01...04 80
20 OTDC 100, 3,25 3,15 0,24
M00414/OTDC200-250E01-04

0,79 O9 37
OTDC
1,38 4,96 0,35 3502 126
100, 200U01...04
[mm/in] 01 03 04 1,46
ON 78/3,07 113/4,45 176
A
[mm/in] 01 02 148/5,8303 183/7,21 04
OFF

10 6,93 65 107
0,39
A1 52/2,05 87/3,43 156
122/4,81 157/6,18 6 2,56 4,22
A 78/3,07 113/4,45 148/5,83
6,14 183/7,21 25
B1 70/2,76 105/4,14 140/5,51 175/6,89 0,98 0,24 ON

A1 C1 52/2,05 87/3,43 122/4,81 193/7,6


157/6,18 45
OFF

88/3,46 123/4,85 158/6,22 65


B1 70/2,76 105/4,14 140/5,51 175/6,89 1,77 2,56
8,5 17,5
14 min 0,33 26,5
C1 88/3,46 123/4,85 158/6,22 193/7,6 0,55
6 min 0,69 1,04
126 176 0,24
ON 4,96 6,96
65 107
OTDC100...250E11,
15660OTDC100...200U11 (IEC and UL)
OFF

2,56
2

4,22
1

43,5 35 6,14
2,36 144 ON

139 ON
108 ON

1,71 1,38 20 35
OFF

OFF
OFF

65 5,67 5,48 4,25


0,79 1,38
mm 2,56 OTDC100, 160, 200, 250E11...22K
in 35,5 3 14 min 11 A2
A 35 73,5
1,40 B2 C2
1,38 2,89 88,5 0,12 0,43
0,55 min OTDC100, 180, 200U11...22K
mm OTDC100, 160, 200, 250E11...22K
in 35,5
35 82,5 1,40
3 3,48
1,38 0,12 80 OTDC100, 180, 200U11...22K
20 3,25 189...254/7,44...10,01
3,15 A1 37 B1 C1
0,79 35 O 90,35 82,535 80 (OXP 6x210) 1,46
1,38
2

20 1,38 3,25 3,15


1

70 35/
0,79 1,38 O9 37
10 60 35
0,35 1,38
144
ON
1,46 139 ON

108
ON

2,76 6
OFF
OFF

OFF

10
0,39 2,36 25 0,24 5,67 5,48 4,25
A 0,39 25 6 0,98 ON

0,24 45
OFF

0,98 ON

45 1,77
OFF

B 73,5 111,77
C100, 160,72200, 250E01...04
72
2,83 2,89 1,43 6
2,83 6
126 126 176 176 88,5 0,24 0,24
C 100, 200U01...04 ON ON 4,96 4,96 6,96 6,96 3,48
189...254/ 7,44...10,01 65 65 A1
107 107 B1 C1
OFF
OFF

156
in] 01 02 03 6,14 156
6,14 04 (OXP 6x210)
2,56 4,22
2,56 4,22
65
78/3,07 113/4,45 148/5,83 183/7,21 2,56 65
14 min 2,56
A2 B2 C2
0,55 min
52/2,05 87/3,43 122/4,81 157/6,18 14 min
0,55 min
A2 B2 C2

70/2,76 105/4,14 140/5,51


35 175/6,89
2

1,38
1

70 35/ 1,38
6035 144
ON
139 ON

108
ON

2,76
88/3,46 123/4,85 158/6,22 193/7,6
OFF
OFF

OFF

2,36 5,48
2

1,38 5,67 4,25


1

A
70 35/ 1,38
60 144
ON
139 ON

108
ON

C100, 160, 200, 250E11...22


2,76B
OFF
OFF

OFF

2,36 73,5 11 5,48 4,25


A 35,5 2,89
1,43 5,67 OTDC100, 160, 200, 250E11...22K
88,5 3
35
C100, 200U11...22 1,40 3,48 0,12
1,38 B 73,5
189...254/ 7,44...10,01
2,89
11
1,43
A1 OTDC100,
B1 180, 200U11...22K
C1
(OXP 6x210)
in] 11 12 13 22 88,5
82,5 80 3,48
20 3,25 189...254/ 7,44...10,01 A1 B1 C1
80/3,15 80/3,15 80/3,15 115/4,53 3,15 37
0,79 35 O9 (OXP 6x210)
1,38 0,35 1,46
115,5/4,55 150,5/5,93 185,5/7,31 185,5/7,31
10
87/3,43 122/4,81
0,39 OTDC100, 157/6,18
160, 200, 250E11...22 157/6,18 25 6
OTDC100, 200U11...22 0,98 0,24 ON

43,5/1,71[mm/in]
43,5/1,71 43,5/1,71 78,5/3,09 45
OFF

11 12 13 22
1,77
105/4,14A 140/5,51
80/3,15
OTDC100, 175/6,89
160, 200,80/3,15 80/3,15175/6,89
250E11...22 115/4,53
A

OTDC100, 200U11...22 B 115,5/4,55 150,5/5,93 185,5/7,31 185,5/7,31 6


52,5/2,07 52,5/2,07 52,5/2,07 87,5/3,44
M00415/OTDC200-250E11-22

A1 87/3,43 126
122/4,81 176
157/6,18 157/6,18 0,24
[mm/in] 11 4,96 13
6,96 78,5/3,09 12
22
123/4,85A2 158/6,22 193/7,6
43,5/1,71 193/7,6
ON
43,5/1,71 43,5/1,71
65 107
OFF

AB1 80/3,15 140/5,51


105/4,14 80/3,15 80/3,15
156 175/6,89 175/6,89115/4,53 2,56
61,5 61,5 150,5/5,93 61,5185,5/7,3196,5 4,22
A

B B2 115,5/4,55 6,14
52,5/2,07 52,5/2,07 185,5/7,31
52,5/2,07 87,5/3,44
M00415/OTDC200-250E11-22

C1
A1 123/4,85
87/3,43 158/6,22
122/4,81193/7,6 193/7,6157/6,18
157/6,18 65
61,5 61,5 61,5 2,56
C2
A2 43,5/1,71 43,5/1,71 43,5/1,71 96,5
78,5/3,09 14 min A2 B2 C2
B1 105/4,14 140/5,51 175/6,89 175/6,89 0,55 min
52,5/2,07 52,5/2,07 52,5/2,07 87,5/3,44
46B2Dimension drawings | Switches for PV applications
C1 123/4,85 35158/6,22 193/7,6 193/7,6
2

35/ 1,38 61,5 1,38 61,5


1

70 C2 60 61,5 96,5 ON
139 ON

108
ON

144
OFF
OFF

OFF
Dimension drawings
Switch-disconnectors

OTDC315/400/500E01-04, OTDC250/320/400U01-04 (IEC and UL)

149
mm 5,87
in 111
4,37

25
60,5 0,98
M5
2,38 13 136 48 4
35 0,51 7 5,36 1,89 0,16
0,38 13 0,28
0,51 52
2,05 39/1,54
12 43
0,47 1,69
82 45
3,23 149 149 1,77
5,87 5,87
187 111 227
128
5,04 7,37 4,378,94
95
25 3,74
60,5 0,98
M5
2,38 13 136 48 4 OTDC315, 400, 500E_K
35 0,51 7 5,36 1,89 0,16 51 20 min
0,38 13 0,28 2,01 0,79 min OTDC250, 320, 400U_K 95 148
0,51 52 3,74 5,83
2,05 39/1,54
129
A1
5,08 12 43
0,47 1,69
45
1,77
149
104,5 9
28 187 227 5,87 4,12 0,35
,04 7,37 8,94
A 165...255/6,5...10,05 95
95
(OXP12x185)
M00442/OTDC250-630_01-04 B

3,74 3,74
OTDC315, 400, 500E_
OTDC250, 320, 400U_
[mm/in] 01 02 03 51 04 20 min
2,01 0,79 min 95 148
A 130/5,12 199/7,84 268/10,56 337/13,28 3,74 5,83
A1 139/5,48 208/8,19 277/10,91
129 346/13,63
A1
5,08

104,5 9
OTDC315/400/500/800E11-33, OTDC250/320/400/600U11-33
4,12 0,35 (IEC and UL)
A 165...255/6,5...10,05
(OXP12x185)
149
mm 111 5,87
in 4,37

A2 60,5
2,38 136
5,36
25 13
0,98 0,51 52 48 4
7 2,05 1,89 0,16
0,28
13
0,51 39/1,54
M5
12 43
0,47 1,69
149 45
82 1,77
3,23 5,87
128 187 227
5,04 7,37 8,94
95
3,74
149
111 5,87
4,37
20 min 51
60,5 0,79 min 2,01 95 148
A2 136
2,38 3,74 5,83
5,36 129
25 13
0,98 A1 52 4 5,08
0,51 48 OTDC315, 400, 500, 800E_K
7 2,05 1,89 0,16
0,28
13 OTDC250, 320, 400, 600U_K
0,51 39/1,54 111
4,37
121 69 43
4,77 2,72 12 104,5 9
0,47
4,12 144 0,35 1,69
149 45
2 A 5,67
1,77
,23 5,87
165...255/6,5...10,05
187 227 (OXP 12x185)
7,37 8,94
95
M00443/OTDC250-630_11-22 C

OTDC315, 400, 500, 800E_ 1) 95


OTDC250, 320, 400, 600U_ 1) 3,74 3,74

[mm/in] 11 12 13 22 33
A 197/7,76 266/10,48 335/13,2 335/13,2 20 min
473/18,62 51
0,79 min 2,01 95 148
A1 208/8,19 277/10,91 346/13,63 346/63 484/19,06
3,74 5,83
A2 104/4,1 104/4,1 104/4,1 173/6,81 242/19,53 129
1) A1
800E & 600U only available as _22 version 5,08

111
4,37 Switches for PV applications | Dimension drawings 47
121 69
4,77 2,72 104,5 9
4,12 144 0,35
Dimension drawings
Side operated disconnect-switches

76,9
3,03
69,7 35 9
48,5 3
OTDC100/180/200U02-04S (UL) 2,75 1,38 0,35
35,2
1,91 0,12
10
M5 0,39 1,39
25
76,9 8,5
mm 0,98 3,03 0,33
69,7 35 9
in 2,75 1,38 0,35
48,5 3
1,91 0,12
72 10 35,2
2,83 M5 0,39 1,39
25 8,5
0,98 0,33
126 156 176 144
4,96 6,14 6,93 5,67
72
2,83

126 156 176 144


4,96 6,14 6,93 5,67
A1
17,5
39,5 63,2 0,69
43,5 35 1,56 2,49
1,71 1,38
B 85
3,35
A
102,7 A1
4,04 63,2 17,5
39,5 139 0,69
43,5 35 1,56 2,49 5,48
1,71 1,38
B 85
3,35
A
102,7
4,04 139 B1
26,5
5,48
1,04

108 B1
OTDC100, 180, 200U02...04S 4,25 26,5
A

1,04
13/OTDC100-200U02-04S

[mm/in] 02 04
A 163/6,41 233/9,61
B 146/5,74 216/8,50
A1 87/3,43 157/6,18
B1 105/4,13 175/6,89
C1
C1 123/4,84 193/7,60
108
OTDC100, 180, 200U02...04S 4,25
A
13/OTDC100-200U02-04S

[mm/in] 02 04

OTDC250/400U02S (UL) A 163/6,41 233/9,61


B 146/5,74 216/8,50
A1 87/3,43 157/6,18
B1 149 175/6,89
105/4,13
mm 5,87 149 17 C1
C1 123/4,84
111 193/7,60
5,87 0,67 17
in 4,37 111 0,67
4,37

136 164
60,5 5,36 136 6,46
2,38 48 164
60,5 5,36 6,46
13 2,38 4 1,89 48
0,51 13 0,16 4 1,89
0,51 0,16

M5 52 39
2,05 52
1,54
M5 39
12 2,05 1,54
0,47 38 171
12 6,74
0,47 1,50 38 171
45 1,50 6,74
82 187
1,77 45 3,23 26
82 7,37 187 1,02
1,77 3,23 26
7,37 1,02
227
8,94 227
8,94
137 149 159
5,4 137 5,87 149 6,26 159
95
3,74 155 5,4 5,87 6,26
95
3,74 6,11 155
182 6,11
7,17 182 20 min
7,17 7 51 0,79 20 min
13 0,28 7 2,01 51 0,79
0,51 13 0,28 2,01
250,51 190
0,98 25 7,48 190
0,98
A

129 7,48
A

5,08 35
129
M00472/OTDC400U_S

5,08 0,38 35
M00472/OTDC400U_S

0,38

77,5 69 127
3,05 77,5 2,72 69 5 128
127
235 3,05 2,72 5 5,04 128
9,26 235 5,04
9,26

208
8,19 208
8,19

48 Dimension drawings | Switches for PV applications


Dimension drawings
Enclosed switch-disconnectors,
short circuit links
OTDCP16...32 (IEC)

95 mm

95 mm

m
34,5 m
m
150 m
S07219

OEZXY91 (IEC and UL) OEZXY99 (IEC and UL)

mm mm
in in
35 50
1.38 1.79

35
35 1.38
1.38

20
0.79 40
1.57

M8
100
S07243

S06074

3.94
M8

OTDCKIT400S11 (IEC and UL) OTDCKIT400S101 (IEC and UL)

mm
in
38,7 48
1.52 1,89
64,7
2.54 74
2,91

mm
69,1 M12
in
2.72 20
0,79 52 69
S06080

2,05 2,72
161
6,34
50
1.97
30
1,18
S06075

M12 114
4.48

Switches for PV applications | Dimension drawings 49


Dimension drawings
Connection bars

OTDCKIT400B11 (IEC and UL) OTDCKIT400B101 (IEC and UL)


mm 99 mm 151
in 3,89 in 5,94

15 69 +- 0,2 15 121 +- 0,2


0,59 2,72 0,01 0,59 4,76 0,01

12,5 30 12,5 30
1,18 1,18

6 6

S06077
S06076

0,24 0,24

OTDCKIT400B111 (IEC and UL)

mm 168
in 6,61
15 138 +- 0,2
0,59 4,76 0,01

12,5 30
1,18

69 +- 0,2
2,72 0,01

6
S06078

0,24

OTDCKIT400B202 (IEC and UL)

mm 289
in 11,38
69 121 +- 0,2 69
2,72 4,76 0,01 2,72

13
50
1,97

5
S06078

0,19

50 Dimension drawings | Switches for PV applications


Index

Type Order number Description Page Type Order number Description Page
OA1G10 1SCA022353R4970 Auxiliary contact block 42 OTDC16F2 1SCA121454R1001 DC switch-disconnector 12
OA3G01 1SCA022456R7410 Auxiliary contact block 42 OTDC16F2 1SCA121454R1001 DC switch-disconnector 12
OEA28 1SCA022714R8810 Module for auxiliary contact 42 OTDC16F3 1SCA121457R1001 DC switch-disconnector 12
OEZKL10/4 1SCA132180R1001 Mounting feet 41 OTDC16F4 1SCA121461R1001 DC switch-disconnector 12
OEZXY91 1SCA125290R1001 Short circuit and connection bar kits 43 OTDC16U2 1SCA134369R1001 DC switch-disconnector 13
OEZXY92 1SCA127382R1001 Shrouds for short circuit links/ 44 OTDC16U4 1SCA134370R1001 DC switch-disconnector 13
connection bars OTDC16U6 1SCA134371R1001 DC switch-disconnector 13
OEZXY97 1SCA130816R1001 Shrouds for short circuit links/ 44 OTDC16US2 1SCA134372R1001 DC switch-disconnector 13
connection bars
OTDC16US4 1SCA134373R1001 DC switch-disconnector 13
OHB125J12 1SCA022381R1560 Handle 38
OTDC180U22 1SCA126941R1001 DC disconnect switch 23
OHB125J12T 1SCA022652R2220 Handle 38
OTDC180US22 1SCA126942R1001 DC disconnect switch 23
OHB145J12 1SCA022381R2110 Handle 38
OTDC200E02 1SCA123687R1001 DC switch-disconnector 18
OHB65J6 1SCA022380R9660 Handle 38
OTDC200E22 1SCA125856R1001 DC switch-disconnector 22
OHB65J6T 1SCA022399R8110 Handle 38
OTDC250E02 1SCA125866R1001 DC switch-disconnector 18
OHB80J6 1SCA022381R0240 Handle 38
OTDC250E22 1SCA125869R1001 DC switch-disconnector 22
OHB95J12 1SCA022381R0830 Handle 38
OTDC250U11 1SCA130985R1001 DC disconnect switch 19
OHB95J12T 1SCA022736R1750 Handle 38
OTDC250U22 1SCA131003R1001 DC disconnect switch 23
OHBS1PH 1SCA105211R1001 Handle 35
OTDC250US22 1SCA131030R1001 DC disconnect switch 23
OHBS1RH 1SCA105212R1001 Handle 35
OTDC25F2 1SCA121455R1001 DC switch-disconnector 12
OHBS2PJ 1SCA105231R1001 Handle 35
OTDC25F2 1SCA121455R1001 DC switch-disconnector 12
OHBS2RJ 1SCA105232R1001 Handle 35
OTDC25F3 1SCA121458R1001 DC switch-disconnector 12
OHBS3/1 1SCA108319R1001 Handle knob 34
OTDC25F4 1SCA121462R1001 DC switch-disconnector 12
OHBS3PH 1SCA105236R1001 Handle 35
OTDC25U2 1SCA134375R1001 DC switch-disconnector 13
OHBS3RH 1SCA105237R1001 Handle 35
OTDC25U4 1SCA134377R1001 DC switch-disconnector 13
OHG125J12 1SCA022381R1640 Handle 38
OTDC25US2 1SCA134378R1001 DC switch-disconnector 13
OHG65J6 1SCA022380R9740 Handle 38
OTDC25US4 1SCA134379R1001 DC switch-disconnector 13
OHG80J6 1SCA022381R0320 Handle 38
OTDC315E22 1SCA131001R1001 DC switch-disconnector 22
OHG95J12 1SCA022381R0910 Handle 38
OTDC315E33 1SCA137230R1001 DC switch-disconnector 26
OHGS1PH 1SCA105263R1001 Handle 35
OTDC320U11 1SCA130986R1001 DC disconnect switch 19
OHGS1RH 1SCA105264R1001 Handle 35
OTDC320U22 1SCA131006R1001 DC disconnect switch 23
OHGS2PJ 1SCA105268R1001 Handle 35
OTDC320US22 1SCA131032R1001 DC disconnect switch 23
OHGS3PH 1SCA105272R1001 Handle 35
OTDC32F2 1SCA121456R1001 DC switch-disconnector 12
OHGS3RH 1SCA105273R1001 Handle 35
OTDC32F2 1SCA121456R1001 DC switch-disconnector 12
OHRS3 1SCA108667R1001 Handle knob 34
OTDC32F3 1SCA121459R1001 DC switch-disconnector 12
OHRS3/1 1SCA108688R1001 Handle knob 34
OTDC32F4 1SCA121463R1001 DC switch-disconnector 12
OHSS1PH 1SCA105276R1001 Handle 35
OTDC32U4 1SCA136703R1001 DC switch-disconnector 13
OHSS1RH 1SCA105277R1001 Handle 35
OTDC32US4 1SCA136704R1001 DC switch-disconnector 13
OHSS2PJ 1SCA105280R1001 Handle 35
OTDC400E22 1SCA131036R1001 DC switch-disconnector 22
OHSS3PH 1SCA105285R1001 Handle 35
OTDC400E33 1SCA137231R1001 DC switch-disconnector 26
OHSS3RH 1SCA105286R1001 Handle 35
OTDC400U11 1SCA130990R1001 DC disconnect switch 19
OHY125J12 1SCA022381R1720 Handle 38
OTDC400U22 1SCA131010R1001 DC disconnect switch 23
OHY65J6 1SCA022380R9820 Handle 38
OTDC400US22 1SCA132300R1001 DC disconnect switch 23
OHY65J6T 1SCA022456R9540 Handle 38
OTDC500E22 1SCA132142R1001 DC switch-disconnector 22
OHY80J6 1SCA022381R0410 Handle 38
OTDC600UPP22 1SCA137207R1001 DC disconnect switch 19
OHY95J12 1SCA022381R1050 Handle 38
OTDC600USPP22 1SCA137213R1001 DC disconnect switch 19
OHY95J12T 1SCA022736R1910 Handle 38
OTDCKIT400B101 1SCA136283R1001 Short circuit and connection bar kits 43
OHYS1PH 1SCA105294R1001 Handle 35
OTDCKIT400B11 1SCA136282R1001 Short circuit and connection bar kits 43
OHYS1RH 1SCA105295R1001 Handle 35
OTDCKIT400B111 1SCA136284R1001 Short circuit and connection bar kits 43
OHYS2PJ 1SCA105322R1001 Handle 35
OTDCKIT400B202 1SCA136285R1001 Short circuit and connection bar kits 43
OHYS3PH 1SCA105327R1001 Handle 35
OTDCKIT400S101 1SCA136280R1001 Short circuit and connection bar kits 43
OHYS3RH 1SCA105328R1001 Handle 35
OTDCKIT400S11 1SCA136281R1001 Short circuit and connection bar kits 43
OTDC100E02 1SCA125822R1001 DC switch-disconnector 18
OTDCP16S12M 1SCA125153R1001 DC plastic enclosed 16
OTDC100E22 1SCA125824R1001 DC switch-disconnector 22 switch-disconnector
OTDC100U22 1SCA126180R1001 DC disconnect switch 23
OTDCP16S22M 1SCA125095R1001 DC plastic enclosed 16
OTDC100US22 1SCA126181R1001 DC disconnect switch 23 switch-disconnector
OTDC160E02 1SCA125840R1001 DC switch-disconnector 18 OTDCP16S22MD 1SCA131730R1001 DC plastic enclosed 17
OTDC160E22 1SCA125844R1001 DC switch-disconnector 22 switch-disconnector

Switches for PV applications | Index 51


Index

Type Order number Description Page


OTDCP16SA12M 1SCA125150R1001 DC plastic enclosed 16
switch-disconnector
OTDCP16SA22M 1SCA125094R1001 DC plastic enclosed 16
switch-disconnector
OTDCP16SA22MD 1SCA131850R1001 DC plastic enclosed 17
switch-disconnector
OTDCP25S11M 1SCA125130R1001 DC plastic enclosed 16
switch-disconnector
OTDCP25S12M 1SCA125154R1001 DC plastic enclosed 16
switch-disconnector
OTDCP25S22M 1SCA125092R1001 DC plastic enclosed 16
switch-disconnector
OTDCP25S22MD 1SCA131731R1001 DC plastic enclosed 17
switch-disconnector
OTDCP25SA12M 1SCA125151R1001 DC plastic enclosed 16
switch-disconnector
OTDCP25SA22M 1SCA125091R1001 DC plastic enclosed 16
switch-disconnector
OTDCP25SA22MD 1SCA131851R1001 DC plastic enclosed 17
switch-disconnector
OTDCP32S11M 1SCA125131R1001 DC plastic enclosed 16
switch-disconnector
OTDCP32S12M 1SCA125155R1001 DC plastic enclosed 16
switch-disconnector
OTDCP32S22M 1SCA125093R1001 DC plastic enclosed 16
switch-disconnector
OTDCP32S22MD 1SCA131732R1001 DC plastic enclosed 17
switch-disconnector
OTDCP32SA12M 1SCA125152R1001 DC plastic enclosed 16
switch-disconnector
OTDCP32SA22M 1SCA125090R1001 DC plastic enclosed 16
switch-disconnector
OTDCP32SA22MD 1SCA131852R1001 DC plastic enclosed 17
switch-disconnector
OTDCS250G1S 1SCA125563R1001 Terminal shroud 44
OTDCS250G4B 1SCA136274R1001 Shrouds for short circuit links/ 44
connection bars
OTDCS250T1S 1SCA125580R1001 Terminal shroud 44
OTDCS400G1L 1SCA132362R1001 Terminal shroud 44
OTDCS400G1S 1SCA132361R1001 Terminal shroud 44
OTDCS400G2B 1SCA136273R1001 Shrouds for short circuit links/ 44
connection bars
OTDCS400T11L 1SCA136279R1001 Shrouds for short circuit links/ 44
connection bars
OTDCS400T1L 1SCA132364R1001 Terminal shroud 44
OTDCS400T1S 1SCA132363R1001 Terminal shroud 44
OTDCS400T2L 1SCA136275R1001 Shrouds for short circuit links/ 44
connection bars
OTDCS400T3L 1SCA136276R1001 Shrouds for short circuit links/ 44
connection bars
OXS6X105 1SCA108043R1001 Shaft 37
OXS6X120 1SCA101654R1001 Shaft 37
OXS6X130 1SCA101655R1001 Shaft 37
OXS6X160 1SCA101656R1001 Shaft 37
OXS6X180 1SCA101659R1001 Shaft 37
OXS6X250 1SCA101660R1001 Shaft 37

52 Index | Switches for PV applications


Notes

Switches for PV applications | Notes 53


Notes

54 Notes | Switches for PV applications


Contact us

ABB Oy The technical data and dimensions are valid at the time of

Catalogue OTDC1GB 14-10 1SCC301021C0201


printing. We reserve the right to subsequent alterations.
Breakers and Switches
P.O. Box 622
FI-65101 Vaasa, Finland
Phone: +358 10 22 11
Fax: +358 10 22 45708
E-Mail: firstname.surname@fi.abb.com

www.abb.com

Vous aimerez peut-être aussi