Instruction Manual
Preface
This manual describes the operation of the LY-950 Slurry Sampler HII, LY-9507-XXHII.
Be sure to read this manual before using the product to ensure proper and safe operation of
the instrument. Also safely store the manual so it is readily available whenever necessary.
Product specifications and appearance, as well as the contents of this manual are subject to
change without notice.
HORIBA SHALL NOT BE LIABLE FOR ANY DAMAGES RESULTING FROM ANY
MALFUNCTIONS OF THE PRODUCT, ANY ERASURE OF DATA, OR ANY OTHER USES
OF THE PRODUCT.
Trademarks
Generally, company names and brand names are either registered trademarks or trademarks
of the respective companies.
WARNING
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
Conformable Directive
This equipment conforms to the following directives and standards:
Directives: the EMC Directive 2004/108/EC, in accordance with Article 10 (1)
of the Directive
the Low Voltage Directive 2006/95/EC
Standards: [the EMC Directive]
EN61326:1997/A3:2003
(EMISSION: Class B, IMMUNITY Category: Industry
[the Low Voltage Directive] EN61010-1:2001
Installation Environment
This product is designed for the following environment:
Installation Categories II
Pollution degree 2
Your correct disposal of WEEE will contribute to reducing wasteful consumption of natural
resources and protecting human health and the environment from potential negative effects
caused by hazardous substances in products.
Symbols
WARNING
Be sure to check that the sample nozzle and robot arm are at the stage origin before turning the
power switch ON.
If the power switch is turned ON while they are not at the stage origin, the robot arm will return directly
to the stage origin and may hit and damage the instrument or operator around the LY-9507-XXHII.
In case that the power turns OFF during the operation of the LY-9507-XXHII, set the sample nozzle
and robot arm to the stage origin manually before turning the power switch ON again.
If the power switch is turned ON while they are not at the stage origin, the robot arm will return directly
to the stage origin and may hit and damage the instrument or operator around the LY-9507-XXHII.
Incorrect wiring can lead to an electrical shock. Be sure to ground all wiring.
CAUTION
This instrument is for water solvent sample only, but does not support organic solvent.
Keep off and avoid touching the robot arm during operation of the LY-9506HII, or your fingers may be
caught and injured.
Points of concern
Use of the equipment in a manner not specified by the manufacturer may impair the protection
provided by the equipment. And it may also reduce equipment performance.
Exercise the following precautions:
o HORIBA service engineer installs the LY-9507-XXHII. There is no installation work
performed by the customer.
o Do not remove or modify any of this devices internal parts.
o Do not use volatile dispersion medium near the LY-9507-XXHII, otherwise a spark from
the motor or other part may cause the dispersion medium to ignite. This device's
specifications are not explosion proof.
o When using a dangerous dispersion medium or sample, avoid leaks and drainage.
o For basic operation of the LA-950V2, refer to the instruction manual of the LA-950V2.
Reference
Tip
This indicates reference information.
1 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 NAMES OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1 OVERVIEW
1 OVERVIEW
1.1 Outline
The LY-9507-XXHII, LY-950 Slurry Sampler HII, enables full-automatic measurement of multiple
samples by the Scheduler program of LA-950 software with a preset sequence. LY-950 Slurry
Sampler HII collects the samples from different beakers (sampling containers) and delivers the
samples to the particle size distribution analyzer (LA-950) for subsequent measurement.
The maximum number of samples is defined 15, 30 or 60 by the specification of LY-9507-
XXHII. The sequence performs all processes of the measurement automatically.
2
1 OVERVIEW
15 30 60
Narrow needle
Sample needle Wide pipe without scoop
Wide pipe with scoop _
Mechanical stirrer only
Magnetic stirrer only _
Agitation method
Both mechanical and _ _
magnetic stirrers
3
2 NAMES OF PARTS
2 NAMES OF PARTS
The names of parts of LY-9507-XXHII are as shown below.
4
2 NAMES OF PARTS
Rinse station
To clean the rinse station, disconnect the rinse liquid hoses and remove the two thumb screws
as shown on the picture.
Injector
5
3 ACCESSORIES
3 ACCESSORIES
Check that the following accessories are included with LY-9507-XXHII.
Table 1 Accessories
Item Quantity
Optional parts:
Magnetic stirrer (15 or 60 position) 1
Stirrer motor with 4 screws 1
Motor holder with 2 screws 1
Mechanical stirrer 1
Stirrer coupling with 2 set screws 1
6
4 OPERATION
4 OPERATION
WARNING
Be sure to check that the sample nozzle and robot arm are at the stage origin before turning the
power switch ON.
If the power switch is turned ON while they are not at the stage origin, the robot arm will return directly
to the stage origin and may hit and damage the instrument or operator around the LY-9507-XXHII.
In case that the power turns OFF during the operation of the LY-9507-XXHII, set the sample nozzle
and robot arm to the stage origin manually before turning the power switch ON again. In case that
the sample nozzle is inclined, set it vertically.
If the power switch is turned ON while they are not at the stage origin, the robot arm will return directly
to the stage origin and may hit and damage the instrument or operator around the LY-9507-XXHII.
CAUTION
Keep off and avoid touching the robot arm during operation of the LY-9506HII, or your fingers may be
caught and injured.
7
4 OPERATION
Operating procedure
Reference
For more information about the Scheduler program, refer to 2.11 Sampler Menu of the online help for
LA-950V2 .
7. Select a default condition file and method/sequence file from the drop down list
boxes.
8. For each sample which is installed in the sample slot, enter a sample name and a
sample position number.
9. Enter a filename.
10. In case of applying different condition file or method/sequence file to a particular
sample, click the subject file name.
11. Repeat steps 8. through 10. for all samples.
12. Make sure that each sample to be measured has the information on five columns
from the left of the window (Sample Name, Position, File Name, Conditions,
Method/Sequence).
The software will stop operation if any column is blank.
13. Make sure that no one is close to the LY-9507-XXHII, especially the robot arm.
14. Click the [Execute] button to start the operation of the LY-9507-XXHII.
8
5 MAINTENANCE
5 MAINTENANCE
Cleaning the slurry sampler
Prepare clean sample containers which are rinsed thoroughly. To prevent foreign matters
from getting into the sample, clean the sample needle as well.
When needle with scoop or the stirrer are installed, clean the sampling needle by using
the rinse station after each measurement. Depending on the sample type, additional
cleaning of the sample containers or the stirrer may be required before starting
measurement of each container.
If the rinse station is not connected to continuous flow fluid system, the rinse container
should be emptied, cleaned thoroughly and refilled before starting the measurement of
each container.
Magnetic Stirrer
To clean magnetic stirrer plate, wipe it with a dry cloth. If necessary, wipe it with a cloth
with mild detergent first.
As for the magnetic stir bars, clean them thoroughly after measurement of each
container. If necessary, clean it by using a blush with mild detergent to prevent
remaining the sample.
9
6 SPECIFICATIONS
6 SPECIFICATIONS
Sample applications Water-based slurry dispersions and emulsions
Communication RS-232C
Sample container: Glass
Peristaltic pump tube: Silicone rubber
Materials of surfaces in
contact with liquids Sample nozzle: SUS304 steel
Agitation propeller and shaft: SUS304 steel
Rinse station: Vinyl chloride polymer
10
2 Miyanohigashi, Kisshoin Minami-ku, Kyoto 601-8510 Japan
http://www.horiba.com