Carrier VRF Products Line UP
VRF Inverter (series K)
12HP
14HP
Compressor Inverter + Fix Speed Inverter + Inverter
N/A
Fan DC + AC DC + DC
16HP
18HP
20HP
24HP
8
High Efficiency DC inverter compressor
Excellent Performance
First on-indoor
Lock Heating
unit priority
mode
mode
Rotating electric
control box
Easy access
IDU installed in different MS box can run in different mode (IDU 1 - 6),
IDU installed in the same MS box can run in different mode (IDU 3, 4, 5, 6),
IDU installed in the same port/group will run in the same mode (IDU 3.1-3.4, 6.1-6.4)
C H OFF C OFF H
Blue fin.
Easy Installation and Maintenance
Optional ESP
0 20 Pa Default Changeable E.S.P.
20 60* Pa Customized
The outdoor unit will automatically distribute the addresses to indoor units
without any manual settings.
Wireless controller can enquiry and modify every indoor units address.
Inspection window
Check window (no need to take out the control box panel) :
Error check,
Test running,
Fix address setting,
Maintenance.
Only one communication wire (P,Q,E) for both communication of IDU, ODU &
network.
Central controller can be connected through IDU or ODU (X,Y,E terminals).
X,Y,E
X,Y,E
P ,Q, E
P ,Q, E P ,Q, E
P ,Q, E P ,Q, E
High Comfort
IDU Connectivity
Flexible installation
Joint
Cassette type
Duct type
Wall type
WL-12-CM WL-14-CM
Function WL-14-CM WL-12-CM
Temperature range 17 ~ 30 17 ~ 30
Time display
Key 26
Controller lock
Eco operation
Swing function
Background-light
Daily timer
Address setting
Fan speed control
Mode selection
Follow me function
standard optional
Individual Wired Controls
WR-10-CM
WR-12-CM
CRF-10-CM
Features
Easy installation & connection through IDU or ODU,
Up to 64 IDU, group control or individual setting,
Individual remote control restriction,
Mode lock,
Recovering all settings after power lose,
WCRF-10-CM
Features
Weekly schedule setting,
Up to 64 IDU group control or individual setting,
LCD screen backlight,
Temperature setting,
Individual remote control restriction,
Sleep and Silent mode,
Mode lock,
Recovering all settings after power lose.
Central Outdoor Wired Control
CRC-10-CM
Features
Up to 8 systems or 32 outdoor units,
Operating parameters,
Error codes of outdoor units,
RS485 communication.
Accessories
Feature:
AC internet access,
Connection through IDU,
Control up to 64 indoor units,
Real time control,
No distance restriction.
Accessories
Features
AC Control via Internet,
Up to 256 indoor units,
Up to 64 outdoor units,
16 systems per M Interface,
4 M-Interface per PC,
Features of IMM software
ex. Upper and lower limit temperature setting: Start / stop control,
Features
ODU consumption measured through Power Meter & send to M-Interface,
IDU consumption & capacity requirement measured through M-Interface,
Energy rated by the ODU to each IDU,
Consumption per tenant charged via M-Interface.
Features of IMM software
3 operation levels
protected via password Able to import AutoCAD
drawing or picture,
Service
Administrator
Emergency Stop
SMS warning message
Alarm signal output
Message warning
Please note: the message alarm function will generate extra cost;
this fee will be charged by the communication service operators.
SMS device state: Has been connected
OK Reset 12345
Features of IMM software
NW-BCN-CM NW-LNW-CM
Modbus gateway
BACnet gateway LonWorks gateway