HOT MIX ASPHALTIC CONCRETE TYPE "C" OR "D", TX-DOT ITEM 340

12"(30cm) CHANNEL 6.0' #4 BARS @ 16" O.C.B.W.


4"(10cm) INSTALLATION
2"
DETAIL
'
6"
6" 9.0 TX-DOT ITEM 247, TYPE A,
(15cm) 4"(10cm)
(15cm) 1. Prepare soil before installing rolled SEE DTL. GRADE 1-2 FLEXIBLE BASE
erosion control products (RECPs), FLEX. 9.5"
including any necessary application of BASE
lime, fertilizer, and seed.
5 2 7 2. Begin at the top of the channel by
anchoring the RECPs in a 6"(15cm) SUBGRADE
6" deep X 6"(15cm) wide trench with
(15cm) approximately 12"(30cm) of RECPs
2"-5" extended beyond the up-slope portion
(5-12.5cm) of the trench. Use ShoreMax mat at the 5'-0" TYPICAL PAVEMENT SECTION
channel/culvert outlet as supplemental

9"
scour protection as needed. Anchor the
RECPs with a row of staples/stakes
approximately 12"(30cm) apart in the 3"-5" NOMINAL DIAMETER ROCK 100,000 ESALs
4"-6" bottom of the trench. Backfill and CONCRETE/ASPHALT PAVEMENT JUNCTURE DETAIL
(10-15cm) 3 compact the trench after stapling. Apply
seed to the compacted soil and fold the
03 N.T.S. HMAC TYPE
"C" OR "D"
FLEX BASE SUBGRADE
3"x3" GALVANIZED WIRE MESH
6 remaining 12"(30cm) portion of RECPs
NOTE: N/A
back over the seed and compacted soil. OPTION #1 1 21" 10"
Secure RECPs over compacted soil ROCK GABIONS SHALL BE CONSTRUCTED AND
with a row of staples/stakes spaced INSTALLED PER TXDOT STANDARD SPECIFICATIONS OPTION #2 2 8 21" N/A
approximately 12" apart across the ITEM 459 CONTRACTOR TO ENSURE
4 width of the RECPs. SMOOTH TRANSITION OPTION #3 2 21" 7" N/A
3. Roll center RECPs in direction of water
flow in bottom of channel. RECPs will
unroll with appropriate side against the
soil surface. All RECPs must be
02 COMMON
N.T.S.
STONE RIPRAP GABION MATTRESS DETAIL PROPOSED HOT MIX
ASPHALTIC CONCRETE
18"
EXISTING HOT MIX
ASPHALTIC CONCRETE
NOTES:
1 securely fastened to soil surface by 1. CONTRACTOR TO VERIFY SUBGRADE CONDITIONS AND SELECT REVISIONS:
placing staples/stakes in appropriate
18" APPROPRIATE SECTION AS NECESSARY.
locations as shown in the staple pattern 2. CONTRACTOR SHALL REFERENCE THE FINAL GEO-TECHNICAL

VARIES
guide. 1/4" R 1/4" R REPORT AS PREPARED BY PROFESSIONAL SERVICES INDUSTRIES,
4. Place consecutive RECPs end-over-end PAVEMENT
6" (Shingle style) with a 4"-6" overlap. Use INC, PSI PROJECT # 0312-1390, DATED OCTOBER 19, 2016
(15cm) a double row of staples staggered 4" 3. PROPOSED ROAD IS CLASSIFIED AS LOCAL "A".
apart and 4" on center to secure 4" TOPSOIL
RECPs. 6" PROPOSED SUBGRADE EXISTING SUBGRADE
06 TYPICAL PAVEMENT SECTION DETAIL
5. Full length edge of RECPs at top of side
8 slopes must be anchored with a row of BACKFILL
staples/stakes approximately 12"(30cm) N.T.S.
apart in a 6"(15cm) deep X 6"(15cm)
CRITICAL POINTS
wide trench. Backfill and compact the EXISTING HEADER CURB
NOTES: trench after stapling. #4 BAR
A. Overlaps and Seams *Horizontal staple spacing should be 6. Adjacent RECPs must be overlapped CONTINUOUS
B. Projected Water Line altered if necessary to allow staples to approximately 2"-5" (5-12.5cm)
C. Channel Bottom/Side Slope Vertices secure the critical points along the channel
surface.
(Depending on RECPs type) and
stapled. 04 RIBBON
N.T.S.
CURB DETAIL 05 MATCH
N.T.S.
EXISTING PAVEMENT DETAIL
A A 7. In high flow channel applications a
B B staple check slot is recommended at 30
C C **In loose soil conditions, the use of staple to 40 foot (9 -12m) intervals. Use a
or stake lengths greater than 6"(15cm) may double row of staples staggered
be necessary to properly secure the 4"(10cm) apart and 4"(10cm) on center PL
RECP's. over entire width of the channel. 50' WIDTH
Drawing Not To Scale 8. The terminal end of the RECPs must be
anchored with a row of staples/stakes
Disclaimer: approximately 12" (30cm) apart in a 14.5' 21' PAVING 14.5'
The information presented herein is general design information only. For specific applications, 6"(15cm) deep X 6"(15cm) wide trench.
Backfill and compact the trench after
consult an independent professional for further design guidance. EXISTING
stapling. 4' 18" 10.5" 10.5" 18" 4'
5401 St. Wendel - Cynthiana Rd. PH: 800-772-2040 GROUND
Poseyville, IN 47633 www.tensarnagreen.com Drawn on: 3-16-11 3:1 MAX
1/4":1' MIN
1":1' MAX 2% 1/4":1' MIN
1":1' MAX

01 PERMANENT
N.T.S.
TURF REINFORCEMENT MAT EROSION CONTROL BLANKET DETAIL 3:1 MA
X

IMPROVED SHOULDER
8" CRUSHED LIMESTONE BASE
COMPACTED TO 95% DENSITY 2" (220# / S.Y.) ASPHALT
PAVEMENT TYPE "D" WITH
PRIME & TRACK COAT

IMPROVED SHOULDER
SUBGRADE TO BE EXISTING STRATUM II 8" CRUSHED LIMESTONE BASE
VARIES (LIMESTONE ROCK) OR CRUSHED 8" CRUSHED LIMESTONE BASE COMPACTED TO 95% DENSITY
LIMESTONE BASE PLACED IN 6" COMPACTED TO 95% DENSITY
2' COMPACTED LIFTS OR EQUIVALENT

PROPOSED GRADE
** * * DIAMETER OF PIPE + 1'-0" (MIN)
* * * 18" UPSTREAM
07 TYPICAL
N.T.S.
STREET SECTION DETAIL (50' PRIVATE)
24" DOWNSTREAM
6.0'

3 MIN.
1
4"

CULVERT
CL
6" X 6" NO. 6 WIRE MESH

ANAQUA SPRINGS RANCH UNIT 7


STREET AND DRAINAGE DETAILS
3' 3'
4"
UPSTREAM CLASS A CONCRETE
***

N.T.S.
8"

BEXAR COUNTY, TEXAS


1'-0" 1'-0" 1'-0" 1'-0"
MIN. MIN. MIN. MIN.

FOR
VARIES
2'
PROPOSED GRADE
** * * DIAMETER OF PIPE + 1'-0" (MIN)
END VIEW * * * 18" UPSTREAM
N.T.S. 24" DOWNSTREAM
6.0'

3 MIN. PROPOSED
1 BAFFLE BLOCKS
4"

CULVERT 1.0'
CL 1.5'
6" X 6" NO. 6 WIRE MESH

4"
DOWNSTREAM CLASS A CONCRETE
***

N.T.S.
8"

08 CONCRETE
N.T.S.
PIPE END TREATMENT
CG501
JOB NO. SCHOOL
DESIGNED BY: XV
DRAWN BY: XV
G:\21 - Anaqua Springs Unit 7\C\10 STREET AND DRAINAGE DETAILS (SHEET 2).dwg CHECKED BY: AA
Date: Apr 24, 2017, 7:23pm User ID: xvasquez SHEET # 9 OF 13