1 Fisher
Type 627R
Last capacity figure in each group indicates maximum allowable inlet pressure (except
for emergency conditions).
Heavy stepped line indicates the recommended maximum capacity and inlet pressure
for each orifice for operation within the optimum performance range.
CLASS 250
Allowable working pressures
for these fittings are:
250 psi Working Steam pressure (W.S.P.)
400 psi Water, Cold Oil or Gas (W.O.G.)
OGA Seminar 2012 15
Malleable Iron Threaded Fittings
Classes 150 and 300
CLASS 150
Allowable working pressures
for these fittings are:
150 psi Working Steam pressure (W.S.P.)
300 psi Water, Cold Oil or Gas (W.O.G.)
CLASS 300
Allowable working pressures
for these fittings are:
PRESSUE TEMPERATURE TABLE
FOR CLASS 300
Non-shock
PIPE SIZE W .S.P, Or hot oil
cold W .O.G.
in inches up to 550 O F
To 150 O F
1/8 to 1 300 psi 2000 psi
1 1/4 to 2 300 psi 1500 psi
2 1/2 to 4 300 psi 1000 psi
5 to 8 300 psi 800 psi
OGA Seminar 2012 16
Forged Fittings
Classes 2000, 3000, 6000 AND 9000
90o ELBOW 45o ELBOW TEE CROSS STREET ELBOW LATERAL
www.onlinepipe.com
OGA Seminar 2012 17
ASME B16.1
ANSI CLASS
Sight gauges
Dump valves