Column Element Details Type: Ordinary Frame (Flexural Details)

Level Element Unique Name Section ID Combo ID Station Loc Length (mm) LLRF
L-3RD FLOOR C51 404 C-600X600M45 DCON30 1500 1500 1

Section Properties
b (mm) h (mm) dc (mm) Cover (Torsion) (mm)
600 600 58 30

Material Properties
Ec (MPa) fck (MPa) Lt.Wt Factor (Unitless) fy (MPa) fys (MPa)
33541.02 45 1 500 415

Design Code Parameters


C S
1.5 1.15

Axial Force and Biaxial Moment Design For Pu , Mu2 , Mu3


Design Pu Design Mu2 Design Mu3 Minimum M2 Minimum M3 Rebar Area Rebar %
kN kN-m kN-m kN-m kN-m mm %
6576.53 -543.2306 -151.2601 151.2601 151.2601 5729 1.59

Factored & Minimum Biaxial Moments


NonSway Mns Sway Ms Factored Mu
kN-m kN-m kN-m
Major Bending(Mu3 ) -104.5743 -19.1763 -123.7506
Minor Bending(Mu2 ) -155.1957 -388.0349 -543.2306

Slenderness Effects (IS 39.7.1) and Minimum Biaxial Moments (IS 39.2, 25.4)
End Moment End Moment Initial k*Ma Minimum Minimum
Mu1 (kN-m) Mu2 (kN-m) Moment (kN-m) Moment (kN-m) Moment (kN-m) Eccentricity (mm)
Major Bending (M3 ) 0.1558 -123.7506 -74.188 0 151.2601 23
Minor Bending (M2 ) 47.8852 -543.2306 -306.7843 0 151.2601 23

Effective Length Factors (IS 25.2, Annex E)


K K Framing P-Delta Q K
Sway Non-Sway Type Done? Factor Used
Major Bend(M3 ) 1 1 Ordinary Frame Yes 0.013658 1
Minor Bend(M2 ) 1 1 Ordinary Frame Yes 0.032385 1

Additional Moment Reduction Factor k (IS 39.7.1.1)


Ag Asc Puz Pb Pu k
cm cm kN kN kN Unitless
3600 57.3 9438.23 3409.1 6576.53 0.474646
Additional Moment (IS 39.7.1)
Consider Length Section KL/Depth KL/Depth KL/Depth Ma
Ma Factor Depth (mm) Ratio Limit Exceeded Moment (kN-m)
Major Bending (M3 ) Yes 1 600 2.5 12 No 0
Minor Bending (M2 ) Yes 1 600 2.5 12 No 0