Vous êtes sur la page 1sur 2

Code: C01

Description:
Main motor abnormality: The main motor is not rotatingnormally.
Code: C04
Description:
PFP motor abnormality: The PFP motor is not rotatingnormally.
Code: C08
Description:
ADU motor IC overcurrent detection error
Code: C15
Description:
PFP upper drawer tray abnormality: The PFP upperdrawer tray-up motor is not rota
ting or the PFP upper drawer tray is not moving normally.
Code: C16
Description:
PFP lower drawer tray abnormality: The PFP lowerdrawer tray-up motor is not rota
ting or the PFP lower drawer tray is not moving normally.
Code: C21
Description:
CIS unit initialization error
Code: C26
Description:
Peak detection error / FPGA configuration error: Lightingof the exposure lamp (w
hite reference) is not detected when power is turned ON.

Code: C41
Description:
Thermistor or heater abnormality at power-ON:Abnormality of service call the the
rmistor is detected when power is turned ON or the temperature of the fuserrolle
r does not rise in a specified period of time afterpower is turned ON.
Code: C43
Description:
Thermistor abnormality during warming up or in readystatus after abnormality jud
gment
Code: C44
Description:
Heater abnormality after abnormality judgment: Thetemperature of the fuser rolle
r has exceeded the range of control (in this case, the main switch turns OFF aut
omatically) or does not even reach the range.
Code: C45
Description:
Thermistor abnormality during printing: Abnormality of thethermistor is detected
during printing.
Code: C55
Description:
ADF I/F error: Communication error has occurredbetween the ADF and the scanner
Code: C56
Description:
PFC board I/F error: Communication error has occurredbetween the PFC board and t
he equipment.
Code: C94
Description:
Firmware update error: An error message appears wheneither of the following Main
PC boards is installed to e- STUDIO185/225/2
Code: C97
Description:
High-voltage transformer abnormality: Leakage of themain charger is detected.
Code: C99
Description:
PFC microcomputer abnormality
Code: CA1
Description:
Polygonal motor abnormality: The polygonal motor is notrotating normally.
Code: CA2
Description:
H-Sync detection error: H-Sync detection PC boardcannot detect laser beams.
Code: F14
Description:
Invalid backup counter: The value of the total counter isinconsistent with that
of the backup counter.45.- The Main PC board for e-STUDIO182- The Main PC board
for e-