SCHEDULE OF FINISHES

Walls
Footings 230x600mm in medium strength concrete to NBR standard and SANS
10400. Walls are built with 90mm bricks - heights as per plan. External walls to
plastered and painted with 50mm cavity between internal and external skins with 2.5
butterfly wire ties per square meter. All internal walls plastered with lime cement.
Brickforce in 4 layers over all openings, with precast concrete lintels to openings
26.5 greater than one metre.
ROOF PITCH

1,968
Window-sills
300 300 External & Internal, smooth finished cement plaster.

Roof Construction

4,518
Cement roof tiles @ 26.5 pitch on 38x38 SAP battens at maximum 320 centres on
DPC prefabricated gangnail trusses at maximum 760 c/c, fixed to 114x38 wallplates and
anchored to brickwork with 30x2mmx1m hoop iron ties, built into walls for minimum of
600mm. SABS approved underlay to tiled roof. All roof timber to be minimum Grade

2,550
PLASTER & PAINT 5 SA Pine TAN treated. All gable ends to be tied with hoop iron built into wall for
NGL minimum 600mm and up to two trusses away from gable to SANS 10400-L where
FRONT ELEVATION 1 applicable. Bracing as per A19 Engineer.
SCALE 1:100
Eaves
BATHRM BEDRM 300mm Open eaves overhang with 225mmx10mm painted fibre cement fascias.
DPC DPC
250mic DPM
400x200 375mic DPM UNDER ALL WALLS Rainwater Disposal
THICKENED MINIMUM 150mm ABOVE FGL Alu. gutters with 75mm PVC downpipes as per plan.
FOUNDATION
600x230 600x230
SECTION A-A Ceilings
25mm Isoboard EPS ceiling on 38 x 38 SA Pine battens at 300mm spacing and 76mm
SCALE 1:100
3 Rhino cornice with 155mm thick flexible polyester blanket(Isotherm).

Floors
7,200 Finished as per plan and/or client choice/building tender, on 25mm screed, on 80mm
230 90 230 concrete for ground storey, (as above) on 250 micron waterproof sheeting, on
3,580 3,070 compacted filling and sand blinding. All floor levels to be a minimum of 150mm
230 90 90 230 above FGL.
2,590 900 3,070
Doors & Windows
230

230

230
Windows top-hung aluminium, as per plan codes & elevations.
Note : Safety glass to window panes larger than 1sq.m or closer than 500mm from

1,165
ELEVATION 2
1,400

FFL to SANS 10137 and to comply to SANS 10400-N.


BEDRM 2
B.I.C

SCALE 1:100
1,800

1,800
B.I.C

BEDRM 1
(Carpet)

(900x1100)
(Carpet) Drainage
110mm Smooth uPVC Sewer pipe with minimum 1:60 fall with IL at minimum
(1200x1200)

2,800
900
W6
3,220

450mm. 50mm 2way vent valve on start of one pipe sewer system. All sewer lines
1,200

W2

passing under structure to comply to SANS 10400-PP24 (encase in sand or


90

90
concrete). All drainage to comply to SANS 10400-P.

Electricals - as per building tender.


1,925

Position of Oostersee Electrical connection box on exterior wall to be determined on


1,240

90 site.
90

BEDRM 3
EN-SUITE
(600x900)

(Carpet) NOTES:
1,200

(900x1100)

(Tiles) Figured dimensions takes preference to scaled dimensions.


600

W3

2,700

All relevant levels and dimensions to be verified on site prior to construction.


900
W6

All work to comply to NBR, Local Bylaws and Municipal Regulations.


HWC IN
770
90

B.I.C
ROOF

BATH RM All levels to be determined on site and can/may be to adjusted to the descrepancy
10,680

10,680
(900x900)

(Tiles) PLASTER & PAINT of the developer and his appointed builder. Developer to approve plan prior to
2 A A
1,660

900

W5

submission to council.
7,630
90

All glazing to SANS 10137 & SANS 10400-N. Printed dimensions take prference over
ELEVATION 3
2,525

TV 4 SCALE 1:100
scaled dimensions. All work to be carried out in strict accordence to NBR and local
bylaws.
90

1,910

Finishes in builders contract takes preference over finishes specified on plan.


LOUNGE In case of discrepances the author of the plan should be contacted before
(Tiles) proceeding with any construction.
(1500x1500)
3,170

1,500

4,540
W1
900

KITCHEN
(Tiles)
1,060

WM
230 470 230

PD26
1,765
230

W6
700

(900x1100)
230

W6
PLASTER & PAINT
(900x1100)
37 VAN DER STEL STREET P.O. BOX 1399 TEL: 021 906 6770
1,005 900 1,005 900 1,245 900 1,245
KUILSRIVER KUILSRIVER FAX: 021 906 6775
ELEVATION 4 7579 7580 EMAIL : nationhousing@mweb.co.za
230 90 230 SCALE 1:100
2,590 4,060
230 230 230
ELECTRICAL HOUSE PLAN- Type 7-75 sq.m DATE : Aug 2016
900 2,930 SANS 10400-XA TELEPHONE POINT
PROPOSED NEW DWELLING DRAWING : Type 7-75 sq.m
7,200 HWC DETAILS: CEILING LIGHT POINT
PIPING 15mm AND 22mm CLASS 1 FOR .......... ON ERF ...... , PROJECT MONTCLAIR
:NATION HOUSING
COPPER TUBE WATERPROOF LIGHT POINT
FLOOR PLAN
SCALE 1:100 1 HWC KWIKOT ECONO STD GALV. 150L
GEYSER.
15 AMP PLUG POINT
MONTCLAIR SCALE : 1:100
LAGGING (R=1) ON ALL EXPOSED 15 AMP UNDERCOUNTER
AREA HOUSE : 75sq.m PIPES MOUNT PLUG POINT

W1= 1.5x1.5 = 2.25 sq.m 15 AMP PLUG POINT 2000mm HIGH


1200mm HIGH PC WALL WALLS EXT. 230 CAVITY W2 = 1.2x1.2 = 1.44 sq.m
W3 = 0.6 x 0.9 = 0.54 sq.m DISTRIBUTION BOARD
BUILDING LINES INT. 90 x 190 mm
W5 = 0.9 x 0.9 = 0.81 sq.m TV TV POINT
RAINWATER CHANNEL NOTE: W6= (0.9x1.1) x 3 = 2.97 sq.m
RAINWATER D.P. DP TOTAL =8.01 sq.m
FFL ABOVE NGL TO BE FLOOR AREA : 68 sq.m STOVE CONNECTION
110mm PVC SEWER DETERMINED ON SITE. FENESTRATION PERCENTAGE :
AT 1:40 GRADIENT MINIMUM 150mm. 11.78% BALL FITTINGS TO ALL LIGHT POINTS