BANCOS DE CARGA
RELIABILITY SERVICE VALUE QUALITY RELIABILITY
Fp = KW Generador 4 cond. Estrella Banco de carga 3 cond en delta
SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
KVA IL
A QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILIT
KVAR = KVA - KW
2 2
Los KW nominales del grupo motor-gene Neutral QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILI
VL-L
Avtron Loadbank, Inc. Bancos de Carga Avtron Bancos de Carga para Media Tensin
Desde 1953, Avtron ha sido lder en el Los bancos de carga son dispositivos di Avtron es lder en la fabricacin de verdade
diseo y manufactura de productos de alta seados para proporcionar cargas elctricas ros bancos de carga para voltajes de media
calidad y confiabilidad, dirigidos a las ms que sirven para probar fuentes de potencia tensin.
exigentes aplicaciones industriales. Los pro tales como generadores y Fuentes de Poder Estas unidades operan con la salida regular
ductos Avtron incluyen: Ininterrumpible (UPS en ingls). Los ban de voltaje de los generadores por lo que no
Bancos de Carga Resistivos y cos de carga son usados igualmente para requieren de transformadores para bajarlo.
Reactivos reducir problemas de carbonizacin en
motores diesel de sistemas de generacin Un mdulo tpico brinda una capacidad para
Resistencias Industriales 4 a 6 megawatts y cuando el requerimiento
Equipos de Prueba para sistemas de emergencia.
es mayor a decenas o centenas de mega
elctricos de Aeronaves La mayora de los bancos de carga resisti watts, entonces se utilizan varios mdulos.
Equipos de Instrumentacin Digital vos de Avtron poseen elementos resistores Por lo general los voltajes van de un rango
Sistemas de Control Digital Helidyne. Estos componentes diseados de 5 a 15 KV.
Avtron est 100% comprometido en man y fabricados por Avtron, estn elaborados El modelo K922A (izquierda) es uno de los Econmico Sistema de bancos de carga de
Los elementos Helidyne de Avtron se Sin embargo, si el cliente lo requiere, se les
tener los altos estdares que los clientes con una aleacin de cromo resistente a la encuentran totalmente reforzados y operan a varios tipos de mdulos de media tensin media tensin, montado en base deslizante
corrosin y se encuentran asegurados por puede suministrar el voltaje que necesite. usados por fbricas con grandes turbinas para disponible de 750 a 2000 KW (modelo K875A-
esperan en cuanto a: Diseo, Manufactura y bajas temperaturas para mayor durabilidad.
medio de varillas de acero inoxidable con Hay disponibles tambin diseos de bancos pruebas de produccin. MV-mostrado arriba).
Soporte Tcnico de todos sus productos. de carga tipo convencional con transforma
segmentos aisladores de cermica. Todas las partes son cuidadosamente seleccionadas
Dcadas de amplia experiencia proporcio para operar a bajas temperaturas, a fin de proporcionar un mejor rendimiento y confiabilidad, dores para bajar el voltaje (modelo K875A-
nan a Avtron la capacidad de satisfacer eliminando con esto el uso de perodos de enfriamiento luego de operar los bancos de MV) montados en bases estructurales .
cualquier requerimiento en lo referente a carga.
diseos de bancos de carga. Avtron ofrece
as mismo, una lnea completa de bancos Aplicaciones
de carga prediseados, los cuales tienen
Los bancos de carga tienen un amplio rango de aplicaciones tales como:
Bancos de Carga Montados en Ductos y Radiadores
la ventaja de resultar ms econmicos y de
estar disponibles con mayor rapidez. Pruebas en fbrica de plantas generadoras Los bancos de carga Avtron Mod. K711 removibles para ductos a fin de facilitar
Reducir problemas de carbonizacin y K711A estn diseados para montarse la instalacin y montaje. Estos bancos de
Sistema de Calidad con Ejercicio peridico de plantas de emergencia en radiadores o ductos de motores diesel carga estn dimensionados por lo general
de plantas generadoras. Estos bancos de al 50-60% de la capacidad en KW del gene
Certificacin ISO 9001 Prueba de sistemas UPS
carga son de montaje fijo y se colocan rador o, para complementar la carga actual
Prueba de sistemas de bateras
El Sistema de Calidad de Avtron est cer Prueba de tierras en sistemas de potencia frente al generador del motor y estn dimen del generador y minimizar as los efectos de
tificado de acuerdo a la norma ISO 9001. Optimizacin de carga en aplicaciones de potencia primaria sionados para acoplarse a lo largo y ancho carbonizacin de los motores diesel.
Esto significa que los productos Avtron Prueba de turbinas en fbricas. del radiador o del ducto de salida. El banco Las capacidades nominales son de 8 a
cumplen consistentemente con las ms de carga utiliza el aire de enfriamiento del 1000 KW en voltajes de 208, 240, 480
Avtron fabrica tanto los bancos de cargas como el equipo auxiliar necesario para realizar
altas normas de la calidad. motor en lugar del ventilador interno de un VAC, 3 fases, 60 Hz.w
estas y otras aplicaciones. Para seleccionar el mejor sistema de banco de carga que su
banco convencional.
empresa requiere, contacte a un representante de ventas Avtron, quien le brindar un ade
Requerimientos NFPA cuado asesoramiento tcnico. Se suministra una brida de montaje supe
rior e inferior, o bien bridas de adaptacin
La Asociacin Nacional de Proteccin con
tra Incendios (NFPA en ingls), elabora nor Mejorar La Confiabilidad de Plantas Generadoras Banco de carga para montaje en radiador o
ducto de 10 1000 KW (modelo K711).
mas de prueba para Sistemas de Potencia Tanto las industrias comerciales como las manufactureras reconocen que un programa de
de reserva y emergencia, las cuales incluy mantenimiento preventivo es vital para que un generador de emergencia o de reserva opere
en la NFPA 70, la NFPA 99 y la NFPA 110. de forma confiable. Los Bancos de Carga vienen a ser una parte esencial de tales program
Estas normas sirven como guas para la
aceptacin de instalaciones de sistemas de
as., proporcionando medios prcticos para probar los sistemas de potencia sin necesidad de Resistores Avtron para Aterramiento de Neutros
interrumpir las cargas crticas.
potencia, para realizar pruebas peridicas y Los resistores Avtron para aterramiento de con falla a tierra (que son por lo general de
de mantenimiento; adems establece espe Las principales causas de que un motor diesel falle, es la carbonizacin (acumulacin de
combustible sin quemar en los pistones del motor) y esto ocurre cuando el generador opera neutros, estn diseados para brindar una 10.000 a 20.000 amps). Colocando un resis
cficamente las pruebas requeridas para mayor seguridad en los sistemas industri tor para aterramiento de neutros Avtron, se
sistemas de potencia utilizados en centros con una baja carga. Los motores diesel con muy baja carga o que operan en vaco por pero
dos prolongados, nunca alcanzan la temperatura recomendada de operacin. Con el tiempo, ales de distribucin, por medio de la limit limita la corriente de falla a un nivel seguro
de salud. Todas estas normas requieren que acin a niveles razonables de las corrientes (de entre 25 a 400 amps), mientras se
las pruebas de los sistemas de potencia de el combustible no quemado, cubre la cmara de combustin, reduciendo la capacidad nomi
nal, la eficiencia y la vida til del motor. Un programa de mantenimiento preventivo que incluya de falla a tierra. En un sistema tpico de 4 permite el suficiente flujo de corriente para
respaldo se realicen con cargas parciales o conductores con conexin slida a tierra, operar los relevadores de eliminacin de
totales utilizando equipos de carga. Los ban pruebas con carga de la planta generadora reducir los efectos dainos de la carbonizacin
e incrementar la vida til del motor. el neutro est directamente conectado a falla. Limitando la corriente de falla tambin
cos de carga Avtron proporcionan la capaci la tierra fsica. Esto puede causar serios se reduce el problema de picos transitorios
dad de carga necesaria para realizar todas
estas pruebas en sistemas de potencia de
Ventajas de La Construccin con Acero Aluminizado daos a los transformadores, motores, gen de voltaje ( de hasta 6 veces el voltaje nor
eradores, al cableado y a los equipos aso mal) que pueden ocurrir durante los arcos
emergencia y de respaldo, cumpliendo as Los Bancos de Carga convierten la energa elctrica en calor. Gran parte de este calor es ciados, debido a las corrientes muy altas de falla a tierra.
con los requerimientos de la NFPA. disipado gracias a un ventilador de enfriamiento. Sin embargo, el gabinete tiende a absorber
una porcin de este calor, por lo que debe ser construido con un material que soporte estos Resistor de Aterramiento de Neutros para
ambientes trmicos. Es por ello que los gabinetes de los Bancos de Carga Avtron, son cons 4160/2400 volts, 400 amps, 10 segundos.
truidos con acero aluminizado, material que ofrece una mejor y mayor proteccin contra el
calor y la corrosin que los aceros galvanizados comunes.
2 7
UALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
ELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY SERVIC
VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY VALUE QUALIT
RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE QUALITY RELIABILITY
ERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVIC
Nota: Los modelos mostrados estn disponibles en voltajes internacionales para 50/60 Hz y
Bancos de Carga Modelos Estandar diseos especiales en corriente directa. Para detalles ver la Gua de Comprador en 50 Hz o
la Gua Canadiense.
Reactivos
RESOLUCON DIMENSIN PESO
Los bancos de carga inductivos/reactivos TIPOS MODELO CAPACIDAD MIN. DE PASO VOLTAJE CARGA VOLTAJE VENTILADOR APROX. APROX.
DE CARGA (pulgades) (libras)
(KVAR) de Avtron son usados por lo general
en combinacin con bancos de carga K490 10 KW 0.25 KW 120 VAC; 120/240 VAC; 1 120 VAC; 1 18"L, 13"W, 11"H 35
resistivos (kW) para efectuar pruebas a 120/240 VAC; 1,
25-75 KW 0.5 KW or 1 KW
generadores o fuentes de poder con factor Liberty 240 VAC; 1 120 VAC; 1 23"L, 13"W, 24"H 75
de potencia de 0.8 (atraso). El banco de Banco Porttil 55 KW 5 KW 240/480 VAC; 3
carga reactivo debe ser dimensionado a Tipo Resistivo con
Panel de Control Freedom 100 KW/93.75 KW 5 KW 240/480 VAC; 3 120 VAC; 1 25"L, 16"W, 29"H 105
75% del valor en KW del banco de carga
Integrado para 200 KW 120 VAC; 1; 1HP 47"L, 34"W, 52"H 600
resistivo, para obtener un factor de potencia Interiores
de 0.8. Los bancos de carga resistivos y Banco de carga reactivo de gran capacidad Unidades instaladas de 375 KVAR (modelo K841) Millennium 250 KW 5 KW 240/480 VAC; 3 650
208-230/460 VAC; 3; 3 HP 56"L, 34"W, 52"H
reactivos se conectan y operan en paralelo. (modelo K841B) disponible de 375 a 1875 KVAR. Puede ser usado de manera individual o en para- 400 KW 800
lelo dependiendo de los requerimientos de carga.
Los modelos como el K841 y el K841B Patriot 500 or 700 KW 5 KW 240/480 VAC; 3 208-230/460 VAC; 3; 5 HP 61"L, 34"W, 75"H 1,200
poseen un rango que va desde 50 a 1875 K492 150 Amps DC 1 Amp 26/52 VDC 26/52 VDC or 120 VAC; 1 18"L, 13"W, 11"H 35
KVAR. Son diseos para instalacin fija Bancos DC
K576 500 Amps DC 2.5 Amps 52 VDC 120 VAC; 1; 0.25 HP 28"L, 24"W, 27"H 160
tanto en interiores como exteriores y vienen Porttiles
equipados con paneles de control para K571 1000 Amps DC 5 Amps 28 or 52 VDC 120 VAC; 1; 0.5 HP 28"L, 23"W, 63"H 295
operacin remota (de 19" para montaje Banco Resistivo K580 750 - 1250 KW 5 or 50 KW 240/480 VAC; 3 208-230/460 VAC; 3; 5 HP 208"L, 93"W, 84"H 4,000*
Banco de carga resis-
sobre rack o en gabinetes tipo NEMA). tivo/reactivo de alta para Exteriores
1500 - 2000 KW 188"L, 93"W, 118"H 6,000*
capacidad con base Montado en LTV 5 or 50 KW 480 VAC; 3 480 VAC; 3
Los bancos inductivos/reactivos de Avtron 2500 - 3000 KW 208"L, 93"W, 118"H 7,500*
metlica (modelo LPS) Remolque
contienen reactores de carga monofsi
cos y trifsicos con ncleos de hierro no Disponible de 1875 a
Banco Resistivo/
2500 KVAR. 2000 KW; 1500 KVAR 50 KW; 37.5 KVAR
saturados. Reactivo para
LPS or or 480 VAC; 3 480 VAC; 3 255"L, 76"W, 109"H 13,000
Exteriores Montado
Bancos de Carga en Base Metlica
1500 KW; 1125 KVAR 5 KW; 3.75 KVAR
KW montado en triler con carretes opcionales triler construido todo en acero inoxidable 2500 KW 5,000
50 KW 480 VAC; 3 (3) 10 HP; 460 VAC 120"L, 59"W, 156"H
El Controlador Remoto para cable. (modelo K580). 3000 KW 6,000
Porttil de Avtron viene 750 - 1000 KW (1) 10 HP; 460 VAC 165"L, 60"W, 148"H 10,000
incluido con la mayora K875A-MV
1500 - 2000 KW
5 or 50 KW 5 kV AC, 5 - 15 kV AC; 3
(2) 10 HP; 460 VAC 230"L, 60"W, 148"H 14,000
de los bancos de carga 3000 - 6000 KW 250, 500, or 5 kV AC; 3, 187"L, 102"W, 192"H 13,000 -
de alta capacidad K922A (4) to (8) 10 HP; 460 VAC
per module 1000 KW 5 - 15 kV AC; 3 (typical 4500 KW unit) 17,000
(LCV y LPS). Tambin 480 VAC; 3,
se puede adquirir de Banco para K841 150 to 375 KVAR 3.75 KVAR 120 VAC; 1 54"L, 52"W, 92"H 4,500
240/480 VAC; 3
forma opcional para los bancos de carga Paquete estndar 1250 Montaje Fijo Tipo
480 VAC; 3, 116"L, 66"W, 80"H 6,000 -
KW montado en triler Reactivo K841B 375 to 1875 KVAR 3.75 or 37.5 KVAR 120 VAC; 1
LTV y K580 montados en triler. 240/480 VAC; 3 144"L, 66"W, 80"H 10,000
con carretes opcionales
Este resistente, compacto y ligero equipo para cable (modelo Banco Resistivo/ 3000 KW/2250 KVAR
29,000 -
ha sido diseado para operarlo de forma K580). Reactivo para LCV 4000 KW/3000 KVAR 25 KW/18.75 KVAR 480 VAC; 3 460 VAC; 3; 10 HP x 3 or 6 240"L, 96"W, 108"H
37,000
fcil. Todos los controles del banco de carga Montar en Container 5000 KW/3750 KVAR
son activados presionando el teclado tipo
membrana. Las funciones del banco de Alimentacin del Control: Por lo general el tipo de potencia requerida Medicin Digital: El Sistema Avanzado de Monitoreo Digital Avtron
carga se muestran en la pantalla LCD con para operar un circuito de control es de 120 VAC, una fase, 60 Hz, sin (ADMS en ingls) es suministrado junto con la mayora de los Bancos
iluminacin posterior. De igual forma, el con embargo, si no tiene disponible dicho voltaje, podemos suministrarle un de Carga Porttiles de Avtron y de forma opcional para otros modelos. El
trolador posee un botn de parada de emer Gran paquete montado transformador monofsico de potencia para el control. Medidor Digital Multifuncional de Potencia, despliega medidas de voltaje,
en plataforma con Potencia para el Ventilador: Regularmente el suministro de potencia para corriente, frecuencia y potencia e incluye un software comunicador EXT
gencia cableado. La comunicacin entre el
banco de carga resis- los ventiladores se obtiene de una fuente externa. Avtron posee modelos de recoleccin de datos.
controlador y el PLC del banco de carga se
tivo/reactivo (modelo de Bancos de Carga que se surten con una derivacin para obtener de la Nota: Otros modelos con diferente KW/KVAR estn disponibles bajo
hace por medio de un cable de 200 pies y
LCV) y transformador planta en prueba esta potencia necesaria. pedido. Las especificaciones estn sujetas a cambios sin previo aviso.
un conector tipo MS. para bajar el voltaje.
* Incluye remolque.
6 3
UALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
ELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY SERVIC
VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY VALUE QUALIT
RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE QUALITY RELIABILITY
ERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVIC
4 5
UALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
ELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY SERVIC
VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY VALUE QUALIT
RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE QUALITY RELIABILITY
ERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVIC
4 5
UALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
ELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY SERVIC
VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY VALUE QUALIT
RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE QUALITY RELIABILITY
ERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVIC
Nota: Los modelos mostrados estn disponibles en voltajes internacionales para 50/60 Hz y
Bancos de Carga Modelos Estandar diseos especiales en corriente directa. Para detalles ver la Gua de Comprador en 50 Hz o
la Gua Canadiense.
Reactivos
RESOLUCON DIMENSIN PESO
Los bancos de carga inductivos/reactivos TIPOS MODELO CAPACIDAD MIN. DE PASO VOLTAJE CARGA VOLTAJE VENTILADOR APROX. APROX.
DE CARGA (pulgades) (libras)
(KVAR) de Avtron son usados por lo general
en combinacin con bancos de carga K490 10 KW 0.25 KW 120 VAC; 120/240 VAC; 1 120 VAC; 1 18"L, 13"W, 11"H 35
resistivos (kW) para efectuar pruebas a 120/240 VAC; 1,
25-75 KW 0.5 KW or 1 KW
generadores o fuentes de poder con factor Liberty 240 VAC; 1 120 VAC; 1 23"L, 13"W, 24"H 75
de potencia de 0.8 (atraso). El banco de Banco Porttil 55 KW 5 KW 240/480 VAC; 3
carga reactivo debe ser dimensionado a Tipo Resistivo con
Panel de Control Freedom 100 KW/93.75 KW 5 KW 240/480 VAC; 3 120 VAC; 1 25"L, 16"W, 29"H 105
75% del valor en KW del banco de carga
Integrado para 200 KW 120 VAC; 1; 1HP 47"L, 34"W, 52"H 600
resistivo, para obtener un factor de potencia Interiores
de 0.8. Los bancos de carga resistivos y Banco de carga reactivo de gran capacidad Unidades instaladas de 375 KVAR (modelo K841) Millennium 250 KW 5 KW 240/480 VAC; 3 650
208-230/460 VAC; 3; 3 HP 56"L, 34"W, 52"H
reactivos se conectan y operan en paralelo. (modelo K841B) disponible de 375 a 1875 KVAR. Puede ser usado de manera individual o en para- 400 KW 800
lelo dependiendo de los requerimientos de carga.
Los modelos como el K841 y el K841B Patriot 500 or 700 KW 5 KW 240/480 VAC; 3 208-230/460 VAC; 3; 5 HP 61"L, 34"W, 75"H 1,200
poseen un rango que va desde 50 a 1875 K492 150 Amps DC 1 Amp 26/52 VDC 26/52 VDC or 120 VAC; 1 18"L, 13"W, 11"H 35
KVAR. Son diseos para instalacin fija Bancos DC
K576 500 Amps DC 2.5 Amps 52 VDC 120 VAC; 1; 0.25 HP 28"L, 24"W, 27"H 160
tanto en interiores como exteriores y vienen Porttiles
equipados con paneles de control para K571 1000 Amps DC 5 Amps 28 or 52 VDC 120 VAC; 1; 0.5 HP 28"L, 23"W, 63"H 295
operacin remota (de 19" para montaje Banco Resistivo K580 750 - 1250 KW 5 or 50 KW 240/480 VAC; 3 208-230/460 VAC; 3; 5 HP 208"L, 93"W, 84"H 4,000*
Banco de carga resis-
sobre rack o en gabinetes tipo NEMA). tivo/reactivo de alta para Exteriores
1500 - 2000 KW 188"L, 93"W, 118"H 6,000*
capacidad con base Montado en LTV 5 or 50 KW 480 VAC; 3 480 VAC; 3
Los bancos inductivos/reactivos de Avtron 2500 - 3000 KW 208"L, 93"W, 118"H 7,500*
metlica (modelo LPS) Remolque
contienen reactores de carga monofsi
cos y trifsicos con ncleos de hierro no Disponible de 1875 a
Banco Resistivo/
2500 KVAR. 2000 KW; 1500 KVAR 50 KW; 37.5 KVAR
saturados. Reactivo para
LPS or or 480 VAC; 3 480 VAC; 3 255"L, 76"W, 109"H 13,000
Exteriores Montado
Bancos de Carga en Base Metlica
1500 KW; 1125 KVAR 5 KW; 3.75 KVAR
KW montado en triler con carretes opcionales triler construido todo en acero inoxidable 2500 KW 5,000
50 KW 480 VAC; 3 (3) 10 HP; 460 VAC 120"L, 59"W, 156"H
El Controlador Remoto para cable. (modelo K580). 3000 KW 6,000
Porttil de Avtron viene 750 - 1000 KW (1) 10 HP; 460 VAC 165"L, 60"W, 148"H 10,000
incluido con la mayora K875A-MV
1500 - 2000 KW
5 or 50 KW 5 kV AC, 5 - 15 kV AC; 3
(2) 10 HP; 460 VAC 230"L, 60"W, 148"H 14,000
de los bancos de carga 3000 - 6000 KW 250, 500, or 5 kV AC; 3, 187"L, 102"W, 192"H 13,000 -
de alta capacidad K922A (4) to (8) 10 HP; 460 VAC
per module 1000 KW 5 - 15 kV AC; 3 (typical 4500 KW unit) 17,000
(LCV y LPS). Tambin 480 VAC; 3,
se puede adquirir de Banco para K841 150 to 375 KVAR 3.75 KVAR 120 VAC; 1 54"L, 52"W, 92"H 4,500
240/480 VAC; 3
forma opcional para los bancos de carga Paquete estndar 1250 Montaje Fijo Tipo
480 VAC; 3, 116"L, 66"W, 80"H 6,000 -
KW montado en triler Reactivo K841B 375 to 1875 KVAR 3.75 or 37.5 KVAR 120 VAC; 1
LTV y K580 montados en triler. 240/480 VAC; 3 144"L, 66"W, 80"H 10,000
con carretes opcionales
Este resistente, compacto y ligero equipo para cable (modelo Banco Resistivo/ 3000 KW/2250 KVAR
29,000 -
ha sido diseado para operarlo de forma K580). Reactivo para LCV 4000 KW/3000 KVAR 25 KW/18.75 KVAR 480 VAC; 3 460 VAC; 3; 10 HP x 3 or 6 240"L, 96"W, 108"H
37,000
fcil. Todos los controles del banco de carga Montar en Container 5000 KW/3750 KVAR
son activados presionando el teclado tipo
membrana. Las funciones del banco de Alimentacin del Control: Por lo general el tipo de potencia requerida Medicin Digital: El Sistema Avanzado de Monitoreo Digital Avtron
carga se muestran en la pantalla LCD con para operar un circuito de control es de 120 VAC, una fase, 60 Hz, sin (ADMS en ingls) es suministrado junto con la mayora de los Bancos
iluminacin posterior. De igual forma, el con embargo, si no tiene disponible dicho voltaje, podemos suministrarle un de Carga Porttiles de Avtron y de forma opcional para otros modelos. El
trolador posee un botn de parada de emer Gran paquete montado transformador monofsico de potencia para el control. Medidor Digital Multifuncional de Potencia, despliega medidas de voltaje,
en plataforma con Potencia para el Ventilador: Regularmente el suministro de potencia para corriente, frecuencia y potencia e incluye un software comunicador EXT
gencia cableado. La comunicacin entre el
banco de carga resis- los ventiladores se obtiene de una fuente externa. Avtron posee modelos de recoleccin de datos.
controlador y el PLC del banco de carga se
tivo/reactivo (modelo de Bancos de Carga que se surten con una derivacin para obtener de la Nota: Otros modelos con diferente KW/KVAR estn disponibles bajo
hace por medio de un cable de 200 pies y
LCV) y transformador planta en prueba esta potencia necesaria. pedido. Las especificaciones estn sujetas a cambios sin previo aviso.
un conector tipo MS. para bajar el voltaje.
* Incluye remolque.
6 3
UALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
ELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY SERVIC
VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY VALUE QUALIT
RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE QUALITY RELIABILITY
ERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVIC
Avtron Loadbank, Inc. Bancos de Carga Avtron Bancos de Carga para Media Tensin
Desde 1953, Avtron ha sido lder en el Los bancos de carga son dispositivos di Avtron es lder en la fabricacin de verdade
diseo y manufactura de productos de alta seados para proporcionar cargas elctricas ros bancos de carga para voltajes de media
calidad y confiabilidad, dirigidos a las ms que sirven para probar fuentes de potencia tensin.
exigentes aplicaciones industriales. Los pro tales como generadores y Fuentes de Poder Estas unidades operan con la salida regular
ductos Avtron incluyen: Ininterrumpible (UPS en ingls). Los ban de voltaje de los generadores por lo que no
Bancos de Carga Resistivos y cos de carga son usados igualmente para requieren de transformadores para bajarlo.
Reactivos reducir problemas de carbonizacin en
motores diesel de sistemas de generacin Un mdulo tpico brinda una capacidad para
Resistencias Industriales 4 a 6 megawatts y cuando el requerimiento
Equipos de Prueba para sistemas de emergencia.
es mayor a decenas o centenas de mega
elctricos de Aeronaves La mayora de los bancos de carga resisti watts, entonces se utilizan varios mdulos.
Equipos de Instrumentacin Digital vos de Avtron poseen elementos resistores Por lo general los voltajes van de un rango
Sistemas de Control Digital Helidyne. Estos componentes diseados de 5 a 15 KV.
Avtron est 100% comprometido en man y fabricados por Avtron, estn elaborados El modelo K922A (izquierda) es uno de los Econmico Sistema de bancos de carga de
Los elementos Helidyne de Avtron se Sin embargo, si el cliente lo requiere, se les
tener los altos estdares que los clientes con una aleacin de cromo resistente a la encuentran totalmente reforzados y operan a varios tipos de mdulos de media tensin media tensin, montado en base deslizante
corrosin y se encuentran asegurados por puede suministrar el voltaje que necesite. usados por fbricas con grandes turbinas para disponible de 750 a 2000 KW (modelo K875A-
esperan en cuanto a: Diseo, Manufactura y bajas temperaturas para mayor durabilidad.
medio de varillas de acero inoxidable con Hay disponibles tambin diseos de bancos pruebas de produccin. MV-mostrado arriba).
Soporte Tcnico de todos sus productos. de carga tipo convencional con transforma
segmentos aisladores de cermica. Todas las partes son cuidadosamente seleccionadas
Dcadas de amplia experiencia proporcio para operar a bajas temperaturas, a fin de proporcionar un mejor rendimiento y confiabilidad, dores para bajar el voltaje (modelo K875A-
nan a Avtron la capacidad de satisfacer eliminando con esto el uso de perodos de enfriamiento luego de operar los bancos de MV) montados en bases estructurales .
cualquier requerimiento en lo referente a carga.
diseos de bancos de carga. Avtron ofrece
as mismo, una lnea completa de bancos Aplicaciones
de carga prediseados, los cuales tienen
Los bancos de carga tienen un amplio rango de aplicaciones tales como:
Bancos de Carga Montados en Ductos y Radiadores
la ventaja de resultar ms econmicos y de
estar disponibles con mayor rapidez. Pruebas en fbrica de plantas generadoras Los bancos de carga Avtron Mod. K711 removibles para ductos a fin de facilitar
Reducir problemas de carbonizacin y K711A estn diseados para montarse la instalacin y montaje. Estos bancos de
Sistema de Calidad con Ejercicio peridico de plantas de emergencia en radiadores o ductos de motores diesel carga estn dimensionados por lo general
de plantas generadoras. Estos bancos de al 50-60% de la capacidad en KW del gene
Certificacin ISO 9001 Prueba de sistemas UPS
carga son de montaje fijo y se colocan rador o, para complementar la carga actual
Prueba de sistemas de bateras
El Sistema de Calidad de Avtron est cer Prueba de tierras en sistemas de potencia frente al generador del motor y estn dimen del generador y minimizar as los efectos de
tificado de acuerdo a la norma ISO 9001. Optimizacin de carga en aplicaciones de potencia primaria sionados para acoplarse a lo largo y ancho carbonizacin de los motores diesel.
Esto significa que los productos Avtron Prueba de turbinas en fbricas. del radiador o del ducto de salida. El banco Las capacidades nominales son de 8 a
cumplen consistentemente con las ms de carga utiliza el aire de enfriamiento del 1000 KW en voltajes de 208, 240, 480
Avtron fabrica tanto los bancos de cargas como el equipo auxiliar necesario para realizar
altas normas de la calidad. motor en lugar del ventilador interno de un VAC, 3 fases, 60 Hz.w
estas y otras aplicaciones. Para seleccionar el mejor sistema de banco de carga que su
banco convencional.
empresa requiere, contacte a un representante de ventas Avtron, quien le brindar un ade
Requerimientos NFPA cuado asesoramiento tcnico. Se suministra una brida de montaje supe
rior e inferior, o bien bridas de adaptacin
La Asociacin Nacional de Proteccin con
tra Incendios (NFPA en ingls), elabora nor Mejorar La Confiabilidad de Plantas Generadoras Banco de carga para montaje en radiador o
ducto de 10 1000 KW (modelo K711).
mas de prueba para Sistemas de Potencia Tanto las industrias comerciales como las manufactureras reconocen que un programa de
de reserva y emergencia, las cuales incluy mantenimiento preventivo es vital para que un generador de emergencia o de reserva opere
en la NFPA 70, la NFPA 99 y la NFPA 110. de forma confiable. Los Bancos de Carga vienen a ser una parte esencial de tales program
Estas normas sirven como guas para la
aceptacin de instalaciones de sistemas de
as., proporcionando medios prcticos para probar los sistemas de potencia sin necesidad de Resistores Avtron para Aterramiento de Neutros
interrumpir las cargas crticas.
potencia, para realizar pruebas peridicas y Los resistores Avtron para aterramiento de con falla a tierra (que son por lo general de
de mantenimiento; adems establece espe Las principales causas de que un motor diesel falle, es la carbonizacin (acumulacin de
combustible sin quemar en los pistones del motor) y esto ocurre cuando el generador opera neutros, estn diseados para brindar una 10.000 a 20.000 amps). Colocando un resis
cficamente las pruebas requeridas para mayor seguridad en los sistemas industri tor para aterramiento de neutros Avtron, se
sistemas de potencia utilizados en centros con una baja carga. Los motores diesel con muy baja carga o que operan en vaco por pero
dos prolongados, nunca alcanzan la temperatura recomendada de operacin. Con el tiempo, ales de distribucin, por medio de la limit limita la corriente de falla a un nivel seguro
de salud. Todas estas normas requieren que acin a niveles razonables de las corrientes (de entre 25 a 400 amps), mientras se
las pruebas de los sistemas de potencia de el combustible no quemado, cubre la cmara de combustin, reduciendo la capacidad nomi
nal, la eficiencia y la vida til del motor. Un programa de mantenimiento preventivo que incluya de falla a tierra. En un sistema tpico de 4 permite el suficiente flujo de corriente para
respaldo se realicen con cargas parciales o conductores con conexin slida a tierra, operar los relevadores de eliminacin de
totales utilizando equipos de carga. Los ban pruebas con carga de la planta generadora reducir los efectos dainos de la carbonizacin
e incrementar la vida til del motor. el neutro est directamente conectado a falla. Limitando la corriente de falla tambin
cos de carga Avtron proporcionan la capaci la tierra fsica. Esto puede causar serios se reduce el problema de picos transitorios
dad de carga necesaria para realizar todas
estas pruebas en sistemas de potencia de
Ventajas de La Construccin con Acero Aluminizado daos a los transformadores, motores, gen de voltaje ( de hasta 6 veces el voltaje nor
eradores, al cableado y a los equipos aso mal) que pueden ocurrir durante los arcos
emergencia y de respaldo, cumpliendo as Los Bancos de Carga convierten la energa elctrica en calor. Gran parte de este calor es ciados, debido a las corrientes muy altas de falla a tierra.
con los requerimientos de la NFPA. disipado gracias a un ventilador de enfriamiento. Sin embargo, el gabinete tiende a absorber
una porcin de este calor, por lo que debe ser construido con un material que soporte estos Resistor de Aterramiento de Neutros para
ambientes trmicos. Es por ello que los gabinetes de los Bancos de Carga Avtron, son cons 4160/2400 volts, 400 amps, 10 segundos.
truidos con acero aluminizado, material que ofrece una mejor y mayor proteccin contra el
calor y la corrosin que los aceros galvanizados comunes.
2 7
ALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE
QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
ELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY
SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY
ALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILITY SERVICE
BANCOS DE CARGA
RELIABILITY SERVICE VALUE QUALITY RELIABILITY
Fp = KW Generador 4 cond. Estrella Banco de carga 3 cond en delta
SERVICE VALUE QUALITY RELIABILITY SERVICE VALUE
KVA IL
A QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILIT
KVAR = KVA - KW
2 2
Los KW nominales del grupo motor-gene Neutral QUALITY RELIABILITY SERVICE VALUE QUALITY RELIABILI
VL-L