Vous êtes sur la page 1sur 4

Combined effect, ULS-Flexure, torsion and shear

fck = 40 Mpa cc = 1
fyk = 550 Mpa fcd = cc.fck/c
c = 1.3775 = 29.038 Mpa
s = 1.14 fyd = fyk/s
= 482.46 Mpa
Reduction factors
t = 0.7-fck/200, but not less than 0.45 Effective factor for inplane shear, closed torsiona
= 0.45
m = 0.98-fck/500, but not less than 0.6 Effective factor for bending
0.6

Torsion
c = 45 mm TEd = 125 kN.m
l = 16 mm MEd = 175 kN.m
t = 20 mm VEd = 0 kN
bgirder = 0.6 m
hgirder = 0.8 m

Agirder = bgirder.hgirder = 0.48 m2


ugirder = 2.bgirder+2.hgirder = 2.8 m
teff = 0.146 m
Ak = Agirder-[tef.bgirder+(hgirder-tef).tef] = 0.30 m2
uk = [(bgirder-tef)+(hgirder-tef)].2 = 2.216 m
cw = 1
cot() = 2 = 0.46365 rad
To limit maximum tosional moment with the acting torsional moment, Equate T Rd,max=TEd

TRd,max = 2.t.cw.fcd.Ak.tef.sincos

TRd,max = 453 kN.m > TEd


Required Longitudinal reinforcement
TEd.uk.cot
Asl = = 1933.697 mm2
2.Ak.fyd
Required Transverse reinforcement
TEd
Asw = = 218.1517 mm2/m
2.Ak.fyd.cot
Additional tensile force at top due to torsion
FT.top = 0.5.Asl.fyd = 466 kN
FT.bot = 0.5.Asl.fyd = 466 kN

Flexure
Number of tendon to remove,
FT.top
ntendon = = 0.117
2850 mm2.1395 Mpa
Thickness of concrete to remove, scaled according to the eff. for flexure,
FT.bot
tconcrete = = 45 mm
bgirder.fcd.m

Section Capacity in flexure & Lever Arm found in Pcross


MRd = 200 kNm
ZPcross = 647 mm

Additional tensile force due to shear


TV_Ed = 0.5.VEd.(cot) = 0 kN
MV_Ed = TV_Ed.ZPcross = 0 kNm
MEd_Total = MEd+MV_Ed = 175 kNm
Utilization factor for the combined effect = 0.875
Eq. 3.15 DS/EN 1992-1-1:2004 E

ane shear, closed torsional flow.


Eq 5.103 NA DS/EN 1992-1-1 DK
NA:2013

Eq 5.102 NA DS/EN 1992-1-1 DK


NA:2013

Eq 6.30 DS/EN 1992-1-1:2004 E

Check=Ok

Spacing of Trans.
Bar
= 921.7
Check=Ok

Vous aimerez peut-être aussi