Item Description
Item Description
G
Composite wall 430 mm thick comprising of 2 skins 200, 200 mm
thick and 30 mm thick cavity with 50 mm thick rigid insulation
Item Description
A
Composite wall 460 mm thick comprising of 2 skins 200, 200 mm
thick and 60 mm thick cavity with 50 mm thick rigid insulation
B
Composite wall 500 mm thick comprising of 2 skins 200, 150 mm
thick and 150 mm thick cavity with 50 mm thick rigid insulation
Item Description
Item Description
BILL No. 4
DIVISION 4 - MASONRY
Carried to Summary
Item Description
Item Description
E
900mm high floor mounted including intermediate railings
Item Description
EXTERNAL STEPS
A
900mm high floor mounted including intermediate railings
TRENCH COVER
C Mild steel cover grating, 600mm wide (Item A page No. 3/5/5(Add-
3))
D Mild steel cover grating, 300mm wide (Item B page No. 3/5/5(Add-
3))
MANHOLE COVER
Item Description
Heavy duty steel access manhole cover for lifting station complete,
including frames ,angles,anchors and all fixing accessories all as
specified and as shown in the drawings
Item Description
METAL WORKS
ALUMINUM PANEL
SUNSCREEN
Item Description
Item Description
SUNSHADE
STEEL COLUMNS
Item Description
Item Description
A Type TA-5 stainless steel floor transition (Ref. DWG No. I503.3)
Item Description
Item Description
BILL No. 4
DIVISION 5 - METALS
Carried to Summary
Item Description
COUNTER TOP
Approved vanity counter top with fascia and splash back, provision
for vanity basin etc., including all necessary support, , fixing and all
fixing accessories, all as specified and as shown in the drawings.
B.1 450 mm wide x 700 mm long, Holed for one lavatory (Lavatory #
3)
B.2 510 mm wide x 700 mm long, Holed for one lavatory (Lavatory #
3)
B.3 535 mm wide x 700 mm long, Holed for one lavatory (Lavatory #
3)
B.4 600 mm wide x 800 mm long, Holed for one lavatory (Lavatory #
3)
B.5 570 mm wide x 980 mm long, Holed for one lavatory semi
-round -shape (Lavatory # 3)
B.6 600 mm wide x 1105 mm long, Holed for one lavatory (Lavatory
# 3)
B.7 600 mm wide x 1200 mm long, Holed for one lavatory (Lavatory
# 3)
B.8 600 mm wide x 1350 mm long, Holed for one lavatory (Lavatory
# 3)
B.9 600 mm wide x 1495 mm long, Holed for one lavatory (Lavatory
# 3)
B.10 600 mm wide x 1535 mm long, Holed for one lavatory (Lavatory
# 3)
Item Description
B.11 600 mm wide x 1630 mm long, Holed for one lavatory (Lavatory #
3)
B.12 600 mm wide x 1680 mm long, Holed for one lavatory (Lavatory #
3)
B.13 600 mm wide x 2440 mm long, Holed for one lavatory (Lavatory #
3)
B.14 600 mm wide x 2485 mm long, Holed for one lavatory (Lavatory #
3)
B.15 600 mm wide x 2845 mm long, Holed for one lavatory (Lavatory #
3)
B.16 600 mm wide x 3080 mm long, Holed for one lavatory (Lavatory #
3)
B.17 600 mm wide x 3160 mm long, Holed for one lavatory (Lavatory #
3)
B.18 600 mm wide x 3725 mm long, Holed for one lavatory L-Shape
type (Lavatory # 3)
B.19 600 mm wide x 3950 mm long, Holed for one lavatory L- Shape
type (Lavatory # 3)
B.20 450 mm wide x 1300 mm long, Holed for one lavatory (Lavatory #
3)
B.21 455 mm wide x 510 mm long, Holed for one lavatory (Lavatory #
4)
B.22 570 mm wide x 980 mm long, Holed for one lavatory (Lavatory #
4)
Item Description
Item Description
Item Description
COUNTERS (Cont)
Item Description
COUNTERS (Cont)
Item Description
COUNTERS (Cont)
Item Description
COUNTERS (Cont)
Item Description
COUNTERS (Cont)
Item Description
COUNTERS (Cont)
A
840 mm wide 6350 mm long (Item P page No. 3/6/2(Add-3))
B
610/330 mm wide 3110 mm long (Item C page No. 3/6/1(Add-3))
C
600/330 mm wide 3110 mm long (Item C page No. 3/6/1(Add-3))
D
900 mm wide 7510 mm long (Item H page No. 3/6/2(Add-3))
E
900 mm wide 6550 mm long (Item G page No. 3/6/2(Add-3))
F
840 mm wide 7310 mm long (Item H page No. 3/6/2(Add-3))
Item Description
COUNTERS (Cont)
A
330 mm wide 1650 mm long
B
Ditto but 2450 mm long
Item Description
COUNTERS (Cont)
A
610 mm wide 4000 mm long (Item E page No. 3/6/1(Add-3))
Item Description
ACRYLIC PANELS
Supply and install acrylic panels for walls and ceiling accent
including all necessary support, , fixing and all fixing
accessories, all as specified and as shown in the drawings.
MILLWORK
Item Description
BILL No. 4
DIVISION 6 - WOOD AND PLASTIC
Carried to Summary
Item Description
VAPOR BARRIER
WATER PROOFING
C
To the horizontal surfaces, under and top of isolated
footings,strip footings,raft foundations and retaining walls.
Item Description
A
Type RF1, roofing system (Item A page No. 3/7/2(Add-3))
C
Type RF3, concrete roof pavers or gravel field on fluid
applied roof system (Item C page No. 3/7/2(Add-3))
Item Description
Water Stop
Item Description
BILL No. 4
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
Carried to Summary
Item Description
STEEL DOORS
A
Door Type 03-19.Db.A1F, double leaf, swing type with
hardware set Db-F0.A.SW.15, (45 Minutes fire rated).
F
Door Type 06-01.DbA2F (M21-003), double leaf, swing type with
hardware set Sn.-F0.A.SW.08, (45 Minutes fire rated).
Item Description
Item Description
A
Door Type 06-03.DbA1 (M21-012), double leaf, swing type with
hardware set Db.-F0.A.SW.01, (90 Minutes fire rated).
C
Door Type 06-07.SnA1F (M11-024), single leaf, swing type with
hardware set Sn.-F0.A.SW.08, (90 Minutes fire rated).
G
Door Type 10-SnE1FS (M11-034), single leaf, swing type with
hardware set Sn.-F1.E.SW.04, (90 Minutes fire rated).
L Door Type (M11-001), single leaf, swing type door (45 Minutes
fire rated).
Item Description
M
Door Type (M11-005), single leaf, swing type door (90 Minutes fire
rated) (same as 06-01.SnA2F Item E page No. 3/8/1(Add-3))
Item Description
A
Door Type (M11-009), single leaf, swing type door (45 Minutes fire
rated) (same as 06-02.SnA1F Item C page No. 3/8/2(Add-3))
B Door Type (M11-017), single leaf, full swing type door (90
Minutes fire rated).
C Door Type (M11-021), single leaf, swing type door (90 Minutes
fire rated).
D Door Type (M11-022), single leaf, full swing type door (90
Minutes fire rated).
E Door Type (M11-023), single leaf, swing type door (90 Minutes
fire rated).
F Door Type (M11-026), single leaf, swing type door (45 Minutes
fire rated).
G
Door Type (M11-031), single leaf, swing type door (90 Minutes fire
rated) (same as 10-SnE1F Item A page No. 5/8/2(Add-3))
H Door Type (M11-039), single leaf, swing type door (90 Minutes
fire rated).
J Door Type (M11-040), single leaf, swing type door (90 Minutes
fire rated).
K Door Type (M11-041), single leaf, swing type door (90 Minutes
fire rated).
L Door Type (M11-042), single leaf, swing type door (45 Minutes
fire rated).
Item Description
Item Description
D Door Type (M21-005), double leaf, swing type door (90 Minutes
fire rated) (same as 06-01.DbA3F Item C page No. 3/8/11(Add-
3))
E Door Type (M21-006), double leaf, swing type door (90 Minutes
fire rated).
F
Door Type (M21-008), double leaf, swing type door (90 Minutes
fire rated) (same as 06-02.DbA2F Item K page No. 3/8/1(Add-3))
G Door Type (M21-026), double leaf, swing type door (90 Minutes
fire rated).
H Door Type (M21-027), double leaf, swing type door (90 Minutes
fire rated).
J Door Type (M21-028), double leaf, swing type door (45 Minutes
fire rated).
K Door Type (M21-029), double leaf, swing type door (45 Minutes
fire rated).
L Door Type (M21-030), double leaf, swing type door (45 Minutes
fire rated).
M Door Type (M21-031), double leaf, swing type door (45 Minutes
fire rated).
Item Description
Item Description
A Door Type (M21-033), double leaf, swing type door (45 Minutes
fire rated).
B Door Type (M21-034), double leaf, swing type door (45 Minutes
fire rated).
C Door Type (M21-036), double leaf, swing type door (45 Minutes
fire rated).
D Door Type (M21-037), double leaf, swing type door (45 Minutes
fire rated).
Item Description
Item Description
ALUMINUM DOORS
Item Description
Item Description
C
Door Type (A/G20-010), double leaf, sliding and swinging type
door (same as 12-03.DbA2 Item J page No. 3/8/6(Add-3))
D Door Type (A/G40-001), four leafs, sliding type door with two
fixed leafs
E Door Type (A/G40-008), four leafs, sliding type door with two
fixed leafs
F Door Type (A/G40-009), four leafs, sliding type door with two
fixed leafs
Item Description
Item Description
GLASS DOORS
Item Description
Item Description
WOOD DOORS
Item Description
Item Description
G
Door Type 03-03.SnA1F (W11-012), single leaf, swing type with
hardware set Sn-F0.A.SW.08, (45 Minutes fire rated).
K
Door Type 03-01.SnA1FP (W11-007), single leaf, swing type with
hardware set Sn-F2.A.SW.01, (45 Minutes fire rated).
L
Door Type 03-04.SnA1FP (W11-014), single leaf, swing type with
hardware set Sn-F2.A.SW.01, (45 Minutes fire rated).
Item Description
Item Description
F
Door Type 03-09.SnA1FS (W11-024), single leaf, swing type with
hardware set Sn-F1.A.SW.02, (45 Minutes fire rated).
Item Description
Item Description
E.1 Door Type 07-SnA1R (W12-006), single leaf, swing type with
hardware set Sn-00.A.SW.47
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
A
Door Type (W10-005), single leaf, full swing type door.
C
Door Type (W10-013), single leaf, full swing type door.
D
Door Type (W10-016), single leaf, full swing type door.
H Door Type (W10-051), single leaf, swing type door (same as 04-
SnA2 Item K page No. 3/8/14(Add-3))
K Door Type (W10-054), single leaf, swing type door (same as 04-
SnA4 Item M page No. 3/8/14(Add-3))
N Door Type (W10-063), single leaf, swing type door (same as 06-
09.SnA1 Item A page No. 3/8/16(Add-3))
P Door Type (W10-083), single leaf, swing type door (same as 08-
06.SnA2 Item D page No. 3/8/18(Add-3))
Item Description
Item Description
C Door Type (W10-099), single leaf, swing type door (same as 11-
SnE1 Item C page No. 3/8/23(Add-3))
F Door Type (W10-107), single leaf, swing type door (same as 12-
01.SnA3 Item C page No. 3/8/24(Add-3))
G Door Type (W10-117), single leaf, swing type door (same as 15-
SnA1P Item D page No. 3/8/26(Add-3))
H Door Type (W10-118), single leaf, swing type door (same as 15-
SnA1S Item E page No. 3/8/26(Add-3))
K Door Type (W11-002), single leaf, swing type door (45 Minutes
fire rated).
L Door Type (W11-010), single leaf, swing type door (45 Minutes
fire rated).
M
Door Type (W11-011), single leaf, swing type door (45 Minutes
fire rated) (same as 03-02.SnA1Fs Item G page No. 3/8/11(Add-3))
N Door Type (W11-013), single leaf, full swing type door (45
Minutes fire rated).
Item Description
O
Door Type (W11-030), single leaf, swing type door (45 Minutes
fire rated) (same as 03-12.SnA1FP Item K page No. 3/8/12(Add-3))
P Door Type (W11-032), single leaf, swing type door (90 Minutes
fire rated).
Item Description
A Door Type (W11-038), single leaf, swing type door (45 Minutes
fire rated).
B Door Type (W11-039), single leaf, swing type door (90 Minutes
fire rated).
C Door Type (W11-040), single leaf, swing type door (45 Minutes
fire rated).
D Door Type (W11-045), single leaf, swing type door (90 Minutes
fire rated & smoke sealed) (same as 04-SnA1FS Item D page No.
3/8/14(Add-3))
E Door Type (W11-046), single leaf, swing type door (90 Minutes
fire rated).
F Door Type (W12-003), single leaf, swing type door (same as 05-
SnA1R Item C page No. 3/8/15(Add-3))
G
Door Type (W12-009), single leaf, surface sliding type door.
H Door Type (W20-035), double leaf, swing type door (same as 11-
DbA4P Item M page No. 6/8/6(Add-3))
L
Door Type (W20-044), double leaf, double egree type door (same
as 11-DbE1P Item B page No. 3/8/21(Add-3))
M Door Type (W20-045), double leaf, swing type door (same as 11-
DbE1S Item C page No. 3/8/21(Add-3))
Item Description
N Door Type (W20-048), double leaf, swing type door (same as 11-
DbE3 Item J page No. 3/8/21(Add-3))
Item Description
D
Door Type (W20-062), double leaf, full swing type door
F Door Type (W21-020), double leaf, swing type door (45 Minutes
fire rated).
G Door Type (W21-035), double leaf, swing type door (90 Minutes
fire rated).
H Door Type (W21-036), double leaf, swing type door (90 Minutes
fire rated).
J Door Type (W21-049), double leaf, double egree type door (90
Minutes fire rated).
K Door Type (W21-050), double leaf, swing type door (45 Minutes
fire rated & smoke sealed) (same as 11-DbE5F Item E page No.
3/8/22(Add-3))
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
SKYLIGHT
Item Description
Item Description
WINDOWS
Item Description
Item Description
Item Description
BILL No. 4
DIVISION 8 - DOORS AND WINDOWS
Carried to Summary
Item Description
PORCELAIN TILE
Porcelain tiles to floor bedded and jointed in cement and sand mortar
including cutting, trims, accessories grouting and pointing and cleaning
on completion; all as specified and as shown on the drawings.
C.3 (Por.-3) 45 x 45 cm Porcelain floor tiles (Item E.1 in page No. 3/9/2(Add-
3))
Item Description
Item Description
D.1
(Por-20) 30 x 30 cm Porcelain wall tiles (equal to Por-21, Por-27)
SKIRTING/BASE
Item Description
Item Description
STONE FINISHES
MARBLE
Marble floor tile bedded and jointed in cement and sand mortar
including approved fill materials, grouting and pointing on completion;
all as specified and as shown on the drawings
A Botticino classico
A.1
ST-5 Crema marfil polished marble floor tiles 30 x 60 cm
A.3
ST-7 Silver drop polished marble floor tiles 30 x 60 cm
A.5
combination of stone marble types to level L1 at lobby
A.6
combination of stone marble types to level L1 at reception
STAIRCASE FINISHES
Marble floor tile bedded and jointed in cement and sand mortar including
approved fill materials, grouting and pointing on completion; all as
specified and as shown on the drawings.
B
To staircase -no.3 landing (From basement to ground floor)
Item Description
Item Description
STONE CLADDING
Item Description
Item Description
CARPET TILE
E Carpet tile
F Resilient sheet
SKIRTING
Item Description
Item Description
WOOD PANEL
WOOD CLADDING
Wood veneer wall cladding (flat cut cherry finish), cladded &
jointed with approved fixing system including fixing anchors, pins,
cutting to size etc.; complete set including approved fill materials,
grouting and pointing on completion; all as specified and as per
drawings.
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
J GL-31 Vitra color - side 1 satin finish, side 2 vitra color glass
panel
Item Description
Item Description
WALL COVERING
D
Raised access floor at electrical ATS room including all access
hatches as specified and as shown on the drawings.
ARCHITECTURAL SCREEN
Item Description
Item Description
SUSPENDED CEILING
D.1 600 x 600 mm Acoustical tile ceiling (ACT-3) (Item B.2 page No.
3/9/10(Add-3))
WALL PANEL
Item Description
Item Description
Prepare & apply two coats undercoat, three coats of putty and three
finishing coats of water based emulsion paint; all as specified and as
shown on the drawings (internally);
A
To gypsum board wall partition and gypsum board cladding
Item Description
Item Description
Prepare and apply two coats of two component solvent free epoxy resin
D
Ditto but to concrete broom finish at access ramp in first floor
E
Ditto but to concrete broom finish at access ramp in ground floor
Item Description
Item Description
STAIRCASE FINISHES
D
Ditto but to staircase no.2 landing (From basement to ground floor)
G
Ditto but to staircase -no.4 landing (From ground to seventh floor)
Item Description
Item Description
EXTERNAL STEPS.
A
Epoxy paint on fair faced concrete for external landing of steps.
Item Description
Item Description
BILL No. 4
DIVISION 9 - FINISHES
Carried to Summary
Item Description
FIRE EXTINGUISHERS
A Fire extinguisher type FE-1 (6 kg, multi purpose dry chemical type)
Item Description
Item Description
Toilet and Bath accessories with all fixing accessories & fixing
complete as specified and as shown in the drawings and as per
schedule.
A Tissue Holder-1
B Tissue Holder-2
C Tissue Holder-3
D Soap dispenser-1
E Soap dispenser-2
F Towel Holder-1
G Towel Holder-2
H Towel Holder-3
J Grab Bar-2
K Grab Bar-3
L Grab Bar-4
M Grab Bar-5
N Shower Curtain-1
O Shower Curtain-2
P Hook-1
Q Hook-2
R Shower Seat
Project No. JE-1257
Volume III 4/10/118
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 10
SPECIALTIES
Item Description
Item Description
MIRRORS
A Mirror- 1
B Mirror- 2
C Mirror- 3
C.1 2000mm wide x 1535mm high with wood frame matching the
door finish
METAL LOCKERS
E
Ditto, but 2000 mm long beside STFT RM in ground floor level
F
Ditto, but 2420 mm long beside STFT RM in ground floor level
Item Description
Item Description
BARRIER ARM
Supply and installation barrier arm including with all finishes and
fixing accessories complete as per requirments, as shown in the
drawings and specification
TIRE KILLER
Supply and installation tire killer including with all finishes and
fixing accessories complete as per requirments ,as shown in the
drawings and specification
WALL PROTECTION
D.1
(WP-13 & 15 ) Rigid vinyl wall covering , Velvet finish
Item Description
Item Description
SYSTEM FURNITURE
F System furniture
Item Description
Item Description
INTERNAL SIGNAGE
Signage Code 1.8 - Leaf sign with No. & text / leaf sign toilet /
H prayer room.
Signage Code 1.9 - Leaf sign for exam room curtains area (recovery
J base area).
Item Description
Item Description
Signage Code 3.2 - Main directory (ground floor lobby area) sign.
D
Signage Code 4.2 - Staircase with exite to ground floor info sign.
H
Signage Code 4.3 - Elevator sign includes level info (FOH / BOH).
J
Item Description
Item Description
BILL No. 4
DIVISION 10 - SPECIALTIES
Carried to Summary
Item Description
FURNISHING WORKS
A Medical curtain
B
Supply, delivery and installation of modular lab system furniture as
per specifications, catalogue and as shown on the drawings.
Item Description
Item Description
ART WORK
Supply and install Art work including all fixing accessories &
fixing complete as specified and as shown in the drawings.
A
Large art work with diagonal dimmension more that 1500mm
Item Description
Item Description
BILL No. 4
DIVISION 12 - FURNISHINGS
Carried to Summary
Item Description
RADIATION PROTECTION
C
BMU-5, with outreach length of 3.10m, lifting height 43m,
complete with power slewing and jib head slewing including
fixed Jib arm, fixed pantograph cradle 2.40m length, capacity of
240kg. / 2 persons, anti collision bar system under the cradle with
soft faade roilers, radio frequency control system and fixed
counterweight system.
BILL No. 4
DIVISION 13 - SPECIAL CONSTRUCTION
Project No. JE-1257
Volume III 4/13/136
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 13
SPECIAL CONSTRUCTION
Item Description
Carried to Summary
Item Description
A Passenger Elevator (P01, P02, P03 & P04) Electric Traction Type,
with Machine Room.
Capacity: 1,800 Kg.
No. of Stops & Openings: 7 Nos.
Speed: 1.75 m/sec.
Car internal size: 2,100 x 1,800 mm
Car design & doors: Manufacturer standard design / options as
per Client requirement.
Item Description
Item Description
SERVICE ELEVATORS
A Service Elevator (S01, S02 & S03) Electric Traction Type, with
Machine Room.
Capacity: 2,250 Kg.
No. of Stops & Openings: 8 Nos.
Speed: 1.75 m/sec.
Car internal size: 2,600 x 1,800 mm
Car design & doors: Double door,Manufacturer standard
design/options as per Client requirement.
Item Description
Item Description
BILL No. 4
DIVISION 14 - CONVEYING SYSTEM
Carried to Summary
Item Description
Supply and install all the fire fighting systems, equipment, sleeves,
openings, blocking seam, sealants, bases (if required) and supports
for pipings, fittings, accessories and controls as required including
builders work in connection with fire fighting system as per NFPA
requirement & Civil Defence complete as required, as shown on
the drawings and as specified.
A 25mm diameter
B 32mm diameter
C 40mm diameter
D 50mm diameter
E 65mm diameter
F 80mm diameter
G 100 mm diameter
Item Description
H 110 mm diameter
J 150mm diameter
Item Description
A 50mm diameter
B 65mm diameter
C 80mm diameter
E Upright sprinkler
Item Description
H 100mm
J 150mm
Item Description
E
25mm test & flushing with drain valve with short length of pipe.
H 65mm diameter Landing Valve for Stair Case with Valve Cabinet
complete as specified.(Wet - FDV)
Item Description
Item Description
B Roof manifold
C Pressure Gauge
E Type FHR (Red Paint Finish) for Parking areas, Service areas &
Mechanical rooms etc.
Item Description
Item Description
Item Description
Item Description
Supply and install all the fire fighting systems, equipment, pipings,
fittings, accessories & controls as required for the fire fighting
system as per NFPA requirement & Civil Defence complete as
required, as shown on the drawings and sepecified.
A 150mm diameter
B 110 mm diameter
G 65mm diameter Landing Valve for Stair Case with Valve Cabinet
complete as specified.
Item Description
Item Description
Supply and install all the Pre Action fire fighting systems, including
Compressor, pipings, fittings, accessories & control panel complete
as required and as per NFPA requirement & Civil Defence complete
as required, as shown on the drawings and as specified.
A 25mm diameter
B 32mm diameter
C 40mm diameter
D 50mm diameter
E 65mm diameter
Sprinkler
Item Description
Item Description
B 40mm
C 50mm
D 65mm
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
BILL No. 3
DIVISION 22 - PLUMBING
Carried to Summary
Item Description
PLUMBING SYSTEM
SANITARY FIXTURES
A European Water Closet (Type WC-1), with flush valve, seat and
cover, ablution hose and all accessories complete as required and as
specified.
B European Water Closet (Type WC-2), with flush valve, seat and
cover, ablution hose and all accessories complete as required and as
specified.
Item Description
Item Description
PLUMBING SYSTEM
H.1 Lavatory (Type LAV-7), complete with mixers & all accessories
complete as required and as specified.(Mentioned in Expansion
Building)
Item Description
Item Description
PLUMBING SYSTEM
Supply, Test and Install Soil, Waste and Vent Pipe including pipe
markings, sleeves, openings, blocking seams, sealants, bases (if
required) with all necessary fittings, brackets, hangers, supports &
fixing accessories builders work related to Plumbing works complete
as specified and as shown in the drawings.
A 200 mm diameter
B 150 mm diameter
C 100 mm diameter
D 80 mm diameter
Soil and Waste pipes (CAST IRON Epoxy Coated) laid under tiles,
above ceilings, in shafts and in walls, etc. complete as required
E 200 mm diameter
F 150 mm diameter
G 100 mm diameter
Item Description
H 80 mm diameter
J 50 mm diameter
Item Description
PLUMBING SYSTEM
Soil and Waste pipes (Double Wall Containment pipe system for
drainage pipes . PE 100 outer pipe and PE Inner pipe) with leak
detection system, laid above ceilings, in shafts and in walls, etc.
complete as required
2.A 80 mm diameter
3.A 50 mm diameter
Vent Pipes (CAST IRON Epoxy Coated) laid under tiles, above
ceilings, in shafts and in walls, etc. complete as required
A 150 mm diameter
B 125 mm diameter
C 100 mm diameter
D 80 mm diameter
E 50 mm diameter
F 150 mm diameter
G 100 mm diameter
Item Description
G.1 50 mm diameter
Item Description
PLUMBING SYSTEM
Rain Water Pipes (CAST IRON Epoxy Coated) laid under tiles,
above ceilings, in shafts and in walls, etc. complete as required
H 200 mm diameter
J 150 mm diameter
K 100 mm diameter
L 125 mm diameter
M 80 mm diameter
N 50 mm diameter
Item Description
Item Description
PLUMBING SYSTEM
D 100 mm diameter
Item Description
Item Description
PLUMBING SYSTEM
ACCESSORIES
Item Description
Item Description
PLUMBING SYSTEM
ACCESSORIES (Cont)
Item Description
Item Description
PLUMBING SYSTEM
ACCESSORIES (Cont)
D Combination main roof and over flow drains type with low
silhouette dome and double top set ,(deck plate, RD (1A,1B)(Refer
to item no O page: 5 in Oncology Building)
E Combination main roof and over flow drains type with low
silhouette dome and double top set ,(deck plate, RD (2A,2B)(Refer
to item no O page: 5 in Oncology Building)
Item Description
Item Description
PLUMBING SYSTEM
B Submersible pumps (in sump pit 3), capacity 100 GPM, 36 ft head
approx. grinder type (1 duty & 1 standby).
Item Description
Item Description
PLUMBING SYSTEM
WATER SUPPLY
Supply, Install and Test Cold and Hot water pipework including pipe
markings, sleeves, openings, blocking seams, sealants and base (if
required) with all necessary fittings, brackets, supports, hangers &
fixings accessories, builders work related to system complete as
specified and as shown in the drawings.
A 160 mm diameter.
Cold water supply pipes (Hard Copper tube) with soldered joints
above false ceilings, walls, in shafts, etc. Including all necessary
fittings and accessories, complete as required, as shown on drawings
and as specified.
B 15 mm diameter.
C 22 mm diameter.
D 28 mm diameter.
E 35 mm diameter.
F 42 mm diameter
G 54 mm diameter.
H 67 mm diameter.
J 76 mm diameter.
K 108 mm diameter.
Project No. JE-1257
Volume III 4/22/188
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING
Item Description
L 133 mm diameter.
Item Description
PLUMBING SYSTEM
A Allow for the Connection of Cold water supply pipes (Hard Copper
tube) with soldered joints to Oncology Building and Site Loop
Including additional pipe length with all necessary fittings and
accessories, complete as required, as shown on drawings and as
specified
Hot water supply and return pipes (Hard Copper tube) with soldered
joints above false ceilings, walls, in shafts, etc. Including all
necessary fittings and accessories, complete as required, as shown on
drawings and as specified.
B 15 mm diameter.
C 22 mm diameter.
D 28 mm diameter.
E 35 mm diameter.
F 42 mm diameter
G 54 mm diameter.
H 67 mm diameter.
J 76 mm diameter.
K 108 mm diameter.
Item Description
L Allow for the Connection of Cold water supply pipes (Hard Copper
tube) with soldered joints to Oncology Building and Site Loop
Including additional pipe length with all necessary fittings and
accessories, complete as required, as shown on drawings and as
specified
Item Description
PLUMBING SYSTEM
Hot water supply and return pipes Insulation (12mm thick Euroflex)
Including all necessary fittings and accessories, complete as
required, as shown on drawings and as specified.
A 15 mm diameter.
B 22 mm diameter.
C 28 mm diameter.
D 35 mm diameter.
E 42 mm diameter
F 54 mm diameter.
Hot water supply and return pipes Insulation (32mm thick Rigid
Fiberglass with Aluminum foil) Including all necessary fittings and
accessories, complete as required, as shown on drawings and as
specified.
G 67 mm diameter.
H 76 mm diameter.
J 90 mm diameter.
K 110 mm diameter.
Item Description
Item Description
PLUMBING SYSTEM
Cold and Hot water pipes accessories Including all necessary fittings,
complete as required, as shown on drawings and as specified.
Item Description
Item Description
PLUMBING SYSTEM
Accessories (Cont...)
Item Description
Item Description
PLUMBING SYSTEM
Accessories (Cont...)
Item Description
Item Description
PLUMBING SYSTEM
Supply, Install and Test Compressed Air pipework for Laboratory and
Health care Facilities including pipe markings, sleeves, openings,
blocking seams, sealants and bases (if required) with all necessary
fittings, brackets, supports, hangers and fixing accessories complete
as required, as shown in the drawings and as specified.
A 12 mm diameter.
B 15 mm diameter.
C 22 mm diameter.
D 28 mm diameter.
E 35 mm diameter.
F 42 mm diameter
Item Description
Item Description
PLUMBING SYSTEM
A 12 mm diameter.
B 22 mm diameter.
C 28 mm diameter.
Item Description
Item Description
PLUMBING SYSTEM
Item Description
Item Description
PLUMBING SYSTEM
A 15 mm diameter.
B 22 mm diameter.
C 28 mm diameter.
D 35 mm diameter.
E 42 mm diameter
F 67 mm diameter.
Item Description
Item Description
PLUMBING SYSTEM
A 12 mm diameter.
B 15 mm diameter.
C 22 mm diameter.
D 28 mm diameter.
E 35 mm diameter.
Item Description
Item Description
PLUMBING SYSTEM
Accessories (Cont.)
Item Description
Item Description
PLUMBING SYSTEM
Zone Service Unit and Alarm Panel for medical gases including all
necessary fittings, complete as required, as shown on drawings and
as specified.
A AVSU 1
B AVSU 2
C AVSU 3
Item Description
Item Description
PLUMBING SYSTEM
Item Description
Item Description
J Elevator Pit (7) , 0.6 m x 0.6 m x 0.6 m(Refer to item no. B page: 16
in Oncology Building )
Item Description
Item Description
BILL No. 3
DIVISION 22 - PLUMBING
Item Description
Carried to Summary
Item Description
HVAC SYSTEMS
Chilled water pumps, complete with VFD and all accessories, gate
valves, strainer, pressure gauge, reinforced concrete base and
vibration isolator as detailed on drawings with all other related
fittings and accessories complete as required, as shown on the
drawigns and as specified.
A Chilled water pump (Ref. CWP-5.1 & 5.2), 0.93 L/S capacity each,
175 KPA. approx. head, 1.50 KW power, END SUCTION type,
complete with all accessories as required, as shown on the
drawings and as specified.
B Chilled water pump (Ref. CWP-13.1 & 13.2), 3.12 L/S capacity
each, 175 KPA. approx. head, 1.50 KW power, END SUCTION
type, complete with all accessories as required, as shown on the
drawings and as specified.
Item Description
Item Description
HVAC SYSTEMS
Supply, Install of Air & dirt separator with pressure regulating valve
assembly, valves, air vent, drain, complete as specified and as shown in
the drawings.Included in the chilled water pipes accessories
EXPANSION TANKS
D ET-01 of Steel Pipes and chilled water fluid type (Mentioned in CUP
Parking Building)
SIDESTREAM FILTRATION
Item Description
E SFP-1, with flow 12.5 l/s and max. pressure 100 m (Mentioned in CUP
Parking Building)
Item Description
HVAC SYSTEMS
Item Description
Chilled water pipes Black Steel Seamless (Schedule 40), complete with
all accessories as specified and as shown in the drawings.
1.A 15 mm diameter.
A 25 mm diameter.
B 40 mm diameter.
C 50 mm diameter.
D 65 mm diameter.
E 75 mm diameter.
F 100 mm diameter.
G 200 mmdiameter.
H 250 mm diameter.
Item Description
Item Description
HVAC SYSTEMS
Chilled water pipes Insulation (25 mm thick Rigid Fiber glass with
Aluminum Foil, 96 kg/cu.m) and 0.6 mm thick Aluminum Cladding
for exposed pipes and in plant rooms complete with all accessories
as specified and as shown in the drawings.
A 25 mm diameter.
B 40 mm diameter.
C 50 mm diameter.
D 65 mm diameter.
E 75 mm diameter.
E.1 80 mm diameter.
F 100 mm diameter.
G 200 mmdiameter.
H 250 mm diameter.
Item Description
Item Description
A Energy Recovery unit (Ref. ERU-1), 16,373 L/S at Supply side and
8,917 L/S at Exhaust side each, complete with all accessories as
required, as shown on the drawings and as specified.
B Energy Recovery unit (Ref. ERU-2), 13,066 L/S at Supply side and
7,995 L/S at Exhaust side each, complete with all accessories as
required, as shown on the drawings and as specified.
C Energy Recovery unit (Ref. ERU-3), 10,475 L/S at Supply side and
6,392 L/S at Exhaust side each, complete with all accessories as
required, as shown on the drawings and as specified.
D Energy Recovery unit (ERU-1,2,3), 16,520 L/S Supply air flow and
847 Kw Chilled water cooling coil capacity, complete with all
accessories as required, as shown on the drawings and as specified.
(Refer to item no A page: 4 in Oncology Building)
INERTIA FILTER
Item Description
Item Description
HVAC SYSTEMS
Supply, install and test the following modular type air handling
units (ARI rated units & UL listed motors) complete with all
wiring, fittings, return bell mouths, air filters, insulations, Gate
valves, Pressure gauges, Thermometers Butterfly valves, Modulating
valves, Balancing valve , Automatic flow control valve, controls,
thermostat, fixing accessories, reinforced concrete base, vibration
pads, condensate drain pipe, flexible connections and all necessary
accessories complete as specified and as shown in the drawings.
A Ref. AHU-1-1 , total supply air 8972 L/S, total load on coil 54.6
KW.
B Ref. AHU-2-1 , total supply air 9469 L/S, total load on coil 149.4
KW.
C Ref. AHU-3-1 , total supply air 9469 L/S, total load on coil 149.4
KW.
D Ref. AHU-4-1 , total supply air 8826 L/S, total load on coil 117.7
KW.
E Ref. AHU-5-1 , total supply air 10231 L/S, total load on coil 157.4
KW.
F Ref. AHU-1-2 , total supply air 15318 L/S, total load on coil 211.0
KW.
G Ref. AHU-2-2 , total supply air 5923 L/S, total load on coil 89.1
KW.
H Ref. AHU-3-2 , total supply air 5923 L/S, total load on coil 86.1
KW.
J Ref. AHU-4-2 , total supply air 6083 L/S, total load on coil 66.9
KW.
Project No. JE-1257
Volume III 4/23/231
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 23
HEATING VENTILLATION & AIR CONDITIONING (HVAC)
Item Description
K Ref. AHU-5-2 , total supply air 6014 L/S, total load on coil 83.7
KW.
Item Description
HVAC SYSTEMS
A Ref. AHU-GL-1 , total supply air 7403 L/S, total load on coil 119.5
KW.
B Ref. AHU-GL-2 , total supply air 5913 L/S, total load on coil 89.0
KW.
C Ref. AHU-GL-3 , total supply air 5174 L/S, total load on coil 62.9
KW.
D Ref. AHU-B-1 , total supply air 6891 L/S, total load on coil 94.9
KW.
E Ref. AHU-B-2 , total supply air 6991 L/S, total load on coil 99.2
KW.
F Ref. AHU-P-1 , total supply air 6607 L/S, total load on coil 125.5
KW.
G Ref. AHU-P-2 , total supply air 6607 L/S, total load on coil 125.5
KW.
H Ref. AHUZ0.01-I, total supply air 7100 L/S, total load on coil 111
KW.(Refer to item no D page: 5 in Medical Logestic Building)
J Ref. AHUZ1.01-I, total supply air 9450 L/S, total load on coil 150
KW.(Mentioned in Oncology Building )
K Ref. AHUZ1.01-II, total supply air 7100 L/S, total load on coil 110
KW.(Mentioned in Oncology Building )
L Ref. AHUZ1.01-III, total supply air 9450 L/S, total load on coil 150
KW.(Mentioned in Oncology Building )
M Ref. AHUZ1.02-I, total supply air 9450 L/S, total load on coil 150
KW.(Mentioned in Oncology Building )
Item Description
N Ref. AHUZ1.02-II, total supply air 9450 L/S, total load on coil 150
KW.(Mentioned in Oncology Building )
Item Description
HVAC SYSTEMS
A Ref. AHUZ1.03-I, total supply air 9450 L/S, total load on coil 100
KW.(Mentioned in Oncology Building )
B Ref. AHUZ1.03-II, total supply air 9450 L/S, total load on coil 118
KW.(Mentioned in Oncology Building )
C Ref. AHUZ1.04-I, total supply air 9450 L/S, total load on coil 124
KW.(Mentioned in Oncology Building )
D Ref. AHUZ1.05-I, total supply air 9450 L/S, total load on coil 114
KW.(Mentioned in Oncology Building )
E Ref. AHUZ3.01-I, total supply air 9450 L/S, total load on coil 150
KW.(Mentioned in Oncology Building )
F Ref. AHUZ3.01-II, total supply air 9450 L/S, total load on coil 150
KW.(Mentioned in Oncology Building )
G Ref. AHUZ4.01-I, total supply air 11800 L/S, total load on coil 184
KW.(Refer to item no E page: 5 in Oncology Building)
H Ref. AHUZ4.01-II, total supply air 11800 L/S, total load on coil
184 KW.(Refer to item no E page: 5 in Oncology Building)
J Ref. AHUZ5.01-I, total supply air 11800 L/S, total load on coil 184
KW.(Refer to item no E page: 5 in Oncology Building)
K Ref. AHUZ5.01-II, total supply air 11800 L/S, total load on coil
184 KW.(Refer to item no E page: 5 in Oncology Building)
L Ref. AHUZ6.01-I, total supply air 11800 L/S, total load on coil 184
KW.(Refer to item no E page: 5 in Oncology Building)
Item Description
M Ref. AHUZ6.01-II, total supply air 11800 L/S, total load on coil
184 KW.(Refer to item no E page: 5 in Oncology Building)
SOUND ATTENUATORS
Item Description
HVAC SYSTEM
Supply, install and test the following units (ARI rated units and UL
listed motors) complete with all wiring, insulation, valves, flat filter,
flexible connection, plenum box, motorized valves, controls, circuit
breaker, space thermostat, fixing accessories, vibration pads,
condensate drain pipe etc., with all necessary insulation, accessories
complete as specified and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
J Type CRAC-1, total supply air 668 L/S, total load on coil 10.7 KW
Item Description
Item Description
HVAC SYSTEM
Item Description
Item Description
HVAC SYSTEM
Supply, install and test the following VAV units (ARI rated units and
UL listed motors) complete with accessories ( but not limited to) , all
wiring, insulation, valves, flow sensor, factory wired control voltage
transformer, factory mounted electric heating coil, automatic reset
thermal cut-out, pressure diffrential switch, electric switches for staging
etc., with all necessary insulation, accessories complete as specified
and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
Item Description
Item Description
HVAC SYSTEM
Supply, install and test the following VAV units (ARI rated units and
UL listed motors) complete with accessories ( but not limited to) all
wiring, insulation, valves, flow sensor, factory wired control voltage
transformer, factory mounted electric heating coil, automatic reset
thermal cut-out, pressure diffrential switch, electric switches for staging
etc., with all necessary insulation, accessories complete as specified
and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
Supply, install and test the following VAV units (ARI rated units and
UL listed motors) complete with accessories ( but not limited to), all
wiring, insulation, valves, flow sensor, factory wired control voltage
transformer, factory mounted electric heating coil, automatic reset
thermal cut-out, pressure diffrential switch, electric switches for staging
etc., with all necessary insulation, accessories complete as specified
and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
Supply, install and test the following SUPPLY AV units (ARI rated
units and UL listed motors) complete with accessories ( but not
limited to) Controller, all wiring, insulation, valves, flow sensor, factory
wired control voltage transformer, factory mounted electric heating coil,
automatic reset thermal cut-out, pressure differential switch, electric
switches for staging etc., with all necessary insulation, accessories
complete as specified and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
Supply, install and test the following RETURN AVEE units (ARI
rated units and UL listed motors) complete with accessories ( but not
limited to) Controller, all wiring, insulation, valves, flow sensor, factory
wired control voltage transformer, factory mounted electric heating coil,
automatic reset thermal cut-out, pressure differential switch, electric
switches for staging etc., with all necessary insulation, accessories
complete as specified and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
Supply, install and test the following EXHAUST AVE units (ARI
rated units and UL listed motors) complete with accessories ( but not
limited to) Controller, all wiring, insulation, valves, flow sensor,
factory wired control voltage transformer, factory mounted electric
heating coil, automatic reset thermal cut-out, pressure differential
switch, electric switches for staging etc., with all necessary insulation,
accessories complete as specified and as shown in the drawings.
Item Description
Item Description
HVAC SYSTEM
RETURN FAN'S
Supply, Install and test the following Return Fans type Smoke Rated
Fan Complete with VFD (UL listed / FM approved), including flanges,
support framing, mounting bolts, isolating switches overload
protection, back draft damper and all necessary fixing accessories
and connection complete as required, as shown in the drawings and
as specified.
L
Type Inline,REF AHUGL-1, 6574 L/S,995 Pa static pressure
M
Type Inline,REF AHUGL 2, 5101 L/S,995 Pa static pressure
N
Type Inline, REF AHU GL-3, 3156 L/S,995 Pa static pressure.
Item Description
Item Description
HVAC SYSTEM
Item Description
Item Description
HVAC SYSTEM
Item Description
Item Description
HVAC SYSTEM
SOUND ATTENUATORS
Sound attenuator fixed on supply, and return ducts for each AHU, and
ERU to maintain room noise level as required; with all accessories
complete as specified and as shown in the drawings, and Specs.
A Ref. S/A-S-1.1 and S/A-R-1.1, with 8972 L/S air supply (for AHU 1-
1).
B Ref. S/A-S-2.1 and S/A-R-2.1, with 9469 L/S air supply (for AHU 2-
1).
C Ref. S/A-S-3.1 and S/A-R-3.1, with 9469 L/S air supply (for AHU 3-
1).
D Ref. S/A-S-4.1 and S/A-R-4.1, with 6036 L/S air supply (for AHU 4-
1).
E Ref. S/A-S-5.1 and S/A-R-5.1, with 6135 L/S air supply (for AHU 5-
1).
F Ref. S/A-S-1.2 and S/A-R-1.2, with 9211 L/S air supply (for AHU 1-
2).
G Ref. S/A-S-2.2 and S/A-R-2.2, with 5923 L/S air supply (for AHU 2-
2).
H Ref. S/A-S-3.2 and S/A-R-3.2, with 5923 L/S air supply (for AHU 3-
2).
J Ref. S/A-S-4.2 and S/A-R-4.2, with 8774 L/S air supply (for AHU 4-
2).
K Ref. S/A-S-5.2 and S/A-R-5.2, with 5994 L/S air supply (for AHU 5-
2).
Item Description
Item Description
HVAC SYSTEM
A Ref. S/A-S-GL-1 and S/A-R-GL-1, with 7311 L/S air supply (for AHU
GL-1).
B Ref. S/A-S-GL-2 and S/A-R-GL-2, with 7355 L/S air supply (for AHU
GL-2).
C Ref. S/A-S-GL-3 and S/A-R-GL-3, with 5174 L/S air supply (for AHU
GL-3).
D Ref. S/A-S-B-1 and S/A-R-B-1, with 6939 L/S air supply (for AHU B-
1).
E Ref. S/A-S-B-2 and S/A-R-B-2, with 6992 L/S air supply (for AHU B-
2).
F Ref. S/A-S-P-1 and S/A-R-P-1, with 6607 L/S air supply (for AHU P-
1).
G Ref. S/A-S-P-2 and S/A-R-P-2, with 6607 L/S air supply (for AHU P-
2).
Item Description
Item Description
HVAC SYSTEM
Item Description
Item Description
HVAC SYSTEM
Item Description
Item Description
HVAC SYSTEM
PRESSURIZATION FAN'S
Supply, Install and test the following Pressurization Fans Inline type
Complete with VFD (UL listed / FM approved), including flanges,
support framing, mounting bolts, isolating switches overload
protection, back draft damper and all necessary fixing accessories
and connection complete as required, as shown in the drawings and as
specified.
B.1
Type Inline,SPF-1, 8200 L/S, 250 Pa Total static pressure(Refer to
item no A page: 13 in Oncology Building)
B.2
Type Inline,SPF-2, 8200 L/S, 250 Pa Total static pressure(Refer to
item no A page: 13 in Oncology Building)
B.3
Type Inline,SPF-3, 7500 L/S, 250 Pa Total static pressure(Refer to
item no A page: 13 in Oncology Building)
Item Description
Item Description
HVAC SYSTEM
A
Type Roof Top, EF-1, 400 L/S, 1000 Pa static pressure(Refer to item
no D page: 13 in Oncology Building)
B
Type Roof Top, EF-2, 3550 L/S, 1325 Pa static pressure(Refer to item
no C page: 13 in Oncology Building)
C
Type Roof Top, EF-3, 1400 L/S, 1325 Pa static pressure(Refer to item
no C page: 13 in Oncology Building)
Item Description
Item Description
HVAC SYSTEMS
Ductwork
G Internal Acoustic duct lining (Hospital Grade), complete with glue and
fixing pins as required, as shown in the drawings and as specified.
H Fire rated cladding (2-hours) to smoke exhaust and make-up air duct
works, complete as required, as shown in the drawings and specified.
Item Description
Item Description
HVAC SYSTEMS
Air Outlets
D Size, 1.0 m long,5 slots with plenum box (LD5 & LD7)
E.1 Size, 0.9 m long,2 slots with plenum box (LD2C), (Mentioned in
Expansion Building But with 1.0 m / 2 slots)
E.2 Size, 0.9 m long,3 slots with plenum box (LD3C), (Mentioned in
Expansion Building But with 1.0 m / 3 slots)
E.3 Size, 0.9 m long,4 slots with plenum box (LD4C), (Mentioned in
Expansion Building But with 1.0 m / 4 slots)
E.4 Size, 0.9 m long,5 slots with plenum box (LD5C) (Mentioned in
Expansion Building But with 1.0 m / 5 slots)
Item Description
Item Description
HVAC SYSTEMS
Item Description
Item Description
HVAC SYSTEMS
Item Description
Item Description
HVAC SYSTEMS
Item Description
Item Description
HVAC SYSTEMS
Item Description
Item Description
HVAC SYSTEMS
HEPA FILTER
Item Description
Item Description
HVAC SYSTEMS
AUTOMATIC CONTROL
Item Description
C Dedicated General DDC for Fan (Size varies as per IO point list)
D Dedicated General DDC for Distribution Panel (DP) (Size varies as per
IO point list)
Item Description
Item Description
E Dedicated DDC for Lighting Control Panel ( LCP ) (Size varies as per
IO point list)
F IP Gateway/ Router
G BMS Work station with 32" LCD Screen and Event printer
Item Description
Item Description
Item Description
Item Description
Total Sum of
BILL No. 4
DIVISION 23-HEATING VENTILLATION & AIR CONDITIONING
(HVAC)
Carried to Summary
Item Description
ELECTRICAL INSTALLATIONS
General Requirements:
Price rates have to include but not limited of supply, install, testing
and commissioning of all items. Also, to includ all builder works,
reinforced concrete pads, openings, sleeves, frames, bases, sealant,
fire barrier materials, supports, Seismic restraints, formworks,
vibration isolators, marking, labels, operational and maintenance
manuals, guarantee and spare parts for all electrical equipments as
stated in the contract documents, coordination with other trades and
connection to all related systems, main feeders & infrastructure
networks including all accessories, as per drawings and
specifications.
Item Description
Item Description
ELECTRICAL INSTALLATIONS
POWER INSTALLATION
Item Description
Item Description
Item Description
Item Description
F.1 1 set x 1-4/c 35mm FIRE RATED + 1-16mm cu. grd on cable
tray. (Bill.3)
Item Description
Item Description
F 1 set x 1-4/c 6mm XLPE / LSF + 1-6mm cu. grd on cable tray.
H.2 2 set x 1-4/c 300mm XLPE / LSF + 1-150mm cu. grd on cable
tray.
H.4 1 set x 1-3.5/c 70mm XLPE / LSF + 1-35mm cu. grd on cable
tray.
Item Description
Item Description
H.8 4 sets x 1-4/c 240mm XLPE / LSF + 1-120mm cu. grd on cable
tray.
BUS BAR
Item Description
Item Description
Item Description
Item Description
PANELBOARDS
A Panelboard SWBD-12A-A
B Panelboard SWBD-12A-B
C Panelboard SWBD-12B-A
D Panelboard SWBD-12B-B
E Panelboard DP-N12A-6
F Panelboard N12A-2A
G Panelboard N12A-2B
H Panelboard N12A-S1A
J Panelboard N12A-S1B
K Panelboard N12A-6A
L Panelboard N12A-6B
M Panelboard N12A-6C
N Panelboard N12A-6D
O Panelboard N12A-6E
P Panelboard N12A-RF
Q Panelboard E12B-S1
R Panelboard E12B-1A
S Panelboard E12B-1B
T Panelboard E12B-1C
Project No. JE-1257
4/26/311
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 26
ELECTRICAL
Item Description
U Panelboard E12B-2
Item Description
A Panelboard E12B-3B
B Panelboard E12B-4C
C Panelboard E12B-5C
D Panelboard E12B-6C
E Panelboard DP-E12B-RF
F Panelboard DP-N12A-5
G Panelboard N12A-5A
H Panelboard N12A-5B
J Panelboard N12A-5C
K Panelboard N12A-5D
L Panelboard N12A-5E
M Panelboard DP-C12B
N Panelboard DP-N12B-3
O Panelboard DP-N12B-5
P Panelboard N12B-3A
Q Panelboard N12B-4A
R Panelboard N12B-3B
S Panelboard N12B-4B
T Panelboard DP-C12B-5
Item Description
U Panelboard C12B-4A
Item Description
A Panelboard C12B-4B
B Panelboard C12B-4C
C Panelboard DP-N12A-4
D Panelboard N12A-4A
E Panelboard N12A-4B
F Panelboard N12A-4C
G Panelboard N12A-4D
H Panelboard N12A-4E
J Panelboard DP-HVAC-12A-2
K Panelboard DP-HVAC-12A-S1
L Panelboard DP-HAVC-12B-2
M Panelboard DP-E12B-2B
N Panelboard DP-E12B-2A
O Panelboard DP-N12A-3
P Panelboard N12A-3A
Q Panelboard N12A-3B
R Panelboard N12A-3C
S Panelboard N12A-3D
T Panelboard N12A-3E
Item Description
U Panelboard N12A-3F
Item Description
A Panelboard DP-CU12A
B Panelboard CU12A-1A
C Panelboard CU12A-6
D Panelboard CU12A-1B
E Panelboard CU12A-1C
F Panelboard CU12A-2
G Panelboard CU12A-2
H Panelboard CU12A-3
J Panelboard CU12A-4
K Panelboard CU12A-5
L Panelboard C12B-3A
M Panelboard C12B-3B
N Panelboard C12B-3C
O Panelboard DP-C12B-3
P Panelboard LS12A-1
Q Panelboard LS12A-5
R Panelboard LS12A-3
S Panelboard LS12A-2
T Panelboard LS12A-6
Item Description
U Panelboard LS12A-4
Item Description
A Panelboard N12B-5A
B Panelboard N12B-6A
C Panelboard N12B-5B
D Panelboard N12B-6B
E Panelboard DP-LS12A
F Panelboard DP-N12B-1
G Panelboard DP-EL12B-7B
H Panelboard DP-EL12B-7A
J Panelboard N12B-1A
K Panelboard N12B-1C
L Panelboard N12B-1B
M Panelboard N12B-1D
N Panelboard N12B-1E
O Panelboard N12B-1F
P Panelboard N12B-1G
Q Panelboard E12B-4A
R Panelboard E12B-3A
S Panelboard E12B-4B
T Panelboard E12B-5A
Item Description
U Panelboard E12B-5B
Item Description
A Panelboard E12B-6A
B Panelboard E12B-6B
C Panelboard DP-N12A-1
D Panelboard N12A-1A
E Panelboard N12A-1N
F Panelboard N12A-1M
G Panelboard N12A-1L
H Panelboard N12A-1K
J Panelboard N12A-1B
K Panelboard N12A-1C
L Panelboard N12A-1D
M Panelboard N12A-1E
N Panelboard N12A-1F
O Panelboard N12A-1G
P Panelboard N12A-1H
Q Panelboard N12A-1I
R Panelboard N12A-1J
S Panelboard C12B-S1
T Panelboard DP-C12B-1
Item Description
U Panelboard C12B-1A
Item Description
A Panelboard C12B-1F
B Panelboard C12B-1E
C Panelboard C12B-1B
D Panelboard C12B-1C
E Panelboard C12B-1D
F Panelboard C12B-5A
G Panelboard C12B-5B
H Panelboard C12B-5C
J Panelboard C12B-6A
K Panelboard C12B-6B
L Panelboard C12B-6C
Item Description
Item Description
A Panelboard O-LCP-3
B Panelboard O-LCP-4
C Panelboard O-LCP-5
D Panelboard O-LCP-6
E Panelboard O-LCP-11
F Panelboard O-LCP-12
G Panelboard O-LCP-13
H Panelboard O-LCP-14
Item Description
Item Description
CONTROL PANEL
Item Description
Item Description
Item Description
Item Description
TRANSFORMERS
Dry Type, Forced air ventilation: 2000/2700 KVA; PRI 13.8 KV;
SEC 400/230V, 3PH, 4W, 60Hz.
G Ref. TR-12A
H Ref. TR-12B
Dry Type: 2500 KVA; PRI 13.8 KV; SEC 400/230V, 3PH, 4W,
60Hz.
Item Description
Item Description
MV CIRCUIT BREAKERS
Ring Main Unit (RMU), 17.5 KV, metal enclousre indoor type,
Motorized, complete as required and as shown on drawings,
specifications and workmanship.
B Ref. RMU-12A
C Ref. RMU-12B
Item Description
Item Description
POWER PROVISION
Item Description
Item Description
POWER PROVISION
Item Description
Item Description
DISCONNECT SWITCHES:
A
Disconnect switch 16A, 1PST, 220V, NEMA-1, UNFUSED.
C
Disconnect switch 16A, 3PST, 220V, NEMA-1, UNFUSED.
E
Disconnect switch 20A, 1PST, 220V, NEMA-1, FUSED.
F
Disconnect switch 20A, 3PST, 220V, NEMA-1, UNFUSED.
G
Disconnect switch 30A, 1PST, 220V, NEMA-1, UNFUSED.
J
Disconnect switch 80A, 3PST, 400V, NEMA-1, UNFUSED.
K
Disconnect switch 80A, 4PST, 400V, NEMA-1, FUSED.
L
Disconnect switch 100A, 3PST, 400V, NEMA-1, UNFUSED.
Item Description
Item Description
A
Disconnect switch 100A, 3PST, 400V, NEMA-1, FUSED.
B
Disconnect switch 125A, 3PST, 400V, NEMA-1, FUSED.
C
Disconnect switch 200A, 3PST, 400V, NEMA-1, FUSED.
D
Disconnect switch 20A, 3PST, 380V, NEMA-1, UNFUSED.
E
Disconnect switch 20A, 3PST, 400V, NEMA-1, UNFUSED.
Item Description
Item Description
Item Description
Item Description
RECEPTACLES
Item Description
Item Description
RECEPTACLES (Cont)
C Duplex receptacle, 20A, 220V, 2P grd. But listed with Hospital grade
(For TV, above false ceiling)
F Duplex receptacle, 20A, 220V, 2P grd. But listed with Tamper Resistance
(For T.V)
Item Description
Item Description
RECEPTACLES (Cont)
Item Description
RECEPTACLES (Cont)
A
Duplex receptacle, 230V, 20A, 2P+E, mounted above counter, wired to
critical branch power circuit and with different color from the normal to
be identifiable, (For REF),(weatherproof),IP66.
Item Description
Item Description
RECEPTACLES (Cont)
Item Description
Item Description
LIGHTINGS
A Lighting points
H Type - F1
J Type - F2
K Type- F3
L Type- F4
M Type- F12
N Type- F16
O Type- F17
P Type- F21
Item Description
Item Description
LIGHTINGS (Cont)
A Type- F23
B TYPE-F24
C Type -F31
D Type -CL-1
E Type -J
F Type- SL1
G Type -SL2
H Type -PL-1
J Type- PL8
K Type PL23
L TYPE-RF-4
M TYPE-RF5
N TYPE-RF-8
N.1 TYPE-RF8
O Type- DC-1
P Type- DC-2
Q Type- DC-3
R Type -DC8
S Type -DC9
Project No. JE-1257
4/26/356
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 26
ELECTRICAL
Item Description
T Type- DC10
U Type- DC11
Item Description
LIGHTINGS (Cont)
A Type- DC12
B Type- DC13
C Type- DC-14
D Type- DC14A
E Type -DC15
F Type- DC21
G Type- DC22
H TYPE-XR1C
J TYPE-BL24A
J.1 TYPE-PL24A
K Type -WS2
L Type -WS3
M Type- WS4
N Type -EX1
O Type- EX2
P Type -EX3
Q Type- EX4
R Type- EX5
Item Description
S Type -XUE-1
T Type- XUE-2
Item Description
LIGHTINGS (Cont)
A Type -XST-1
B Type -XFM-3
C Type -XFM-4A
D Type- XFM-4B
E Type -XFM-4C
F Type -XFM-5
G Type-R1
H Type-EB
J TYPE-UL3
J.1 TYPE-UL2
K TYPE-F32
L TYPE-XLE-2
M TYPE-XBC-1
N TYPE-XNE-1
P
Led drivers for building Faade Lighting Control 150W
Q
Led drivers for building Faade Lighting Control 120W
R
Led drivers for building Faade Lighting Control 100W
Item Description
Item Description
LIGHTINGS (Cont)
A Type- A1
B Type- A17
C Type- A24
D Type- CL-4
E Type- LF-1
F Type- LF--2
G Type- LF-3
H Type- LF-4
J Type- PL-10A
K Type- PL-24
L Type- PL-27
M Type- RF-10
N Type- RF-10A
O Type- RF-11
P Type- RF-14D
Q Type- RF-14A
R Type- RF-15
Project No. JE-1257
4/26/362
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 26
ELECTRICAL
Item Description
S Type- RF-16
Item Description
LIGHTINGS (Cont)
A Type- RF-18
B Type- RF-20
C Type- RF-24
D Type- RF-26
E Type- RF-28
F Type- TL-1
G Type- W-24
H Type- OB-1
J Type- XAM-1
K Type- XAM-2
L Type- XBM-1
M Type- XBO-1
N Type- XBO-2
O Type- XBO-3
P Type- XBO-4
Q Type- XDE-1
R Type- XNE-2
S Type- XPO-1
T Type- XUE-3
U Type- XUE-4A
V Type- XUM-1
W Type- XWM-1
X Type- XWE-1A
Project No. JE-1257
4/26/364
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 26
ELECTRICAL
Item Description
Y Type- XWE-1B
Z Type- XWE-1C
Item Description
SWITCHES:
A
Single pole toggel switch (Switch,one way, one gang, 20A, 230V)
C
Two pole toggle switch (Switch,one way, two gang, 20A, 230V)
E
Two way toggle switch (Switch, three way, one gang, 20A, 230V)
K Dimming Station
Item Description
Item Description
B GPS antenna
C Photo-electric controller
D junction box
Item Description
Item Description
L
25mm x 3mm copper tape installed on the top of parapet, walls,
roof, etc., including intersection (for lightning).
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Item Description
Total Sum of
BILL No. 4
DIVISION 26 - ELECTRICAL
Carried to Summary
Item Description
General Requirements:
Price rates have to include but not limited all Builder works,
reinforced concrete pads, openings, sleeves, frames, bases, sealant,
fire barrier materials, supports, formwork, vibration isolators,
marking, labels, operational and maintenance manuals, guarantee
and spare parts for all electrical equipments as stated in the contract
documents, Cable trunks & Ladders C/W all their accessories,
Grounding and bounding of all technology system, coordination
with other trades and connecting to all systems and also connecting
the technology cabling infrastructure installations to site OSP&
connection to STC & all related external work including all
accessories as per the standard, specifications and drawings.
Item Description
E Speaker 6 watt
Item Description
BILL No. 4
DIVISION 27 - COMMUNICATIONS
Carried to Summary
Item Description
General Requirements:
Price rates have to include but not limited all Builder works,
reinforced concrete pads, openings, sleeves, frames, bases, sealant,
fire barrier materials, supports, formwork, vibration isolators,
marking, labels, operational and maintenance manuals, guarantee
and spare parts for all electrical equipments as stated in the contract
documents, Cable trunks & Ladders C/W all their accessories,
Grounding and bounding of all technology system, coordination
with other trades and connecting to all systems and also connecting
the technology cabling infrastructure installations to site OSP&
connection to STC & all related external work including all
accessories as per the standard, specifications and drawings.
Item Description
Item Description
A Sub fire alarm control panel SFACP6 (12 loops + 1 loop Spare)
class A intelligent type, auto dialer, interfaces to BAS with Backnet
protocol, HVAC, elevator, public address and BMS system with
built in SLA battery and battery charger.
C Events printer
C.3 Fire alarm control panel Addressable type with built in SLA
battery and battery charger .
Item Description
Item Description
K
Fixed temperature heat detector (Addressable heat detector)
Item Description
Item Description
O battery
Item Description
Item Description
Item Description
Item Description
BILL No. 4
DIVISION 28 - ELECTRONIC SAFETY & SECURITY
Carried to Summary
EXCAVATION WORK
Excavation
SOIL TREATMENT
OPTION -1
SHORING SYSTEM
OPTION -2
SHORING SYSTEM
COLLECTION
From
Page