Académique Documents
Professionnel Documents
Culture Documents
then multi-
multi-bay/storey option
Select :
10m for L;
8m for W &
4.2m for H
1
Select :
Generate
Generate
then 9 extra
values
(incl.
present
one!) for an
11-
11-storey
frame
Select :
Columns
Columns
then
change
Group
Group to
UC
UCs
2
Select :
150UC30
150UC30
for
columns
then press
OK
OK
Note that
frame
member
colours
distinguish
section
properties
(columns diff.
to beams).
3
Use left button to
click onto
onto the
beam on the top-
top-
storey (now
highlighted) then
click right button
to expose drop-
drop-
down menu and
select member
concentrated
loads
loads
Enter a 1 for
Load case 1
then click
onto OK
OK
4
Select -10kN in the z-direction
direction and 25%
then click OK
OK
Select linear
static
analysis
analysis
from the drop-
drop-
down menu of
the
Analysis
Analysis
button
5
Then OK
OK
from the
drop-
drop-down
menu that
follows
Pop-
Pop-down screen
portions provide a
description of the
analysis, and a
warning OK
warning OK
6
Click the right
mouse button to
expose the pop-
pop-
down menu and
select zoom
zoom
Then zoom
window
window
7
Use the left mouse
button to drag a
window over the
top few storeys
8
Introduce a 1 or leave
blank
blank the entry for the
pop-
pop-down menu that
results from the last action
9
Left Mouse click onto the next node to obtain
displacement results ..
..
Right click mouse button to stop
stop the process
10
Drag whilst holding down the Left Mouse click
to select the three nodes on the top storey
Then select OK
OK
from the pop-
pop-up
menu
11
Left Mouse click onto the z-x contraint menu of
the Edit node properties
properties pop-
pop-up menu that is
produced then the select
select option for the
Master node
12
Perform a re-
re-analysis ( Analysis linear
(Analysis
Static
Static, OK
OK)
13
Then select node 4545 one of the slaves
slaves and
notice that Ry
Ry the same and results look
different to original (when storey not contrained)
contrained)
Introduce a self-
self-weight
weight load Case
14
Define it as Load Case 2 with default of -1 x g
acting in y-direction
direction then OK
OK
15
Define it as Load Case 3 with factors of 1.0 on
each of Load Cases 1 and 2 (ie
(ie LC3 = 1LC1+1LC2
then OK
OK
Perform a re-
re-analysis of all load cases under
Query Analysis Results
Linear Static then Query Results
and clear the entry in the above pop-
pop-up menu
Blank all
all option
16
Select the unnamed LC3
LC3 option from
the display window menu
17
Perform a re-
re-analysis of all load cases under
Non- Query Analysis
Non-Linear Static then Query
Results
Results
Select node 47
47 the master
master to observe no
longer have linear
linear combination of output
18