Sewerage Hydraulic Design Calculation - Overall

Adopt n = 0.012

Flow Computation Pipe Computation Manhole and level Computation

Pipe Velocity

Capacity (Q)
Area of Pipe

Perimeter of

Invert Level
Waste Flow

Roughness
Cumulative

Pipe length
Equilvalent
Population

Population

Coefficient

Pipe Invert
Equivalent

Level (GL)
Peak Flow

Peak Flow

Level (IL)
Diameter

Remarks
Pipe Fall
Gradient

Gradient
Manhole

Manhole

Manhole
Ground

Type of
Design

(WWF)
Factor

(DWF)

Depth
(MH)

Pipe

Pipe

Pipe

Pipe
(V)
P.E. P.E. f (/s m3/s mm m2 m S 1:S n m/sec m3/sec m m m m m m
1 3.000 1.800 1.800 1.200 A
270 270 5.43 0.70 0.004 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.231 46.1 VCP Pipe
3 3.000 1.570 1.560 1.440 E

2a 3.000 1.800 1.800 1.200 A


640 640 4.94 1.67 0.008 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.065 13.097 VCP Pipe
2 3.000 1.735 1.735 1.265 C
0 640 4.94 1.67 0.008 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.174 34.88 VCP Pipe
3 3.000 1.560 1.560 1.440 E

3 3.000 1.560 1.560 1.440 E


0 910 4.75 2.37 0.011 225 0.040 0.707 150 0.0067 0.012 0.999 0.0397 0.131 19.7 VCP Pipe
4 3.000 1.429 1.429 1.571 C
0 910 4.75 2.37 0.011 225 0.040 0.707 150 0.0067 0.012 0.999 0.0397 0.070 10.478 VCP Pipe
5 3.000 1.359 1.359 1.641 C
0 910 4.75 2.37 0.011 225 0.040 0.707 150 0.0067 0.012 0.999 0.0397 0.171 25.59 VCP Pipe
11 3.000 1.188 0.570 2.430 E (Drop manHOle)

6 3.000 1.600 1.600 1.400 A


3700 3700 4.07 9.64 0.039 300 0.071 0.942 250 0.0040 0.012 0.937 0.0663 0.192 48 VCP Pipe
7 3.000 1.408 1.408 1.592 B
301 4001 4.04 10.42 0.042 300 0.071 0.942 250 0.0040 0.012 0.937 0.0663 0.216 54 VCP Pipe
8 3.000 1.192 1.192 1.808 C
0 4001 4.04 10.42 0.042 300 0.071 0.942 250 0.0040 0.012 0.937 0.0663 0.102 25.5 VCP Pipe
9 3.000 1.090 1.090 1.910 C
753 4754 3.96 12.38 0.049 300 0.071 0.942 250 0.0040 0.012 0.937 0.0663 0.260 65 VCP Pipe
10 3.000 0.830 0.830 2.170 B
0 4754 3.96 12.38 0.049 300 0.071 0.942 250 0.0040 0.012 0.937 0.0663 0.260 65 VCP Pipe
11 3.000 0.570 0.570 2.430 E

11 3.000 0.570 0.570 2.430 E


0 5664 3.88 14.75 0.057 300 0.071 0.942 200 0.0050 0.012 1.048 0.0741 0.308 61.571 VCP Pipe
12 3.000 0.262 0.262 2.738 B
0 5664 3.88 14.75 0.057 300 0.071 0.942 200 0.0050 0.012 1.048 0.0741 0.308 61.571 VCP Pipe
17 3.000 -0.046 -0.046 3.046 E

13 3.000 1.800 1.800 1.200 A


372.5 372.5 5.24 0.97 0.005 300 0.071 0.942 225 0.0044 0.012 0.988 0.0698 0.349 78.484 VCP Pipe
14 3.000 1.451 1.451 1.549 B
0 372.5 5.24 0.97 0.005 300 0.071 0.942 225 0.0044 0.012 0.988 0.0698 0.356 80 VCP Pipe
15 3.000 1.096 1.096 1.904 B
0 372.5 5.24 0.97 0.005 300 0.071 0.942 225 0.0044 0.012 0.988 0.0698 0.356 80 VCP Pipe
16 3.000 0.740 0.740 2.260 B
0 372.5 5.24 0.97 0.005 300 0.071 0.942 225 0.0044 0.012 0.988 0.0698 0.356 80 VCP Pipe
17 3.000 0.385 -0.046 3.046 E

17 3.000 -0.046 -0.046 3.046 E


0 6036.5 3.86 15.72 0.061 300 0.071 0.942 200 0.0050 0.012 1.048 0.0741 0.218 43.62 VCP Pipe
18 2.500 -0.264 -0.264 2.764 C
0 6036.5 3.86 15.72 0.061 300 0.071 0.942 200 0.0050 0.012 1.048 0.0741 0.180 35.954 VCP Pipe
24 2.500 -0.444 -0.444 2.944 E

19 3.000 1.800 1.800 1.200 A


372.5 372.5 5.24 0.97 0.005 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.226 45.2 VCP Pipe
20 3.000 1.574 1.574 1.426 D
0 372.5 5.24 0.97 0.005 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.377 75.31 VCP Pipe
21 3.000 1.197 1.197 1.803 B
0 372.5 5.24 0.97 0.005 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.422 84.388 VCP Pipe
22 3.000 0.776 0.776 2.224 B
0 372.5 5.24 0.97 0.005 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.404 80.89 VCP Pipe
23 3.000 0.371 0.371 2.629 C
0 372.5 5.24 0.97 0.005 225 0.040 0.707 200 0.0050 0.012 0.865 0.0344 0.048 9.515 VCP Pipe
24 2.500 0.323 -0.444 2.944 E (Drop Manhole)

24 2.500 -0.444 -0.444 2.944 E


0 6409 3.83 16.69 0.064 300 0.071 0.942 175 0.0057 0.012 1.120 0.0792 0.123 21.6 VCP Pipe
Existing 2.500 -0.567 -0.714 3.150 G

Note :
(a) Manning n value ranges from 0.010 - 0.017 for new pipes, usually n = 0.011 is adopted, however, for conservative purpose, n = 0.012 is adopted

(b) The Sewerage Reticulation is designed to cater for whole development.