Guy
Cables

Here is some information that resulted from my research into guy cables to support my
tower modeling efforts. The object of my research was to arrive at values for the cable
diameter and elastic modulus that would provide accurate stretch behavior in the cables for
use in the FEA tower models.

Steel Wire Rope


The following information was derived using published information from the Macwhyte Wire Rope
Company, Kenosha, WI.

To obtain the equivalent area of a solid wire (to be used in the tower models) to represent any
multiple wire construction we use the following formula:

A = (100*D^2) / (F*E)
Where: A = the equivalent area
D = the nominal wire rope diameter
E = the elastic modulus of the steel
F = The factor provided by Macwhyte for each cable construction.
Different factor for each construction.

The elastic modulus for steel is widely accepted to be around 29 MSI (million psi). Using this value
we obtain the following equivalent areas for steel wire constructions:

Nominal Equivalent Equivalent


Wire Construction Factor Area Diameter Equivalent
Size SqIn In. Dia

1 of 5
% of
In. Nominal
Dia
3/16 1x7 6.61E-06 .01834 .1528 81.5%
3/16 1 x 19 6.98E-06 .01737 .1487 79.3%
3/16 7x7 1.07E-05 .01133 .1201 64.1%
3/16 7 x 19 1.40E-05 .00866 .1050 56.0%
1/4 1x7 6.61E-06 .03261 .2037 81.5%
1/4 1 x 19 6.98E-06 .03088 .1983 79.3%
1/4 7x7 1.07E-05 .02014 .1601 64.1%
1/4 7 x 19 1.40E-05 .01539 .1400 56.0%
5/16 1x7 6.61E-06 .05095 .2547 81.5%
5/16 1 x 19 6.98E-06 .04624 .2478 79.3%
5/16 7x7 1.07E-05 .03147 .2002 64.1%
5/16 7 x 19 1.40E-05 .02405 .1750 56.0%

It is readily apparent that the 1 x 7 construction has the largest equivalent area and hence,
stiffness. EHS guy cables for towers use this construction. It is harder to form around the thimbles
etc., guy grips eliminate this handling problem. The other constructions are designed to be more
flexible for running over sheaves, like in crankup towers, but we don't want to use them for guying
towers.
The reductions in the equivalent diameters are caused by the fact that there is less material in the
construction than a solid wire at the nominal size and the degree of twist built into the wire
construction. It is my understanding that the factors were derived from laboratory testing of the
product.

Aramid Cables
Aramid cables are made from non-conductive synthetic fibers commonly known as Kevlar (TM).
There are two common Kevlar compounds used for cable construction. The first and most common
is Kevlar 49, the other is Kevlar 149. The information I have indicates the elastic modulus of the
Kevlar 49 is around 18 MSI (Million PSI) and the Kevlar 149 is around 25 MSI. It is my guess that
most of the aramid cable offered to the cost conscious amateur buyer is made from the cheaper
Kevlar 49. The Kevlar 149 is stiffer but not as strong as the 49. The 149 is available in certain cable
sizes rated at 8600 - 32500 Lb breaking strengths. It is not likely an amateur tower builder will get it
from the normal outlets, unless specifically ordered. It is a readily available cable in the marine
industry for applications that require the increased stiffness.

The following table presents equivalent diameter derivations made from the Philadelphia Resins
Corp. Technical bulletin NO. 320-5/80.
The bulletin presents stress-strain plots for various cables and does not state which Kevlar
compound is used in the cable. I have assumed that it represents the Kevlar 49 @ 18 MSI elastic
modulus. This assumption does not introduce any unexpected error, as the plots show elongation
vs load, and either choice of modulus would result in the same net elogation reported in the

2 of 5
document. They would just arrive at the same elongations via different effective diameters.

The values were determined by finding the average equivalent diameter for 18 Msi modulus
material across the range of the linear plots.
The technical bulletin did not include the HPTG6700 cable. Its equivalent diameter was calculated
using the average reduction from nominal cable size found in the larger cables presented in the
plots.
The nominal Kevlar fiber bundle diameters were taken from data published by Aramid Rigging Inc.,
Portsmouth, RI., 10/96, a supplier to the marine industry for these cables.
The actual OD measurements of the cable are .063 - .070 In. larger when measuring the jacket.

Nominal Fiber Average


% of Nominal
Bundle Solid
Cable Type Fiber Bundle
Diameter Diameter
Diameter
In. In.
HPTG15400 .36 .2272 63.1%
HPTG11200 .32 .2161 67.5%
HPTG8000 .29 .1692 58.3%
HPTG6700 .22 .1389 63.1%

The preceeding information got me what I needed to make the tower models and is presented to
document how the values were derived.

Fiberglass Rod
Fiberglass Reinforced Plastic (FRP) meets our requirement for non-conductive guy material. There
is "fiberglass" (used for highly stressed aerospace structures) and there is "fiberglass" (used to
make your bathtub), and a lot of stuff in between.

There are different types of glass filament alloys, some have average strength like E-Glass made
for electrical and general purpose applications, and there are high strength alloys, like S2 Glass
made for high strength applications. There are also a multitude of resin systems applied to these
fibers in a multitude of processes to obtain an even wider variety of properties.
So, when we talk about fiberglass we need to be exceptionally careful to quantify the constituent
materials and their process to get in the right material properties ballpark.

Add to that, some processors and resin formulators are more clever than others and get better
properties than others.
The important point is that "Fiberglass" has the highest diversity of processes and properties of
any of the materials we use. So, care should be exercised when ordering these materials. Be
absolutely sure to obtain guaranteed minimum material properties.

3 of 5
Current information indicates that the use of FRP rods as tower guys has been confined to rods
produced by the Pultrusion process. This is similar to the extrusion process for some metals. It is a
low cost continuous line process. Most of the fibers are aligned with the axis of the rod providing
the hghest axial strength and lowest axial elongation. There are numerous manufacturers of FRP
rod with this process.
It is my opinion that this is the best process for FRP stock for this application.
The rods can be terminated with Glas Grips made by the same company that makes the Big Grips.

Guy Cable Comparisons


A comparison of the cables under load will make the information more meaningful.
A 3000 Lb load is applied to the cables and the elongation is calculated for a 100 Ft length of each
cable.

Nominal Breaking Weight


Elongation %
Cable Diameter Strength per 100'
Per 100' Elongation
In. Lbs Lbs
3/16" 1 x 7
.1875 3990 7.3 6.77 .56%
EHS
1/4" 1 x 7
.25 6700 12.1 3.81 .32%
EHS
HPTG6700 .22 6700 3.1 13.20 1.10%
HPTG8000 .29 8000 3.5 8.90 .74%
5/16" 1 x 7
.31 11200 20.5 2.44 .20%
EHS
HPTG11200 .32 11200 5.5 5.45 .45%
3/8"
.375 13000 9.7 5.43 .45%
Fiberglass
HPTG15400 .36 15400 6.9 4.93 .41%

Note:
The fiberglass rod information is based on a polyester/"E" Glass pultruded rod that has a tensile
strength of 120 Ksi, Tensile modulus of 6.0 Msi, and a density of .073 Lb/CuIn. Be sure to ask for
the properties listed to get something that will perform according to this comparison.

Back to Back to Tower

4 of 5
Notebook Study

As, is customary with everything on this website, I only offer comments to stimulate thought, and hopefully help fellow
Amateurs. None of the information provided is authoritative in any manner or guaranteed to be correct. The reader is
encouraged to research these subjects and make his own determinations about these things, before trying to apply them
in the real world.

Updated July 7, 2001