Vous êtes sur la page 1sur 1

ELEMENT DESIGN to BS 8110:2005

SOLID SLABS
Originated from RCC11.xls v4.0 2006 - 2010 TCC

INPUT Location D&D: interior span solid slab


Design moment, M 216.0 kNm/m fcu 40 N/mm c 1.50
b 1.00 fy 500 N/mm s 1.15
span 6500 mm steel class A
Height, h 1000 mm Section location CONTINUOUS SPAN
Bar 20 mm Compression steel NONE
cover 50 mm to these bars (deflection control only)
ONE or TWO WAY SLAB
OUTPUT D&D: interior span solid slab Compression steel = NONE
d = 1000 - 50 - 20/2 = 940.0 mm .
(3.4.4.4) K' = 0.156 > K = 0.006 ok .
(3.4.4.4) z = 940.0 [0.5 + (0.25 - 0.006 /0.893)]^ = 933.6 > 0.95d = 893.0 mm
(3.4.4.1) As = 216.00E6 /500 /893.0 x 1.15 = 556 < min As = 1300 mm/m
PROVIDE H20 @ 225 = 1396 mm/m .
(Eqn 8) fs = 2/3 x 500 x 556 /1396 /1.00 = 132.8 N/mm
(Eqn 7) Tens mod factor = 0.55 + (477 - 132.8) /120 /(0.9 + 0.244) = 2.000
(3.4.6.3) Permissible L/d = 26.0 x 2.000 = 52.000
. Actual L/d = 6500 /940.0 = 6.915 ok .
. .