Académique Documents
Professionnel Documents
Culture Documents
1/336
Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
SCHEDULE C
LIST OF PARALLEL RATE CONTRACT FOR ITEM- RCC HUME PIPE
S.No. Name of the RC Holding Firm Valid Dated Rate Contract No.
1 2 3 4
01 M/s Aditya Industries, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
C/o Dhansiram Bhajankumar, Rupdev Market, To /102/510/14-15/RCCHP/AI/6467
Deviganj Road, Ambikapur Distt.- Surguja 01-04-2016
(C.G.) 497001 Mo.- 9425256300
Email- bhajan agrwal@yahoo.com
02 M/s Surguja Cement Pipe Industries, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Manendragarh Road, Ambikapur Distt.- Surguja To /102/510/14-15/RCCHP/SCPI/6468
(C.G.) 497001 Mo.- 9425256300, 9826956300 01-04-2016
Email- bhajan agrwal@yahoo.com
03 M/s Raigarh Hume & Spun Pipe, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Near Stadium, Industrial Area Raigarh (C.G.) To /102/510/14-15/RCCHP/RH&SP/6469
Mo.- 9300676323, 9301010290 01-04-2016
Email- raigarhhume@gmail.com
04 M/s Dhanshri & Company, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Deviganj Road Ambikapur Surguja (C.G.) To /102/510/14-15/RCCHP/D&C/6470
497001 Mo.- 09425580211 Ph.- 07774-235611 01-04-2016
05 M/s Agrasen Concrete Products, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Navagarh Road, Bemetara Distt- Durg (C.G.) To /102/510/14-15/RCCHP/ACP/6471
Mo.- 9977700300 01-04-2016
06 M/s Gopesh Cement Arts, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Dayalband Bilaspur (C.G.) To /102/510/14-15/RCCHP/GCA/6472
Mo.- 9300325947, 9827485186 01-04-2016
Email- kesarygca@gmail.com
07 M/s Radheshyam Benishyam Kesary & Co., 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Dayalband Bilaspur (C.G.) To /102/510/14-15/RCCHP/RBK&C/6473
Mo.- 9827167998, 9300333354 01-04-2016
Email- kesaryb@gmail.com
08 M/s Bilaspur Cement Products, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
C/O Shri Sai Teles & Sanitary Main Road To /102/510/14-15/RCCHP/BCP/6474
Tarwa Naka Bilaspur (C.G.) 495001 01-04-2016
Mo.- 9425219302 9893968974
Ph.-07752-410302
09 M/s Vasudev Shamji Savaria, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Bajirao Mehrapara Raigarh (C.G.) 496001 To /102/510/14-15/RCCHP/VSS/6475
Ph.- 07762-220050 Mo.- 099267-42045 01-04-2016
Email- ravi.savaria@rediffmail.com
10 M/s Dinesh Industries, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Telibandha, Near Gali No.- 6, Ravigram, Raipur To /102/510/14-15/RCCHP/DI/6476
Factory 730 A Industrial Estate Urla Raipur 01-04-2016
(C.G.) 492001 Ph.- 0771-3265888
Mo.- 9755042331 , 9926156001
No. 2/336
11 M/s Quality Cement Pipes, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Add : 11,12 Industrial Estate To /102/510/14-15/RCCHP/QCP/6477
Bhanpuri Raipur (C.G.) 493221 01-04-2016
Ph.- 0771-4024190, Mo.- 9752005557
12 M/s Raj Pipe, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Infront of Industrial Estate, G.E. Road, To /102/510/14-15/RCCHP/RP/6478
Rajnandgaon (C.G.) 01-04-2016
13 M/s Akash Pipe Industries, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Dharampara Mungeli Bilaspur (C.G.) 495334 To /102/510/14-15/RCCHP/API/6479
Mo.- 9993070099 01-04-2016
14 M/s Korba Cement Products, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Urga-Korba (C.G.) Mo.- 9425224499 To /102/510/14-15/RCCHP/KCP/6480
Email- korbacementproducts@yahoo.in 01-04-2016
15 M/s Dhansree Concrete Products, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Manendragarh Road Ambikapur (C.G.) 497001 To /102/510/14-15/RCCHP/DCP/6481
Mo.- 9425580211 01-04-2016
16 M/s Shivshakti Industries, 31-03-2015 Rate Contract No. CSIDC/MKD/PS-VII
Kena Bandh Bouripara, Ambikapur, Distt Surguja To /102/510/14-15/RCCHP/SI/6482
(C.G.) 497001 Mo.-9425582023 01-04-2016
17 M/s Jai Mahamaya Cement Pipe Industries, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Mission Chowk, Ring Road, Ambikapur Distt.- To /102/510/15-16/RCCHP/JMCPI/6483
Surguja (C.G.) 497001 Mo.- 9826122358 01-04-2016
Email- alokjaiswal.pcc@gmail.com
18 M/s Jai Ambe Cement Product, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Vill-Sargawan, Teh.-Ambikapur Distt.- Surguja To /102/510/15-16/RCCHP/JACP/6484
(C.G.) 497001 Mo.- 9826122358, 9425254259 01-04-2016
19 M/s Jaiswal Cement Products, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Mission Chowk, Ring Road, Ambikapur To /102/510/15-16/RCCHP/JCP/6485
Distt.- Surguja (C.G.) 497001 01-04-2016
Mo.- 9826122358 , 9425254259
Email- alokjaiswal.pcc@gmail.com
20 M/s Bhilai Cement Pipe Manufacturing co., 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
70-A,Industrial Estate , Nandini Road, Bhilai To /102/510/15-16/RCCHP/BCPMC/6486
(C.G.) Ph- 0788-2286518 01-04-2016
Mo.- 9893115028, 9981125028
21 M/s Bhawani Cement Pipe Industries, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Kh.No-521 D 1, Om Complex, Fafadih Village To /102/510/15-16/RCCHP/BCPI/6487
Deori Bilaspur Road Raipur (C.G.) 492001 01-04-2016
Ph.-07714092724, Mo.- 9425507207
22 M/s Bastar Cement Products, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Geedam Road, P.O Pandripani, Jagdalpur To /102/510/15-16/RCCHP/BCP/6488
(Bastar) 494001 Mo.- 9826612012, 9425212012 01-04-2016
Email- gggrewaljitender@gmail.com
23 M/s Engineers Enterprises, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Rawabhata Industrial Area P.O. Birgaon Raipur To /102/510/15-16/RCCHP/EE/6489
(C.G.) 493221 Mo.-9826612012, 9425212012 01-04-2016
Email- grewaljitender@gmail.com
24 M/s Grewal Cement Pipe Industries, 10-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
31 Industrial Area, P.O Birgaon- 493221 To /102/510/15-16/RCCHP/GCPI/6490
Raipur (C.G.) Mo.- 9826612012, 9425212012 01-04-2016
Email- grewaljitender@gmail.com
No. 3/336
25 M/s R.C.C. Hume Pipe & Products, 30-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
S.U.I.E. Frazerpur Nayamundapara , Industrial To /102/510/15-16/RCCHP/RCCHP&P/6491
Estate, Jagdalpur Bastar (C.G.) 01-04-2016
Ph.- 07782227204, Mo.-9425260321,9406286611
Email- vijaykumaragarwal.47@gmail.com
26 M/s Chhattisgarh Pipe Industries, 30-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Village - Bhoinabhata Tah. & Distt. To /102/510/15-16/RCCHP/CPI/6492
Bemetara (C.G.) Mo.- 9993730777 01-04-2016
27 M/s Star Industries, 30-04-2015 Rate Contract No. CSIDC/MKD/PS-VII
Mukhtiyarpara Nagpur To /102/510/15-16/RCCHP/SI/6493
Manendragarh Korea (C.G.) 01-04-2016
Mo.- 09424260460, 09993251066
(Suresh Keshi)
General Manager
No. 4/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Aditya Industries,
C/o Dhansiram Bhajankumar, Rupdev Market,
Deviganj Road, Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9425256300
Email- bhajan agrwal@yahoo.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 5/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 6/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Aditya Industries,
THE FIRM C/o Dhansiram Bhajankumar, Rupdev Market,
Deviganj Road, Ambikapur Distt.- Surguja (C.G.)
497001 Mo.- 9425256300
Email- bhajan agrwal@yahoo.com
(Suresh Keshi)
General Manager
No. 7/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of
the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment Nominal Diameter of Pipes in mm.
18 RCCHPF80001087 150 202.08
19 RCCHPF80001091 300 415.80
20 RCCHPF80001092 350 462.00
21 RCCHPF80001093 400 485.10
22 RCCHPF80001094 450 1037.84
23 RCCHPF80001095 500 1239.91
24 RCCHPF80001096 600 1386.00
25 RCCHPF80001097 700 1732.50
26 RCCHPF80001099 900 2772.00
27 RCCHPF80001100 1000 3291.75
28 RCCHPF80001101 1100 3407.25
29 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
30 RCCHPF80001148 Upto 50 Km. 19.64
31 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
32 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
33 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
34 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 8/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 9/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 10/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 11/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 12/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 13/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 14/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 15/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/AI/6467 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 16/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Surguja Cement Pipe Industries,
Manendragarh Road Ambikapur
Distt.- Surguja (C.G.) 497001
Mo.- 9425256300, 9826956300
Email- bhajan agrawal@yahoo.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 17/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 18/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Surguja Cement Pipe Industries,
THE FIRM Manendragarh Road Ambikapur
Distt.- Surguja (C.G.) 497001
Mo.- 9425256300, 9826956300
Email- bhajan agrawal@yahoo.com
(b) NAME AND FULL ADDRESS OF :- M/s Surguja Cement Pipe Industries,
MANUFACTURER Manendragarh Road Ambikapur
Distt.- Surguja (C.G.) 497001
Mo.- 9425256300, 9826956300
Email- bhajan agrawal@yahoo.com
(Suresh Keshi)
General Manager
No. 19/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 20/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 21/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 22/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 23/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
2. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 24/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 25/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 26/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 27/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SCPI/6468 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 28/336
Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Raigarh Hume & Spun Pipe,
Near Stadium, Industrial Area Raigarh (C.G.)
Mo.- 9300676323, 9301010290
Email- raigarhhume@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 29/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 30/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Raigarh Hume & Spun Pipe,
THE FIRM Near Stadium, Industrial Area Raigarh (C.G.)
Mo.- 9300676323, 9301010290
Email- raigarhhume@gmail.com
(b) NAME AND FULL ADDRESS OF :- M/s Raigarh Hume & Spun Pipe,
MANUFACTURER Near Stadium, Industrial Area Raigarh (C.G.)
Mo.- 9300676323, 9301010290
Email- raigarhhume@gmail.com
(Suresh Keshi)
General Manager
No. 31/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 32/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 33/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 34/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 35/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
3. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 36/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 37/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 38/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 39/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RH&SP/6469 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 40/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Dhanshri & Company ,
Deviganj Road Ambikapur Surguja (C.G.) 497001
Mo.- 09425580211 Ph.- 07774-235611
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 41/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 42/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Dhanshri & Company ,
THE FIRM Deviganj Road Ambikapur Surguja (C.G.) 497001
Mo.- 09425580211 Ph.- 07774-235611
(Suresh Keshi)
General Manager
No. 43/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 44/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 45/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 46/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 47/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 48/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6473 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
4. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 49/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 50/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 51/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 52/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/D&C/6470 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 53/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Agrasen Concrete Products,
Navagarh Road, Bemetara Distt- Durg (C.G.)
Mo.- 9977700300
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 54/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 55/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Agrasen Concrete Products,
THE FIRM Navagarh Road, Bemetara Distt- Durg (C.G.)
Mo.- 9977700300
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 57/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
(Suresh Keshi)
General Manager
No. 58/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 59/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 60/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
5. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 61/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 62/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 63/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 64/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/ACP/6471 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 65/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Gopesh Cement Arts,
Dayalband Bilaspur (C.G.)
Mo.- 9300325947, 9827485186
Email- kesarygca@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 66/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 67/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Gopesh Cement Arts,
THE FIRM Dayalband Bilaspur (C.G.)
Mo.- 9300325947, 9827485186
Email- kesarygca@gmail.com
(Suresh Keshi)
General Manager
No. 68/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 69/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 70/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
(Suresh Keshi)
General Manager
No. 71/336
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 72/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 73/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
6. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 74/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 75/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 76/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 77/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/GCA/6472 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 78/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Radheshyam Benishyam Kesary & Co.,
Dayalband Bilaspur (C.G.)
Mo.- 9827167998 , 9300333354
Email- kesaryb@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 79/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 80/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Radheshyam Benishyam Kesary & Co.,
THE FIRM Dayalband Bilaspur (C.G.)
Mo.- 9827167998, 9300333354
Email- kesaryb@gmail.com
(b) NAME AND FULL ADDRESS OF :- M/s Radheshyam Benishyam Kesary & Co.,
MANUFACTURER Dayalband Bilaspur (C.G.)
Mo.- 9827167998 , 9300333354
Email- kesaryb@gmail.com
(Suresh Keshi)
General Manager
No. 81/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 83/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 84/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 85/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 86/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
7. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 87/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 88/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 89/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 90/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RBK&C/6473 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 91/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Bilaspur Cement Products,
C/o Shri Sai Teles & Sanitary Main Road
Tarwa Naka Bilaspur (C.G.) 495001
Mo.- 9425219302, 9893968974
Ph.-07752-410302
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 92/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 93/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bilaspur Cement Products,
THE FIRM C/o Shri Sai Teles & Sanitary Main Road
Tarwa Naka Bilaspur (C.G.) 495001
Mo.- 9425219302, 9893968974
Ph.-07752-410302
10. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 94/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 95/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 96/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 97/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 98/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
8. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 99/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 100/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 101/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 102/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/BCP/6474 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 103/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Vasudev Shamji Savaria,
Bajirao Mehrapara Raigarh (C.G.) 496001
Ph.- 07762-220050 Mo.- 099267-42045
Email- ravi.savaria@rediffmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 104/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 105/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Vasudev Shamji Savaria Bajirao,
THE FIRM Mehrapara Raigarh (C.G.) 496001
Ph.- 07762-220050 Mo.- 099267-42045
Email- ravi.savaria@rediffmail.com
(b) NAME AND FULL ADDRESS OF :- M/s Vasudev Shamji Savaria Bajirao,
MANUFACTURER Mehrapara Raigarh (C.G.) 496001
Ph.- 07762-220050 Mo.- 099267-42045
Email- ravi.savaria@rediffmail.com
(C) Category :- General
11. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 106/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 107/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 108/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 109/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 110/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
9. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 111/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 112/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 113/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 114/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/VSS/6475 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 115/336
Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Dinesh Industries,
Telibandha, Near Gali No.- 6 Ravigram,
Ph.- 0771-3265888
Mo.- 9755042331, 9926156001
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 116/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 117/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Dinesh Industries,
THE FIRM Telibandha, Near Gali No.- 6 Ravigram,
Ph.- 0771-3265888
Mo.- 9755042331, 9926156001
12. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 118/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 119/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.)
OR
Manager (Operation) Indian Register of Shipping Senior MIG-
2, Secter A, 1st Floor, in front of Bank of India Indrapuri
Bhopal. (M.P.)
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.)
OR
Manager (Operation) Indian Register of Shipping Senior MIG-
2, Secter A, 1st Floor, in front of Bank of India Indrapuri
Bhopal. (M.P.)
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi)
General Manager
No. 120/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 121/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 122/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
10. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 123/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 124/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 125/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 126/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DI/6476 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 127/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Quality Cement Pipes,
Add : 11,12 Industrial Estate
Bhanpuri Raipur (C.G.) 493221
Ph.- 0771-4024190 Mo.- 9752005557
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 128/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 129/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Quality Cement Pipes,
THE FIRM Add : 11,12 Industrial Estate
Bhanpuri Raipur (C.G.) 493221
Ph.-0771-4024190 Mo.- 9752005557
13. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 130/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 131/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.)
OR
Manager (Operation) Indian Register of Shipping Senior MIG-
2, Secter A, 1st Floor, in front of Bank of India Indrapuri
Bhopal. (M.P.)
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi)
General Manager
No. 132/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 133/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 134/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
11. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 135/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 136/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 137/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 138/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/QCP/6477 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 139/336
eS Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Raj Pipes,
Infront of Industrial Estate,
G.E. Road, Rajnandgaon (C.G.)
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 140/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 141/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Raj Pipes,
THE FIRM Infront of Industrial Estate,
G.E. Road, Rajnandgaon (C.G.)
14. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 142/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 143/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 144/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 145/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 146/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
12. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 147/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 148/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 149/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 150/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/RP/6478 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 151/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Akash Pipe Industries,
Dharampara Mungeli Bilaspur (C.G.) 495334
Mo.- 9993070099
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 15 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 152/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 153/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Akash Pipe Industries,
THE FIRM Dharampara Mungeli Bilaspur (C.G.) 495334
Mo.- 9993070099
15. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 154/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
20 RCCHPF80001022 80 32.49
21 RCCHPF80001023 100 35.81
22 RCCHPF80001024 150 42.11
23 RCCHPF80001025 200 51.98
24 RCCHPF80001026 225 61.22
25 RCCHPF80001027 250 63.53
26 RCCHPF80001028 300 76.23
27 RCCHPF80001029 350 88.94
28 RCCHPF80001030 400 128.21
29 RCCHPF80001031 450 140.33
30 RCCHPF80001032 500 187.50
31 RCCHPF80001033 600 217.14
32 RCCHPF80001034 700 226.38
33 RCCHPF80001035 800 243.71
34 RCCHPF80001036 900 360.94
35 RCCHPF80001037 1000 378.99
36 RCCHPF80001038 1100 577.50
37 RCCHPF80001039 1200 706.86
38 RCCHPF80001040 1400 974.14
39 RCCHPF80001041 1600 1099.56
40 RCCHPF80001042 1800 1398.71
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends
of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-
date amendment Nominal Diameter of Pipes in mm.
41 RCCHPF80001043 80 106.59
42 RCCHPF80001044 100 130.98
43 RCCHPF80001045 150 183.37
44 RCCHPF80001046 200 264.45
45 RCCHPF80001047 225 275.68
46 RCCHPF80001048 250 309.35
47 RCCHPF80001049 300 309.35
48 RCCHPF80001050 350 415.80
49 RCCHPF80001051 400 462.00
50 RCCHPF80001052 450 1050.00
51 RCCHPF80001053 500 1155.00
52 RCCHPF80001054 600 1480.50
53 RCCHPF80001055 700 1680.00
54 RCCHPF80001056 800 2250.00
55 RCCHPF80001057 900 2936.38
56 RCCHPF80001058 1000 3052.39
57 RCCHPF80001059 1100 3465.00
58 RCCHPF80001060 1200 4378.50
59 RCCHPF80001061 1400 5911.43
60 RCCHPF80001062 1600 7045.31
61 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of
the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment Nominal Diameter of Pipes in mm.
(Suresh Keshi)
General Manager
No. 155/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
62 RCCHPF80001085 80 128.48
63 RCCHPF80001086 100 149.69
64 RCCHPF80001087 150 202.08
65 RCCHPF80001088 200 302.61
66 RCCHPF80001089 225 324.32
67 RCCHPF80001090 250 374.22
68 RCCHPF80001091 300 415.80
69 RCCHPF80001092 350 462.00
70 RCCHPF80001093 400 485.10
71 RCCHPF80001094 450 1037.84
72 RCCHPF80001095 500 1239.91
73 RCCHPF80001096 600 1386.00
74 RCCHPF80001097 700 1732.50
75 RCCHPF80001098 800 1963.50
76 RCCHPF80001099 900 2772.00
77 RCCHPF80001100 1000 3291.75
78 RCCHPF80001101 1100 3407.25
79 RCCHPF80001102 1200 4389.00
80 RCCHPF80001103 1400 5313.00
81 RCCHPF80001104 1600 7507.50
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure
Pipes, Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Reinforced Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per
below:
82 RCCHPF80001127 80 31.50
83 RCCHPF80001128 100 35.81
84 RCCHPF80001129 150 42.11
85 RCCHPF80001130 200 51.98
86 RCCHPF80001131 225 61.22
87 RCCHPF80001132 250 63.53
88 RCCHPF80001133 300 76.23
89 RCCHPF80001134 350 88.94
90 RCCHPF80001135 400 128.21
91 RCCHPF80001136 450 140.33
92 RCCHPF80001137 500 187.50
93 RCCHPF80001138 600 210.00
94 RCCHPF80001139 700 226.38
95 RCCHPF80001140 800 243.71
96 RCCHPF80001141 900 315.00
97 RCCHPF80001142 1000 378.99
98 RCCHPF80001143 1100 525.00
99 RCCHPF80001144 1200 577.50
100 RCCHPF80001145 1400 735.00
101 RCCHPF80001146 1600 840.00
102 RCCHPF80001147 1800 1050.00
(Suresh Keshi)
General Manager
No. 156/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
103 RCCHPF80001148 Upto 50 Km. 19.64
104 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
105 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
106 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
107 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 157/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 158/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 159/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 160/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
13. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 161/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 162/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 163/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 164/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/API/6479 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 165/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Korba Cement Products,
Urga-Korba (C.G.)
Mo.- 9425224499
Email- korbacementproducts@yahoo.in
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 166/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 167/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Korba Cement Products,
THE FIRM Urga-Korba (C.G.)
Mo.- 9425224499
Email- korbacementproducts@yahoo.in
16. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 168/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 169/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 170/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 171/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 172/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 173/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
14. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 174/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 175/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 176/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 177/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/KCP/6480 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 178/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Dhansree Concrete Products ,
Manendragarh Road Ambikapur (C.G.) 497001
Mo.- 9425580211
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 179/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 180/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Dhansree Concrete Products ,
THE FIRM Manendragarh Road Ambikapur (C.G.) 497001
Mo.- 9425580211
17. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 181/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 182/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.)
OR
Manager (Operation) Indian Register of Shipping Senior MIG-
2, Secter A, 1st Floor, in front of Bank of India Indrapuri
Bhopal. (M.P.)
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
18 QUALITY ASSURANCE : Dy. Director (Q &A), DGS&D, Bhilai (C.G.)
OR
Manager (Operation) Indian Register of Shipping Senior MIG-
2, Secter A, 1st Floor, in front of Bank of India Indrapuri
Bhopal. (M.P.)
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi)
General Manager
No. 183/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 184/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 185/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
15. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 186/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 187/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 188/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 189/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/DCP/6481 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 190/336
rS Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Shivshakti Industries,
Kena Bandh Bouripara,
Ambikapur, Distt Surguja (C.G.) 497001
Mo.-9425582023-24
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 31-03-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 191/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
Copy to,
(Suresh Keshi)
General Manager
No. 192/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Shivshakti Industries,
THE FIRM Kena Bandh Bouripara,
Ambikapur, Distt Surguja (C.G.) 497001
Mo.-9425582023-24
18. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 193/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
(Suresh Keshi)
General Manager
No. 194/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
(Suresh Keshi)
General Manager
No. 195/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
22. Special Note : 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 196/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 197/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
16. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 198/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 199/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 200/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 201/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/14-15/RCCHP/SI/6482 Dated: 31-03-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 202/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Jai Mahamaya Cement Pipe Industries,
Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358
Email- alokjaiswal.pcc@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 203/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 204/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Jai Mahamaya Cement Pipe Industries,
THE FIRM Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358
Email- alokjaiswal.pcc@gmail.com
(b) NAME AND FULL ADDRESS OF :- M/s Jai Mahamaya Cement Pipe Industries,
MANUFACTURER Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358
Email- alokjaiswal.pcc@gmail.com
19. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 205/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends
of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-
date amendment Nominal Diameter of Pipes in mm.
15 RCCHPF80001045 150 183.37
16 RCCHPF80001046 200 264.45
17 RCCHPF80001047 225 275.68
18 RCCHPF80001048 250 309.35
19 RCCHPF80001049 300 309.35
20 RCCHPF80001050 350 415.80
21 RCCHPF80001051 400 462.00
22 RCCHPF80001052 450 1050.00
23 RCCHPF80001053 500 1155.00
24 RCCHPF80001054 600 1480.50
25 RCCHPF80001055 700 1680.00
26 RCCHPF80001056 800 2250.00
27 RCCHPF80001057 900 2936.38
28 RCCHPF80001058 1000 3052.39
29 RCCHPF80001059 1100 3465.00
30 RCCHPF80001060 1200 4378.50
31 RCCHPF80001061 1400 5911.43
32 RCCHPF80001062 1600 7045.31
33 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of
the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment Nominal Diameter of Pipes in mm.
34 RCCHPF80001091 300 415.80
35 RCCHPF80001092 350 462.00
36 RCCHPF80001094 450 1037.84
37 RCCHPF80001096 600 1386.00
38 RCCHPF80001099 900 2772.00
39 RCCHPF80001100 1000 3291.75
40 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
41 RCCHPF80001148 Upto 50 Km. 19.64
42 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
43 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
44 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
45 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 206/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Address:-
M/s Jai Mahamaya Cement Pipe Industries,
Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358
Email- alokjaiswal.pcc@gmail.com
7. DELIVERY PERIOD : 30 Days
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 207/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
(Suresh Keshi)
General Manager
No. 208/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 209/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 210/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
17. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 211/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 212/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 213/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 214/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JMCPI/6483 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 215/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Jai Ambe Cement Product,
Vill-Sargawan, Teh.-Ambikapur
Distt.- Surguja (C.G.) 497001
Mo.- 9826122358, 9425254259
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 216/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 217/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Jai Ambe Cement Product,
THE FIRM Vill-Sargawan, Teh.-Ambikapur
Distt.- Surguja (C.G.) 497001
Mo.- 9826122358, 9425254259
(b) NAME AND FULL ADDRESS OF :- M/s Jai Ambe Cement Product,
MANUFACTURER Vill-Sargawan, Teh.-Ambikapur
Distt.- Surguja (C.G.) 497001
Mo.- 9826122358, 9425254259
20. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 218/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
(Suresh Keshi)
General Manager
No. 219/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 220/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
(Suresh Keshi)
General Manager
No. 221/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 222/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 223/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
18. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 224/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 225/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 226/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 227/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JACP/6484 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 228/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Jaiswal Cement Products,
Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358 / 9425254259
Email- alokjaiswal.pcc@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 229/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 230/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Jaiswal Cement Products,
THE FIRM Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358 / 9425254259
Email- alokjaiswal.pcc@gmail.com
21. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 231/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Schedule -3: Reinforced Concrete, Medium duty, Non-Pressure Pipes, Class: NP3, with ends
of the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-
date amendment Nominal Diameter of Pipes in mm.
15 RCCHPF80001045 150 183.37
16 RCCHPF80001046 200 264.45
17 RCCHPF80001047 225 275.68
18 RCCHPF80001048 250 309.35
19 RCCHPF80001049 300 309.35
20 RCCHPF80001050 350 415.80
21 RCCHPF80001051 400 462.00
22 RCCHPF80001052 450 1050.00
23 RCCHPF80001053 500 1155.00
24 RCCHPF80001054 600 1480.50
25 RCCHPF80001055 700 1680.00
26 RCCHPF80001056 800 2250.00
27 RCCHPF80001057 900 2936.38
28 RCCHPF80001058 1000 3052.39
29 RCCHPF80001059 1100 3465.00
30 RCCHPF80001060 1200 4378.50
31 RCCHPF80001061 1400 5911.43
32 RCCHPF80001062 1600 7045.31
33 RCCHPF80001063 1800 7793.75
Schedule -5: Reinforced Concrete, Heavy duty, Non-Pressure Pipes, Class: NP4, with ends of
the Pipes Suitable for flush joints conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment Nominal Diameter of Pipes in mm.
34 RCCHPF80001091 300 415.80
35 RCCHPF80001092 350 462.00
36 RCCHPF80001094 450 1037.84
37 RCCHPF80001096 600 1386.00
38 RCCHPF80001099 900 2772.00
39 RCCHPF80001100 1000 3291.75
40 RCCHPF80001102 1200 4389.00
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
41 RCCHPF80001148 Upto 50 Km. 19.64
42 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
43 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
44 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
45 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 232/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Address:-
M/s Jaiswal Cement Products,
Mission Chowk, Ring Road,
Ambikapur Distt.- Surguja (C.G.) 497001
Mo.- 9826122358 / 9425254259
Email- alokjaiswal.pcc@gmail.com
7. DELIVERY PERIOD : 30 Days
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 233/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
(Suresh Keshi)
General Manager
No. 234/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 235/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 236/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
19. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 237/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 238/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 239/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 240/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/JCP/6485 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 241/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Bhilai Cement Pipe Manufacturing Co.,
70-A, Industrial Estate,
Nandini Road, Bhilai (C.G.)
Ph.- 0788 - 2286518
Mo.- 9893115028, 9981125028
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 242/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 243/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bhilai Cement Pipe Manufacturing co.,
THE FIRM 70-A,Industrial Estate,
Nandini Road, Bhilai (C.G.)
Ph.- 0788-4050236, 2286518
Mo.- 9893115028, 9981125028
(b) NAME AND FULL ADDRESS OF :- M/s Bhilai Cement Pipe Manufacturing co.,
MANUFACTURER 70-A,Industrial Estate,
Nandini Road, Bhilai (C.G.)
Ph.- 0788-4050236, 2286518
Mo.- 9893115028, 9981125028
22. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 244/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
(Suresh Keshi)
General Manager
No. 245/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
(Suresh Keshi)
General Manager
No. 246/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 247/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 248/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
20. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 249/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 250/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 251/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 252/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPMC/6486 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 253/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Bhawani Cement Pipe Industries,
D-1, Om Complex, Fafadih Raipur (C.G.) 492001
Ph.- 07714092724 , Mo.- 9425507207
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 254/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 255/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bhawani Cement Pipe Industries,
THE FIRM D-1, Om Complex, Fafadih Raipur (C.G.) 492001
Ph.- 07714092724 , Mo.- 9425507207
(b) NAME AND FULL ADDRESS OF :- M/s Bhawani Cement Pipe Industries,
MANUFACTURER Kh.No-521/9 (Part) & 522-4 (Part)
Village Deori Bilaspur Road Raipur (C.G.) 492001
Ph.- 07714092724 , Mo.- 9425507207
(C) Category :- General
23. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 256/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
Schedule -7: Reinforced Concrete Collar for Reinforced Concrete Light duty, Non-Pressure Pipes,
Class: NP2, conforming to IS: 458/2003 (Fourth Revision) with up-to-date amendment. Reinforced
Concrete Collar for the Pipes. Class: NP2, Size (Nominal Diameter in mm.) is as per below:
21 RCCHPF80001130 200 51.98
22 RCCHPF80001131 225 61.22
23 RCCHPF80001132 250 63.53
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
24 RCCHPF80001148 Upto 50 Km. 19.64
25 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
26 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
27 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
28 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 257/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 258/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note : 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 259/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 260/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
21. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 261/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 262/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 263/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 264/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCPI/6487 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 265/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Bastar Cement Products,
Geedam Road, P.O Pandripani,
Jagdalpur (Bastar) 494001
Mo.- 9826612012, 9425212012
Email- gggrewaljitender@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 266/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 267/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Bastar Cement Products,
THE FIRM Geedam Road, P.O Pandripani,
Jagdalpur (Bastar) 494001
Mo.- 9826612012, 9425212012
Email- gggrewaljitender@gmail.com
24. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 268/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
18 RCCHPF80001148 Upto 50 Km. 19.64
19 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
20 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
21 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
22 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 269/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
17 INSPECTION AUTHORITY : Dy. Director (Q &A), DGS&D, Bhilai (C.G.)
OR
Manager (Operation) Indian Register of Shipping Senior MIG-
2, Secter A, 1st Floor, in front of Bank of India Indrapuri
Bhopal. (M.P.)
OR
Chief Engineer, Project & Development India Ltd. 4st floor,
4/2 Karaya Road, 67 Shekespeare Sarani Kolkata (W.B.)
OR
General Manager (Inspection) RITES Ltd. Churchgate
Station Road, Second Floor, M.K.Road, Mumbai-400020
(Mah)
OR
Manager (Operations) SGS India Pvt. Ltd. 43, RR Arcade,
Zone-2, MP Nagar, Bhopal-462011. (M.P.)
OR
CSIDC (DEPARTMENTAL TECHNICAL WING)
(Suresh Keshi)
General Manager
No. 270/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 271/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 272/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
22. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 273/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 274/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 275/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 276/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/BCP/6488 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 277/336
0S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Engineers Enterprises,
Rawabhata Industrial Area
P.O. Birgaon Raipur (C.G.) 493221
Mo.- 9826612012, 9425212012
Email- grewaljitender@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 278/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 279/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Engineers Enterprises,
THE FIRM Rawabhata Industrial Area
P.O. Birgaon Raipur (C.G.) 493221
Mo.- 9826612012, 9425212012
Email- grewaljitender@gmail.com
25. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 280/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 281/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
(Suresh Keshi)
General Manager
No. 282/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 283/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 284/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
23. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 285/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 286/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 287/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 288/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/EE/6489 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 289/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Grewal Cement Pipe Industries,
31 Industrial Area, P.O. Birgaon 493221
Raipur (C.G.) Mo.- 9826612012 , 9425212012
Email- grewaljitender@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 10-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 13 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 290/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 291/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Grewal Cement Pipe Industries,
THE FIRM 31 Industrial Area, P.O. Birgaon 493221
Raipur (C.G.) Mo.- 9826612012 , 9425212012
Email- grewaljitender@gmail.com
(b) NAME AND FULL ADDRESS OF :- M/s Grewal Cement Pipe Industries,
MANUFACTURER 31 Industrial Area, P.O. Birgaon 493221
Raipur (C.G.) Mo.- 9826612012 , 9425212012
Email- grewaljitender@gmail.com
26. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 292/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
Schedule - 7 Transportation Charges : Sub Item Code No. Item Description Distance in Km.
Transportation Charges in % on the Total Cost of Pipes/Collars.
E.D. VAT/CST Extra
18 RCCHPF80001148 Upto 50 Km. 19.64
19 RCCHPF80001149 Above 50 Km. Upto 100 Km. 21.00
20 RCCHPF80001150 Above 100 Km. Upto 150 Km. 28.88
21 RCCHPF80001151 Above 150 Km. Upto 200 Km. 32.00
22 RCCHPF80001152 Above 200 Km. 37.00
(Suresh Keshi)
General Manager
No. 293/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 294/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 295/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 296/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
24. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 297/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 298/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 299/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 300/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/GCPI/6490 Dated: 10-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 301/336
Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s R.C.C. Hume Pipe & Products ,
S.U.I.E. Frazerpur Nayamundapara ,
Industrial Estate , Jagdalpur Bastar (C.G.)
Ph.- 07782227204 Mo.-9425260321, 9406286611
Email- vijaykumaragarwal.47@gmail.com
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 30-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 302/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 303/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s R.C.C. Hume Pipe & Products ,
THE FIRM S.U.I.E. Frazerpur Nayamundapara ,
Industrial Estate , Jagdalpur Bastar (C.G.)
Ph.- 07782227204 Mo.-9425260321, 9406286611
Email- vijaykumaragarwal.47@gmail.com
(b) NAME AND FULL ADDRESS OF :- M/s R.C.C. Hume Pipe & Products ,
MANUFACTURER S.U.I.E. Frazerpur Nayamundapara ,
Industrial Estate , Jagdalpur Bastar (C.G.)
Ph.- 07782227204 Mo.-9425260321, 9406286611
Email- vijaykumaragarwal.47@gmail.com
27. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 304/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 305/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
(Suresh Keshi)
General Manager
No. 306/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 307/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 308/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
25. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 309/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 310/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 311/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 312/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/RCCHP&P/6491 Dated: 30-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 313/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Chhattisgarh Pipe Industries,
Village - Bhoinabhata
Tah. & Distt. Bemetara (C.G.)
Mo.- 9993730777
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 30-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 314/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 315/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Chhattisgarh Pipe Industries,
THE FIRM Village - Bhoinabhata
Tah. & Distt. Bemetara (C.G.)
Mo.- 9993730777
28. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 316/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 317/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
(Suresh Keshi)
General Manager
No. 318/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 319/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 320/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
26. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 321/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 322/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 323/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 324/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/CPI/6492 Dated: 30-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager
No. 325/336
S Chhattisgarh State Industrial Development Corporation Limited
(A Government of Chhattisgarh Undertaking)
First Floor, Udyog Bhawan, Ring Road No.-1, Telibandha , Raipur 492006 (C.G.)
EPABX No.- 0771-6002071-73, Fax: 0771-4057624 (Mkt)
CIN-U45203CT1981SG001853 PAN-AABCM6288N Service Tax Regn No.-AABCM6288NSD004
Website: www.csidc.in, Email : csidc.cg@nic.in, csidc_raipur@yahoo.com
To,
M/s Star Industries,
Mukhtiyarpara Nagpur
Manendragarh Korea (C.G.)
Mo.- 09424260460, 09993251066
Sub :- Rate Contract for the supply of Item - RCC HUME PIPE (Valid From dated 30-04-2015 to 01-04-2016)
Dear Sir,
You are hereby informed that your above referred tender read with subsequent letters mentioned
above for the Stores specified in the Schedules annexed has been accepted. This Rate Contract will be
governed by the terms and conditions brought in CSIDC Form No.1 & 2. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate Contract / Transaction.
You are required to show the original INK-SIGNED subject Rate Contract to the satisfaction of
Direct Demanding Officer who will place the supply order as per instructions contained in CSIDC form
No. 2 and also to the Quality Assurance Officer for inspection purpose and to the Paying Authority at the
time of getting the payment.
SCHEDULES ANNEXED:
1. Schedule A Description of Stores, Prices, Duties/Taxes .
2. Annexure -A Technical Particulars of Item- RCC HUME PIPE
3. Schedule B Special conditions of contract (if any).
4. Schedule C Information to DDOs about parallel rate contracts.
5. Schedule D Format for Drawal Report.
Encl. 14 pages
Yours faithfully,
(Suresh Keshi)
General Manager
For and on behalf of the purchaser
Named in CSIDC Form No.2
No. 326/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
Copy to,
(Suresh Keshi)
General Manager
No. 327/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
SCHEDULE A
Description of Stores, Prices, Duties/Taxes
For the supply of Item- RCC HUME PIPE as per AnnexureA enclosed.
1. (a) NAME AND FULL ADDRESS OF :- M/s Star Industries,
THE FIRM Mukhtiyarpara Nagpur
Manendragarh Korea (C.G.)
Mo.- 09424260460, 09993251066
29. DESCRIPTION OF ITEM- RCC HUME PIPE SPECIFICATION, UNIT RATE AS BELOW
(Suresh Keshi)
General Manager
No. 328/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
(Suresh Keshi)
General Manager
No. 329/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
16. PAYMENT TERMS : The payment of full 100% of prices of the stores of each
consignment there-of will be made after receipt and acceptance of
the stores by the consignee/interim consignee in full and good
condition within 20 days as per SPR rule No.11, if the bills are in
order. In case of delay in payment without any reason the
department will be liable to pay interest as per prevailing bank rate.
Bills are to be submitted in the prescribed form of the paying
authority of purchaser / indenter and are to be supported with
inspection note issued by the inspector and consignees Receipt
Certificate .
(Suresh Keshi)
General Manager
No. 330/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
21. SECURITY DEPOSIT : As per General conditions of contract , CSIDC Form No. 1, Clause
7, the Purchaser / DDOs may require the contractor to furnish a
security deposit which shall be made after issue of the acceptance
of the supply order within the period specified by the purchaser /
DDOs. Such security deposit shall not ordinarily exceed 3% .
The security shall be in form of Demand Drafts issued by any
of the Scheduled Commercial Banks. No other form of security
is to be accepted. The security deposit amount is to be refunded
after successful completion of the supply.
22. Special Note 1. Purchasing Departments / end user will ensure to sending
the copy of every order to this office for Approval of
inspection Agency against inspection of stores.
2. Purchasing Departments / end user will ensure to Pre
Dispatch inspection of stores Through inspection agency
in enlisted in the CSIDC Panel.
3. Purchasing Departments / end user will be responsible for
insuring the Quality of accepted stores.
4. Purchasing Departments / end user shall be insure to
obtained the central excise invoices of Manufacturer as
mentioned in the Schedule-A vide sr. no. 1-B if excise
duty Applicable to the Rate Contract Holder.
5. Purchasing Departments / end user shall be insure to
execute the Integrity Pact between BUYER and
BIDDER/SUPPLIEY in accordance with the letter vide no.
799/eq-l-/2013 New Raipur Dated 10-07-2013 and 243/ fo-
@fu-@pkj@2013 New Raipur Dated 06-07-2013 issued
by the Chief Secretary Govt. Of Chhattisgarh.
(Suresh Keshi)
General Manager
No. 331/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
Annexure 'A'
CSIDC/MKD/TECH/2014-15/14
This Specification covers the requirements for Non-Pressure Reinforced Precast Concrete Pipes
(Spun) used for culverts, sewers, irrigation etc.
The Concrete Pipes shall be conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment with regards to Design /Dimensions / Tolerances / Workmanship & Finish /
Materials used for making the Pipes. The Pipes shall be manufactured by spinning process. The
ends of the concrete pipes shall be suitable for flush joints or collar joints or suitable for Socket
& Spigot, roll on joints or confined gasket joints as per the requirements of the purchaser.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision), with up-to-date amendment.
2. Tenderers may also quote rates separately for the Collars. Dimensions and Design
requirements of Reinforced Concrete Collars for Pipes of Class NP2 shall be as per the Table
21 of IS: 458/2003, with up-to-date amendment.
Schedule- 2: Reinforced Concrete, Light duty, Non-pressure Pipes, Class: NP2, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP2
shall be as per the Table 2 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP2 Class Pipes shall be as per Table 13 of
IS: 458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 332/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
Schedule- 3: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Schedule- 4: Reinforced Concrete, Medium duty, Non-pressure Pipes, Class: NP3, with ends
of the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP3
shall be as per the Table 3 of IS: 458/2003(Fourth Revision) with up-to-date amendment
2. Spigot & Socket dimensions of NP3 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with up-to-
date amendment.
Schedule- 5: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for flush joints conforming to IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000,
1100, 1200, 1400, 1600 & 1800.
27. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
Schedule- 6: Reinforced Concrete, Heavy duty, Non-pressure Pipes, Class: NP4, with ends of
the pipes suitable for Socket & Spigot, roll on joints or confined gasket joints
conforming to IS:458/2003 (Fourth Revision) with up-to-date amendment along
with Rubber Ring conforming to Type 2 of IS: 5382/1985 with up-to-date
amendment.
(K.N.K. Mishra)
Incharge PS-VII
No. 333/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions, Design and Strength requirements of Reinforced Concrete Pipes of Class NP4
shall be as per the Table 6 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
2. Spigot & Socket dimensions of NP4 Class Pipes shall be as per Table 14 & Table 17 of IS:
458/2003(Fourth Revision) with up-to-date amendment.
3. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
Schedule-7: Reinforced Concrete Collar for Reinforced Concrete, Light duty, Non-pressure
Pipes, Class: NP2 conforming to IS: 458/2003 (Fourth Revision) with up-to-date
amendment.
Reinforced Concrete Collar for the Pipes, Class: NP2, size (Nominal Diameter
in mm) , is as per below:
80, 100, 150. 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900,
1000,1100,1200, 1400, 1600 & 1800.
1. Dimensions and Design requirements of Reinforced Concrete Collar for Pipes of Class NP2
shall be as per the Table 21 of IS: 458/2003(Fourth Revision) with up-to-date amendment.
Review of Reports:
The following Reports shall be submitted to the Inspecting Officer at the time of Inspection for review:
During manufacture, Compressive Strength Tests shall be conducted by the manufacturers on 150 mm
Concrete Cubes in accordance with the relevant requirements of IS: 456/2000 with up-to-date amendment
and IS: 516/1959 (Reaffirmed 1999) with up-to-date amendment , as stipulated in clause 5.5.3 of IS:
458/2003 (Fourth Revision) with up-to-date amendment. The manufacturer shall submit the results of
Compressive Strength Tests of Concrete Cubes made from the Concrete used for the pipes. Alternatively,
if the manufacturers do not have the facilities for Compressive Strength Test on Concrete Cubes, they
shall get the Test done at CSIDC laboratory at least once in a month and submit the report to the
Inspecting Officer for review.
(K.N.K. Mishra)
Incharge PS-VII
No. 334/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
1. Manufacturer shall submit his own Certificate for materials of construction used in the pipes.
2. Manufacturer shall submit Test Certificate for the Steel used for Reinforcement.
3. Manufactures Test Repot of Rubber Rings shall be submitted for review (incase of Pipes
with Socket & Spigot ends).
TESTS:
As per prevailing practice, the following Tests / Checking shall be carried out.
1. Visual examination,
2. Permeability Test and
3. Three Edge Bearing Test to produce 0.25 mm crack.
4. Any other Tests that are mentioned in IS: 458/2003 (Fourth Revision) with up-to-date
amendment shall be carried out if desired by the Consignee.
NOTE:
1. The tolerances on Pipes shall be as per clause 8.2 & tolerances on Collar shall be as per
Table No.21 of IS: 458/2003 (Fourth Revision) with up-to-date amendment.
2. Workmanship & Finish of the Pipes & Collars shall be as per Clause 9 of IS:
458/2003 (Fourth Revision) with up-to-date amendment.
3. The length in which the pipes are to be supplied shall be as per the mutual agreement between
the purchaser and the supplier. However, the recommended length above 300 mm Nominal
Diameter is 2.5 meters.
4. Curing of the pipes shall be done as per the Clause 7.4 of IS: 458/2003 (Fourth Revision)
with up-to-date amendment.
5. Rubber Ring chords used in the Pipe joints shall conform to Type 2 of IS: 5382/1985 with
up-to-date amendment.
6. The following information shall be shall be clearly marked on the each Finished Pipe.
a. Size of Pipe,
b. Class of Pipe, and
c. Name of manufacture.
7. The supplier shall guarantee the Pipes and Collars for a period of 12 months from the date of
receipt of the materials by the consignee.
8. For Reinforced Concrete Pipes Rates must be quoted on the basis of Per Meter length and in
the case of Collars Rates shall be quoted on the basis of Per Piece. (The cost of the
Rubber Ring shall be included in the Rate per Meter length of the Pipe. No extra payment
towards the supply of Rubber rings will be made) as per the prevailing practice,
transportation cost for Pipes & Collars shall be quoted separately.
(K.N.K. Mishra)
Incharge PS-VII
No. 335/336
SCHEDULE B
(SPECIAL CONDITION OF CONTRACT)
RCC HUME PIPE
This Rate Contract Will be governed by the terms & conditions laid down in
The CSIDC form No. 1 & 2
(Suresh Keshi)
General Manager
No. 336/336
Rate Contract No. CSIDC/MKD/PS-VII/102/510/15-16/RCCHP/SI/6493 Dated: 30-04-2015
SCHEDULE D
Total Position of Order against Rate Contract till the submission of Report.
Foot 1. Value indicate should be a) Value of orders received during the quarter-Rs.
Total value inclusive of all
Taxes duties and incidental b) Value of orders supplied during the quarter-Rs.
Charges
(Suresh Keshi)
General Manager