Vous êtes sur la page 1sur 11

Flexi Outdoor Case

Quick Installation Guide

Issue: 4 Issue date: March 2013

A25000-A900-A32-03-76P1

C55160.01--00

Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of
its products and services. We would like to encourage you as our customers and users to join
us in working towards a cleaner, safer environment. Please recycle product packaging and
follow the recommendations for power use and proper disposal of our products and their
components.
If you should have questions regarding our Environmental Policy or any of the environmental
services we offer, please contact us at Nokia Siemens Networks for any additional information.
Quick Installation Guide

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-
TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT
LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR
THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2012. All rights reserved.

f Important Notice on Product Safety


This product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the Legal, Safety
and Environmental Information part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur Produktsicherheit


Von diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-
anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal,
Safety and Environmental Information dieses Dokuments oder dieses Dokumentations-
satzes.

2 A25000-A900-A32-03-76P1
Issue: 4 Issue date: March 2013
Quick Installation Guide

Table of Contents
This document has 11 pages.

1 Flexi Outdoor Case Quick Installation Guide . . . . . . . . . . . . . . . . . . . . . . 5


1.1 Generic Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Installing on the floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3 Installing on the pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 Installing on the wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.5 General rules for IDU cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.6 Final Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

A25000-A900-A32-03-76P1 3
Issue: 4 Issue date: March 2013
Quick Installation Guide

4 A25000-A900-A32-03-76P1
Issue: 4 Issue date: March 2013
Quick Installation Guide Flexi Outdoor Case Quick Installation Guide

1 Flexi Outdoor Case Quick Installation Guide

1.1 Generic Information

Dimension of Flexi Outdoor Case Standard tools


8 mm Allen key
509 mm

522.5 mm TX 10 screwdriver for M3 screw


TX 25 screwdriver for M5 screw
148 mm 7 mm spanner and 13 mm spanner

60 mm
Adjustable wrench (56 to 64 mm)
Fish tape and Thread locking compound
(medium strength non-permanent)

g This product may need to be installed on a high-rise structure such as a mast or


roof. When installing the product, wear a safety harness and other relevant protec-
tive gear. In addition, follow all occupational health and safety regulations applica-
ble to the installation.

Minimum clearances

:DOOPHDVXUHPHQWV

PLQPP
7RSPLQPP PHDVXUHGIURP
For maintenance space
EDFNFRYHU %HWZHHQ)2&V from the back 145mm

QHHGHGIRUIUHVK PLQPP
DLU

PLQPP
PHDVXUHG
IURPSOLQWK
min 600mm

min 400mm

7RVLGHPLQPP
)URQWPLQPP
3OLQWK

Preparation of installation
1.The cable output must be placed
depending on the installation needs. This
evaluation must be made before starting
the installation procedure.
2. Besides the type of the IDU, its place-
ment into the FOC should be considered.
The installation technician is charged to
choose how the IDU must be installed.

A25000-A900-A32-03-76P1 5
Issue: 4 Issue date: March 2013
Flexi Outdoor Case Quick Installation Guide Quick Installation Guide

Install the adapter mechanics Install Flexi Outdoor Case to the plinth

Thread locking compound


a Thread locking compound (medium strength non-permanent)
(medium strength, non-permanent)

Bottom c
a1

b Thread locking compound


(medium strength,
non-permanent)

The installation of the two squares Fix the outdoor case to the plinth with two
depends on the right/left positioning of the torx M5x8 screws and thread locking com-
front side with respect to the pole/wall. pound.

1.2 Installing on the floor

Install the Plinth and the FOC case


1. Check the clearances around the plinth.
Facility wall
Fan maintenance 2. Place the plinth on the floor, grounding
space from the back
Plint h 145 mm (5.7 in.) points facing forward.
3. Bolt on the floor with two bolts.
min
250 mm
(9.8 in.) 4. Fix the outdoor case on the plinth.
13.5 (4 pcs)

g Do not connect the cables before


having carried out the fixing of the
case on the plinth.

The two-outputs configuration Stacking of more FOCs

6 A25000-A900-A32-03-76P1
Issue: 4 Issue date: March 2013
Quick Installation Guide Flexi Outdoor Case Quick Installation Guide

The two-outputs configuration Stacking of more FOCs


In the floor installation, the two-outputs More FOCs can be stacked and this
configuration can be used. option is only possible for the floor instal-
lation. And maximum 5 FOCs can be
stacked for zone 4 and maximum 11
FOCs for zone 2 (earthquake measures).

1.3 Installing on the pole

Safety washers position Hole Numbering Fix the mounting screws

g Note that the blue safety washers hold the screws in place during installation. They
should be installed to the screws after the screws are through the bracket.

Fix the lower bracket Lift the plinth and Fix the lower bracket
Tighten the screws

g Before mounting the outdoor case on the pole, install the IDU. The IDU can be
installed after having placed FOC on the pole. Do not connect the cables before
having carried out the lifting of the IDU on the pole.

A25000-A900-A32-03-76P1 7
Issue: 4 Issue date: March 2013
Flexi Outdoor Case Quick Installation Guide Quick Installation Guide

Tighten the screws Back-to-back Installation

g A second unit can be installed back to back using the same brackets. And
maximum 2 units can be stacked on the pole.

1.4 Installing on the wall

Prepare the wall installation Lift the plinth and Tighten the screws

g Do not connect the cables before


having carried out the lifting of the IDU
on the wall.

8 A25000-A900-A32-03-76P1
Issue: 4 Issue date: March 2013
Quick Installation Guide Flexi Outdoor Case Quick Installation Guide

Fix the lower adapter mechanics and Two cases on the wall
Tighten the screws

For maintenance space


from the back 145mm

min 600mm

min 400mm

g Before mounting the outdoor case on


the wall, install the IDU. The IDU can
be installed after having placed FOC
on the wall.

1.5 General rules for IDU cabling

g Connect the grounding cable to the IDU before inserting the IDU into the case. Make
sure that the fans power supply cables can be easily reached for their successive con-
nection to fan controller board.

Insert the cables

Bend and Hose for Floor Installation Hose for Pole/Wall Installation

A25000-A900-A32-03-76P1 9
Issue: 4 Issue date: March 2013
Flexi Outdoor Case Quick Installation Guide Quick Installation Guide

Detail for front cover, and hose entry Example for the FlexiHybrid

Install the hose in the front cover before fixing the front cover to the box.

Power and Alarm cable options

Another power cable T55248.30


OR T55248.31 for 2nd IDU installed
/power redundancy

Power cable T55248.30 from FlexiBTS/FPMA


OR
T55248.31 from general power source

1.6 Final Operation

Final taping Connection of the GND cables and


Install the covers
a

10 A25000-A900-A32-03-76P1
Issue: 4 Issue date: March 2013
Quick Installation Guide Flexi Outdoor Case Quick Installation Guide

Final taping Connection of the GND cables and


Install the covers
Connect the cable to IDU/FOC, taping the FOC is equipped with two grounding
cables at the end of the hose and fix the cables. Connect always both the cables to
cable by ties. After that, close the FOC. the grounding point inside the cover. The
unused cable can be used in a future
expansion.
(a) IDU grounding cable
(b) external FOC grounding cable

Installation of the cable output block

A25000-A900-A32-03-76P1 11
Issue: 4 Issue date: March 2013