Académique Documents
Professionnel Documents
Culture Documents
Pg.
INTRODUCCIN
1. OBJETIVOS...................................................................................................................................5
1.1. Objetivo general.....................................................................................................................5
1.2. Objetivos especficos ............................................................................................................5
2. IMPLEMENTOS DE SEGURIDAD.............................................................................................6
3. MATERIALES Y/O EQUIPOS ....................................................................................................6
4. MARCO TEORICO .......................................................................................................................7
5. PROCEDIMIENTO EXPERIMENTAL .................................................................................... 10
6. DATOS OBTENIDOS EN LAS PRUEBAS DE LABORATORIO Y CLCULOS ............. 12
6.1. DATOS. ................................................................................................................................ 12
6.2. CLCULOS ......................................................................................................................... 13
7. CUESTIONARIO Y PREGUNTAS .......................................................................................... 18
7.1. Cuestionario ........................................................................................................................ 18
7.2. Preguntas............................................................................................................................. 29
8. CONLUSIONES ......................................................................................................................... 29
BIBLIOGRAFA
3
INTRODUCCIN
Los medidores de flujo son equipos diseados para originar una cada de presin
que puede medirse y relacionarse con la velocidad de flujo, estos medidores
producen un cambio de la energa cintica del fluido que se est estudiando.
4
1. OBJETIVOS
1.2.2. Hallar el valor del caudal terico y del caudal real o experimental, y
hacer una comparacin entre ellos.
5
2. IMPLEMENTOS DE SEGURIDAD
Bata.
Ventur
Pesas.
Cronometro.
6
4. MARCO TEORICO
El Tubo de Venturi fue creado por el fsico e inventor italiano Giovanni Battista
Venturi (1746 1822). Fue profesor en Mdena y Pava. En Paris y Berna, ciudades
donde vivi mucho tiempo, estudi cuestiones tericas relacionadas con el calor,
ptica e hidrulica. En este ltimo campo fue que descubri el tubo que lleva su
nombre. Segn l este era un dispositivo para medir el gasto de un fluido, es decir,
la cantidad de flujo por unidad de tiempo, a partir de una diferencia de presin entre
el lugar por donde entra la corriente y el punto calibrable de mnima seccin del
tubo, en donde su parte ancha final acta como difusor.
El Tubo Venturi es un dispositivo que origina una prdida de presin al pasar por l
un fluido. En esencia, consta de una tubera corta recta, o garganta, entre dos
tramos cnicos. La presin vara en la proximidad de la seccin estrecha; as, al
colocar un manmetro o instrumento registrador en la garganta se mide la cada de
presin y hace posible calcular el caudal instantneo
7
acero inoxidable, cemento, y revestimientos de elastmeros para paliar los efectos
de la corrosin.
Fuente. Referencia 1.
El tubo Venturi 1se recomienda en casos donde el flujo es grande y que se requiera
una baja cada de presin, o bien, el fluido sea altamente viscoso, se utiliza donde
se requiera el mximo de exactitud, en la medicin de fluidos altamente viscosos, y
cuando se necesite una mnima cada de presin permanente, el tubo Venturi es
difcil de construir y tiene un costo ms alto que otros elementos primarios, su diseo
consiste en una seccin recta de entrada del mismo dimetro que la tubera, ah se
conecta la toma de alta presin, despus contiene una seccin cnica convergente
que va disminuyendo poco a poco y transversalmente la corriente del fluido, se
aumenta la velocidad al disminuir la presin, el diseo adems consiste de una
garganta cilndrica, se coloca ah la toma de baja presin, en esta rea el flujo no
aumenta ni disminuye, el tubo Venturi termina con un cono divergente de
recuperacin, aqu la velocidad disminuye y se recupera la presin, recupera hasta
un 98% de presin para una relacin beta del 0.75.
1
http://www.ecured.cu/index.php/Efecto_Venturi
2
http://www.monografias.com/trabajos31/medidores-flujo/medidores-flujo.shtml
8
humos con conductos no cilndricos, en tuberas de cemento grandes, para
conduccin de agua, etc. Segn la naturaleza de los fluidos de medida, se requieren
modificaciones en la construccin del tubo Venturi como son: eliminacin de los
anillos de ecualizacin, inclusin de registros de limpieza, instalacin de purgas, etc.
Asumiendo que no hay prdidas de energa a lo largo del tubo, y que la velocidad
y las alturas piezomtricas son constantes a travs de cada una de las secciones
consideradas, entonces de la ecuacin de energa tenemos que:
2 2 2
V1 V V
h1 2 h2 n hn
2g 2g 2g (1)
En donde: V1, V2 y Vn son las velocidades del flujo a travs de las secciones 1, 2 y
n. La ecuacin de continuidad para esta situacin es:
V1. A1 V2 . A2 Vn . An Q
(2)
2
2
V2 A2 V
2
h1 2 h2
2g A1 2g
2 g ( h1 h2 )
V2 2
A2
1
A
1
1 : ()2 :
Reemplazando (2):
2 g ( h1 h2 )
Q A2 * 2
A2
1
A
Q V2 .A2 1 (3)
9
Se presentan prdidas de energa entre la seccin 1 y 2 y la velocidad no es
absolutamente constante entre cada una de esas secciones. Como resultado, los
valores de Q medidos usualmente son menores que los calculados de la ecuacin
(3) por lo que se introduce el concepto de un coeficiente que relaciona el caudal
real con el terico. Este coeficiente es determinado experimentalmente y vara con
el tipo de venturmetro utilizado as como tambin con la descarga, pero usualmente
est entre un rango de 0.92 a 0.99
2 g ( h1 h2 )
Q C. A2 * 2
A
1 2
A1 (4)
hn h1 V1 Vn
2 2
2
2
V2 V2
2g
2 2
hn h1 A A
2
2 2
V2 A1 An
2g (5)
5. PROCEDIMIENTO EXPERIMENTAL
10
En ste laboratorio, lo primero que se hizo fue una charla por parte del Ingeniero
acerca de lo que se iba a realizar en este laboratorio y del funcionamiento del
Venturmetro, enseguida se abri la vlvula de purga y se empezaron a registrar las
lecturas manomtricas, la masa y el tiempo, repitiendo este procedimiento para 10
caudales diferentes.
11
6. DATOS OBTENIDOS EN LAS PRUEBAS DE LABORATORIO Y CLCULOS
6.1. DATOS
Tabla 1. Alturas Piezomtricas (mm)
1 2 3 4 5 6 7 8
Masa 1,5 2 2,5 3 3,5 4 4,5 5
(Kg)
Tiempo 49,62 53,6 52,86 48,1 35,7 34,64 36,13 31,18
(s)
Caudal
9,068E-05 0,00011194 0,000141884 0,00018711 0,000294118 0,00034642 0,00037365 0,00048108
3
Para hallar el caudal ( ), utilizamos la siguiente formula:
(3)() 3
= =
()()
En donde es la densidad del agua (1000 3 )
12
Entonces:
(3)(1.5) 5
3
(1) = = 9,06 10
(49,62) (1000 )
3
(3)(5,0) 4
3
(8) = = 4,81 10
(31,18) (1000 )
3
6.2. CLCULOS
Para hallar
(3)() 3
= =
()()
En donde es la densidad del agua (1000 3 )
Entonces:
(3)(1.5) 3
(1) = = 9,06 105
(49,62) (1000 )
3
13
(3)(5,0) 3
(8) = = 4,81 104
(31,18) (1000 )
3
3
9,06105
(1) =
=0,17082
0,0005312
3
0,0004810
(8) =
=1,28424
0,00037
3
Para hallar ( ), utilizamos la siguiente formula:
hA hD /
QTe o ( A D ) A ( 2 )( g )
1 ( AD / AA ) 2
g = 9,8 m/s
2 0,000201 2
() = (0,0005311) 0,143412346
()(1) = 0,
220198 / 1000 m3
QTeo ( A D )(1 ) 0,000531
( 2 )(9 , 8 ) 0 , 000107869
1 0,14341234 s
14
238 36 / 1000 m3
QTeo ( A D )(8 ) 0,000531
( 2 )(9 ,8 ) 0 , 000392826
1 0,14341234 s
=
En donde:
= (1000 )
3
= 0,00000114
(0,1708217)(198)
(1) = = 29669,0313
(1000)(0,00000114)
(1,2842435)(36)
(8) = = 40555,0578
(1000)(0,00000114)
9,0689 105
(1) = = 0,0840762
0,000107869
0,000481078
(8) = = 1,22456584
0,000392826
15
Tabla 4. Distribucin ideal de presiones.
16
Para calcular la distribucin ideal de presiones utilizamos la siguiente formula:
2
(2)()
3
9,06892E 05
(1) = = 0,170821696
0,000531 2
17
Tabla 6. Prdida de Energa (m)
(1) =
2
(2)()
Entonces:
220 220
(1) = 1000 =0
0,1772
(2)(9,8)
212 204
(8) = 1000 = 0,620618295
0,4932
(2)(9,8)
7. CUESTIONARIO Y PREGUNTAS
7.1. Cuestionario
18
7.1.1. Anlisis de cada uno de los trminos de la ecuacin de Bernoulli
explicando el tipo de energa que representa cada uno de ellos
Donde:
Por tanto, para aplicar la ecuacin se deben realizar los siguientes supuestos:
19
Viscosidad (friccin interna) = 0 Es decir, se considera que la lnea de
corriente sobre la cual se aplica se encuentra en una zona 'no viscosa' del
fluido.
Caudal constante
Flujo incompresible, donde es constante.
La ecuacin se aplica a lo largo de una lnea de corriente o en un flujo
laminar.
a) Tubo de Pitot 3
b) Tubo de Prandtl4
El tubo de Prandtl es una variante del tubo de Pitot en donde las tomas de presin
esttica se realizan directamente en el instrumento en vez de hacer otra toma de
3
http://docsetools.com/articulos-utiles/article_123487.html
4
http://webdelprofesor.ula.ve/ingenieria/djean/index_archivos/INST_Flujo/medidoresflujovolumetrico/tub
odeprandtl.html
20
presin en la tubera. De hecho el tubo de Prandtl es el instrumento que
comnmente se usa para medir velocidad de un fluido, siendo el tubo de Pitot usado
principalmente para medir la presin de estancamiento. Pero en la prctica se le
suele llamar a este instrumento tubo de Pitot, siendo el nombre de tubo de Prandtl
menos conocido.
c) Anemmetros (tipos)5
5
http://es.omega.com/prodinfo/anemometros.html
21
trmico y el anemmetro de copas (que se usa tpicamente en estaciones
meteorolgicas) se usan principalmente para medir la velocidad media, mientras los
anemmetros de hilo caliente normalmente se usan cuando se estn midiendo
las caractersticas de turbulencia, como las mediciones transversales en una
seccin transversal (el trmino "anemmetro trmico" se usa con frecuencia para
indicar cualquier anemmetro que usa una relacin entre la transferencia de calor y
la velocidad para determinar la velocidad).
d) Molinete (o correntmetro)6
Aplicaciones
Ventajas
6
http://www.maser.com.co/producto.php?idProducto=735&color=33&categorias_id=135
22
La superficie de contacto, casi sin friccin, incrementa la precisin del
instrumento.
Fcil de usar y con un mantenimiento muy sencillo.
Se puede hacer descender con un tubo o un hilo.
Si se utiliza PDA, permite analizar los datos de la medicin directamente en
el campo.
f) Sifn8
g) Eyector9
7
http://es.omega.com/prodinfo/anemometros.html
8
http://recursostic.educacion.es/secundaria/edad/4esotecnologia/quincena9/4q9_sabermas_1ab1.htm
9
http://webdelprofesor.ula.ve/ingenieria/leonardo/MatApoyo/Dise%F1oI/EYECTORES.pdf
23
Son equipos capaces de incrementar la presin de un lquido o un gas mediante el
arrastre del fluido en cuestin por un fluido motriz a alta velocidad a travs de una
boquilla. Los eyectores no tienen piezas mviles, pero son menos eficientes que las
bombas o compresores. Se usan cuando se dispone de grandes cantidades de
vapor o gas como fluidos motrices a bajo costo. Su uso ms amplio es para producir
vaco.
Series2
15
Series3
10
Series4
5
Series5
0
Series6
0 50 100 150 200
-5
Series7
-10 Series8
-15 Series9
-20 Series10
Separacin piezometros (mm)
24
7.1.5. Calcular el Caudal Terico (QT).
()
9,3897E-05 0,00021
0,00011752 0,00023
0,00011962 0,00021
0,00015443 0,00026
0,00017413 0,00028
0,00020398 0,00028
0,00022508 0,00031
0,00024631 0,00032
0,00026961 0,00034
0,00029268 0,00036
Q experimental Vs Q teorico
0,0006
0,0004
0,0003
0,0002
0,0001
0
0 0,00005 0,0001 0,00015 0,0002 0,00025 0,0003 0,00035 0,0004 0,00045
-0,0001
Q teorico (m^3/s)
25
C = -0,0002
7.1.7. Calcular el coeficiente C para con cada uno de los caudales a partir de
Q y (h1- h2)1/2.
Q (m^3/s) (ha-hd)^0,5
(m)
9,0689E-05 0,14832397
0,00011194 0,20976177
0,00014188 0,244948974
0,00018711 0,293257566
0,00029412 0,33763886
0,00034642 0,389871774
0,00037365 0,421900462
0,00048108 0,449444101
0,0005
y = 0,618x
0,0004 R = 0,9718
0,0003
0,0002
0,0001
0
0 0,1 0,2 0,3 0,4 0,5
26
C = -0.002
Coeficiente Vs Q exp
1,5
y = 1527,4x + 0,1085
Coeficiente C
R = 0,9945
1
Series1
0,5
Lineal (Series1)
0
0 0,0001 0,0002 0,0003 0,0004 0,0005 0,0006
Q exp (m^3/s)
C = 0,3167
7.1.10. Para uno de los caudales con que se presente presin negativa en la
garganta dibujar la lnea piezomtrica y la lnea de energa.
piezometrica h energia
N X V(m/s) h (m)
(mm) (mm)
A 0 256 0,27564789 0,256 0,25987662
B 20 254 0,34620644 0,254 0,26011525
C 32 228 0,55036278 0,228 0,24345404
D 46 190 0,72770494 0,19 0,217018086
E 61 196 0,66098222 0,196 0,218290688
F 76 218 0,54625406 0,218 0,233224158
G 91 230 0,45846323 0,23 0,240723905
H 106 238 0,39066061 0,238 0,245786516
J 121 242 0,3365719 0,242 0,247779625
K 136 246 0,29315197 0,246 0,250384596
L 156 248 0,27564789 0,248 0,25187662
27
h piezometrica Vs Separacin piezometros
300
250
h piezometrica (mm)
200
150
100 Series1
50
0
0 50 100 150 200
Separacin piezometros (mm)
0,245
0,24
0,235
0,23 Series1
0,225
0,22
0,215
0,21
0 50 100 150 200
Separacin piezometros (mm)
7.1.11. Obtener las prdidas de energa del fluido al pasar por todo el
venturmetro.
28
R/ Estos datos se encuentran desarrollados en la parte de los clculos.
7.2. Pregunta
R/ En general me parece que el aparato est muy bien diseado, pero si existiera
un mecanismo digital que arrojara las lecturas de las alturas piezomtricas sera
perfecto, puesto que muchas veces los errores que se encuentran a la hora de
realizar los clculos, se deben principalmente a que estas alturas quedaron mal
tomadas debido a la falta de precisin que se tiene en la vista a la hora de tomarlas
correctamente.
8. CONLUSIONES
29
Aunque se presentaron algunos errores, la prctica de laboratorio se
desarroll de forma adecuada, puesto que los valores experimentales
concuerdan con los valores tericos y las grficas corresponden a la teora.
BIBLIOGRAFA