Académique Documents
Professionnel Documents
Culture Documents
Limit hand
2
certificate provided
L2
Test method
Sandpaper
70
60
Depth of wear (m)
50
Carbide
40
30
20
10
Ruby
0
0 1 3 5
Rotation length (km)
3
Enhanced Durability, Improved readability
Sensitivity and Readability Using universal fonts, changing dial face
color and reviewing the relationship
between pointer and scale marks have
drastically improved readability.
Conventional New
Parts
Flange
Easy to remove Hard to remove Frame
Conventional New
Contact point Cover
(on stylus)
4
Choice of dial position
Four models are available, each with a different orientation of the dial to allow
the best visibility in any situation.
H orizontal (standard model) - dial is on top of the frame.
V ertical: dial is on the end of the frame.
H orizontal (20 tilted face): dial is on top of the frame but tilted 20.
P arallel: d ial is on the side of the frame.
Maintain trackability
T he ability of the indicator to track small changes in
displacement deteriorates with prolonged use due
to minute changes in clearance between the gears.
Redesigned mounting for the gears enables the ability
Indicator trackability depends on maintaining gear-train stability
to maintain good trackability.
5
Horizontal (Standard model)
Metric Wide variations of models conform to the required accuracy, range and surface of workpieces.
.9
Standard Long stylus
33
Contact point No. 137557 Double scale spacing Contact point No. 131324 Carbide contact
point (Anti-magnet)
Carbide contact
point (Anti-magnet) Double scale spacing
(non-magnet) (non-magnet)
Contact point No. 21CZA210 Standard Contact point No. 21CZA201 Standard
Double scale spacing
17
18
513-404-10T/513-404-10C 513-415-10T
41
17
6
Graduation: 0.01mm Graduation: 0.002mm
Range: 1.0mm Range: 0.2mm
.2
15
(non-magnet) (non-magnet)
.0
41
Contact point No. 21CZA211 Long stylus Contact point No. 21CZB068 Standard
15
18
counter counter
Contact point No. 137557 Double scale spacing Contact point No. 103011 Carbide contact
Carbide contact point (Anti-magnet)
point (Anti-magnet)
513-405-10T
15
Standard Compact
Contact point No. 103011 Carbide contact Contact point No. 103011 Carbide contact
point (Anti-magnet) point (Anti-magnet)
.2
11
7
Horizontal (Standard model)
Inch
in
5
n
0.6
5i
Standard Compact
0.6
1i
5i
0.6
Standard Standard
0.6
512-479-10E 513-463-10E
1i
512-479-10 513-463-10
0.6
8
Metric/Inch Inch/Metric
in
Carbide contact Carbide contact
5
15
0.6
point (Anti-magnet) point (Anti-magnet)
Contact point No. 103011 Contact point No. 133195
DIMENSIONS
L1 38.7
L1 38.7
L2 L2
8 -0.03
8 -0.03
0
0
8.7
8.7
40 19.5 29.2 25
27
27
18
18
8.85
8.9
9
Horizontal (Standard model)
SPECIFICATIONS
Metric
Order No. Indication accuracy
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Mass
reading Measuring 10 scale Hysteresis Repeatability
Long stylus
Basic set Plus set Full set force
Compact
Standard
range divisions
Inch
Order No. Indication accuracy
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Mass
Long stylus
Basic set Plus set Full set reading One rev. Hysteresis Repeatability force
Compact
Standard
C
513-402-10E 513-402-10T
0.3N or less
513-472-10E
45g
513-412-10E 513-412-10T 0.0005 in 0.03 in 0-15-0 0.0005 in 0.0002 in 0.0002 in
0.2N or less
513-479-10E
513-462-10E 41g
513-403-10E 513-403-10T
45g 0.3N or less
513-473-10E 0.0001 in 0.008 in 0-4-0 0.0001 in 0.0001 in 0.00004 in
513-463-10E 41g
Metric/Inch
Order No. Indication accuracy
With revolution counter
(Anti-magnet)
Graduation Range
Dial
Mass
Measuring (non-magnet)
reading Measuring 10 scale Hysteresis Repeatability
Long stylus
range divisions
C
Inch/Metric
Order No. Indication accuracy
With revolution counter
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Measuring Mass
Long stylus
Basic set Plus set Full set reading Hysteresis Repeatability force
Compact
Standard
range
513-406-10E 513-406-10T 0.0005 in 0.03 in 0-15-0 0.0005 in 0.0002 in 0.0002 in 45g 0.3N or less
/0.01mm /0.7mm /0-35-0
10
Parallel (The scale can be read from the front, with the contact
point pivoting in a plane parallel to that of the dial face.)
Metric
.2
.4
Carbide contact
15
17
Inch
513-486-10 513-486-10E 5i
n 513-482-10 513-482-10A/513-482-10T
.7
Carbide contact
18
Contact point No. 137557 Carbide contact Contact point No. 133195 point (Anti-magnet)
point (Anti-magnet)
SPECIFICATIONS
Metric
(Anti-magnet)
(non-magnet)
Long stylus
Dial Measuring
Compact
Standard
Graduation Range Mass
Basic set Plus set Full set reading Measuring 10 scale Hysteresis Repeatability force
range divisions
Inch
(Anti-magnet)
(non-magnet)
Long stylus
Dial Measuring
Compact
Standard
513-482-10A 513-482-10T 0.0005 in 0.03 in 0-15-0 0.0005 in 0.0002 in 0.0002 in 53g 0.3N or less
* Stem with 6 dovetail groove is not included in the mass.
* Be sure to perform calibration with reference gage, etc. after changing the contact point. The inside parts may be damaged when the contact point is changed due to the breakage.
In the case the of the significant deterioration during the operation, repair is required.
DIMENSIONS
17.5
21.2 6.9 Unit: mm
* No dovetail in the back. 8 0
-0.03 3.9
8.8
17
23.5
22.3
40
Order No. L1 L2
72.1
11
Vertical (Best suited for centering holes under the spindle of a machine tool.)
Metric Inch
0.65 in
point (Anti-magnet)
17.4
Graduation: 0.002mm
Graduation: 0.0001 in
Range: 0.2mm
Range: 0.008 in
513-455-10 513-455-10E/513-455-10A/ 513-453-10 513-453-10E/513-453-10T
513-455-10T
Carbide contact
Carbide contact point (Anti-magnet)
point (Anti-magnet)
15.2
0.61 in
Graduation: 0.01mm
Range: 0.5mm
513-456-10 513-456-10E
Double scale spacing
Carbide contact
18.7
point (Anti-magnet)
Contact point No. 137557
12
SPECIFICATIONS
Metric
Order No. Indication accuracy
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Mass
reading Measuring 10 scale Hysteresis Repeatability
Long stylus
Basic set Plus set Full set force
Compact
Standard
range divisions
Inch
Order No. Indication accuracy
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Measuring Mass
Long stylus
Basic set Plus set Full set reading Hysteresis Repeatability force
Compact
Standard
range
C
513-452-10E 513-452-10T 0.0005 in 0.03 in 0-15-0 0.0005 in 0.0002 in 0.0002 in
46g 0.3N or less
513-453-10E 513-453-10T 0.0001 in 0.008 in 0-4-0 0.0001 in 0.0001 in 0.00004 in
* Stem with 6 dovetail groove is not included in the mass.
* Be sure to perform calibration with reference gage, etc. after changing the contact point. The inside parts may be damaged when the contact point is changed due to the breakage.
In the case the of the significant deterioration during the operation, repair is required.
DIMENSIONS
Unit: mm
40 17.5
8 -0.03
0
55.4
59.4
Order No. L1 L2
23.5 513-454-10E 20.9 17.4
513-455-10E 18.7 15.2
513-456-10E 22.2 18.7
L1
L2
7 20.3
13
Horizontal ( 20 Tilted Face) (Dial face inclined 20, compared with the vertical type.)
Metric
.2
With revolution With revolution
17
15
counter counter
Contact point No. 103006 Carbide contact Contact point No. 103011 Carbide contact
point (Anti-magnet) point (Anti-magnet)
Inch
5i
5i
counter counter
0.6
0.6
n
0i
0i
1.2
Contact point No. 136290 Carbide contact Contact point No. 136290 Carbide contact
point (Anti-magnet) point (Anti-magnet)
n
1i
1i
counter counter
0.6
0.6
14
SPECIFICATIONS
Metric
Order No. Indication accuracy
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Mass
reading Measuring 10 scale Hysteresis Repeatability
Long stylus
Basic set Plus set Full set force
Compact
Standard
range divisions
Inch
Order No. Indication accuracy
(Anti-magnet)
(non-magnet)
Dial Measuring
Graduation Range Measuring Mass
Long stylus
Basic set Plus set Full set reading Hysteresis Repeatability force
Compact
Standard
range
C
513-442-10A 513-442-10T
0.3N or less
513-442-16A 513-442-16T
0.0005 in 0.06 in 0-15-0 0.0005 in 0.0002 in 0.0002 in
513-446-10A 513-446-10T
48g 0.2N or less
513-446-16A 513-446-16T
513-443-10A 513-443-10T
0.0001 in 0.016 in 0-4-0 0.0002 in 0.0001 in 0.00004 in 0.3N or less
513-443-16A 513-443-16T
* Stem with 6 dovetail groove is not included in the mass.
* Be sure to perform calibration with reference gage, etc. after changing the contact point. The inside parts may be damaged when the contact point is changed due to the breakage.
In the case the of the significant deterioration during the operation, repair is required.
DIMENSIONS
Unit: mm
L1 55.7
L2
8.7
Order No. L1 L2
513-445-10E 18.7 15.2
40 513-444-10E 20.9 17.4
8 -0.03
0
20
16
17
59.7 23.5
Refer to MEASURING INSTRUMENTS CATALOG No. US-1004 for the accessories such as styli, stems with dovetail, holding bars, etc.
15
2017 Mitutoyo America Corporation
Coordinate Measuring Machines Vision Measuring Systems Form Measurement Optical Measuring
Whatever your challenges are,
Mitutoyo supports you from start to finish.