FASTER UltraSafe
APPLICATIONS

Faster UltraSafe
Class II Microbiological Safety Cabinets
Faster UltraSafe Class II
EN ISO 9001:2000 quality assured firm
Microbiological Safety Certificate n°112

Cabinets have been adopted


worldwide in use for product,
personnel and environmental
protection while handling
harmful agents pathogenic to
human beings and/or animals
as defined in the appropriate
international standards, in a
wide range of disciplines in
applications such as:
Microbiology, Virology,
Haematology, Cell culture,
Genetics, Handling of
hazardous agents to human
beings or animals.

FASTER-ULTRASAFE/2007/01
Protection, safety, reliability. And more.

Distributed by:

Faster S.r.l.
Via Merendi, 22 20010 Cornaredo (MI) Italy
Tel +39 02 93 991 92 Fax +39 02 93 991 608
www.faster-air.com info@faster.dgroup.it :
a D GROUP company
UltraSafe 630x297 01-08-2007 17:28 Pagina 2

FASTER UltraSafe FASTER UltraSafe FASTER UltraSafe FASTER UltraSafe


BEYOND MINIMUM SAFETY ULTRA FEATURES SUPERIOR FEATURES TECHNICAL

dimensions
Dimensions
SPECIFICATIONS [wxhxd]

Exhaust
REQUIREMENTS

Weight
Supply
Power
Usefull Overall
[mm] [mm] [kW] [V/Hz] [Kg] [mm]
Faster UltraSafe 209 S 899 1045 0,7 170 427x427

1500*x860**
700x600

230/50
Faster UltraSafe 212 S 1194 1350 1 195 427x580
Faster UltraSafe 215 S 1499 1655 1,2 225 427x732
Faster UltraSafe 218 S 1804 1960 1,4 260 427x885
Faster UltraSafe Microbiological Safety Cabinets belong to the Ergonomic Design. The angled Rear wall in stainless steel The user-friendly practical keyboard The cabinet is fitted, as standard,
Faster UltraSafe 209 D 899 1045 0,85 175 427x427

1500*x860**
with one manual tap,

700x600
sloping front safety-glass sash provides AISI 304L, designed to conform to and the rear-lit LCD will continuously

230/50
latest generation of laminar airflow systems manufactured by Faster, one gas tap with solenoid valve, Faster UltraSafe 212 D 1194 1350 1,1 200 427x580
optimum visibility of all objects placed requirements and pass the “cleanability display all required data keeping the one electrical socket (for models 209 and 212) Faster UltraSafe 215 D 1499 1655 1,3 230 427x732
in which the choice of materials of construction of the highest qua- or two electrical sockets Faster UltraSafe 218 D 1804 1960 1,5 265 427x885
in the interior workspace. The sash is test” according to EN12469:2000. user constantly informed of the cabinet * 2300 with stand support ** 795 without back panel *** 200 on request
(for models 215 and 218)
lity guarantees conformity to the strictest safety standards. electrically operated. Pressing the conditions in operation - and in Working height Front aperture Maximum Aperture Noise Lighting Temperature Rise
appropriate touch-sensitive keys will AISI 316 work surface consisting of particular: [mm] [mm] [mm] [dB(A)] [Lux] [°C]
Faster UltraSafe vertical laminar flow cabinets are Class II completely open or completely close 900 250*** 420 < 57 > 1000 <3
sections which are easily removable for
■ display of laminar airflow velocity
Microbiological Safety Cabinets - designed and built to performan- down the sash. carrying out routine cleaning and/or
The standard sash-height opening
and frontal air barrier velocity ACCESSORIES UV Lamp with full programable timer
ce requirements of the EN-12469:2000 European Standard, with autoclaving sterilization procedures; Customized work surfaces
during work is set to 250 mm. ■ display of inside and outside Epoxy powder painted modular stand
70% of the air re-circulated via the main Class H14 HEPA filter closed or perforated on request. Stainless Steel modular stand
Alternative sash-height settings by the temperature
Electrical adjustable stand (700-1000 mm height)
within the cabinet, whilst the remaining 30% is discharged through factory are possible upon request. Additional electrical power socket
Re-circulating and extractor fans: ■ display of residual lifetime of HEPA
Additional service connection for gas/vacuum (manual tap)
an exhaust Class H14 HEPA filter. The whole front of the safety cabinet – FASTER UltraSafe Microbiological filters, UV Lamp and activated Additional socket for data (RS232, RS485 or RJ45)
which includes the sash mechanism – Safety Cabinets ‘S’-Series are supplied carbon filter (if fitted) Additional exhaust Carbon filter for UltraSafe (only D model)
Safety Cabinets with automatic regulation and microproces- can also be opened upwards as it is
Additional exhaust HEPA filter for UltraSafe (only D model)
with single centrifugal fan, whilst ■ display of total number of hours Anti-blowback valve
sor based monitoring systems. These cabinets are suitable for hinged on the top – in order to allow Exhaust hard duct connection
models of the ‘D’ Series with double of operation
easy access for complete and effective Exhaust thimble connection
handling micro-organisms and pathogens as defined by the centrifugal fan to provide complete 3-Drawers unit on pivotting wheels
cleaning and decontamination. ■ display of saturation level of HEPA
Volt free contact
appropriate European and other International Standards, current operator, product and environmental
filters. Arm rest
Inflatable gasketing is also available as
health and safety guidelines and legislation aimed at safeguarding protection. Inflatable Gasket for front sealing
an option to provide effective sealing of Audio-visual alarms provided for: Vacuum pump for inflatable gasket
Moreover the ‘D’ models fitted with
health and safety of operators at work. the internal workspace of the chamber ■ Out of range or incorrect laminar Sealing kit for exhaust opening
double motor-fan are designed and are Formalin Vaporizer with ammonia neutralization
for purposes of fumigation/sterilization. airflow velocity and frontal air
also suitable to discharge the filtered
air outside the laboratory through a barrier velocity
Silent Operation. The textile plenum, OPERATIONAL
the structures of the electric motors of
the fans fitted on their antivibration
ducting system if required. ■ Uncorrect position of front
sash-window
PRINCIPLES External air
➡ Sterile air
➡ Recirculated air

The ambient air is drawn in from the
mounts and the software itself Microprocessor based monitoring ■ saturation of HEPA filters
slots at the stainless-steel base of the
designed to provide optimum system: full status report provided via
■ end of life-cycle of UV lamp and front opening and it then passes under
airhandling characteristics guarantee digital display by the new generation the work surface, from where it is
saturation of activated carbon filter
quiet operation of this silent safety microprocessors – which automatically drawn up and blown into the plenum of
(if fitted)
cabinet, with sound-pressure levels control all functions and all safety alarm the re-circulating and exhaust fan(s).
■ blockage in the exhaust duct
recorded way below the parameters systems ensuring that performance The “bio-dynamic sealing system” of
specified in the current EN:12469 characteristics are maintained to ■ fan-motor malfunction the negative pressure plenum ensures
European Standard for Microbiological EN12469:2000 requirements. ■ power failure that all contaminated particles are kept
High power lithium battery keeps safety inside the system and are automatically
Safety Cabinets.
drawn to the plenum or pressure
data saved to microprocessor system. UV sterilizing lamp (optional) complete chamber to be captured by the main
High Level Lighting. The safety glass
with two switch-off countdown timers, re-circulating and exhaust HEPA filters.
side-windows with the ideal positoning
one variable on a 0¸3 hours scale The fan system assures that no part of
and sizing of the light-system provide
(1 minute steps), the other set to 3 the cabinet comes ever under positive
the highest level of luminosity to the
fixed hours. contaminated pressure to the
work area.
laboratory, thus protecting and
preserving the environment and
Easy handling and maintenance
operating personnel from exposure to
The safety cabinet can pass through agents of bio-contamination.
800 mm wide door openings. In fact,
70% of the filtered air is re-circulated
the overall depth of the cabinet can be
(after passing through a H14 HEPA) in a
reduced to approx. 790 mm by
ISO 5 laminar flow pattern downwards
removal of the rear panel. into the work chamber and the remain-
Faster UltraSafe cabinet features an ergonomically angled sloping-front, fitted with electrically All service operations are available from
operated vertically sliding safety-glass sash window, the framework of which is also ing 30% is exhausted to atmosphere
hinged and can be opened up for easy access during cleaning and maintenance. the front of the cabinet through another H14 HEPA filter. FASTER UltraSafe