DurasheetTM -
tough and
durable
BGC Durasheet is
designed for the cladding
of gable ends, eaves, soffits,
car ports and verandah
linings of timber and steel
framed buildings.
4.5mm thickness is generally used in timber
framed residential buildings for soffit / eaves linings
and the cladding of features such as gable ends.
6.0mm thickness is recommended for light
commercial applications, cyclonic wind zones
and steel framed constructions.
Durasheet
Available in two thicknesses to suit both
residential and light commercial applications
General purpose sheet
6.0mm suitable for cyclonic wind zones
Classified as Type A Category 2 for exterior use
Can be used on timber and steel framed buildings
Product Description
Fire Resistance
BGC Durasheet is a general-purpose fibre cement sheet
for exterior applications. It is recommended for the cladding Durasheet has been tested by the CSIRO Building,
of gable ends, eaves, carport and verandah linings of timber Construction and Engineering Division, in accordance to
or steel framed buildings. Australian Standard AS1530.3. See report numbers
FNE 6966 and FNE 7529.
Durasheet is a smooth flat square edged sheet and is
manufactured in nominal thickness of 4.5 mm and 6.0 mm. This report deemed the following Early Fire
Hazard Properties:
4.5 mm Durasheet is generally used in timber framed
residential buildings for soffit linings and the cladding of Ignition Index 0
features such as gable ends. Spread of Flame Index 0
Heat Evolved Index 0
6.0 mm Durasheet is recommended for commercial
applications, cyclonic wind zones and steel framed Smoke Developed Index 0-1
construction.
BGC Fibre Cement can supply standard joint moulds for BGC Fibre Cement manufactures Durasheet under the
use with Durasheet as well as a new and contemporary rigorous Quality Management System of the International
joint mould. Standard ISO 9001:2008, and is the holder of Licence
Agreement number QEC2955/13.
Durasheet Smartline gives Durasheet a different look and feel
with a more designer appearance. See your local BGC Fibre
Cement office for a sample of this new joint mould. Handling & Storage
THICKNESS LENGTH WIDTH When cutting sheets, use the methods recommended in
(mm) (mm) (mm) this literature to minimise dust generation. These precautions
are not necessary when stacking, unloading or handling fibre
450 600 750 900 1200 cement products. For further information or a Material Safety
Data Sheet contact any BGC Sales Office.
4.5 1800 x x
2100 x
Fasteners
2400 x x x x x
2700 x x
Timber Framing
3000 x x
The BCA states: The thermal performance of metal The sheet edges must be supported either by nailing
and timber framed wall is affected by conductive thermal at 300 mm maximum centres or by a construction feature
bridging by the framing members and convective thermal such as a grooved fascia board or along an external
bridging at gaps between the framing and any added bulk brick wall.
insulation. Metal framed walls are more prone to conductive
The sheets may be joined on framing when PVC joiners
thermal bridging than timber framed walls.
are used.
Because of the high thermal conductance of metal, a
Where sheets are joined off framing, the bearer centres
thermal break is needed when a metal framing member
of the span are not to be greater than 450 mm for 4.5 mm
directly connect the external cladding to the internal lining
Durasheet or 600 mm for 6.0 mm Durasheet.
or the internal environment. The purpose of the thermal
break is to ensure that the thermal performance of the Where a metal roof is installed directly above soffits,
metal framed wall is comparable to that of a similarly severe thermal movement may occur. Where Durasheet
timber framed wall. is used, it is preferred the roof be vented to allow emission
of hot air as well as providing a reduction in roof
A thermal break may be provided by materials such as
space temperature.
timber battens, plastic strips or polystyrene insulation
sheeting. The material used as a thermal break must
For General Application
separate the metal frame from the cladding and achieve
the specified R-value.
For eaves to 600 mm maximum width:
The R-value of the thermal break is not included when Eave bearers must be provided at a maximum
calculating the Total R-value of the wall, if the thermal break of 600 mm centres.
is only applied to the metal frame, because the calculation
is done for locations free of framing members. For eaves 600 mm ~ 1200 mm wide:
Eave bearers must be at a maximum of 450 mm.
When using a thermal break it must consist of a material
with an R-value of not less than 0.2 and is required when
Refer to table below for specific wind categories
using Lightweight Steel framing.
In many instances Vapour Permeable Sarking can be used
as a thermal Break but please check this with the sarking
manufacturer. Figure 1 - Typical Boxed Eaves Lining
For further information on thermal breaks contact your local
BGC Fibre Cement office.
Typically, when lining a carport with Durasheet, The outer sides and ends of perimeter sheets must
sheets are to be installed at right angles to the ceiling be supported by framing and nailed at 300 mm
joists and/or battens using PVC sheetholders to support all maximum centres.
sheet joints.
Durasheet must not be fixed directly to the
The ends of the sheets should be staggered with a bottom chord of roof trusses. Timber battens
maximum gap of 5.0 mm to facilitate the PVC sheetholder. or metal furrings should be installed.
Fasteners
300 mm
max.centres
Stagger
sheet
joints
Timber framing
Timber Framing
Figure 7 - Sheet Joint Light Weight Steel Framing Figure 9 - External Corners PVC Sheet Joiners
Vapour Permeable
No 8 x 20mm
Sarking
self embedding
head screw Typical light weight
Drive flush with steel wall stud
sheet face Timber
Framing
Timber Framing
Sarking
Ground Clearance
Sarking
A minimum of 100 mm must be maintained from the
bottom edge of the sheet to the ground, see Figure 10.
Internal PVC
Corner Moulding
Figure 10 - Ground Clearance
Sarking
6.00 mm Durasheet
Timber
6.0 mm Durasheet
Framing
Dampcourse
50 mm Sheet Overhang
100 mm min.
Fixing as noted
12 Min 50 Min
100 Max
Fixing as noted
12 Min 50 Min
100 Max
Bracing detail for cyclone regions is available from your local BGC office.
Fixing as noted
25 Min 50 Min
50 Max
Fixing as noted
25 Min 50 Min
50 Max
The tabulated data is applicable to Region C Durasheet cladding subject to freeze/thaw conditions
(Tropical Cyclone areas) including Darwin and 6.0 mm must be painted.
Durasheet is approved for inclusion in the Darwin
Deemed to Comply manual. Durasheet should not be used in situations where it will be
in direct contact with snow or ice for prolonged periods.
6.0 mm Durasheet Wall Cladding - M/222/1
14th November 1997
6.0 mm Durasheet Soffit Cladding - M/222/2
14th November 1997 Bushfire Wall & Eaves
Open Verhanda
EAVES LINING DURASHEETTM 4.5MM 29
Open
Carport
Building
Building
Eaves (Soffit)
1200 mm
Plan View, Eaves & Soffits
Linings Framing & Fixing
Requirements
Normal Areas
Areas requiring
Additional Framing
& Fasteners
1200 mm
AS3959:2009 sets out a series of Bushfire threat levels We warrant that our products are free from defects caused
to buildings described as BAL (Bushfire Attack Levels) as by faulty manufacture or materials for a period of 15 years
follows: BAL-12.5, BAL-29, BAL-40 or BAL-FZ (Flamezone). from the date of purchase. If you acquire any defective
products, we will repair or replace them, supply equivalent
replacement products or refund the purchase price within 30
days of receiving a valid claim subject to product inspection
Painting and confirmation of the existence of a defect by BGC.
We will bear the cost of any such repair, replacement or
refund.
To enhance both the appearance and performance of
Durasheet, BGC recommend that at least two coats of This warranty is given by:
a water-based paint be applied. The paint manufacturers
recommendation on application and maintenance should BGC Fibre Cement Pty Ltd
be followed. 121 Bannister Rd Canningvale WA 6155
Phone 08 9334 4900 Fax 08 9334 4749
Telephone
02 9632 2100 Duragrid Residential and
TM
A base sheet used for textured
Duragrid Light Commercial
TM
coatings on exterior wall
New Zealand A lightweight facade giving applications.
Telephone a modern and durable finish. Duralattice TM
Available in Smooth,
Woodgrain and Rusticated
finishes, is ideal for exterior
cladding of upper storey
conversions or ground
level extensions.
Safe working practices - Please wear a P1 or P2 mask and safety goggles (approved to AS/NZW1337 standards) whilst cutting
or installing DurasheetTM. DurasheetTM can be safely handled during unloading or stacking without the use of these precautions.
Cleaning up - Always wet down your work area when cutting DurasheetTM, to ensure that dust is managed.
Dispose of any vacuumed dust with care and using containment procedures.