General Models SSS5700, SSS6700


Specications Fieldbus Communication
Functions (R5)
GS 33Y05P10-33E

GENERAL PC
With the Fieldbus Communication Function, a eld Engineering Tool
control station (FCS) can be connected via the ACF11 Device Management Tool
or ALF111 Fieldbus Communication Module installed
Ethernet
in an I/O module nest to eldbus-ready sensors and
valves. The GS covers the following communication HIS
functions: HIS
for builder
Fieldbus Feature
Fieldbus Communication Specications Overview
SSS5700 Engineering Tool for Fieldbus Control Bus
SSS6700 Device Management Tool for Fieldbus
FCS FCS

FUNCTION SPECIFICATIONS ESB bus


ACF11
Fieldbus Feature FCS
A eldbus is a digital, bidirectional and multi-drop H1 Fieldbus
connection communication bus that connects eld SB401
ALF111 H1 Fieldbus
devices to control systems, and which replaces
conventional 4-20 mA communication. Its
specications have been standardized by the Fieldbus
Foundation. A eldbus digitally transmits various F01E.ai
data such as tuning data and diagnostic data on eld
devices as well as PVs and MVs. A eldbus ensures Figure Fieldbus Conguration of
interoperability between diverse vendors products. CENTUM VP/CS 3000/CS 1000

PC
Engineering Tool/
Device Management Tool
E net/Ethernet
ICS
EWS
ACG

V net

FCU

RIO Bus

Node Interface Unit

ACF11 Card

H1 Fieldbus

F08E.ai

Figure Fieldbus Connection Conguration of


CENTUM CS

Yokogawa Electric Corporation GS 33Y05P10-33E


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Copyright Jun. 1, 2008
Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 3rd Edition Oct. 1, 2008
<<Contents>> <<Index>> 2
Fieldbus Communication Specications FCS
Overview Sequence
Regulatory Control Block Control Block
Communications with function blocks
The eldbus-ready eld devices are connected through
the ACF11 (ALF111) installed in the FCS I/O module
nest. Field devices data is stored in the PI/O image
area in the ACF11 (ALF111) and sent to the PI/O
Data Setting /
image area in the FCS. The data is then sent to the
Reference
I/O terminals of function blocks like analog/digital I/O
signals. PI/O image

See the GS Foundation Fieldbus Communication ACF11 (ALF111)


Package for ACF11 or Foundation Fieldbus
Communication Package for ALF111 about Fieldbus
communication specications. PI/O image

Other eldbus specications are the same as those of


FOUNDATION Fieldbus. Fieldbus Communication Function

F02E.ai

Figure Process Data Flow of Fieldbus


Communication

All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 33Y05P10-33E Jun. 1, 2008-00
<<Contents>> <<Index>> 3
Model SSS5700 Engineering Tool for PC
Fieldbus Engineering Tool
Specications
The Engineering Tool is used for eldbus
engineering, such as dening a part of ACF11 Upload parameters Refer setting
function and eldbus compliant eld devices. It runs
on a personal computer connected to a control bus Ethernet
or HIS for builder in the CENTUM VP/CS 3000/CS
1000 systems; it runs on a personal computer
connected to the E net/Ethernet of the CENTUM CS HIS HIS for
systems. With the tool, the users can graphically Builder
dene a devices parameters, inter-instrument Control Bus
data connections, the sequence and period of data
connections.
If the tool is connected with CENTUM CS, it can FCU
send and automatically map the setting data made
by the tool to the builders in CENTUM CS. This will
facilitate the connection between Fieldbus devices
and function blocks on an FCU. Download setting
If an ALF111 is used in a CENTUM VP/CS 3000
system, you can use Fieldbus Builder provided
with Standard Builder Function for engineering the ACF11 Download setting
eldbus, therefore the tool is not needed.
Features
The Engineering Tool for Fieldbus consists of the
following features:
F04E.ai

Engineering Tool
Figure Data Flow in Engineering Tool of
CENTUM VP/CS 3000/CS 1000
Project Manager
PC
Builder
Engineering Tool
Network Startup Function

Maintenance Function Upload Parameter


Send
Utility E net/Ethernet Settings
F03E.ai

Figure Engineering Tool for Fieldbus


ICS ACG EWS
Project Manager
Manages all elements and functions of Engineering V net
Tool.
Builder
Creates the setting data of eld devices FCU
function block application function and ACF11s RIO Bus
communication function. It is used to:
Register eldbus devices; NIU
Dene network conguration; Download Settings
Create function blocks of eldbus devices;
Set parameters of function blocks of eldbus devices ACF11 Download
and communication scheduling. Settings
Network Startup Function
Downloads the builder-dened data to eld devices
and ACF11.
Executes Tag Assignment and Address Assignment. F09E.ai

Maintenance Function Figure Data Flow in Engineering Tool of CENTUM CS


Uploads parameters such as eldbus function blocks
from eldbus devices.
Utility
Provides print and security functions.

All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS33Y05P10-33E Jun. 1, 2008-00
<<Contents>> <<Index>> 4
Model SSS6700 Device Management Tool PC
for Fieldbus Device Management Tool
Specications
The Device Management Tool monitors and manages
the eldbus-connected devices. It runs on a personal Acquire the status of
computer connected to a control bus or HIS for Acquire
devices and parameters messages
builder in the CENTUM VP/CS 3000/CS 1000 Ethernet
systems; it runs on a personal computer connected
to the E net/Ethernet of the CENTUM CS systems. HIS
With the tool, the users can monitor, manage eld HIS for (*1)
devices (sensors, positioners and analyzers) on a Builder
eldbus, display, dene and maintain parameters. Control Bus
The tool also has the function to automatically read
messages from eld devices on a eldbus via HIS
(ICS), which allows total management of eldbus FCU
devices.
Features ACF11 Define
The Device Management Tool for Fieldbus consists parameters
of the following features:

Device Management Tool

*1: Exaopc OPC Interface (for HIS). F06E.ai


Field Device Listing
Figure Data Flow of Device Management Tool of
Field Device Status Display CENTUM VP/CS 3000/CS 1000 (For using ACF11)

Message Display PC
Device Management Tool
Parameter Display and Setting

Device Method
Acquire the status of Acquire
Common Features
devices and parameters messages
F05E.ai Ethernet

HIS
Figure Device Management Tool for Fieldbus HIS for (*1)
Builder
Field Device Listing Control Bus
Manages eld devices and lists the dened data for
devices.
FCU
Field Device Status Display
Displays eld device status, READY/NOT_READY.
Message Display ALF111 Define
Displays messages from eld devices and ACF11 parameters
or ALF111 by acquiring alarms and events of eld
devices from HIS (ICS) historical message les.
Parameter Display and Setting
Displays the parameters of function blocks in eld *1: Exaopc OPC Interface (for HIS). F07E.ai
devices and changes them if possible. Tuning
parameters are also displayed and changed. Figure Data Flow of Device Management Tool of
CENTUM VP/CS 3000/CS 1000 (For using ALF111)
Device Method
Runs control procedures congured by the device
vendors. It describes procedures to run specic
features for the device such as calibration and reset.
Common Features
Displays the device management history of eld
devices, prints reports, and provides security
function.

All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 33Y05P10-33E Jun. 1, 2008-00
<<Contents>> <<Index>> 5
PC OPERATING ENVIRONMENT
Device Management Tool
DDE Server
Hardware Requirements
PC: IBM PC/AT-compatible
Acquire device status Main memory: 1 GB or larger
Acquire Hard disk space: 40 GB or bigger
and parameter
E net/Ethernet message (1 GB or bigger free space)
CPU: Pentium III 1 GHz or faster
DDE ICS Interface card: Ethernet card
EWS Remote For CENTUM VP/CS 3000/CS 1000:
ACG Server
Control bus interface card (VF701, VI701)
V net
Software Requirements
Windows Vista Business Edition SP1
FCU Windows XP Professional SP2
Windows XP Professional SP3
RIO Bus
Windows Server 2003 R2 Standard Edition SP2
Windows Server 2003 Standard Edition SP2
NIU
All of the above support only 32 bit OS.

ACF11 Supported Device Files


Parameter
Settings DD le: Version 5
Capabilities le: Version 1.8

Others
F10E.ai
To use the Device Management Tool, the following
Figure Data Flow of Device Management Tool of packages are required:
CENTUM CS
For CENTUM VP/CS 3000/CS 1000:
LHS2411/PHS2411 Exaopc OPC Interface Package
(for HIS)
For CENTUM CS:
SHW5860, SIH5860 or SIU5860 DDE
Communication Builder
SIH2410 or SIU2410 DDE Remote Server Package
SSS2410 DDE Server Package

All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS33Y05P10-33E Oct. 1, 2008-00
<<Contents>> <<Index>> 6
MODELS AND SUFFIX CODES TRADEMARKS
CENTUM and Exaopc are registered trademarks of
Description YOKOGAWA Electric Corporation.
Engineering Tool for Fieldbus Pentium is a registered trademark of Intel
Model SSS5700
[Media model: SSSSM01-C11] Corporation.
-S Basic Software License Ethernet is a registered trademark of XEROX
Multiple Software License Corporation.
Sufx -C
(for 2 or more computers) Windows and Windows Vista are registered
Codes
1 Always 1 trademarks of Microsoft Corporation in the United
1 English version States and /or other countries.
FOUNDATION of FOUNDATION Fieldbus is a registered
trademark of Fieldbus Foundation.
Description Other product and company names appearing in this
Device Management Tool for Fieldbus document are trademarks or registered trademarks of
Model SSS6700
[Media model: SSSSM01-C11] their respective holders.
-S Basic Software License
Multiple Software License
Sufx -C
(for 2 or more computers)
Codes
1 Always 1
1 English version

ORDERING INFORMATION
Specify model and sufx codes.

All Rights Reserved. Copyright 2008, Yokogawa Electric Corporation GS 33Y05P10-33E Jun. 1, 2008-00